UL 1063 MTW / CSA TEW Hook-Up & NEC CM/CMP Electronic Cable

Engineered for North American and global export industrial control cabinets, CNC machine tools (NFPA 79), appliance harnesses, and building automation backbones, our UL 1063 MTW / CSA TEW Multi-Rated Hook-Up Wire and NEC CM / CL3 / CMP Shielded Multi-Conductor & Multi-Pair Electronic Cables eliminate dual-inventory headaches across US, Canadian, and European compliance.

  • MTW / TEW Multi-RatingUL 1063 MTW (90 °C), CSA TEW (105 °C, 600V FT1), AWM 1015 / 1335 / 1336 (600V) & AWM 1032 (1000V)
  • Hook-Up Size Range18 AWG (16/30) to 8 AWG (133/29) standard; extended 24 AWG to 4/0 AWG
  • Electronic Cable RatingsNEC Type CM / CMG / CL2 / CL3 (UL 1685 / FT4) & Plenum CMP / CL2P / CL3P (NFPA 262)
  • Electronic ShieldingUnshielded, 100% Aluminum/Mylar Foil + Drain Wire, or Dual Foil + Tinned Cu Braid
  • Oil & Flame Resistance60 °C Oil-Resistant I, UL VW-1 Vertical Flame, CSA FT1 / FT4, NFPA 79 compliant
  • Stock Insulation ColorsBlack, White, Red, Blue, Green/Yellow, Orange, Yellow, Brown, Violet, Grey, Pink, Tan
  • Insulation & core designMoisture-, oil-, and flame-resistant Premium PVC (MTW/TEW/AWM) or Low-Smoke FEP / Plenum PVC (NEC CMP / CL3P)
  • Outer sheath & fire classSingle-core unjacketed (MTW/TEW) or Chrome Grey / Natural NEC CM, CL3, FT4 (FT1 / VW-1 / FT4 / NFPA 262 (UL 910 Plenum CMP)

UL 1063 MTW / CSA TEW Hook-Up & NEC High-Temperature Wire Identification

  • Type: PVC Control & Data Cable
  • MTW / TEW Multi-Rating: UL 1063 MTW (90 °C), CSA TEW (105 °C, 600V FT1), AWM 1015 / 1335 / 1336 (600V) & AWM 1032 (1000V
  • Hook-Up Size Range: 18 AWG (16/30) to 8 AWG (133/29) standard; extended 24 AWG to 4/0 AWG
  • Electronic Cable Ratings: NEC Type CM / CMG / CL2 / CL3 (UL 1685 / FT4) & Plenum CMP / CL2P / CL3P (NFPA 262

Continuous Thermal, Dielectric & AWG Ratings

  • Electronic Shielding: Unshielded, 100% Aluminum/Mylar Foil + Drain Wire, or Dual Foil + Tinned Cu Braid
  • Oil & Flame Resistance: 60 °C Oil-Resistant I, UL VW-1 Vertical Flame, CSA FT1 / FT4, NFPA 79 compliant
  • Stock Insulation Colors: Black, White, Red, Blue, Green/Yellow, Orange, Yellow, Brown, Violet, Grey, Pink, Tan
  • Insulation & core design: Moisture-, oil-, and flame-resistant Premium PVC (MTW/TEW/AWM) or Low-Smoke FEP / Plenum PVC (NEC CMP / CL3P
  • Outer sheath & fire class: Single-core unjacketed (MTW/TEW) or Chrome Grey / Natural NEC CM, CL3, FT4 (FT1 / VW-1 / FT4 / NFPA 262 (UL 910 Plenum CMP

UL 1063 MTW / CSA TEW Hook-Up & NEC Plated Conductor & Fluoropolymer/Silicone Build

Precision multi-layer construction engineered to meet UL 1063 (MTW) / UL 758 (AWM 1015, 1335, 1336, 1032) / CSA C22.2 No. 127 (TEW) / UL 444 (NEC CM, CL3, CMP) / NFPA 79 mechanical, thermal, and electrical/optical benchmarks.

