DIN 47100 Color Code Chart: Core Sequences, VDE 0293-308 & LiYY/YY Selection
Engineering reference for DIN 47100 core identification (1 to 44 unique cores, twisted pairs, and core 45+ divergence), IEC 60757 color abbreviations, DIN VDE 0293-308 vs. EN 50334 control suffixes, and LiYY, LiYCY, YY, and CY selection.

- Color Standard
- DIN 47100 (1–44 Unique · 45+ Rules) & IEC 60757 Codes
- Control Standards
- DIN VDE 0293-308 (HD 308 S2) & DIN EN 50334 (-JZ / -OZ)
- Size Boundary
- 0.14–0.34 mm² VDE 0812 vs. 0.5–2.5 mm² IEC 60228 Class 5
- Screen & Sheath
- TCWB Braid (LiYCY/CY) vs. Unscreened (LiYY/YY) & LSZH
Industrial automation engineers rely on the DIN 47100 core color code when terminating multi-core data, sensor, and signal harnesses inside dense enclosures. Germany formally withdrew DIN 47100 in 1998. However, European cable factories still pair its color sequence with IEC 60757 letter codes, DIN VDE 0293-308, and DIN EN 50334 numbering rules. Explore construction options across our full PVC control and data catalog or compare unscreened TEBAOFLEX LiYY data and control cable.
1. How Does the DIN 47100 Color Code Identify Cores 1 to 44 and Cores Above 44?
DIN 47100 assigns ten solid colors to cores 1–10 and 34 two-color combinations to cores 11–44. Above 44 cores, manufacturers either repeat from white or add a third black ring. Issued in January 1988 under DIN 47100 (DIN Media), the standard was withdrawn in November 1998 without a direct replacement. Cable factories still specify DIN 47100 on LiYY, LiYCY, and halogen-free LiHCH builds because 0.14–0.34 mm² insulation walls are too thin for durable ink numbering.
Wiring schematics pair these colors with IEC 60757:2021 (IEC Webstore) uppercase abbreviations such as WH, BN, GN, YE, GY, PK, BU, RD, BK, and VT. This international shorthand removes translation errors across harness drawings. Starting at core 11 (GYPK), the first letter pair identifies the base compound color. The second letter pair names the contrasting ring or longitudinal stripe.
Twisted-pair (TP) cables like LiYCY (TP) and LiHCH-TP group consecutive wires into balanced differential pairs. Pairs 1 to 3 assign WH + BN, GN + YE, and GY + PK. Pairs 4 to 6 follow with BU + RD, BK + VT, and GYPK + RDBU.

Triple-stripe printing on small diameters increases manufacturing scrap and slows field tracing. To preserve legibility, most modern production lines restart from core 1 (WH) once core count passes 44. Specialized non-repeating harnesses instead apply a third black (BK) ring from core 45 (WHBNBK) through core 60 (BNRDBK). Table 1 provides the complete 1–44 core map alongside twisted pairs and historical 45–60 notation.
| Core | Base & Stripe (Cores 1–22) | IEC 60757 | Core | Base & Stripe (Cores 23–44) | IEC 60757 | Pair / Core 45–60 Rule |
|---|---|---|---|---|---|---|
| 1 | White (solid) | WH |
23 | White-Red | WHRD |
Pair 1: 1 WH + 2 BN |
| 2 | Brown (solid) | BN |
24 | Brown-Red | BNRD |
Pair 2: 3 GN + 4 YE |
| 3 | Green (solid) | GN |
25 | White-Black | WHBK |
Pair 3: 5 GY + 6 PK |
