FR-N1X1G1-flex (NF C 32-323), YMz1Kf & YMvKf 0.6/1–1.8/3 kV Power Cable

FR-N1X1G1-flex 0.6/1 kV and 1.8/3 kV (French NF C 32-323), YMz1Kf 0.6/1 kV and 1.8/3 kV (Dutch NEN / IEC 60502-1 halogen-free CPR B2ca/Cca), and YMvKf 0.6/1 kV and 1.8/3 kV (Dutch NEN / IEC 60502-1 flame-retardant CPR Cca) are European Class 5 flexible 90 °C XLPE-insulated low-voltage power and control cables. Replacing rigid Class 1/2 U-1000 R2V, FR-N1X1G1-R/U, YMz1K and YMvK cables.

  • Model designationsFR-N1X1G1-flex (0.6/1 & 1.8/3 kV), YMz1Kf (0.6/1 & 1.8/3 kV) & YMvKf (0.6/1 & 1.8/3 kV)
  • Reference standardsNF C 32-323 (French), NEN 1010 / KEMA / IEC 60502-1 / UNE 21123 (Dutch/EU)
  • Rated voltage U0/U0.6/1 kV AC (Um 1.2 kV) & 1.8/3 kV AC (Um 3.6 kV / 2.7/5.4 kV DC)
  • Conductor (-flex / -f)Class 5 flexible annealed electrolytic copper (1.5–630 mm², IEC 60228)
  • Insulation (X1 / Ym)90 °C cross-linked polyethylene (XLPE), +250 °C short-circuit rating
  • Outer sheathLSZH polyolefin (G1 on FR-N1X1G1, z1 on YMz1Kf) or Cca flame-retardant PVC (v on YMvKf)
  • CPR EuroclassesB2ca-s1a,d1,a1 / Cca-s1a,d1,a1 (FR-N1X1G1 & YMz1Kf); Cca-s2,d2,a3 (YMvKf)
  • Min. bending radius5 × OD; operating temperature -40 °C (fixed) to +90 °C

FR-N1X1G1-flex Core Identification & Ratings

  • Type: PVC Control & Data Cable
  • Model designations: FR-N1X1G1-flex (0.6/1 & 1.8/3 kV), YMz1Kf (0.6/1 & 1.8/3 kV) & YMvKf (0.6/1 & 1.8/3 kV
  • Reference standards: NF C 32-323 (French), NEN 1010 / KEMA / IEC 60502-1 / UNE 21123 (Dutch/EU
  • Rated voltage U0/U: 0.6/1 kV AC (Um 1.2 kV) & 1.8/3 kV AC (Um 3.6 kV / 2.7/5.4 kV DC

Electrical, Thermal & Mechanical Bend Limits

  • Conductor (-flex / -f): Class 5 flexible annealed electrolytic copper (1.5–630 mm², IEC 60228
  • Insulation (X1 / Ym): 90 °C cross-linked polyethylene (XLPE), +250 °C short-circuit rating
  • Outer sheath: LSZH polyolefin (G1 on FR-N1X1G1, z1 on YMz1Kf) or Cca flame-retardant PVC (v on YMvKf
  • CPR Euroclasses: B2ca-s1a,d1,a1 / Cca-s1a,d1,a1 (FR-N1X1G1 & YMz1Kf); Cca-s2,d2,a3 (YMvKf
  • Min. bending radius: 5 × OD; operating temperature -40 °C (fixed) to +90 °C

FR-N1X1G1-flex Conductor, Insulation & Sheath Build

FR-N1X1G1-flex, YMz1Kf and YMvKf combine Class 5 flexible copper strands with 90 °C XLPE core insulation and CPR-classified LSZH or flame-retardant PVC sheaths.

  • Conductor (-flex / -f): Class 5 flexible annealed electrolytic copper per IEC 60228 / EN 60228.
  • Insulation (X1 / Ym): 90 °C cross-linked polyethylene (XLPE) type DIX-3 / XLPE per IEC 60502-1.
  • Core Identification: HD 308 S2 color code (2–5 cores); black cores with sequential white numbers + G/Y on ≥6 cores.
  • Outer Sheath (G1 / z1 / v): LSZH polyolefin on FR-N1X1G1-flex & YMz1Kf (B2ca/Cca); special bunched-fire-retardant PVC on YMvKf (Cca-s2,d2,a3).

