600V UL 1569 Type MC THHN/THWN Aluminum Interlocked Armor & Jacketed MC Cable
Engineered to UL 1569 and NEC Article 330 for commercial high-rise branch circuits, healthcare/data-center distribution, and industrial plant feeders, this 600 V Metal-Clad (Type MC) cable range encompasses Bare Lightweight Aluminum Interlocked Armor (AIA) Type MC Cables with THHN/THWN-2 Copper Conductors and Insulated Green Ground (14/2 to 2/4 AWG, in 120/208 V and 277/480 V phase color codes) as well as.
- Standard designationsUL 1569 (Metal-Clad Cables — Type MC), UL 83 (THHN/THWN-2), NEC Article 330, Federal Spec A-A-59544
- Armor constructionsBare Lightweight Aluminum Interlocked Armor (AIA) or PVC-Jacketed Aluminum/Galvanized Steel AIA
- Rated voltage & temp.600 V AC; 90 °C dry / 75 °C wet (THHN/THWN) or 90 °C wet/dry (THHN/THWN-2 & XHHW-2 feeder cores)
- Conductors & groundSolid or Class B stranded annealed copper (14 AWG–750 kcmil) + full-sized green insulated copper ground
- Core insulationHeat- and moisture-resistant PVC with extruded Polyamide (Nylon) sheath (UL 83 Type THHN/THWN-2)
- Phase color coding120/208V (Black, Red, Blue, White + Green) or 277/480V (Brown, Orange, Yellow, Gray + Green)
- Outer jacket (Jacketed MC)Sunlight-resistant, oil-resistant, direct-burial & concrete-encased Black PVC outer jacket
- Installation scopePlenum/environmental air spaces (Bare AIA MC per NEC 300.22(C), cable trays, direct burial & wet locations (Jacketed MC)
600V UL 1569 Type MC THHN/THWN Aluminum Core Identification & Ratings
- Type: Industrial Power Cable
- Standard designations: UL 1569 (Metal-Clad Cables — Type MC), UL 83 (THHN/THWN-2), NEC Article 330, Federal Spec A-A-59544
- Armor constructions: Bare Lightweight Aluminum Interlocked Armor (AIA) or PVC-Jacketed Aluminum/Galvanized Steel AIA
- Rated voltage & temp.: 600 V AC; 90 °C dry / 75 °C wet (THHN/THWN) or 90 °C wet/dry (THHN/THWN-2 & XHHW-2 feeder cores
Electrical, Thermal & Mechanical Bend Limits
- Conductors & ground: Solid or Class B stranded annealed copper (14 AWG–750 kcmil) + full-sized green insulated copper ground
- Core insulation: Heat- and moisture-resistant PVC with extruded Polyamide (Nylon) sheath (UL 83 Type THHN/THWN-2
- Phase color coding: 120/208V (Black, Red, Blue, White + Green) or 277/480V (Brown, Orange, Yellow, Gray + Green
- Outer jacket (Jacketed MC): Sunlight-resistant, oil-resistant, direct-burial & concrete-encased Black PVC outer jacket
- Installation scope: Plenum/environmental air spaces (Bare AIA MC per NEC 300.22(C), cable trays, direct burial & wet locations (Jacketed MC
600V UL 1569 Type MC THHN/THWN Aluminum Conductor, Insulation & Sheath Build
Combining UL 83 THHN/THWN-2 copper conductors, a full-sized insulated green copper ground, and precision aluminum interlocked armor with an optional direct-burial PVC outer sheath.
- Phase & Neutral Conductors: Solid (14–10 AWG) or Class B stranded (14 AWG–750 kcmil) soft annealed copper per ASTM B3 / B8.
- Core Insulation: 90 °C flame-retardant PVC with a tough extruded Polyamide (Nylon) outer jacket (UL 83 Type THHN/THWN-2).
- Equipment Ground: Full-sized green insulated copper grounding conductor sized per UL 1569 and NEC Table 250.122.
- Assembly & Armor: Moisture-resistant polypropylene binder tape + helically applied Lightweight Aluminum Interlocked Armor (AIA).
- Outer Jacket (Jacketed MC): Sunlight-, oil- and moisture-resistant Black PVC outer sheath rated for direct burial and concrete encasement.
