2GAX / 4GAX / 6GAX / 8GAX / DLRB-3TP6C Buoyant ROV Tether & DataLine Cable
The 2GAX / 4GAX / 6GAX / 8GAX water-blocked subsea instrumentation cable family and the DLRB-3TP6C / DATALINE ROV neutrally buoyant ROV tether series cover two critical domains of underwater engineering: pressure-balanced wet-mateable connector pigtails and.
- Series Covered2GAX160 / 4GAX161 / 6GAX162 / 8GAX163 / 4GAX181 | DLRB-3TP6C | DATALINE ROV
- Rated Voltage600 V (GAX Series & DLRB-3TP6C Power) | 300 V (DATALINE ROV & Twisted Pairs)
- GAX Core Sizes2, 4, 6, or 8 Cores × 16 AWG (1.32 mm²) or 4 Cores × 18 AWG (0.836 mm²) Water-Blocked
- DLRB-3TP6C Layout6 × 1.0 mm² Power (600 V) + 3 × 2 × 0.2 mm² Shielded Twisted Pairs + Kevlar + Yellow Foamed PUR
- DATALINE ROV Layout4 × 2 × 22 AWG (0.35 mm²) Twisted Pairs + Aramid Braid + Black PUR + Yellow Foamed PUR
- Buoyancy / BlockingGAX: Full Interstitial Water-Blocking Compound | DLRB & DATALINE: Neutrally Buoyant Foamed PUR
- Breaking Load600 kg (DLRB-3TP6C Kevlar Braid) | 200 kgf Working Load (DATALINE ROV)
- Supply FormatCustom Cut Lengths, Export Wooden Drums, and OEM Harnessing
2GAX160 / 4GAX161 / 6GAX162 / 8GAX163 / Submersible & Hydrostatic Profile
- Type: Subsea & ROV Umbilical Cables
- Series Covered: 2GAX160 / 4GAX161 / 6GAX162 / 8GAX163 / 4GAX181 | DLRB-3TP6C | DATALINE ROV
- Rated Voltage: 600 V (GAX Series & DLRB-3TP6C Power) | 300 V (DATALINE ROV & Twisted Pairs
- GAX Core Sizes: 2, 4, 6, or 8 Cores × 16 AWG (1.32 mm²) or 4 Cores × 18 AWG (0.836 mm²) Water-Blocked
Immersion Depth, Pressure & Thermal Ratings
- DLRB-3TP6C Layout: 6 × 1.0 mm² Power (600 V) + 3 × 2 × 0.2 mm² Shielded Twisted Pairs + Kevlar + Yellow Foamed PUR
- DATALINE ROV Layout: 4 × 2 × 22 AWG (0.35 mm²) Twisted Pairs + Aramid Braid + Black PUR + Yellow Foamed PUR
- Buoyancy / Blocking: GAX: Full Interstitial Water-Blocking Compound | DLRB & DATALINE: Neutrally Buoyant Foamed PUR
- Breaking Load: 600 kg (DLRB-3TP6C Kevlar Braid) | 200 kgf Working Load (DATALINE ROV
- Supply Format: Custom Cut Lengths, Export Wooden Drums, and OEM Harnessing
2GAX160 / 4GAX161 / 6GAX162 / 8GAX163 / Water-Blocked Core & Sheath Architecture
Whether you require a water-blocked rubber whip for subsea sensor connectors or a floating yellow ROV excursion tether, each construction is engineered for hydrostatic integrity.
- Conductors: Stranded bare copper (26/0.254 mm 16 AWG or 16/0.254 mm 18 AWG on GAX) or fine-stranded tinned copper (DLRB-3TP6C and DATALINE ROV).
- Insulation: 600 V EPD rubber (GAX Series), thermoplastic elastomer TPE (DLRB-3TP6C), or HDPE (DATALINE ROV).