| 4 | Yellow (solid) | YE |
26 | Brown-Black | BNBK |
Pair 4: 7 BU + 8 RD |
| 5 | Grey (solid) | GY |
27 | Grey-Green | GYGN |
Pair 5: 9 BK + 10 VT |
| 6 | Pink (solid) | PK |
28 | Yellow-Grey | YEGY |
Pair 6: 11 GYPK + 12 RDBU |
| 7 | Blue (solid) | BU |
29 | Pink-Green | PKGN |
45 (3-color): WHBNBK |
| 8 | Red (solid) | RD |
30 | Yellow-Pink | YEPK |
46 (3-color): YEGNBK |
| 9 | Black (solid) | BK |
31 | Green-Blue | GNBU |
47 (3-color): GYPKBK |
| 10 | Violet (solid) | VT |
32 | Yellow-Blue | YEBU |
48 (3-color): RDBUBK |
| 11 | Grey-Pink | GYPK |
33 | Green-Red | GNRD |
49 (3-color): WHGNBK |
| 12 | Red-Blue | RDBU |
34 | Yellow-Red | YERD |
50 (3-color): BNGNBK |
| 13 | White-Green | WHGN |
35 | Green-Black | GNBK |
51 (3-color): WHYEBK |
| 14 | Brown-Green | BNGN |
36 | Yellow-Black | YEBK |
52 (3-color): YEBNBK |
| 15 | White-Yellow | WHYE |
37 | Grey-Blue | GYBU |
53 (3-color): WHGYBK |
| 16 | Yellow-Brown | YEBN |
38 | Pink-Blue | PKBU |
54 (3-color): GYBNBK |
| 17 | White-Grey | WHGY |
39 | Grey-Red | GYRD |
55 (3-color): WHPKBK |
| 18 | Grey-Brown | GYBN |
40 | Pink-Red | PKRD |
56 (3-color): PKBNBK |
| 19 | White-Pink | WHPK |
41 | Grey-Black | GYBK |
57 (3-color): WHBUBK |
| 20 | Pink-Brown | PKBN |
42 | Pink-Black | PKBK |
58 (3-color): BNBUBK |
| 21 | White-Blue | WHBU |
43 | Blue-Black | BUBK |
59 (3-color): WHRDBK |
| 22 | Brown-Blue | BNBU |
44 | Red-Black | RDBK |
60 (3-color): BNRDBK |
Sources: DIN 47100 (1988-01, withdrawn Nov 1998), IEC 60757:2021 color designation abbreviations, and DIN VDE 0812 construction practice.
2. How Does DIN 47100 Differ From DIN VDE 0293-308 and DIN EN 50334 Control Suffixes?
DIN 47100 covers ungrounded electronic signal cores, whereas DIN VDE 0293-308 (HD 308 S2) and DIN EN 50334 govern 300/500 V power and control cables. Full phase, neutral, and protective earth sequences appear inside our HD 308 S2 and DIN VDE 0293-308 power cable color code guide. Two-letter suffixes on families like YSLY-JZ / YSLY-OZ control cable declare protective earthing and core marking.
The first suffix letter defines earth presence. Letter J (with) adds one green-yellow (GNYE) protective conductor in the outer layer, denoted with G (4G1.5 mm²). Letter O (ohne, without) omits the earth wire and uses × (4×1.5 mm²).
The second letter separates color standards from number printing. Under DIN VDE 0293-308 (DIN Media), suffix -B (bunt, colored) covers 2–5 core cables. Two-core -OB uses BU, BN, three-core -OB uses BN, BK, GY, and four-core -OB uses BU, BN, BK, GY. Five-core -OB repeats BK, while -JB adds GNYE across 3–5 cores.
Above five cores, and across multi-core numbered control designs, cables follow DIN EN 50334 (DIN Media) (-Z for Ziffern). Numbered -OZ cables start at two cores (2×) with consecutive white digits on black insulation, while -JZ adds GNYE from three cores (3G+). Always verify the full designation before panel strip-out, and compare British versus continental naming in our YY vs SY vs CY control cable guide. Table 2 summarizes both systems.
