YY Control Cable 300/500V: Flexible PVC, Numbered Cores, 0.75 to 2.5 mm²
YY control cable is a flexible, unscreened 300/500 V PVC multicore cable for machine tools, conveyors and control cabinets. Compare the 0.75 to 2.5 mm² constructions below, with numbered cores and a protective earth where specified, and request a quote by core count and length.
- Rated voltage300/500 V
- ConductorClass 5 flexible bare copper
- Insulation / sheathPVC / grey PVC
- Core identificationBlack, white numbers + G/Y
- Typical sizes0.75 to 2.5 mm²
- Temperature (flexing)-5 °C to +70 °C
- Min. bending radius12.5 × outer diameter
- ScreenNone (unscreened)
Request a quotation: For a YY control cable quote, send the number of cores, cross-section, whether a green/yellow protective earth is required, total length and drum lengths, and destination. State any movement, oil exposure or outdoor routing so the construction can be checked before ordering.
YY Core Identification & Ratings
- Type: PVC Control & Data Cable
- Rated voltage: 300/500 V
- Conductor: Class 5 flexible bare copper
- Insulation / sheath: PVC / grey PVC
Electrical, Thermal & Mechanical Bend Limits
- Core identification: Black, white numbers + G/Y
- Typical sizes: 0.75 to 2.5 mm²
- Temperature (flexing): -5 °C to +70 °C
- Min. bending radius: 12.5 × outer diameter
- Screen: None (unscreened
YY Conductor, Insulation & Sheath Build
YY is a round multicore cable with a single PVC sheath and no screen or armour. The numbered cores are laid up in layers, which keeps the cable flexible and the outer diameter small for its core count.
- Conductor: plain annealed copper, Class 5 flexible to IEC 60228, for routing through cabinets and machine frames.
- Insulation: PVC (TI2) on each core; black cores printed with white numbers, plus a green/yellow earth core from three cores.
- Layup: cores stranded together in layers to a round, compact bundle.
- Outer sheath: grey PVC (TM2) for abrasion protection in dry and damp indoor areas.
- Screen: none; select a screened control cable for EMC duties, or the steel-braidedYSLYSYwhere mechanical protection is needed.
Primary Electrical & Mechanical Performance
- Cable type: Unscreened flexible PVC/PVC multicore control cable with numbered cores.
- Voltage data: 300/500 V rated voltage.
- Temperature: -5 °C to +70 °C when flexed; -15 °C to +70 °C in fixed installation; do not install below -5 °C.
- Sizes and bending: Typical sizes 0.75 to 2.5 mm²; minimum bending radius 12.5 × outer diameter when flexed.
Industrial Oil, Flame & Environmental Protection
- Machine tools and conveyors: Interconnecting control cable for machine tools, conveyors, assembly and production lines.
- Numbered cores: Black cores with white numbers and a green/yellow earth from three cores.
- Flexible Class 5 copper: Fine-stranded conductors for routing through cabinets, ducts and machine frames.
- Protected environments: For dry and damp indoor areas; outdoors only where shielded from sunlight.
IEC / EN / VDE / UL Reference Standards
- Construction reference: Built generally to BS EN 50525-2-11 (formerly BS 6500) practice for flexible PVC cables, with numbered cores for control use.
- Conductor reference: Plain copper conductors to IEC 60228 (BS EN 60228) Class 5.
- Materials: PVC insulation type TI2 to EN 50363-3 and PVC sheath type TM2 to EN 50363-4-1.
- Voltage scope: Rated 300/500 V for control and signal circuits.
- Approvals: National standard marking, flame-test reports (IEC 60332-1-2) and regulatory requirements are confirmed and quoted per order.
Industrial Cable Selection & Routing Guides

YY Industrial Installation & Routing Guide
YY control cable is a flexible PVC multicore control cable for low-voltage equipment wiring, machine tools, automation and general industrial control. Both the core insulation and the outer sheath are PVC, which is what the two letters Y stand for, and the cable has no screen or braid. It is rated 300/500 V and uses Class 5 flexible copper conductors.
The cores are black with white numbers, and from three cores upward one core is green/yellow for the protective earth, so long multicore runs can be terminated by number. The YY designation is used broadly in international trade, and German catalogues list a closely comparable construction as YSLY. Conductor class, voltage, colour coding, temperature and approvals are confirmed on the datasheet issued with the quotation.
Typical Plant, Machine & Infrastructure Circuits
- YY is the general-purpose interconnecting cable of the machine shop and the control room: between control cabinets and machine tools, along conveyors and assembly lines, to sensors, valves and small motors, and inside measuring and regulating equipment. The numbered cores make it easy to follow a circuit diagram when one cable carries many separate control signals.
- It suits fixed installation and free movement without tensile load in dry and damp indoor areas and other protected environments. The PVC sheath is not UV resistant, so outdoor runs need trunking or another sunlight barrier. Confirm oil, UV, water, drag-chain, torsion and reeling requirements before using YY in demanding motion applications; where the cable needs mechanical protection, the steel-braidedYSLYSY cableis the armoured relative.