- Water-Blocking / Pair Shielding: Interstitial water-blocking compound on GAX Series; individual aluminum-mylar + 85% tinned copper braid shield on DLRB-3TP6C signal pairs.
- Inner Sheath & Kevlar Braid (ROV Series): Extruded inner TPE/PUR pressure jacket reinforced with a high-strength Aramid (Kevlar) fiber braid.
- Outer Jacket: Heavy-duty black Chloroprene Rubber (CR) on 2GAX–8GAX; high-visibility yellow closed-cell Foamed Polyurethane (PUR) on DLRB-3TP6C and DATALINE ROV.
Hydrostatic Integrity & Tensile Load Performance
- GAX Configurations: 2C, 4C, 6C, 8C × 16 AWG & 4C × 18 AWG
- Buoyant ROV Tethers: DLRB-3TP6C & DATALINE ROV (Foamed PUR
- Voltage Rating: 600 V (GAX / DLRB Power) / 300 V (Data
- Water Protection: Water-Blocked (GAX) / Neutrally Buoyant
Potable Water, Seawater, Slurry & Chlorine Resistance
- Overmold-Ready Chloroprene (CR) Jacket on GAX Series:: 2GAX160 through 8GAX163 use a vulcanized chloroprene rubber outer jacket specifically formulated for hot-vulcanized neoprene and polyurethane connector overmolding.
- Verified Axial Water-Blocking (< 5 cc @ 25 psig):: All interstices in the GAX series are filled with a non-hardening water-blocking compound that stops axial seawater migration under hydrostatic pressure.
- Neutrally / Positively Buoyant Foamed PUR (DLRB & DATALINE):: DLRB-3TP6C weighs 123 kg/km in air and -13 kg/km (slightly buoyant) in water, while DATALINE ROV achieves 0.99 ± 0.03 g/cm³ specific gravity.
- High-Tensile Kevlar Braid Reinforcement:: 600 kg breaking load on DLRB-3TP6C and 200 kgf safe working load on DATALINE ROV enable rapid tether recovery against subsea currents.
AD8 / KTW / ACS / Subsea Immersion Standards
- Subsea Connector Overmolding Standard: Outer chloroprene (CR) dimensions matched to standard 2-pin to 8-pin wet-mateable connector boots.
- Hydrostatic Axial Water-Blocking Test: < 5 cc water penetration after 2 hours at 25 psig differential pressure (GAX Series).
- IEC 60228 / ASTM B3 / B33: Flexible stranded bare and tinned copper subsea conductors.
- Neutral Buoyancy ROV Tether Design: Closed-cell syntactic/foamed PUR outer jacket achieving ~0.99 g/cm³ specific gravity.
Submersible Pump & Subsea Cable Guides

2GAX160 / 4GAX161 / 6GAX162 / 8GAX163 / Deep-Well, Dewatering & Subsea Deployment
The 2GAX / 4GAX / 6GAX / 8GAX water-blocked subsea instrumentation cable family and the DLRB-3TP6C / DATALINE ROV neutrally buoyant ROV tether series cover two critical domains of underwater engineering: pressure-balanced wet-mateable connector pigtails and zero-weight free-swimming ROV excursion tethers.
Engineered for direct molding to industry-standard subsea rubber bulkheads and inline wet-mateable connectors, 2GAX160 (2×16 AWG), 4GAX161 (4×16 AWG), 6GAX162 (6×16 AWG), 8GAX163 (8×16 AWG), and 4GAX181 (4×18 AWG) feature stranded bare copper conductors, 600 V ethylene propylene diene (EPD) rubber insulation, non-hygroscopic fillers, interstitial water-blocking compound (limiting water flow to < 5 cc in 2 hours at 25 psig), and a heavy-duty chloroprene (CR / Neoprene) outer jacket that bonds chemically to neoprene overmolds. For free-flying observation ROVs, hull-inspection crawlers, and diverless telemetry links where tether sinkage would snag on seabed structures, DLRB-3TP6C (13.3 mm OD, 6×1.0 mm² power + 3×2×0.2 mm² shielded twisted pairs) and DATALINE ROV (11.6 mm OD, 4×2×22 AWG twisted pairs) combine an Aramid (Kevlar) strength braid with a dual-layer polyurethane/cellular foamed-PUR jacket to achieve near-zero weight in water (-13 kg/km positively buoyant on DLRB-3TP6C). For heavy coaxial ROV video tethers, see ourPCX50 / PCX75 / P-HFCX Subsea Coaxial ROV CableandDUR06-ND / CDUR-01 Subsea Diver & ROV Umbilical.