Primary Electrical & Mechanical Performance

  • French NF C 32-323 FR-N1X1G1-flex: Direct Class 5 flexible equivalent to rigid NF C 32-323 FR-N1X1G1, certified Cca-s1a,d1,a1 for French ERP (public buildings) and IGH (high-rise towers).
  • Dutch NEN 1010 YMz1Kf (B2ca / Cca LSZH): Meets Dutch NEN 1010 and EN 50575 B2ca-s1a,d1,a1 / Cca-s1a,d1,a1 requirements for hospitals, data centers, tunnels, and offices.
  • Dutch YMvKf (CPR Cca-s2,d2,a3): Upgrades standard Eca PVC cables (RV-K) to CPR Cca-s2,d2,a3 bunched fire performance for industrial plants, food processing, and infrastructure.
  • Available in both 0.6/1 kV & 1.8/3 kV: All three designations (FR-N1X1G1-flex, YMz1Kf, and YMvKf) are manufactured in both 0.6/1 kV and 1.8/3 kV (1,500 V DC solar/inverter) ratings.

Industrial Oil, Flame & Environmental Protection

  • 5 × OD bending radius (Class 5 copper): Eliminates the spring-back and terminal torque stress of Class 2 stranded conductors on molded-case circuit breakers and VFD terminals.
  • 90 °C XLPE thermal reserve: +90 °C continuous operating temperature (+250 °C short-circuit) allows smaller conductor cross-sections than 70 °C PVC cables.
  • UV-resistant EN 50618 outdoor sheath: Outer sheaths on FR-N1X1G1-flex, YMz1Kf, and YMvKf pass UV weathering for exposed rooftop solar trays, cable bridges, and buried ducts.
  • Complete European harmonized portfolio: Cross-reference withFG16(O)R16 / FG16(O)M16 Italian Cca cablesandN2XH / (N)HXH FE180 German VDE cables.

IEC / EN / VDE / UL Reference Standards

  • NF C 32-323: French 0.6/1 kV & 1.8/3 kV halogen-free XLPE/LSZH cable FR-N1X1G1-flex
  • NEN 1010 / IEC 60502-1 / UNE 21123: Dutch YMz1Kf LSZH & YMvKf flame-retardant PVC cables
  • EN 50575 & EN 50399: CPR Euroclass B2ca-s1a,d1,a1, Cca-s1a,d1,a1 & Cca-s2,d2,a3
  • IEC 60332-3-24, IEC 61034-2: >80% light transmittance) & EN 60754-1/2 (zero halogen on FR-N1X1G1 / YMz1Kf

Industrial Cable Selection & Routing Guides

Industrial switchboard and cable tray installation using French FR-N1X1G1-flex and Dutch YMz1Kf / YMvKf 0.6/1 kV and 1.8/3 kV Class 5 XLPE cables
FR-N1X1G1-flex (NF C 32-323), YMz1Kf (B2ca/Cca LSZH) and YMvKf (Cca) deliver Class 5 copper flexibility for French and Benelux electrical installations. Photo: Wikimedia Commons contributor, CC BY-SA 3.0, via Wikimedia Commons.

FR-N1X1G1-flex Industrial Installation & Routing Guide

Engineering schedules in France (NF C 15-100 / NF C 32-323) and the Netherlands / Belgium (NEN 1010) use national cable designations that specify fire reaction, insulation polymer, and conductor flexibility. FR-N1X1G1-flex is the French NF C 32-323 Class 5 flexible halogen-free power cable: FR-N denotes French national standard, 1 denotes 0.6/1 kV (also produced in 1.8/3 kV), X1 denotes 90 °C cross-linked polyethylene (XLPE) insulation, G1 denotes a halogen-free thermoplastic polyolefin outer sheath (CPR Cca-s1a,d1,a1), and -flex denotes Class 5 flexible copper stranding that bends easily inside tight electrical risers where rigid FR-N1X1G1-R cannot.

In Dutch and Benelux projects, YMz1Kf and YMvKf (0.6/1 kV and 1.8/3 kV) are the Class 5 flexible (f = *flexibel*) counterparts to rigid YMz1K and YMvK: Ym denotes 90 °C XLPE core insulation; z1 in YMz1Kf denotes a low-smoke zero-halogen (LSZH) outer sheath certified to CPR B2ca-s1a,d1,a1 / Cca-s1a,d1,a1 (>80% light transmittance); while v in YMvKf denotes a special fire-retardant PVC outer sheath certified to CPR Cca-s2,d2,a3 (EN 50399 bunched fire test). Compare with Spanish/EuropeanRZ1-K (AS) 0.6/1 & 1.8/3 kV flexible LSZH cableor French aluminumU-1000 AR2V / RV Al feeder cable.

