Marine & Offshore
LS3SU shielded triad cable and SIA GL constructions for shipboard power, control and communication circuits and offshore electrical systems.

Heavy-duty rubber cables for mining, port cranes, submersible pumps, EV charging, elevators and marine duty. Pick a family to filter the range.
TEBAOFLEX marine and offshore cables are built to the ordered design: LS3SU Watertight Shipboard Cable, a shielded multi-triad cable with XLPE insulation and a cross-linked polyolefin jacket for power, control, communication and 400 Hz circuits; SIA GL Cable, a shipboard designation supplied to match the vessel specification for distribution and equipment connections; and SiF Silicone Cable, a flexible single-core silicone wire for internal wiring of elevated-temperature equipment. Voltage, dimensions and approvals are confirmed on the project datasheet.
Showing all 3 results
What sets TEBAOFLEX Marine & Offshore Cable apart in service.
LS3SU has a braided copper shield around each triad; LS3SUS variants may add an overall shield for screened shipboard circuits.
LS3SU is described for shipboard power, control, communication and 400 Hz circuits where shielded service is required.
LS3SU uses stranded copper conductors, cross-linked polyethylene insulation and a cross-linked polyolefin jacket with surface marking.
SIA GL construction is matched to the vessel specification: conductor count, voltage, insulation system, sheath, and any screen, braid or armour.
SIA GL sheaths are selected from marine low-smoke, flame-retardant or oil-resistant compounds to suit the vessel's fire and smoke requirements.
SiF single-core silicone wire stays flexible across a broad temperature range for internal wiring in elevated-temperature equipment.
Capabilities across the Marine & Offshore Cable range; each product page lists the exact construction, rating and reference standard.
| Specification | Available options |
|---|---|
| Product types | Shielded multi-triad shipboard cable (LS3SU Watertight Shipboard Cable); shipboard cable to vessel specification (SIA GL Cable); single-core silicone wire (SiF Silicone Cable) |
| Rated voltage | Project-specific, confirmed on the datasheet; common SiF variants are low-voltage appliance wires |
| Conductor | Stranded copper, commonly 18 AWG in the triads (LS3SU); copper sized for circuit current and installation (SIA GL); flexible fine-stranded tinned or bare copper (SiF) |
| Core layout | 3 to 44 shielded triads in the common construction (LS3SU); single-core or multicore (SIA GL); single-core (SiF) |
| Insulation | XLPE (LS3SU); marine-rated thermoset or thermoplastic as specified (SIA GL); silicone rubber (SiF) |
| Sheath | Cross-linked polyolefin (XLPO) with surface marking (LS3SU); marine low-smoke, flame-retardant or oil-resistant compound as required (SIA GL); no separate sheath on standard single-core SiF |
| Screening / armour | Braided copper shield on each triad, overall shield on LS3SUS variants (LS3SU); optional screen, braid or armour (SIA GL) |
| Installation duty | Typically non-flexing shipboard service (LS3SU); flexible installation, with bending radius depending on diameter and routing (SiF) |
| Reference standards | MIL-C-24643/35 as common public reference (LS3SU); IEC/VDE appliance-wire requirements (SiF); governing shipboard specification and classification society confirmed per project (SIA GL) |
| Documents | Datasheet, test report and certification documents for the exact model on request at RFQ stage |
Where Marine & Offshore Cable from TEBAOFLEX is installed.
LS3SU shielded triads for shipboard power, control and lighting circuits where shielded 400 Hz service is required.
02LS3SU is listed for shipboard combat systems and interior communications, with a braided copper shield around each triad.
03SIA GL for marine switchboards, shipboard distribution and control panels, with the construction matched to the vessel system voltage and circuit design.
04SIA GL for machinery rooms and deck equipment, with optional screen, braid or armour where EMC or mechanical protection is required.
05SIA GL is also listed for offshore electrical systems; confirm classification society, fire performance, smoke and halogen limits and water exposure.
06SiF single-core silicone wire for internal wiring of heating appliances, luminaires, switchboards, control cabinets, motors and industrial machinery.
Four decisions specify the right cable the first time; send them with your RFQ and our engineers confirm the type designation.
Power, control, communication or 400 Hz circuits, and the vessel system voltage, which is project-specific and confirmed on the datasheet.
Shielded triad count for LS3SU, 3 to 44 in the common construction, or single-core or multicore layout and cross-section for SIA GL.
Individual or overall shields, optional braid or armour, and a low-smoke, flame-retardant or oil-resistant sheath to meet the vessel's fire, smoke and halogen limits.
The governing shipboard specification, classification society approval and watertight test scope, and whether the installation is fixed or flexing.
Cable packages engineered around the application, not just the cable.

LS3SU shielded triad cable and SIA GL constructions for shipboard power, control and communication circuits and offshore electrical systems.

Silicone and high-temperature cables for metallurgy; SiF silicone wire for internal wiring of heaters, furnaces and other hot equipment.