Submersible Pumps, ROVs & Wet-Well Systems
- Subsea CTD rosettes, Doppler velocity logs (DVL), sonar heads, LED lighting bars, and hydraulic valve packs rely on 2-pin to 8-pin wet-mateable rubber connectors. If a standard unblocked cable is nicked at 1,000 meters depth, hydrostatic pressure forces seawater along the conductor interstices into the instrument housing. The water-blocked GAX series prevents axial hosing while matching the exact outer diameters required by standard subsea connector boot molds.
- Conversely, mini-ROVs and pipeline inspection vehicles require a tether that floats neutrally in the water column. DLRB-3TP6C and DATALINE ROV use a closed-cell foamed yellow polyurethane outer jacket over a tough inner PUR pressure barrier and Kevlar braid, allowing small thrusters to pull 150 m to 300 m of tether without drag.
2GAX160 / 4GAX161 / 6GAX162 / 8GAX163 / Immersion Depth & Sealing FAQ
Why are 2GAX160, 4GAX161, 6GAX162, and 8GAX163 the standard choice for subsea wet-mateable connectors?
Wet-mateable rubber connectors rely on vulcanized neoprene molding to create a high-pressure water seal. The GAX series uses an EPD rubber core insulation, internal water-blocking compound, and a Chloroprene (Neoprene) outer sheath whose exact outer diameters (9.65 mm to 15.80 mm) fit standard subsea connector molds and vulcanize seamlessly.
How do DLRB-3TP6C and DATALINE ROV achieve neutral buoyancy in water?
Copper and Kevlar are denser than water. To offset their weight without making the cable overly thick, DLRB-3TP6C and DATALINE ROV extrude a closed-cell foamed polyurethane (PUR) outer flotation jacket over an inner water-tight sheath, bringing overall specific gravity to 0.95–0.99 g/cm3.
What is the difference between DLRB-3TP6C and DATALINE ROV?
DLRB-3TP6C is a hybrid power-plus-data ROV tether containing six 1.0 mm2 (600 V) power cores and three individually shielded 0.2 mm2 twisted pairs (600 kg breaking load). DATALINE ROV is a dedicated 4-pair 22 AWG (0.35 mm2) communication and RS-485/Ethernet telemetry tether (11.6 mm OD).
Can GAX cables be ordered in long continuous reel lengths for subsea arrays?
Yes. We supply 2GAX160, 4GAX161, 6GAX162, 8GAX163, and 4GAX181 in both custom cut lengths for connector pigtail molding and continuous production drums up to 500 m / 1,000 m.
Complete dimensional, electrical, and buoyancy data below are compiled from TEBAOFLEX datasheets #60–#64 (GAX Series), #8 (DLRB-3TP6C), and #125 (DATALINE ROV).