YY Specification & Selection FAQ
What does YY mean on a control cable?
The two letters describe the materials: Y for PVC core insulation and Y for a PVC outer sheath. A YY cable has no screen or braid. The same naming adds C for a tinned copper braid screen (CY) or S for a galvanised steel wire braid (SY).
What is the difference between YY, CY and SY cable?
All three share the same numbered PVC cores. CY adds a tinned copper braid under the sheath to screen against electrical interference, and SY adds a galvanised steel wire braid for mechanical protection under a clear outer sheath. Our steel-braided version is theYSLYSY cable.
YY or LiYY: which one do I need?
YY is a 300/500 V control cable with numbered cores from 0.75 mm² upward.LiYYis a smaller data and signal cable with DIN 47100 colour-coded cores and a 250 V peak operating voltage, used inside electronic equipment. Choose YY when the cable feeds contactors, valves, small motors or other mains-voltage control circuits.
Can YY be used in drag chains or outdoors?
YY is intended for fixed installation and free movement without tensile load. It is not designed for continuous drag-chain, torsion or reeling duty, and its PVC sheath is not UV resistant, so outdoor runs must be protected from sunlight. Tell us the motion and environment and we will propose a suitable construction.
What should I send for a quotation?
Send the core count and cross-section, numbered or colour-coded cores, the length or drum lengths, the installation method and environment, any motion duty, and the standards or markings your project requires.
Typical values for YY constructions. The final construction is confirmed on the TEBAOFLEX datasheet issued with your quotation.
TEBAOFLEX® — Electrical, mechanical and material data
| Parameter | Value |
|---|---|
| Designation | YY = PVC core insulation and PVC outer sheath, unscreened |
| Rated voltage | 300/500 V |
| Conductor | Plain annealed copper, flexible, IEC 60228 Class 5 |
| Core insulation | PVC compound type TI2 (EN 50363-3) |
| Core identification | Black with white numbers; green/yellow earth from 3 cores; colour-coded cores on request |
| Outer sheath | PVC compound type TM2 (EN 50363-4-1), grey |
| Screen | None |
| Temperature, flexing | -5 °C to +70 °C |
| Temperature, fixed installation | -15 °C to +70 °C |
| Installation temperature | Not below -5 °C |
| Minimum bending radius, flexing | 12.5 × outer diameter |
| UV resistance | Not UV resistant; protect from direct sunlight outdoors |
| Environment | Dry and damp indoor areas; light mechanical stress |
TEBAOFLEX® — YY typical constructions
| Cores × size | Max. conductor resistance at 20 °C | Approx. outer diameter | Approx. weight |
|---|---|---|---|
| 2 × 0.75 mm² | 26.0 Ω/km | 5.2 mm | 46 kg/km |
| 3 × 0.75 mm² | 26.0 Ω/km | 5.5 mm | 54 kg/km |
| 4 × 0.75 mm² | 26.0 Ω/km | 6.1 mm | 67 kg/km |
| 7 × 0.75 mm² | 26.0 Ω/km | 7.2 mm | 100 kg/km |
| 12 × 0.75 mm² | 26.0 Ω/km | 9.5 mm | 165 kg/km |
| 3 × 1.0 mm² | 19.5 Ω/km | 5.9 mm | 68 kg/km |
| 4 × 1.0 mm² | 19.5 Ω/km | 6.6 mm | 84 kg/km |
| 7 × 1.0 mm² | 19.5 Ω/km | 7.8 mm | 125 kg/km |
| 3 × 1.5 mm² | 13.3 Ω/km | 6.7 mm | 88 kg/km |
| 4 × 1.5 mm² | 13.3 Ω/km | 7.5 mm | 110 kg/km |
| 7 × 1.5 mm² | 13.3 Ω/km | 9.1 mm | 175 kg/km |
| 3 × 2.5 mm² | 7.98 Ω/km | 7.9 mm | 125 kg/km |
| 4 × 2.5 mm² | 7.98 Ω/km | 8.7 mm | 160 kg/km |
Selection guide: before ordering, ask our engineers to confirm the core count, cross-section and core identification, the voltage marking, the temperature range and bending radius for your installation, and any oil, UV, drag-chain or flame-test requirement. Outer diameter and weight in the table are approximate.
Ordering & Quotation Checklist: Send the core count, cross-section, length, installation method, environment, motion duty and required standards.
LiYY unscreened data cable
For color-coded electronic signal wiring; check its different voltage and size range.
LiYCY screened data cable
For low-frequency signal circuits needing a copper braid screen; verify the electrical rating.
Compare PVC control and data cable families
Start with the circuit voltage, core identification, screen requirement and installation method. Compare the cable families before sending your specification.
Request Quotation & Datasheet for This Cable
Need factory pricing, cross-section drawing or a full PDF datasheet for YY Control Cable 300/500V: Flexible PVC, Numbered Cores, 0.75 to 2.5 mm²? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.
- ISO 9001 Factory Direct
- MOQ 50 m (Custom Builds)
- 24h Engineering Reply