  • Fine-Stranded Bare or Tinned Annealed Copper Conductors: MTW/TEW hook-up wire utilizes flexible bunched or rope-lay bare or tinned copper stranding (e.g., 16/30 in 18 AWG, 26/30 in 16 AWG, 41/30 in 14 AWG, 65/30 in 12 AWG, 105/30 in 10 AWG, 133/29 in 8 AWG) per ASTM B3/B33/B174 to resist vibration fatigue at DIN-rail terminal blocks.
  • Multi-Rated 105 °C Oil/Moisture-Resistant PVC & Plenum FEP Insulation: Hook-up wire features a nominal 0.76 mm (30 mil) wall of high-dielectric, lead-free PVC formulated to pass UL 1063 60 °C oil immersion, UL VW-1 flame, and CSA TEW 105 °C thermal aging. NEC CMP plenum electronic cables utilize low-dielectric-constant Fluorinated Ethylene Propylene (FEP) or low-smoke plenum PVC core insulation.
  • 100% Aluminum/Polyester Foil & Tinned Copper Braid Shielding (Electronic Cables): Shielded NEC CM and CMP electronic cables wrap the cabled conductors or individual/overall twisted pairs in a 100% coverage aluminum-mylar tape shield with a stranded tinned copper drain wire. High-noise industrial grades add a 65% to 85% coverage tinned copper braid shield for broadband RF and low-frequency magnetic interference rejection.
  • NEC CM / CL3 FT4 PVC or NFPA 262 Plenum CMP Outer Jacket: Multi-conductor and multi-pair electronic cables are finished with a smooth Chrome Grey or Natural PVC jacket rated NEC Type CM / CMG / CL2 / CL3 (UL 1685 / CSA FT4 vertical tray flame) or a low-smoke Plenum Type CMP / CL2P / CL3P jacket tested to NFPA 262 (UL 910 Steiner Tunnel).

Thermal Endurance, Outgassing & Dielectric Stability

  • MTW / TEW Multi-Rating: UL 1063 MTW (90 °C), CSA TEW (105 °C, 600V FT1), AWM 1015 / 1335 / 1336 (600V) & AWM 1032 (1000V
  • Hook-Up Size Range: 18 AWG (16/30) to 8 AWG (133/29) standard; extended 24 AWG to 4/0 AWG
  • Electronic Cable Ratings: NEC Type CM / CMG / CL2 / CL3 (UL 1685 / FT4) & Plenum CMP / CL2P / CL3P (NFPA 262
  • Electronic Shielding: Unshielded, 100% Aluminum/Mylar Foil + Drain Wire, or Dual Foil + Tinned Cu Braid

Chemical, Solvent, Flame & Cryogenic Resistance

  • Fine-Stranded Bare or Tinned Annealed Copper Conductors: MTW/TEW hook-up wire utilizes flexible bunched or rope-lay bare or tinned copper stranding (e.g., 16/30 in 18 AWG, 26/30 in 16 AWG, 41/30 in 14 AWG, 65/30 in 12 AWG, 105/30 in 10 AWG, 133/29 in 8 AWG) per ASTM B3/B33/B174 to resist vibration fatigue at DIN-rail terminal blocks.
  • Multi-Rated 105 °C Oil/Moisture-Resistant PVC & Plenum FEP Insulation: Hook-up wire features a nominal 0.76 mm (30 mil) wall of high-dielectric, lead-free PVC formulated to pass UL 1063 60 °C oil immersion, UL VW-1 flame, and CSA TEW 105 °C thermal aging. NEC CMP plenum electronic cables utilize low-dielectric-constant Fluorinated Ethylene Propylene (FEP) or low-smoke plenum PVC core insulation.
  • 100% Aluminum/Polyester Foil & Tinned Copper Braid Shielding (Electronic Cables): Shielded NEC CM and CMP electronic cables wrap the cabled conductors or individual/overall twisted pairs in a 100% coverage aluminum-mylar tape shield with a stranded tinned copper drain wire. High-noise industrial grades add a 65% to 85% coverage tinned copper braid shield for broadband RF and low-frequency magnetic interference rejection.
  • NEC CM / CL3 FT4 PVC or NFPA 262 Plenum CMP Outer Jacket: Multi-conductor and multi-pair electronic cables are finished with a smooth Chrome Grey or Natural PVC jacket rated NEC Type CM / CMG / CL2 / CL3 (UL 1685 / CSA FT4 vertical tray flame) or a low-smoke Plenum Type CMP / CL2P / CL3P jacket tested to NFPA 262 (UL 910 Steiner Tunnel).