| Selection Parameter | DIN 47100 (Signal & Data) | DIN VDE 0293-308 -JB / -OB (2–5 Cores) |
DIN EN 50334 -JZ (3+) / -OZ (2+ Cores) |
|---|---|---|---|
| Governing Cable Families | LiYY, LiYCY, LiHH, LiHCH, Li2YCY |
YSLY-JB, YSLY-OB, 3G–5G flexible leads |
YY, YSLY-JZ, CY, SY, HSLH, H05VV5-F |
| Core Visual Method | 10 solid + 34 bi-color cores (1–44) |
Harmonized colors (BU, BN, BK, GY) |
Black cores printed with white numbers (1, 2, 3...) |
Green-Yellow Earth (PE) |
Omitted in standard DIN 47100 |
-JB includes GNYE (3–5 cores); -OB omits |
-JZ includes GNYE (3G+); -OZ omits GNYE (2×+) |
| Size Notation Example | 7 × 0.25 mm² or 4 × 2 × 0.34 mm² (TP) |
5G1.5 mm² (-JB) or 3×1.5 mm² (-OB) |
12G1.0 mm² (-JZ: 11 numbered + GNYE) |
| Typical Conductor Sizes | 0.14 mm² to 1.5 mm² (signal focus) |
0.75 mm² to 25 mm²+ feeder cords |
0.5 mm² to 35 mm² control & power |
High-Count Rule (≥ 6 cores) |
Continues unique colors up to 44 cores |
Transitions to EN 50334 numbered cores |
Continues white numerals on black cores |
Sources: DIN 47100, DIN VDE 0293-308 (2003-01), DIN EN 50334 (2001-10), and TEBAOFLEX YY / YSLY-JZ / LiYY rules.
3. When Should Engineers Specify LiYY and LiYCY vs. YY, CY, or LSZH Control Families?
Specify LiYY or LiYCY for compact DIN 47100 signal harnesses. Upgrade to YY, CY, or LSZH families for 300/500 V control circuits or halogen-free zones. Although PVC signal and control jackets look similar externally, their test voltages, conductor sizes, shielding layers, and compound ratings target distinct duties.

Evaluate electromagnetic noise and working circuit voltage first. Unscreened LiYY spans 0.14–0.75 mm² fine-stranded copper for quiet indoor panels needing minimal outer diameter (compare VDE 0812 below 0.5 mm² with 0.5–300 mm² flexible limits and DIN 46228 ferrules in our IEC 60228 conductor classes guide). Because LiYY identifies a family construction rather than a universal voltage class, confirm circuit voltage (AC or DC), marking, ambient temperature, and finished diameter on the quotation drawing.
Around variable-frequency drives (VFDs) or servo feeders, select tinned-copper braided LiYCY built to VDE 0812 PVC TI2/TM2. It carries a 350 V peak rating at 0.14 mm² or 500 V peak at ≥ 0.25 mm². Review direct signal-to-screen trade-offs in our LiYY vs LiYCY specification guide.
Circuits driving 300/500 V (U0/U) AC contactor coils or solenoid manifolds require IEC 60228 Class 5 control constructions. Choose unscreened YY (0.75–2.5 mm²) or YSLY-JZ (4,000 V or 2,000 V test voltage) in enclosed cabinets. Upgrade to braided CY (TCWB ≥ 70%–85%, 2,000–4,000 V test) or YSLYCY-JZ where EMC immunity is required. Step into specialized builds for swarf, smoke density, or differential fieldbuses:
- Swarf & Crush Defense (
SY/YSLYSY): Select galvanized steel wire braid (GSWB) under transparent PVC where chip conveyors or foot traffic threaten abrasion. - Halogen-Free Public Zones (
LiHCH/HSLH): SpecifyLSZHcompounds meetingIEC 60754-1/2acidity andIEC 61034-2smoke limits in airports, hospitals, or enclosed rail shafts. - Coolant Exposure &
RS-485Data Buses: Use oil-resistantH05VV5-F(DIN EN 50525-2-51) near cutting fluids orHigh-Flex PVCin drag chains. Choose low-capacitancePE(2Y)Li2YCY (PiMF)for long serial trunks.
Table 3 consolidates live TEBAOFLEX product families covered across both coding standards.
