PROFINET Type A / Type B / Type C Cat5e & Cat6A Industrial Ethernet Cable

PROFINET Type A (solid conductor for fixed installation), Type B (7-wire stranded conductor for flexible routing and occasional movement) and Type C (extra-fine stranded conductor for continuous drag-chain, festoon and robotic torsion service) are 100 Ω industrial Ethernet cables engineered in accordance with PNO PROFINET Cabling and Interconnection Technology Guideline 2.008 and IEC 61156-5 / IEC 61156-6.

  • Application classesType A (fixed), Type B (flex), Type C (drag chain/robot)
  • Transmission categoriesCat5e Star-Quad (100 MHz) & Cat6A 4-Pair (500 MHz)
  • Characteristic impedance100 Ω ± 15 Ω (1–100 MHz / 1–500 MHz)
  • Core color codeCat5e Star-Quad: White, Yellow, Blue, Orange
  • EMC screeningSF/UTP (Al/PET foil + ≥85% CuSn braid) or S/FTP (PiMF)
  • Outer sheath & colorPVC, FRNC/LSZH or PUR in green (RAL 6018) or black
  • Rated voltage & test300 V / 600 V (UL 758 style); 2,000 V AC test voltage
  • Temperature & bend-40 to +80 °C; min bend 4×OD fixed / 7.5×OD drag chain

PROFINET Type A / Type B / Type C Signal & Bus Architecture

  • Type: PVC Control & Data Cable
  • Application classes: Type A (fixed), Type B (flex), Type C (drag chain/robot
  • Transmission categories: Cat5e Star-Quad (100 MHz) & Cat6A 4-Pair (500 MHz
  • Characteristic impedance: 100 Ω ± 15 Ω (1–100 MHz / 1–500 MHz

Impedance, Attenuation & Operating Limits

  • Core color code: Cat5e Star-Quad: White, Yellow, Blue, Orange
  • EMC screening: SF/UTP (Al/PET foil + ≥85% CuSn braid) or S/FTP (PiMF
  • Outer sheath & color: PVC, FRNC/LSZH or PUR in green (RAL 6018) or black
  • Rated voltage & test: 300 V / 600 V (UL 758 style); 2,000 V AC test voltage
  • Temperature & bend: -40 to +80 °C; min bend 4×OD fixed / 7.5×OD drag chain

PROFINET Type A / Type B / Type C Pair Twist, Foil & Braid Construction

Each PROFINET cable is built around precision-extruded polyolefin cores and a dual SF/UTP or S/FTP shield to preserve 100 Ω balance and FastConnect stripping concentricity.

  • Conductor: Type A: solid bare copper (22/1 AWG, 1×0.64 mm). Type B: 7-strand tinned/bare copper (22/7 AWG, 7×0.25 mm or 23/7 AWG). Type C / Type R: 7-strand (7×0.25 mm), 19-strand (19×0.15 mm) or 26/7 AWG tinned copper.
  • Insulation: Solid or cellular (Foam-Skin) polyethylene/polyolefin (PE/PO) for low dielectric loss and stable 100 Ω impedance.
  • Stranding & Color Code: Cat5e Star-Quad: 4 cores (White, Yellow, Blue, Orange) twisted around a central filler into a symmetrical star-quad. Cat6A: 4 twisted pairs (WH/BU, WH/OG, WH/GN, WH/BN).
  • Inner Bedding Sheath (Cat5e FC): Halogen-free thermoplastic or PVC inner bedding sheath extruded over the star-quad to lock core geometry and guarantee 6.5 mm FastConnect stripping.
  • Pair / Overall Foil Screen: Cat5e SF/UTP: 100% overlapping aluminum-laminated polyester tape over the inner sheath. Cat6A S/FTP: individual aluminum/PET foil shield on every pair (PiMF).
  • Overall Braided Shield: High-coverage (≥85%) tinned copper wire braid over the foil screen for low-frequency magnetic and high-frequency RF shielding.
  • Outer Sheath: PVC, FRNC/LSZH or oil/hydrolysis-resistant polyether PUR in green (RAL 6018) or outdoor black, with sequential meter marking.