Typical Plant, Machine & Infrastructure Circuits

  • FR-N1X1G1-flex (0.6/1 kV & 1.8/3 kV) is specified across France and Francophone markets for hospital switchboards, metro stations, commercial towers, and solar PV string-inverter AC/DC runs where NF C 15-100 requires C1/Cca halogen-free cables with tight 5 × OD routing.
  • YMz1Kf and YMvKf (1×1.5 mm² to 1×630 mm² and 2×1.5 to 37G2.5 mm²) serve Dutch and Benelux water treatment plants, maritime ports, greenhouse cogeneration, data centers, and rooftop/utility solar installations requiring flexible KEMA/NEN-type cabling.

FR-N1X1G1-flex Specification & Selection FAQ

What is the difference between FR-N1X1G1-flex and U-1000 R2V?

First, FR-N1X1G1-flex (built to NF C 32-323) has a low-smoke zero-halogen (G1) outer sheath rated CPR Cca-s1a,d1,a1 for public buildings, whereas U-1000 R2V has a standard PVC (R2V) sheath. Second, FR-N1X1G1-flex uses a Class 5 flexible copper conductor (-flex) instead of a rigid Class 1/2 conductor.

What is the difference between Dutch YMz1Kf and YMvKf?

In Dutch NEN nomenclature, both YMz1Kf and YMvKf have 90 °C XLPE insulation (Ym) and Class 5 flexible copper conductors (Kf). However, YMz1Kf has a halogen-free LSZH outer sheath (z1, CPR B2ca/Cca-s1a,d1,a1), whereas YMvKf has a flame-retardant PVC outer sheath (v, CPR Cca-s2,d2,a3).

Why are 1.8/3 kV versions of FR-N1X1G1-flex, YMz1Kf, and YMvKf used in solar PV and VFD installations?

Modern 1,500 V DC utility/rooftop string inverters and 800 V AC transformerless inverters exceed the 0.6/1 kV (1.5 kV DC) voltage ceiling during cold-morning open-circuit or VFD switching transients. Specifying the 1.8/3 kV (3.6 kV AC / 5.4 kV DC max) version provides double insulation safety.

Can FR-N1X1G1-flex, YMz1Kf, and YMvKf be installed outdoors and underground?

Yes. All three cable families pass UV weathering tests (EN 50618 / UNE 211605), AD5–AD7 water resistance, and are approved for open-air cable trays, conduits, and buried duct installations.

Dimensional, ampacity, and voltage-drop specifications for French NF C 32-323 FR-N1X1G1-flex and Dutch YMz1Kf / YMvKf 0.6/1 kV and 1.8/3 kV cables.

TEBAOFLEX® — FR-N1X1G1-flex (NF C 32-323), YMz1Kf & YMvKf 0.6/1–1.8/3 kV Power Cable