Primary Electrical & Mechanical Performance
- Lightweight Aluminum Interlocked Armor (AIA): Precision helically interlocked aluminum strip armor eliminates EMT conduit bending and pulls smoothly through metal studs and ceiling plenums.
- 120/208V & 277/480V Color-Coded THHN/THWN: Factory color-coded phase, neutral, and green ground conductors prevent field phasing errors on 208Y/120V lighting and 480Y/277V power panels.
- Direct-Burial & Wet-Location PVC-Jacketed MC: Extruded UV-black PVC jacket over AIA armor qualifies Type MC for underground direct burial, concrete encasement, and outdoor rooftop trays.
- Full Branch-Circuit to 750 kcmil Feeder Range: Available from 14/2 AWG solid/stranded branch circuits up to 3C & 4C × 250–750 kcmil heavy industrial feeder cables.
Industrial Oil, Flame & Environmental Protection
- Reverse-lay & low-memory armor engineering: Cabled conductors and reverse-lay binder tape prevent corkscrewing and recoil during long horizontal tray pulls or vertical riser drops.
- Dedicated green insulated equipment ground: Every construction includes a full NEC Table 250.122 insulated green copper equipment grounding conductor inside the armor.
- RoHS, REACH & Federal Spec A-A-59544: Manufactured with lead-free PVC/Nylon compounds meeting UL 83, UL 1569, UL 1685 vertical tray flame, and U.S. Federal Specification A-A-59544.
- Matched with THHN/THWN-2 & XHHW-2 building wire: Pair with oursingle-core THHN/THWN-2 copper building wireandUL 44 XHHW-2 / CSA RW90 power wire.
IEC / EN / VDE / UL Reference Standards
- UL 1569: Standard for Metal-Clad Cables — Type MC
- UL 83: Thermoplastic-Insulated Wires and Cables — Type THHN / THWN-2
- NEC Article 330 (Metal-Clad Cable: Type MC), Art. 300.22(C) (Plenums) & Art. 518 (Assembly Occupancies
- UL 1685 / IEEE 1202: Vertical-Tray Flame-Propagation and Smoke-Release Test
- U.S. Federal Specification A-A-59544 & RoHS / REACH Directives
Industrial Cable Selection & Routing Guides

600V UL 1569 Type MC THHN/THWN Aluminum Industrial Installation & Routing Guide
Across North American commercial buildings, hospitals, semiconductor fabs, and automated warehouses, 600 V UL 1569 Type MC (Metal-Clad) Cable replaces labor-intensive EMT/rigid steel conduit and wire pulling with a factory-assembled, pre-tested armored wiring system that cuts installation time by up to 50%. Our Bare Lightweight Aluminum Interlocked Armor (AIA) Type MC Cable (14/2 to 2/4 AWG) combines solid (14–10 AWG) or Class B stranded (12–2 AWG) annealed copper THHN/THWN-2 phase and neutral conductors, a dedicated green-insulated copper equipment grounding conductor, a moisture-resistant polypropylene assembly binder tape, and a precision-formed 5000-series aluminum interlocked strip armor—weighing up to 45% less than steel armor while qualifying for environmental air plenums (NEC 300.22(C) and Places of Assembly (NEC 518.4).
When circuits transition outdoors, underground into direct-buried trenches, into concrete slabs, washdown food/beverage plants, or wastewater treatment galleries (NEC 330.10(A)(11), our 600 V PVC-Jacketed Type MC Interlocked Armor Cable (14 AWG to 750 kcmil) extrudes a continuous, sunlight-, oil-, and moisture-resistant Black PVC outer jacket over the aluminum interlocked armor. This dual-barrier design delivers full wet-location, direct-burial, and UL 1685 / IEEE 1202 vertical cable tray flame compliance. Compare with our600V/1000V CSA C22.2 No. 131 Teck90 XLPE interlocked armor cablesandUL 2225 Type MC-HL CCW welded aluminum hazardous-location cables.
Typical Plant, Machine & Infrastructure Circuits
- Bare Aluminum Interlocked Armor (AIA) Type MC Cables (14/2 to 2/4 AWG) wire commercial office lighting, retail power drops, data-center PDU whips, high-rise riser shafts, and above-ceiling environmental air-handling spaces.