Signal Integrity, Crosstalk & Noise Rejection

  • FastConnect (FC) 6.5 mm Star-Quad geometry: Cat5e Type A, Type B and Type C maintain a standardized 6.5 mm ± 0.2 mm outer diameter and inner bedding sheath for rapid one-step RJ45 and M12 D-coded FastConnect termination.
  • SF/UTP & S/FTP >85% double EMC shielding: Combines 100% overlapping aluminum-laminated polyester tape with a high-density ≥85% tinned copper braid (transfer impedance ≤20 mΩ/m at 10 MHz) for immunity near VFD servo drives.
  • Type C drag-chain & Type R robot torsion: Type C PUR cables withstand 5 million+ drag-chain cycles at 7.5×OD, 5 m/s speed and 10 m/s² acceleration; Type R variants withstand ±180°/m torsion on 6-axis welding and assembly robots.
  • PVC, LSZH & PUR jackets (300V / 600V): Available with flame-retardant PVC (IEC 60332-1-2), halogen-free FRNC/LSZH (IEC 60754 / IEC 61034) or oil/coolant-resistant polyether PUR sheaths rated 300 V or 600 V for power-and-data tray routing.

Process Plant, Moisture, UV & Chemical Protection

  • Low loop resistance (≤115 Ω/km on 22 AWG): Full 22 AWG (0.34–0.36 mm²) conductors minimize DC voltage drop for Power over Ethernet (PoE / PoE+ IEEE 802.3af/at) industrial switches and M12 field modules.
  • PNO color code (White/Yellow/Blue/Orange): Star-Quad Cat5e cores follow the mandatory PROFINET quad sequence (Pair 1: Yellow/Orange; Pair 2: White/Blue) for error-free IDC termination in RJ45 and M12 D-coded connectors.
  • Oil, coolant & hydrolysis resistance: Type B and Type C PUR sheaths resist mineral oils (EN 60811-404), cutting emulsions, hydrolysis and microbial attack in wet machine-tool and food-beverage washdown zones.
  • Cat6A 500 MHz 10 Gbps S/FTP option: Individually foil-screened pairs (PiMF, White/Blue, White/Orange, White/Green, White/Brown) with overall tinned copper braid support PROFINET with TSN and 10 Gbps vision backbones.

EN 50288 / PAS 5308 / Fieldbus Protocol Standards

  • PNO PROFINET Cabling and Interconnection Technology Guideline: Order No. 2.008
  • IEC 61156-5: horizontal floor wiring) & IEC 61156-6 (work area / drag-chain cables
  • ISO/IEC 11801 & EN 50173-1: Class D 100 MHz Cat5e & Class EA 500 MHz Cat6A
  • IEC 60332-1-2: flame retardance), IEC 60754-1/2 (LSZH/PUR halogen-free) & EN 60811-404 (oil resistance
  • Manufactured in accordance with UL 758 Style 21694 / 20233 / 20963: 300 V / 600 V 80 °C

Instrumentation & Industrial Bus Guides

Industrial Ethernet and PROFINET fieldbus cables terminated in an automation control cabinet
PROFINET Type A, Type B and Type C Cat5e Star-Quad and Cat6A S/FTP cables provide 100 Ω EMC-shielded Ethernet connectivity for PLCs, distributed I/O and motion-control drives. Photo: Wikimedia Commons contributor, CC0, via Wikimedia Commons.

PROFINET Type A / Type B / Type C Process Control & Telemetry Topology

Under the PROFIBUS & PROFINET International (PNO) Cabling Guideline (Order No. 2.008), industrial Ethernet cables are classified into mechanical installation types so system integrators can match conductor stranding and jacket chemistry to machine dynamics while maintaining strict 100 Ω ± 15 Ω characteristic impedance and 6.5 mm FastConnect (FC) stripping geometry. PROFINET Type A uses solid 1/0.64 mm (22/1 AWG) bare copper conductors for permanent cabinet-to-field links up to 100 m; PROFINET Type B uses 7-strand 7/0.25 mm (22/7 AWG) bare or tinned copper conductors for vibrating machinery and flexible cabinet harnessing; and PROFINET Type C uses 7-strand or 19-strand tinned copper conductors with low-friction inner bedding and an oil-resistant polyurethane (PUR) jacket for continuous drag-chain travel (up to 5 million–10 million cycles at 7.5 × OD) or Type R multi-axis robotic torsion (±180°/m).

For standard real-time (RT) and isochronous real-time (IRT) motion control at 100 Mbps, the Cat5e 2×2×22 AWG Star-Quad construction twists four polyolefin-insulated cores (White, Yellow, Blue, Orange) with a central filler so opposing diagonal pairs (White/Blue and Yellow/Orange) cancel external electromagnetic fields. An inner thermoplastic bedding sheath maintains circular FastConnect stripping tolerances beneath the SF/UTP double screen (100% aluminum/PET tape plus ≥85% optical-coverage tinned copper wire braid). For 1 Gbps and 10 Gbps high-speed machine vision and backbone networks, PROFINET Cat6A (4×2×22/1 AWG, 4×2×23/7 AWG or 4×2×26/7 AWG S/FTP) provides individual foil screening on each pair (PiMF) plus an overall tinned copper braid rated up to 500 MHz. Compare also with ourPROFIBUS DP & PA 150 Ω fieldbus cables,120 Ω RS-485 data bus cablesandS 368 C / S 369 C TP PUR drag-chain data cables.