UL 758 AWM / CSA / Aerospace & Furnace Standards

  • Machine Tool & Equipment Wire: UL 1063 (MTW) & CSA C22.2 No. 127 (TEW) — 600V continuous operation at 90 °C dry / 60 °C wet & oil (MTW) and 105 °C (CSA TEW
  • Appliance Wiring Material (AWM): UL 758 Styles 1015, 1032, 1335, 1336 — 600V 105 °C (1015/1335/1336) and 1000V 90 °C (Style 1032) dielectric & spark test
  • Riser & Tray Flame Propagation: UL 1685 / CSA FT4 / UL 1581 VW-1 — Char height ≤ 1.5 m in vertical tray flame test; self-extinguishing VW-1 / FT1
  • Plenum Smoke & Flame (CMP / CL3P): NFPA 262 (UL 910 Steiner Tunnel) — Max flame spread ≤ 1.52 m (5 ft); peak optical smoke density ≤ 0.50, average ≤ 0.15

High-Temperature & Fluoropolymer Wire Guides

Industrial installation of UL 1063 MTW / CSA TEW Hook-Up & NEC CM/CMP Electronic Cable (UL 1063 (MTW) / UL 758 (AWM 1015, 1335, 1336, 1032) / CSA C22.2 No. 127 (TEW) / UL 444 (NEC CM, CL3, CMP) / NFPA 79)
UL 1063 MTW / CSA TEW Hook-Up & NEC CM/CMP Electronic Cable engineered to UL 1063 (MTW) / UL 758 (AWM 1015, 1335, 1336, 1032) / CSA C22.2 No. 127 (TEW) / UL 444 (NEC CM, CL3, CMP) / NFPA 79 for high-reliability utility, industrial and infrastructure networks. Photo: Wikimedia Commons contributor, CC BY-SA 4.0, via Wikimedia Commons.

UL 1063 MTW / CSA TEW Hook-Up & NEC Thermal Zone & Internal Equipment Wiring

Engineered for North American and global export industrial control cabinets, CNC machine tools (NFPA 79), appliance harnesses, and building automation backbones, our UL 1063 MTW / CSA TEW Multi-Rated Hook-Up Wire and NEC CM / CL3 / CMP Shielded Multi-Conductor & Multi-Pair Electronic Cables eliminate dual-inventory headaches across US, Canadian, and European compliance regimes. The single-conductor hook-up wire series (18 AWG to 8 AWG and up to 4/0 AWG) carries simultaneous ratings for UL 1063 Machine Tool Wire (MTW 90 °C, 600V), UL 83 THW, CSA C22.2 No. 127 Equipment Wire (TEW 105 °C, 600V FT1), and UL 758 AWM Styles 1015, 1032 (1000V), 1335, and 1336 (plus 16–18 AWG TFF fixture wire). Complementing the panel wire range, our 300V and 600V NEC Type CM / CL2 / CL3 and Plenum Type CMP / CL2P / CL3P Electronic Cables (24 AWG to 12 AWG, 2 to 25 conductors or 1 to 19 twisted pairs) feature 100% aluminum-polyester foil shielding (+ 65%–85% tinned copper braid option) with a stranded tinned copper drain wire for RS-232, RS-422, RS-485, CAD/CAM, and PLC analog/digital signal transmission.

NFPA 79 Industrial Control Panels, PLC Racks & CNC Machine Tools: Multi-rated MTW / TEW / AWM 1015 hook-up wire is the benchmark internal wiring conductor for UL 508A industrial control panels, switchgear cubicles, motor starter buckets, and CNC machine tools operating in cutting-oil and coolant mist environments. Where European harmonized H05V-K / H07V-K is also specified on the same export BOM, compare ourtri-rated-bs6231-ul-csa-panel-wire.