| Cable Family | Core Identification | Voltage Basis (Per Family Spec) | Insulation / Outer Sheath | Metallic Screen / Armor | Primary Duty |
|---|---|---|---|---|---|
LiYY (0.14–0.75 mm²) |
DIN 47100 color code |
Confirm circuit AC/DC V in RFQ |
PVC / gray PVC |
None (unscreened) | Compact indoor panel & sensor wiring |
| LiYCY Screened Cable | DIN 47100 without repetition |
350 V (0.14) / 500 V peak (≥ 0.25); 1.2 kV test |
PVC TI2 / gray PVC TM2 (IEC 60332-1-2) |
Tinned copper wire braid over foil | EMC-protected signal, encoder & control (0.14–1.5 mm²) |
| LiHCH / LiHH LSZH Cable | DIN 47100 color code |
350 V (0.14) / 500 V peak (0.25–1.5) |
LSZH halogen-free (IEC 60754 / 61034) |
None (LiHH) or TCWB (LiHCH) |
Low-smoke cleanrooms, airports & rail cabinets |
| Li2YCY / Li2YCY-P PiMF | DIN 47100 paired (TP) |
1,500 V AC core/core (2,000 V screen) test |
PE (2Y) / gray PVC (or outdoor Yv) |
AL/PET + TCWB + optional PiMF (~45 nF/km) |
Long-distance RS-485, RS-422 & load cells |
| YY Control Cable | Black numbered + G/Y (3G+) |
300/500 V (U0/U) |
PVC TI2 / gray PVC |
None (unscreened) | Machine tools & assembly control (0.75–2.5 mm²) |
| CY Screened Control | EN 50334 numbered (JZ/OZ) |
300/500 V (U0/U), 2–4 kV test |
PVC TI2 / RAL 7001 TM2 |
Tinned copper wire braid (≥ 70%–85%) |
Screened VFD & PLC I/O control circuits |
| YSLYCY-JZ Screened PVC | EN 50334 numbered (JZ/OZ) |
300/500 V (U0/U), 4,000 V test |
PVC / silver-gray PVC |
Tinned copper wire braid (EMC) |
Continental-coded 0.5 mm²+ screened control |
| SY Steel-Braided Control | Black numbered + G/Y (JZ/OZ) |
300/500 V (U0/U) |
PVC inner bedding / transparent PVC |
Galvanized steel wire braid (GSWB) |
Mechanical swarf, impact & abrasion defense |
Sources: DIN 47100, DIN VDE 0812, DIN EN 50334, IEC 60332-1-2:2025, and TEBAOFLEX published product specifications.
4. How Do 0.14–0.34 mm² VDE 0812 Resistance Limits Compare With 0.5–2.5 mm² IEC 60228 Class 5?
IEC 60228:2023 (IEC Webstore) governs Class 5 copper from 0.5 mm² (39.0 Ω/km) downward in resistance to 2.5 mm² (7.98 Ω/km). Finer 0.14–0.34 mm² signal cores instead follow DIN VDE 0812 limits with higher DC resistance. When converting US drawings (26 AWG to 14 AWG) into metric sizes, confirm exact equivalents with our AWG to mm² converter.
Under IEC 60228 Class 5 plain copper at 20 °C, maximum DC resistance drops steadily across control sizes. Smaller cores reach 39.0 Ω/km (0.5 mm²), 26.0 Ω/km (0.75 mm²), and 19.5 Ω/km (1.0 mm²). Larger control conductors drop further to 13.3 Ω/km (1.5 mm²) and 7.98 Ω/km (2.5 mm²), while tinned copper carries slightly higher limits starting at 40.1 Ω/km (0.5 mm²).
By comparison, 0.14 mm² reaches 148 Ω/km and 0.25 mm² reaches 80.0 Ω/km on live LiYCY tables (zero-halogen LiHCH variants run near 138 Ω/km and 79 Ω/km). Meanwhile, 0.34 mm² commonly uses a 7-wire strand around 57 Ω/km under VDE 0812 practice. That puts 0.14 mm² at roughly 5.7× the cold DC resistance of 0.75 mm² YY control cores.
A 100 m two-wire 24 V DC loop (200 m conductor path) on 0.14 mm² adds roughly 29.6 Ω before thermal rise. Long DC solenoid coils or resistive sensors can therefore suffer actuation drop if sized purely by current tables. Verify loop resistance and actual load drop before locking cross-section using our conductor resistance calculator and voltage drop calculator.
5. How Should Panel Builders Terminate DIN 47100 Signal Screens and Avoid Common Substitution Errors?
Terminate LiYCY and CY tinned-copper braids through 360° nickel-plated EMC glands onto a clean earth rail. Never route mains power or RS-485 differential trunks over mismatched signal wire. Even compliant braided cable couples drive noise into PLC inputs when terminated as a long pigtail.

Strip a circumferential outer-jacket window directly above the gland plate and press the exposed copper braid evenly onto a continuous ground busbar. Twisting that braid into a narrow drain pigtail adds series inductance that compromises high-frequency shielding above megahertz drive edges. Confirm vertical flame propagation compliance on single panel runs under IEC 60332-1-2:2025 (IEC Webstore) 1 kW burner testing.