FR-N1X1G1-flex (NF C 32-323) & YMz1Kf (B2ca / Cca LSZH) 0.6/1 kV & 1.8/3 kV Specifications
Model & Voltage Formation (mm²) Overall OD (mm) Approx. Weight (kg/km) Ampacity Open Air 30 °C (A) Ampacity Buried 20 °C (A) Voltage Drop (V/A·km) CPR Euroclass
YMz1Kf / FR-N1X1G1 0.6/1 kV 1 × 6 8.2 120 68 58 8.41 B2ca-s1a,d1,a1
YMz1Kf / FR-N1X1G1 0.6/1 kV 1 × 16 10.1 225 124 100 3.08 B2ca-s1a,d1,a1
YMz1Kf / FR-N1X1G1 0.6/1 kV 1 × 35 12.5 405 200 154 1.41 B2ca-s1a,d1,a1
YMz1Kf / FR-N1X1G1 0.6/1 kV 1 × 70 16.2 740 310 225 0.705 B2ca-s1a,d1,a1
YMz1Kf / FR-N1X1G1 0.6/1 kV 1 × 120 20.1 1,210 437 303 0.422 B2ca-s1a,d1,a1
YMz1Kf / FR-N1X1G1 0.6/1 kV 1 × 240 27.5 2,375 674 445 0.228 B2ca-s1a,d1,a1
FR-N1X1G1 / YMz1Kf 0.6/1 kV 2 × 2.5 9.6 140 36 35 20.4 B2ca / Cca-s1a,d1,a1
FR-N1X1G1 / YMz1Kf 0.6/1 kV 3G 2.5 10.5 165 36 35 20.4 B2ca / Cca-s1a,d1,a1
FR-N1X1G1 / YMz1Kf 0.6/1 kV 4G 6 14.2 345 54 51 7.30 B2ca / Cca-s1a,d1,a1
FR-N1X1G1 / YMz1Kf 0.6/1 kV 5G 10 18.0 615 75 69 4.23 B2ca / Cca-s1a,d1,a1
FR-N1X1G1 / YMz1Kf 0.6/1 kV 5G 35 28.8 1,860 162 138 1.22 Cca-s1a,d1,a1
FR-N1X1G1 / YMz1Kf 1.8/3 kV 1 × 16 11.5 255 128 104 3.08 B2ca / Cca-s1a,d1,a1
FR-N1X1G1 / YMz1Kf 1.8/3 kV 1 × 50 16.2 590 250 185 1.01 B2ca / Cca-s1a,d1,a1
FR-N1X1G1 / YMz1Kf 1.8/3 kV 1 × 120 21.8 1,290 445 310 0.422 B2ca / Cca-s1a,d1,a1
FR-N1X1G1 / YMz1Kf 1.8/3 kV 1 × 240 28.5 2,390 685 450 0.228 B2ca / Cca-s1a,d1,a1

TEBAOFLEX® — FR-N1X1G1-flex (NF C 32-323), YMz1Kf & YMvKf 0.6/1–1.8/3 kV Power Cable

YMvKf 0.6/1 kV & 1.8/3 kV (CPR Cca-s2,d2,a3 Flame-Retardant XLPE/PVC) Representative Specifications
Model & Voltage Formation (mm²) Overall OD (mm) Approx. Weight (kg/km) Ampacity Open Air 30 °C (A) Ampacity Buried 20 °C (A) CPR Euroclass
YMvKf 0.6/1 kV 1 × 16 10.0 220 124 100 Cca-s2,d2,a3
YMvKf 0.6/1 kV 1 × 50 14.5 535 245 182 Cca-s2,d2,a3
YMvKf 0.6/1 kV 1 × 150 22.3 1,495 500 340 Cca-s2,d2,a3
YMvKf 0.6/1 kV 3G 2.5 10.4 160 36 35 Cca-s2,d2,a3
YMvKf 0.6/1 kV 5G 6 15.5 420 54 51 Cca-s2,d2,a3
YMvKf 0.6/1 kV 5G 16 21.8 945 100 88 Cca-s2,d2,a3
YMvKf 1.8/3 kV 1 × 25 12.8 345 165 132 Eca / Cca
YMvKf 1.8/3 kV 1 × 95 19.5 990 385 270 Eca / Cca
YMvKf 1.8/3 kV 1 × 185 25.3 1,815 575 380 Eca / Cca

Selection guide: Specify FR-N1X1G1-flex (French NF C 32-323 LSZH), YMz1Kf (Dutch B2ca/Cca LSZH) or YMvKf (Dutch Cca PVC), voltage rating (0.6/1 kV or 1.8/3 kV), and core formation (1×1.5 to 1×630 mm² or 2×1.5 to 37G2.5 mm²).

Ordering & Quotation Checklist: Request a factory quotation for NF C 32-323 FR-N1X1G1-flex, Dutch YMz1Kf (B2ca/Cca LSZH) or YMvKf (Cca) 0.6/1 kV and 1.8/3 kV flexible XLPE cables.

RZ1-K (AS) 0.6/1 & 1.8/3 kV, SZ-K, Z1Z1-K & TXXI Flexible LSZH Power Cable

RZ1-K (AS) 0.6/1 & 1.8/3 kV, SZ-K, Z1Z1-K & TXXI Flexible LSZH Power Cable

RZ1-K (AS) 0.6/1 kV, RZ1-K (AS) 1.8/3 kV, SZ-K (AS), Z1Z1-K (AS) & TXXI

VIEW PRODUCT »

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for FR-N1X1G1-flex (NF C 32-323), YMz1Kf & YMvKf 0.6/1–1.8/3 kV Power Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.