DCS, PLC, Fieldbus & Sensor Network Routes

  • PROFINET Type A, Type B and Type C cables connect industrial PLCs, distributed I/O islands, servo drives, encoder gateways, HMI panels and gigabit machine-vision cameras across automotive body-in-white lines, CNC machining centers, automated storage and retrieval systems (AS/RS), packaging lines and process plants. The signature RAL 6018 green outer sheath immediately identifies real-time PROFINET channels inside control cabinets and overhead cable trays, while black UV-resistant PE or PUR jackets are supplied for outdoor and heavy-duty drag-chain installations.
  • When selecting between Cat5e Star-Quad and Cat6A 4-Pair, verify both data rate and channel length: 2×2×22 AWG Cat5e Star-Quad supports 100BASE-TX PROFINET RT/IRT over a full 100 m channel (90 m permanent link + 10 m patch cords) with minimal loop resistance (≤115 Ω/km) for PoE sensors, whereas 4×2×26/7 AWG Type C Cat6A supports 10GBASE-T up to 60–70 m in flexing drag chains (or 100 m with 4×2×22/1 AWG Type A / 4×2×23/7 AWG Type B). For composite servo power plus encoder feedback in drag chains, see ourSL 800 / SL 801 C composite PUR servo cables.

PROFINET Type A / Type B / Type C Impedance, Grounding & Bus FAQ

What is the difference between PROFINET Type A, Type B, Type C and Type R cables?

The PNO PROFINET Cabling Guideline defines four mechanical classes: Type A uses solid 22/1 AWG copper conductors for permanent, motionless installations; Type B uses 7-strand 22/7 AWG conductors for flexible routing and occasional movement; Type C uses extra-flexible 7-wire or 19-wire tinned copper conductors with a wear-resistant PUR jacket for continuous linear drag chains; and Type R is engineered for multi-axis torsional twisting (±180°/m) on industrial robots.

Why does Cat5e PROFINET use a 4-wire Star-Quad instead of 2 separate twisted pairs?

In a symmetrical Star-Quad (White, Yellow, Blue, Orange), the two signal pairs (Pair 1: Yellow/Orange; Pair 2: White/Blue) lie diagonally opposite each other around a common center axis. This geometry provides superior magnetic field cancellation, higher mechanical crush stability inside drag chains, and a perfectly circular core assembly that works with FastConnect (FC) stripping tools.

When should I specify Cat6A 4-pair PROFINET instead of Cat5e 2-pair Star-Quad?

Cat5e 2×2×22 AWG Star-Quad is the PNO standard for 100 Mbps PROFINET RT and IRT field devices (PLCs, I/O blocks, drives and valves). Specify Cat6A 4×2 S/FTP when the link requires 1 Gbps or 10 Gbps bandwidth (such as industrial PC backbones, PROFINET over TSN, high-resolution 3D machine-vision cameras, or 4-pair IEEE 802.3bt PoE++ power delivery).

Can PROFINET cables be routed in the same cable tray or drag chain as 400V/600V motor power cables?

Yes, provided you specify a 300 V or 600 V UL 758 AWM rated jacket (such as Style 21694 / 20233) for shared tray voltage compliance and maintain the PNO-recommended physical separation or metallic divider from unshielded VFD motor cables. The double SF/UTP or S/FTP shield (≥85% tinned copper braid + 100% Al/PET foil) prevents inverter switching noise from corrupting telegrams.

TEBAOFLEX engineering specifications and dimensional tables for PROFINET Type A, Type B, Type C and Type R (robotic torsion) Cat5e Star-Quad (2×2×22 AWG) and Cat6A S/FTP 4-pair (4×2×22–26 AWG) industrial Ethernet cables.