Furnaces, Ovens, Avionics & Cleanroom Assemblies

  • RS-232 / RS-422 / RS-485 Serial Data, PLC I/O & Building Automation (NEC CM / CMP): Foil-shielded and foil-plus-braid-shielded multi-conductor and twisted-pair NEC CM / CL3 and Plenum CMP electronic cables interconnect BACnet/Modbus RTU controllers, variable air volume (VAV) boxes, card-access readers, industrial weighing scales, and instrumentation transmitters across commercial plenums and factory risers.
  • Appliance Harnesses, Power Supplies & Commercial HVAC Equipment: Dual AWM 1015 (600V 105 °C) and AWM 1032 (1000V 90 °C) ratings allow OEM harness fabricators to standardize on a single wire construction for internal wiring of transformers, UPS battery cabinets, commercial refrigeration units, and medical diagnostic equipment. For tray-rated multi-conductor field runs, see ourtc-er-xhhw2-urd-use2-nm-b-cable.

UL 1063 MTW / CSA TEW Hook-Up & NEC Thermal Rating & Stripping FAQ

What is the difference between UL 1063 MTW, UL 758 AWM 1015, and CSA TEW?

UL 1063 MTW (Machine Tool Wire) requires flexible stranding and 60 °C oil/coolant resistance for industrial machinery per NFPA 79 (rated 90 °C dry, 600V). UL 758 AWM Style 1015 is an Appliance Wiring Material rating (105 °C, 600V) for factory-assembled equipment, while CSA TEW (105 °C, 600V FT1) is the Canadian Standards Association equipment wire specification. Our multi-rated hook-up wire carries all three approvals on the same jacket print.

Why are 18 AWG and 16 AWG MTW hook-up wires also rated TFF, while 14 AWG to 8 AWG are rated THW?

Under the National Electrical Code (NEC) and UL standards, TFF (Thermoplastic Flexible Fixture Wire) applies specifically to 18 AWG and 16 AWG flexible stranded conductors for luminaire and control fixture drops, whereas UL 83 THW (Thermoplastic Heat and Water-Resistant building wire) starts at 14 AWG and larger.

Can NEC CMP plenum-rated electronic cables substitute for CM, CL2, and CL3 cables?

Yes. Under NEC Article 725 and Article 800 cable substitution hierarchies, Type CMP (Communications Plenum) and CL3P sit at the top of the fire-resistance pyramid and may be used unconditionally as a direct substitute for CMR, CMG, CM, CL3R, CL3, and CL2 cables in risers and general-purpose runs.

What drum lengths and factory test reports are supplied with UL 1063 MTW / CSA TEW Hook-Up & NEC CM/CMP Electronic Cable?

Standard production is supplied on export fumigated wooden drums (500 m, 1,000 m, or custom project cut lengths up to 4,000–6,000 m) accompanied by routine factory test certificates covering conductor resistance, dielectric/spark or OTDR optical attenuation, and dimensional verification to UL 1063 (MTW) / UL 758 (AWM 1015, 1335, 1336, 1032) / CSA C22.2 No. 127 (TEW) / UL 444 (NEC CM, CL3, CMP) / NFPA 79.

Comprehensive variant matrix and dimensional/electrical/optical specification tables for UL 1063 MTW / CSA TEW Hook-Up & NEC CM/CMP Electronic Cable (UL 1063 (MTW) / UL 758 (AWM 1015, 1335, 1336, 1032) / CSA C22.2 No. 127 (TEW) / UL 444 (NEC CM, CL3, CMP) / NFPA 79).