- PVC-Jacketed Type MC Interlocked Armor Cables (14/2 AWG to 4C × 750 kcmil) serve outdoor chiller/rooftop HVAC feeders, parking garage decks, direct-buried site lighting, car-wash/food-processing wet areas, and industrial cable trays.
600V UL 1569 Type MC THHN/THWN Aluminum Specification & Selection FAQ
Can Bare Aluminum Interlocked Armor (AIA) Type MC cable be installed in ceiling environmental air plenums?
Yes. Under NEC 300.22(C)(1), bare metal-clad Type MC cable without a non-metallic outer jacket is explicitly permitted in other spaces used for environmental air (return-air ceiling plenums) because the aluminum armor encloses the insulated conductors without adding a combustible outer sheath.
When is PVC-Jacketed Type MC required instead of Bare AIA Type MC?
Per NEC 330.10(A)(11), PVC-Jacketed Type MC is required in wet locations, direct-buried underground trenches, concrete-encased slabs or cinder fill (where bare aluminum would corrode from alkaline concrete), outdoor rooftop cable trays exposed to sunlight, and corrosive washdown areas.
Does standard UL 1569 Type MC armor serve as the equipment grounding path on its own?
Standard interlocked strip armor requires the internal green insulated copper ground wire to serve as the NEC Article 250 equipment grounding conductor (unless it is a specializedMCI-A construction with a full-sized aluminum bond wire). All of our UL 1569 Type MC cables include a dedicated green insulated copper ground conductor.
What is the difference between 120/208 V and 277/480 V color codes in Type MC branch cables?
For 3-phase 208Y/120 V systems, the cores are colored Black (Phase A), Red (Phase B), Blue (Phase C), White (Neutral), and Green (Ground). For 3-phase 480Y/277 V commercial lighting and HVAC systems, the cores are colored Brown (Phase A), Orange (Phase B), Yellow (Phase C), Gray (Neutral), and Green (Ground).
Dimensional, conductor/ground gauge, armor diameter, PVC outer jacket wall, weight, and NEC 90 °C / 75 °C ampacity tables for 600 V UL 1569 Bare Aluminum Interlocked Armor Type MC and PVC-Jacketed Type MC cables.
TEBAOFLEX® — 600V UL 1569 Type MC THHN/THWN Aluminum Interlocked Armor & Jacketed MC Cable
| Size & Conductors (AWG) | Stranding (Copper) | Green Insulated Ground (AWG) | 120/208V or 277/480V Colors | Nominal Armor OD (in / mm) | Net Weight (lbs/kft / kg/km) | Ampacity 75 °C / 90 °C (A) |
|---|---|---|---|---|---|---|
| 14/2 Solid / Stranded | Solid or 19-str Cu | 14 AWG Green | Blk, Wht (or Brn, Gry) | 0.450 / 11.4 | 79 / 118 | 20 / 25 (15A OCPD) |
| 14/3 Solid / Stranded | Solid or 19-str Cu | 14 AWG Green | Blk, Red, Wht (or Brn, Org, Gry) | 0.480 / 12.2 | 97 / 144 | 20 / 25 (15A OCPD) |
| 12/2 Solid / Stranded | Solid or 19-str Cu | 12 AWG Green | Blk, Wht (or Brn, Gry) | 0.495 / 12.6 | 107 / 159 | 25 / 30 (20A OCPD) |
| 12/3 Solid / Stranded | Solid or 19-str Cu | 12 AWG Green | Blk, Red, Wht (or Brn, Org, Gry) | 0.530 / 13.5 | 134 / 199 | 25 / 30 (20A OCPD) |
| 12/4 Solid / Stranded | Solid or 19-str Cu | 12 AWG Green | Blk, Red, Blu, Wht (or Brn, Org, Yel, Gry) | 0.565 / 14.4 | 162 / 241 | 20 / 24 (80% Derated) |