Umbilical, tether, floating and zero-buoyancy cables for underwater ROVs and other subsea robotics.
Recent deliveries from the TEBAOFLEX project team.
ISO 9001 quality management for cable production; ISO 14001 and ISO 45001 for sales and related management. UL and cUL (flexible cord), VDE (EN 50525-2-21), Korea KC, China MA and US MSHA approvals cover the certified types; CE is a third-party verification of conformity (VoC).




From compound to shipment, the production steps and routine tests behind each cable length.
EPR, CPE, PUR and silicone compounds are mixed and tested for hardness, tensile strength and elongation before use.
Tinned or bare copper is bunched and rope-stranded to Class 5/6 flexibility for trailing and reeling duty.
Cores are extruded and continuously vulcanised; wall thickness and spark tests are recorded on every length.
Cores, earth conductors, pilot and fibre-optic elements are laid up with the fillers and screens the type designation requires.
Reinforced double-sheath constructions are extruded and cured for abrasion, oil and tear resistance.
Conductor resistance, voltage withstand and insulation resistance tests at the levels set by the referenced standard.
Bending, tensile, hot-set, ozone and flame tests according to the referenced standard.
Metre marking, drum packing and documentation for worldwide project delivery.
Five-stage quality assurance from incoming copper to the packed drum.
Every batch of copper rod, rubber compound and reinforcing material is checked before it reaches the line.
Stranding, insulation extrusion, core assembly and sheathing run under recorded process parameters.
Finished lengths go through the routine tests required by the referenced VDE, ICEA, IEC or NEK standard.
Samples from production are tested for the duty a mining, crane or submersible cable will actually see.
Before packing, the cable is checked against the order and the flame-performance requirement of its standard.
TEBAOFLEX CABLE, No.77 Wusongbang Road, Taicang, Suzhou.




Selection and application guides from the TEBAOFLEX engineering team.

PR I is a 96-hour oil immersion, PR II is 1,440 hours with a higher pass mark. What the two UL ratings prove, and how to specify oil duty.
Read more
Silicone, PTFE, PFA, FEP and mica-glass compared by what limits each in service, and why the conductor plating often sets the real temperature ceiling.
Read more
RFOU and BFOU cable designations decoded layer by layer: what R, F, O and U name, how (i) and (c) screening differs, and which IEC 60092 part applies.
Read moreQuick answers about Marine & Offshore Cable from our engineers.
LS3SU is a shielded multi-triad marine cable for shipboard power, control, communication and 400 Hz circuits. The common construction uses stranded copper conductors, cross-linked polyethylene insulation, a braided copper shield around each triad and a cross-linked polyolefin jacket. It is a construction designation rather than one size: triad count, conductor size, dimensions, voltage and qualification depend on the ordered design.
Common public references describe 3 to 44 shielded triads with 18 AWG stranded copper conductors, three conductors per triad, cabled with fillers and binder tape. Jacket thickness, outside diameter and weight vary with triad count and with LS3SU or LS3SUS construction; LS3SUS variants may add an overall shield. Confirm the exact size and rating on the project datasheet.
The common public reference is MIL-C-24643/35. Confirm the exact revision, qualification, watertight test and approval scope for the supplied cable at RFQ stage. LS3SU is typically used in non-flexing shipboard service, so also state whether the installation involves any flexing, together with the routing and the fire and smoke requirements of the vessel.
SIA GL is a marine and shipboard cable designation for vessel electrical distribution and equipment connections. Its construction depends on conductor count, voltage, insulation system, sheath, armour or screen and classification requirements. TEBAOFLEX reviews the vessel specification and supplies a matching construction for marine routing, control or power duties, with project documentation for the governing shipboard specification and test standards.
SiF is a flexible single-core wire with silicone rubber insulation for internal equipment wiring in elevated-temperature environments, such as heating appliances, luminaires, switchboards, control cabinets, motors and industrial machinery. The standard form has no separate outer sheath, so protect the insulation from sharp edges, excessive abrasion and incompatible chemicals. Common variants are low-voltage appliance wires; confirm the exact voltage, temperature range and standard.
Send the core count, cross-section, voltage, length, installation method, environment, motion duty and required standards. For shipboard cables, add the governing shipboard specification, classification society, fire performance, smoke and halogen limits and water exposure. TEBAOFLEX will confirm the construction and provide the applicable datasheet; request test and certification documents for the exact model at RFQ stage.
A special-cable manufacturer in Taicang, Suzhou, making heavy-duty and special cables since 2014.
UL and cUL, VDE, Korea KC, China MA and US MSHA approvals for the certified types, CE verification of conformity, and ISO 9001 quality management.
More than 200 sets of advanced production and test equipment at home and abroad, from compounding to final electrical testing.
Constructions engineered to VDE, ICEA, IEC and NEK 606 standards and checked against the real duty cycle of your equipment.
0.6/1 kV to 35 kV heavy-duty rubber cables, reeling and festoon crane cables, submersible, marine, ROV and high-temperature cables.
Special constructions, fibre-optic elements, colours, printing and lengths built to the specification of your project.
Cables working in tunnel engineering, marine and offshore equipment, mining, petrochemical, steel and urban construction projects around the world.
Send us the equipment, voltage, cores and operating conditions and our engineers will propose a cable construction and quotation.