TEBAOFLEX® — UL 1063 MTW / CSA TEW Hook-Up & NEC CM/CMP Electronic Cable

UL 1063 MTW / CSA TEW Hook-Up & NEC CM/CMP Electronic Cable — Product Family Variants & Construction Matrix
Model / Series Construction & Shielding Core / Size Range Reference Standard Primary Application
600V / 1000V Multi-Rated UL 1063 MTW / CSA TEW / AWM 1015-1032 Hook-Up Wire Flexible Stranded Bare or Tinned Cu + 0.76 mm (30 mil) Oil/Flame-Resistant 105 °C PVC Insulation 1 × 18 AWG (0.82 mm²) to 1 × 8 AWG (8.37 mm²); extended up to 4/0 AWG UL 1063 MTW, CSA TEW 105 °C, UL 758 AWM 1015/1032/1335/1336, UL 83 THW, TFF (16-18 AWG) UL 508A / NFPA 79 control panels, machine tools, appliance harnesses & switchgear
300V / 600V NEC CM / CL3 Foil-Shielded Multi-Conductor Electronic Cable Stranded Tinned Cu (24–12 AWG) + Color-Coded PVC + 100% Al/PET Foil + Tinned Cu Drain Wire + Chrome Grey CM/FT4 PVC Jacket 2, 3, 4, 6, 8, 9, 12, 15, 19, 25 Conductors × 24, 22, 20, 18, 16, 14, 12 AWG UL 444 NEC Type CM / CMG, UL 13 CL2 / CL3, CSA C22.2 No. 214 CMG FT4, UL 2464 PLC digital/analog I/O, intercoms, RS-232 serial control, security & industrial sensors
300V NEC CM & Plenum CMP Overall / Individually Shielded Multi-Pair Cable Stranded Tinned Cu Twisted Pairs (24–16 AWG) + Semi-Rigid PVC or FEP + Overall Foil (or Foil+Braid) + CM PVC or CMP Plenum Jacket 1, 2, 3, 4, 6, 9, 12, 15, 19 Pairs × 24, 22, 20, 18 AWG NEC Type CM / CL2 / FT4 & NEC Type CMP / CL2P / CL3P (NFPA 262 / UL 910 Plenum) RS-422 / RS-485 Modbus networks, BACnet HVAC plenums, CAD/CAM & balanced audio/data

TEBAOFLEX® — UL 1063 MTW / CSA TEW Hook-Up & NEC CM/CMP Electronic Cable

Technical Specifications — UL 1063 MTW / CSA TEW Hook-Up Wire & NEC CM / CMP Shielded Electronic Cables
Product Series AWG / Pair Config Stranding (No. × AWG) Insulation Thickness (mm) Nominal OD (mm) Voltage & Temp Rating Max DC Resistance at 20 °C (Ω/km) Approx. Weight (kg/km)
MTW / TEW / AWM 1015 18 AWG (0.82 mm²) + TFF 16 × 30 AWG 0.76 (30 mil) 2.72 600V (1000V AWM 1032) / 105 °C 21.4 13.8
MTW / TEW / AWM 1015 16 AWG (1.31 mm²) + TFF 26 × 30 AWG 0.76 (30 mil) 3.05 600V (1000V AWM 1032) / 105 °C 13.5 19.8
MTW / TEW / AWM 1015 14 AWG (2.08 mm²) + THW 41 × 30 AWG 0.76 (30 mil) 3.45 600V (1000V AWM 1032) / 105 °C 8.50 28.3
MTW / TEW / AWM 1015 12 AWG (3.31 mm²) + THW 65 × 30 AWG 0.76 (30 mil) 3.94 600V (1000V AWM 1032) / 105 °C 5.35 41.4
MTW / TEW / AWM 1015 10 AWG (5.26 mm²) + THW 105 × 30 AWG 0.76 (30 mil) 4.57 600V (1000V AWM 1032) / 105 °C 3.35 63.7
MTW / TEW / AWM 1336 8 AWG (8.37 mm²) + THW 133 × 29 AWG 1.14 (45 mil) 6.60 600V (1000V AWM 1032) / 105 °C 2.10 114.6
NEC CM Multi-Conductor (Foil) 4C × 22 AWG Shielded 7 × 30 Tinned Cu 0.25 4.32 300V / 80 °C (CM / CL2 / FT4) 54.8 28.0
NEC CM Multi-Conductor (Foil) 6C × 18 AWG Shielded 16 × 30 Tinned Cu 0.41 6.86 300V / 80 °C (CM / CL3 / FT4) 21.8 73.0
NEC CM Multi-Conductor (Foil) 12C × 18 AWG Shielded 16 × 30 Tinned Cu 0.41 9.14 300V / 80 °C (CM / CL3 / FT4) 21.8 134.0
NEC CM Multi-Pair (Foil) 2 Pair × 22 AWG Shielded 7 × 30 Tinned Cu 0.25 5.33 300V / 80 °C (CM / CL2 / FT4) 54.8 33.0
NEC CM Multi-Pair (Foil+Braid) 2 Pair × 24 AWG RS-485 7 × 32 Tinned Cu 0.58 (Foam PE) 7.20 300V / 80 °C (120 Ω Nominal) 78.7 58.0
NEC CMP Plenum Multi-Conductor 4C × 18 AWG Shielded 7 × 26 Tinned Cu 0.23 (FEP) 4.75 300V / 150 °C Core (NFPA 262 CMP) 21.8 40.0
NEC CMP Plenum Multi-Pair 2 Pair × 18 AWG Shielded 7 × 26 Tinned Cu 0.23 (FEP) 5.84 300V / 150 °C Core (NFPA 262 CMP) 21.8 46.0