TEBAOFLEX® — 2GAX / 4GAX / 6GAX / 8GAX 600V Water-Blocked Subsea Connector Cables (Datasheets #60–#64)
| Model Designation | Cores × Gauge (mm²) | Conductor Stranding | Insulation & Outer Jacket | Core Color Code | Nominal Outer Dia. (mm) | Water Flow @ 25 psig (2 hr) |
|---|---|---|---|---|---|---|
| 2GAX160 (#60) | 2 × 16 AWG (1.32 mm²) | 26 × 0.254 mm Bare Cu | 0.95 mm EPD / 1.85 mm Black CR | Black, White | 9.65 mm | < 5 cc |
| 4GAX161 (#61) | 4 × 16 AWG (1.32 mm²) | 26 × 0.254 mm Bare Cu | 0.95 mm EPD / 1.85 mm Black CR | Black, White, Red, Green | 11.50 mm | < 5 cc |
| 6GAX162 (#62) | 6 × 16 AWG (1.32 mm²) | 26 × 0.254 mm Bare Cu | 0.95 mm EPD / 2.25 mm Black CR | Black, White, Red, Green, Orange, Blue | 14.40 mm | < 5 cc |
| 8GAX163 (#63) | 8 × 16 AWG (1.32 mm²) | 26 × 0.254 mm Bare Cu | 0.95 mm EPD / 2.30 mm Black CR | Black, White, Red, Green, Orange, Blue, White/Black, Red/Black | 15.80 mm | < 5 cc |
| 4GAX181 (#64) | 4 × 18 AWG (0.836 mm²) | 16 × 0.254 mm Bare Cu | 0.95 mm EPD / 1.50 mm Black CR | Black, White, Red, Green | 9.90 mm | < 5 cc |
TEBAOFLEX® — DLRB-3TP6C & DATALINE ROV Neutrally Buoyant Subsea ROV Tethers (Datasheets #8 & #125)
| Model Designation | Core & Pair Configuration | Strength Member & Rating | Dual Jacket System | Nominal Outer Dia. (mm) | Weight in Air / Water | Min. Bending Radius |
|---|---|---|---|---|---|---|
| DLRB-3TP6C (#8) | 6 × 1.0 mm² Power (600 V) + 3 × 2 × 0.2 mm² Shielded Pairs (300 V) | Kevlar Braid (600 kg Breaking Load) | Inner TPE + Outer Yellow Foamed PUR | 13.3 ± 0.6 mm | 123 kg/km Air / -13 kg/km Water | 10 × D Fixed / 20 × D Flex |
| DATALINE ROV (#125) | 4 × 2 × 22 AWG (0.35 mm²) Twisted Pairs (19/0.15 mm TC) | Aramid Yarn Braid (200 kgf Working Load) | Inner Black PUR (7.3 mm) + Outer Yellow Foamed PUR | 11.6 ± 0.5 mm | Specific Gravity: 0.99 ± 0.03 g/cm³ | 10 × D (116 mm) |
Selection guide: Max conductor DC resistance at 20°C is 14.3 Ω/km for 16 AWG GAX, 23.1 Ω/km for 18 AWG GAX, 20.0 Ω/km for 1.0 mm² DLRB power cores, and 53.0 Ω/km for 22 AWG DATALINE ROV pairs.
Ordering & Quotation Checklist: Specify your required GAX core count (2GAX160 to 8GAX163 / 4GAX181) or buoyant ROV tether model (DLRB-3TP6C / DATALINE ROV) and length for an immediate subsea quotation.
1SSA6 / 1SSA4 / 7SSA12 / 4SSA40 / 4OMB23 Armored Subsea Tow & Umbilical Cable
1SSA6 (5.82 mm OD, 29.0 kN Break) | 1SSA4 (5.69 mm OD, 26.7 kN Break)
CDUR-06 14-Core Subsea Diving & ROV Umbilical Cable with 75 Ω Coax
CDUR-06 (replaces CDUR-05)
DLR Series 4 to 10-Core Underwater Video & Power ROV Tether Cable
DLR-1P20, 2P20, 3P25, 4P25
Request Quotation & Datasheet for This Cable
Need factory pricing, cross-section drawing or a full PDF datasheet for 2GAX / 4GAX / 6GAX / 8GAX / DLRB-3TP6C Buoyant ROV Tether & DataLine Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.
- ISO 9001 Factory Direct
- MOQ 50 m (Custom Builds)
- 24h Engineering Reply