TEBAOFLEX® — PROFINET Type A / Type B / Type C Cat5e & Cat6A Industrial Ethernet Cable

PROFINET Cat5e (2×2×22 AWG Star-Quad SF/UTP) & Cat6A (4×2×22–26 AWG S/FTP) Dimensional & Construction Table
Part Code PROFINET Type & Category Pair × Gauge (Stranding) Conductor Material Insulation & Core Colors Screen Architecture Inner / Outer Sheath (Color) Nom. OD (mm) Min. Bend Radius (Fixed / Flex) Approx. Weight (kg/km)
PN-A-C5E-PVC Type A Cat5e (Fixed) 1×4×22/1 AWG (1×0.64 mm) Solid bare copper PE (WH, YE, BU, OG) SF/UTP (Al/PET + 85% CuSn) FRNC bedding / PVC (RAL 6018 Green) 6.5 4×OD / 8×OD (install) 62
PN-A-C5E-LSZH Type A Cat5e (Fixed LSZH) 1×4×22/1 AWG (1×0.64 mm) Solid bare copper PE (WH, YE, BU, OG) SF/UTP (Al/PET + 85% CuSn) FRNC bedding / LSZH (RAL 6018 Green) 6.5 4×OD / 8×OD (install) 64
PN-A-C5E-PUR Type A Cat5e (Fixed Heavy-Duty) 1×4×22/1 AWG (1×0.65 mm) Solid bare copper PE (WH, YE, BU, OG) SF/UTP (Al/PET + 85% CuSn) FRNC bedding / PUR (RAL 6018 Green) 6.5 4×OD / 8×OD (install) 61
PN-B-C5E-PVC Type B Cat5e (Flexible) 1×4×22/7 AWG (7×0.25 mm) Stranded tinned copper PE (WH, YE, BU, OG) SF/UTP (Al/PET + 85% CuSn) PVC bedding / PVC (RAL 6018 Green) 6.5 5×OD / 8×OD 65
PN-B-C5E-LSZH Type B Cat5e (Flexible LSZH) 1×4×22/7 AWG (7×0.25 mm) Stranded tinned copper PE (WH, YE, BU, OG) SF/UTP (Al/PET + 85% CuSn) FRNC bedding / LSZH (RAL 6018 Green) 6.5 5×OD / 8×OD 66
PN-B-C5E-PUR Type B Cat5e (Flexible PUR) 1×4×22/7 AWG (7×0.25 mm) Stranded tinned copper PE (WH, YE, BU, OG) SF/UTP (Al/PET + 85% CuSn) TPE bedding / PUR (RAL 6018 Green) 6.5 5×OD / 8×OD 63
PN-C-C5E-PUR Type C Cat5e (Drag Chain) 1×4×22/7 AWG (7×0.25 mm) Tinned copper (chain grade) Foam-Skin PO (WH, YE, BU, OG) SF/UTP (Al/PET + 85% CuSn) Halogen-free bedding / PUR (RAL 6018) 6.5 5×OD / 7.5×OD (chain) 63
PN-C19-C5E-PUR Type C Cat5e (Ultra-Flex Chain) 1×4×22/19 AWG (19×0.15 mm) Extra-fine tinned copper Polyolefin (WH, YE, BU, OG) SF/UTP (Al/PET + 85% CuSn) TPE bedding / PUR (RAL 6018 Green) 6.5 5×OD / 7.5×OD (chain) 62
PN-R-C5E-PUR Type R Cat5e (Robot Torsion ±180°/m) 1×4×22/19 AWG (19×0.15 mm) Extra-fine tinned copper Polyolefin (WH, YE, BU, OG) SF/UTP (PTFE wrap + 85% CuSn) TPE bedding / PUR (RAL 6018 / Black) 6.5 5×OD / 10×OD (±180°/m) 61
PN-A-C6A-LSZH Type A Cat6A (10G Fixed) 4×2×22/1 AWG (1×0.64 mm) Solid bare copper Foam-Skin PE (TIA/EIA 568B) S/FTP (PiMF + 85% CuSn braid) None / LSZH or PVC (RAL 6018 Green) 8.8 4×OD / 8×OD (install) 88
PN-B-C6A-PUR Type B Cat6A (10G Flexible) 4×2×23/7 AWG (7×0.23 mm) Stranded tinned copper Foam-Skin PE (TIA/EIA 568B) S/FTP (PiMF + 85% CuSn braid) None / PUR (RAL 6018 Green) 8.5 5×OD / 8×OD 82
PN-C-C6A-PUR Type C Cat6A (10G Drag Chain) 4×2×26/7 AWG (7×0.16 mm) Tinned copper (chain grade) Foam-Skin PO (TIA/EIA 568B) S/FTP (PiMF + 85% CuSn braid) Low-friction wrap / PUR (RAL 6018) 7.8 5×OD / 7.5×OD (chain) 72

TEBAOFLEX® — PROFINET Type A / Type B / Type C Cat5e & Cat6A Industrial Ethernet Cable