Selection guide: Standardize Cabinet Inventory with Multi-Rated MTW / TEW / AWM 1015: Instead of stocking separate UL 1063 MTW wire for US NFPA 79 machine panels, CSA TEW wire for Canadian assemblies, and UL AWM 1015/1032 wire for OEM appliances, specify our multi-rated 30-mil PVC hook-up wire (18 AWG to 10 AWG) to satisfy all four standards simultaneously. Choose NEC CM vs. NEC CMP Plenum for Building Data Runs: Specify standard PVC-jacketed NEC Type CM / CL3 (FT4) shielded electronic cables inside control panels, conduit, and general vertical shafts. Whenever the cable runs exposed through return-air ceiling plenums or raised environmental air floors without conduit, NEC Article 725/800 mandates Type CMP / CL2P / CL3P plenum-rated cable. Foil Shield vs. Foil + Braid Shield: A 100% aluminum/polyester foil shield with tinned copper drain wire provides complete high-frequency electrostatic screening for audio, intercoms, and short PLC analog loops. For RS-485 networks or variable-frequency drive (VFD) environments with heavy low-frequency switching noise, upgrade to a dual 100% Foil + 65%–85% Tinned Copper Braid shield.

Ordering & Quotation Checklist: Request a factory quotation and technical datasheet for UL 1063 MTW / CSA TEW Hook-Up & NEC CM/CMP Electronic Cable (UL 1063 (MTW) / UL 758 (AWM 1015, 1335, 1336, 1032) / CSA C22.2 No. 127 (TEW) / UL 444 (NEC CM, CL3, CMP) / NFPA 79).

600V/1000V Type TC-ER XHHW-2 Tray, 600V Aluminum URD (USE-2) & Type NM-B Cable

600V/1000V Type TC-ER XHHW-2 Tray, 600V Aluminum URD (USE-2) & Type NM-B Cable

Type TC-ER XHHW-2 (600V/1000V), 600V Aluminum URD (USE-2) & Type NM-B (600V)

VIEW PRODUCT »

12–52 kV Subsea DEH, 5 kV Skin-Effect (SECT), Alloy 825 MI Heating & Leak Cable

12–52 kV Subsea DEH, 5 kV Skin-Effect (SECT), Alloy 825 MI Heating & Leak Cable

12–52 kV Subsea Direct Electrical Heating (DEH), 5 kV Skin-Effect (SECT), 600 V Alloy 825 MI, FG-OD Hydrocarbon Leak Cable

VIEW PRODUCT »

21X-LS0H 125°C Switchboard Wire & N3GTMC11Y Screened EPR/PUR Control Cable

21X-LS0H 125°C Switchboard Wire & N3GTMC11Y Screened EPR/PUR Control Cable

21X-LS0H (125°C Single-Core Panel Wire) & N3GTMC11Y (0.6/1 kV Screened Multicore)

VIEW PRODUCT »

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for UL 1063 MTW / CSA TEW Hook-Up & NEC CM/CMP Electronic Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.

  • ISO 9001 Factory Direct
  • MOQ 50 m (Custom Builds)
  • 24h Engineering Reply
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    UL 1063 MTW / CSA TEW Hook-Up & NEC CM/CMP Electronic CableGet A Quote