Negative Selection Boundary: Do not substitute 0.14–0.34 mm² LiYY signal cores into 230/400 V AC mains contactors or continuous drag chains. Specify a continuous-flex build for dynamic machine motion. Never treat galvanized steel wire braid on SY or YSLYSY as an EMC screen or protective earth path. Do not run standard PVC multicore LiYY on long RS-485 trunks where our RS-485 cable selection guide specifies controlled-impedance twisted pairs.
6. What Must Buyers Confirm Before Ordering DIN 47100 or Numbered Control Cables?
Specify core count, conductor cross-section, color or number convention, screening construction, circuit voltage (AC or DC), temperature limits, and cut length before requesting a quotation. Leaving any parameter assumed risks mismatched voltage marks or incompatible gland sealing diameters.
- Core Identification Standard: State explicitly whether the build requires
DIN 47100colors (no green-yellow), twisted pairs (TP),-JB/-OBphase colors, orEN 50334-JZ/-OZnumerals. - Core 45+ Identification Rule: For harnesses exceeding
44cores, clarify whether cores45and upward restart fromWHor follow three-color45–60(WHBNBK..BNRDBK) coding. - Voltage Mark vs. Test Level: Supply circuit operating voltage (
AC U0/Uvs.DCpeak) and required jacket print rather than relying on family initials alone. - EMC Screening & Gland Fit: Specify unscreened (
LiYY/YY),TCWBEMC braid (LiYCY/CY/YSLYCY),AL/PET+TCWB(Li2YCY), or steel braid (SY), matching gland bore diameters. - Conductor Resistance Margin: Check cold loop resistance across
0.14–2.5 mm²lengths and state exact cut lengths or drum packaging requirements. - Engineering & Quality Sign-Off: Before ordering, review our Taicang manufacturing background and certificates and compliance page. Then ask our engineers to confirm finished OD, bend radius, and drum sizing on your drawing.
CONTROL & SIGNAL RFQ DESK
Confirm Exact DIN 47100 Colors, Screening & Dimensions Before Ordering
Share your core count × size (0.14–2.5 mm²), color or number coding, screening type, and circuit voltage (AC or DC). Include ambient temperature limits and cut or drum quantities so TEBAOFLEX engineers can prepare a construction-specific quotation.
7. Frequently Asked Questions
What is the core color order for the first 10 cores in DIN 47100?
The first ten DIN 47100 cores use solid insulation colors matching IEC 60757 two-letter codes. Cores 1 through 5 are White (WH), Brown (BN), Green (GN), Yellow (YE), and Grey (GY). Cores 6 through 10 follow as Pink (PK), Blue (BU), Red (RD), Black (BK), and Violet (VT).
How do DIN 47100 cables identify cores 45 and above?
Triple-color stripes on fine 0.14–0.5 mm² walls often wear or misread in the field. Most modern factories therefore restart the DIN 47100 loop from core 1 (WH, BN, GN) at core 45. Strict non-repeating specifications instead add a third black ring (WHBNBK through BNRDBK) up to core 60.
Why does DIN 47100 exclude green-yellow while YY -JZ includes it?
DIN 47100 governs multi-core electronic signal and telecommunication wiring without a safety earth wire. YY and YSLY-JZ control cables follow DIN EN 50334. That standard pairs white-numbered black circuit cores with a green-yellow protective ground conductor starting at three cores (-JZ).
Does the LiYY designation guarantee a fixed 250 V rating or outer diameter?
No. LiYY identifies an unscreened fine-stranded copper PVC construction family whose printed voltage rating varies across regional specifications. Confirm circuit voltage (AC or DC), temperature limits, bend radius, and finished cable diameter directly on the TEBAOFLEX quotation drawing.
When should I switch from DIN 47100 LiYY or LiYCY to Li2YCY for RS-485?
Standard PVC LiYY and LiYCY multicores target low-frequency sensor and control I/O rather than controlled 120 Ω data trunks. For long or high-baud RS-485 and RS-422 lines, choose polyethylene (PE, 2Y) twisted-pair Li2YCY / Li2YCY-P PiMF cable to minimize capacitance and pulse rounding.