High-Frequency Transmission & Electrical Characteristics (20 °C per IEC 61156-5 / IEC 61156-6 & PNO Guideline)
Frequency (MHz) Cat5e Type A/B Max. Attenuation (dB/100m) Cat5e Type C Max. Attenuation (dB/100m) Cat5e Min. NEXT (dB) Cat6A Type A/B Max. Attenuation (dB/100m) Cat6A Type C (26 AWG) Max. Attenuation (dB/100m) Cat6A Min. NEXT (dB) Min. Return Loss (dB)
1 MHz 2.1 2.4 65.3 2.1 2.9 75.0 20.0
4 MHz 4.0 4.5 56.3 3.8 5.5 66.3 23.0
10 MHz 6.3 7.1 50.3 5.9 8.7 60.3 25.0
16 MHz 8.0 9.0 47.2 7.5 11.0 57.2 25.0
20 MHz 9.0 10.1 45.8 8.4 12.3 55.8 25.0
31.25 MHz 11.4 12.8 42.9 10.5 15.5 52.9 23.6
62.5 MHz 16.5 18.5 38.4 15.0 22.2 48.4 21.5
100 MHz 21.3 24.0 35.3 19.1 28.5 45.3 20.1
250 MHz — (Cat5e rated 100 MHz) — — 31.1 46.0 39.3 17.3
500 MHz — — — 45.3 66.5 34.8 15.6

TEBAOFLEX® — PROFINET Type A / Type B / Type C Cat5e & Cat6A Industrial Ethernet Cable

Low-Frequency Electrical & Mechanical Operating Parameters
Parameter Cat5e Type A (22/1 AWG) Cat5e Type B (22/7 AWG) Cat5e Type C / Type R (22/7 & 22/19 AWG) Cat6A Type A/B (22/1 & 23/7 AWG) Cat6A Type C (26/7 AWG)
Max. DC Loop Resistance at 20 °C ≤ 115 Ω/km ≤ 115 Ω/km ≤ 115 Ω/km (22/7) / ≤ 120 Ω/km (22/19) ≤ 115 Ω/km (22 AWG) / ≤ 145 Ω/km (23 AWG) ≤ 280 Ω/km
Characteristic Impedance 100 Ω ± 15 Ω (1–100 MHz) 100 Ω ± 15 Ω (1–100 MHz) 100 Ω ± 15 Ω (1–100 MHz) 100 Ω ± 15 Ω (1–500 MHz) 100 Ω ± 15 Ω (1–500 MHz)
Mutual Capacitance at 1 kHz approx. 48–50 nF/km approx. 48–50 nF/km approx. 48–50 nF/km approx. 43–46 nF/km approx. 45 nF/km
Velocity of Propagation (NVP) approx. 65%–68% approx. 65%–68% approx. 68%–75% approx. 76%–78% approx. 75%
Signal Propagation Delay ≤ 530 ns/100 m ≤ 530 ns/100 m ≤ 510 ns/100 m ≤ 450 ns/100 m ≤ 460 ns/100 m
Transfer Impedance (at 10 MHz) ≤ 10 mΩ/m (Grade 1/2) ≤ 10 mΩ/m (Grade 1/2) ≤ 20 mΩ/m ≤ 10 mΩ/m (Grade 1) ≤ 15 mΩ/m
Drag-Chain / Torsion Rating Fixed installation only Occasional flex (not for chain) ≥ 5 million cycles (Type C); ±180°/m (Type R) Fixed (Type A) / Occasional flex (Type B) ≥ 3–5 million cycles at 7.5×OD
Operating Temperature (Fixed / Flex) -40 to +80 °C / -20 to +70 °C -40 to +80 °C / -20 to +75 °C -40 to +80 °C / -30 to +70 °C -40 to +80 °C / -20 to +75 °C -40 to +80 °C / -30 to +70 °C

Selection guide: Specify Type A (solid 22/1 AWG) for fixed trunk wiring between cabinets, Type B (7-wire 22/7 AWG) for vibrating equipment and flexible cabinet routing, Type C (PUR 22/7 or 22/19 AWG) for linear drag chains, and Type R for 3D robotic torsion.

Ordering & Quotation Checklist: Request a factory quotation for PROFINET Type A, Type B, Type C or Type R Cat5e Star-Quad and Cat6A S/FTP cables — specify type class, jacket material (PVC, LSZH or PUR) and drum length.

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for PROFINET Type A / Type B / Type C Cat5e & Cat6A Industrial Ethernet Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.

  • ISO 9001 Factory Direct
  • MOQ 50 m (Custom Builds)
  • 24h Engineering Reply
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    PROFINET Type A / Type B / Type C Cat5e & Cat6A Industrial Ethernet CableGet A Quote