| 10/2 Solid / Stranded | Solid or 19-str Cu | 10 AWG Green | Blk, Wht (or Brn, Gry) | 0.560 / 14.2 | 156 / 232 | 35 / 40 (30A OCPD) |
| 10/3 Solid / Stranded | Solid or 19-str Cu | 10 AWG Green | Blk, Red, Wht (or Brn, Org, Gry) | 0.600 / 15.2 | 198 / 295 | 35 / 40 (30A OCPD) |
| 8/3 Stranded | 19-str Cu | 10 AWG Green | Blk, Red, Wht | 0.725 / 18.4 | 284 / 423 | 50 / 55 |
| 6/3 Stranded | 19-str Cu | 8 AWG Green | Blk, Red, Wht | 0.840 / 21.3 | 426 / 634 | 65 / 75 |
| 4/3 Stranded | 19-str Cu | 8 AWG Green | Blk, Red, Wht | 0.975 / 24.8 | 610 / 908 | 85 / 95 |
| 2/3 Stranded | 19-str Cu | 6 AWG Green | Blk, Red, Wht | 1.115 / 28.3 | 915 / 1,362 | 115 / 130 |
TEBAOFLEX® — 600V UL 1569 Type MC THHN/THWN Aluminum Interlocked Armor & Jacketed MC Cable
| Size & Conductors | Ground Wire (AWG Cu) | Diameter Over AIA Armor (in / mm) | PVC Jacket Wall (mil / mm) | Overall OD Over Jacket (in / mm) | Net Weight (lbs/kft / kg/km) | Ampacity 75 °C Wet / 90 °C Dry (A) |
|---|---|---|---|---|---|---|
| 12/2 Stranded Jacketed MC | 12 AWG | 0.517 / 13.1 | 50 / 1.27 | 0.617 / 15.7 | 151 / 225 | 25 / 30 |
| 12/3 Stranded Jacketed MC | 12 AWG | 0.549 / 13.9 | 50 / 1.27 | 0.649 / 16.5 | 183 / 272 | 25 / 30 |
| 10/3 Stranded Jacketed MC | 10 AWG | 0.622 / 15.8 | 50 / 1.27 | 0.722 / 18.3 | 256 / 381 | 35 / 40 |
| 8/3 Stranded Jacketed MC | 10 AWG | 0.725 / 18.4 | 50 / 1.27 | 0.825 / 21.0 | 355 / 528 | 50 / 55 |
| 6/3 Stranded Jacketed MC | 8 AWG | 0.840 / 21.3 | 50 / 1.27 | 0.940 / 23.9 | 510 / 759 | 65 / 75 |
| 3C × 1/0 AWG Feeder MC | 6 AWG | 1.240 / 31.5 | 50 / 1.27 | 1.340 / 34.0 | 1,385 / 2,061 | 150 / 170 |
| 3C × 4/0 AWG Feeder MC | 4 AWG | 1.565 / 39.8 | 60 / 1.52 | 1.685 / 42.8 | 2,560 / 3,810 | 230 / 260 |
| 3C × 500 kcmil Feeder MC | 2 AWG | 2.215 / 56.3 | 75 / 1.91 | 2.365 / 60.1 | 5,620 / 8,363 | 380 / 430 |
Selection guide: Specify Bare Aluminum Interlocked Armor (AIA) Type MC for dry indoor/plenum branch circuits (120/208V or 277/480V colors), or PVC-Jacketed Type MC for wet locations, direct burial, concrete slabs, and outdoor cable trays.
Ordering & Quotation Checklist: Request a factory quotation for 600 V UL 1569 Bare Aluminum Interlocked Armor (AIA) Type MC or Direct-Burial PVC-Jacketed Type MC copper cables.
600V ICEA S-95-658 Power Cable & CSA C22.2 No. 131 Interlock Armored Cable
ICEA S-95-658 / NEMA WC 70, UL 1277, CSA C22.2 No. 131 (Type Teck / ACWU / Interlock)
600V/1000V Type MC-HL CCW Armored LSZH VFD & Type TC-ER-HL (-40 °C CPE) Cable
UL 2225 (Type MC-HL & Type TC-ER-HL), UL 1277 (Type TC-ER), UL 1569 (Type MC), CSA FT4
600V/1000V UL 44 XHHW-2 & CSA RW90 Single-Core XLPE Wire (Copper & AA-8000 Al)
UL 44 (Type XHHW-2), CSA C22.2 No. 38 (Type RW90), NEMA WC70 / ICEA S-95-658, NEC & CEC
Request Quotation & Datasheet for This Cable
Need factory pricing, cross-section drawing or a full PDF datasheet for 600V UL 1569 Type MC THHN/THWN Aluminum Interlocked Armor & Jacketed MC Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.
- ISO 9001 Factory Direct
- MOQ 50 m (Custom Builds)
- 24h Engineering Reply