

1500 V DC Aluminum Solar PV Feeder Cable: PV Al, LSZH, Heavy-Duty & AWA/SWA
PV Al 1500 V DC, PV LSZH Al 1500 V DC, PV LSZH Al 1500 V Heavy Duty and PV AWA/SWA Al 1500 V DC are large-cross-section (1×16 mm² to 1×400 mm² and 2×16 to 2×240 mm²) aluminum DC collector feeder cables engineered to IEC 60502-1 for utility-scale 1,500 V DC photovoltaic power plants. Connecting solar tracker combiner boxes to central inverters or DC-coupled BESS skids.
- Model designationsPV Al 1500 V, PV LSZH Al 1500 V, PV Al Heavy Duty & PV AWA/SWA Al 1500 V
- Reference standardsIEC 60502-1, EN 50618 / UNE 211605 (UV), EN 60754-1/2 (LSZH), IEC 60228
- Rated DC & AC voltage1,500 V DC (max. 1,800 V DC operating) / 0.6/1 kV AC; 6,500 V DC test
- ConductorClass 2 compact stranded (or Class 5 flexible) aluminum, 16 mm² to 400 mm²
- InsulationReinforced-wall 90 °C cross-linked polyethylene (XLPE), +250 °C short-circuit
- Outer sheath / armorBlack/red UV PVC, halogen-free LSZH, AG3 Heavy Duty, or AWA (1C) / SWA (2C) wire armor
- Water & impact ratingAD7 immersion / AD8 submersion; AG3 / AG4 high-impact direct burial
- Operating temperature-40 °C to +90 °C continuous (+120 °C max. overload); 30-year solar design life
PV Al 1500 V DC, PV LSZH Al 1500 V, Heavy Core Identification & Ratings
- Type: EV Charging & Solar Cable
- Model designations: PV Al 1500 V, PV LSZH Al 1500 V, PV Al Heavy Duty & PV AWA/SWA Al 1500 V
- Reference standards: IEC 60502-1, EN 50618 / UNE 211605 (UV), EN 60754-1/2 (LSZH), IEC 60228
- Rated DC & AC voltage: 1,500 V DC (max. 1,800 V DC operating) / 0.6/1 kV AC; 6,500 V DC test
Electrical, Thermal & Mechanical Bend Limits
- Conductor: Class 2 compact stranded (or Class 5 flexible) aluminum, 16 mm² to 400 mm²
- Insulation: Reinforced-wall 90 °C cross-linked polyethylene (XLPE), +250 °C short-circuit
- Outer sheath / armor: Black/red UV PVC, halogen-free LSZH, AG3 Heavy Duty, or AWA (1C) / SWA (2C) wire armor
- Water & impact rating: AD7 immersion / AD8 submersion; AG3 / AG4 high-impact direct burial
- Operating temperature: -40 °C to +90 °C continuous (+120 °C max. overload); 30-year solar design life
PV Al 1500 V DC, PV LSZH Al 1500 V, Heavy Conductor, Insulation & Sheath Build
1500 V DC Aluminum Solar Feeder Cables combine compacted aluminum conductors with reinforced 90 °C XLPE insulation and UV/burial-engineered PVC, LSZH, Heavy-Duty, or AWA/SWA jackets.
- Conductor (Al): Class 2 circular compact stranded aluminum (or Class 5 flexible aluminum on request), 16–400 mm² per IEC 60228.
- Insulation (XLPE): Reinforced-wall 90 °C cross-linked polyethylene (XLPE) rated for 1,500 V DC continuous (1,800 V DC max).
- Inner Bedding / Armor (AWA/SWA): On PV AWA/SWA Al: extruded inner bedding sheath + Aluminum Wire Armor (1-core) or Galvanized Steel Wire Armor (2-core).
- Outer Sheath: UV-stabilized black/red PVC (PV Al), halogen-free polyolefin (PV LSZH Al), thickened AG3 polyolefin (Heavy Duty), or armored outer sheath.
Primary Electrical & Mechanical Performance
- True 1,500 V DC (1,800 V DC max) dielectric: Reinforced XLPE insulation wall withstands continuous 1,500 V DC (1,800 V DC max) bipolar or floating solar bus voltages without DC space-charge breakdown.
- 4 trench-ready outer constructions: Choose standard UV PVC, halogen-free LSZH, Heavy-Duty direct-burial LSZH, or rodent-proof AWA (1-core) / SWA (2-core) wire-armored designs.
- 16 mm² to 400 mm² DC collector sizing: Sized specifically to keep combiner-box-to-inverter DC voltage drop below 1.0%–1.5% across 200 m to 800 m solar tracker rows.
- UV, ozone & AD7/AD8 moisture immunity: Passes EN 50618 / UNE 211605 UV weathering for exposed tracker risers and AD7/AD8 underground water immersion.
Industrial Oil, Flame & Environmental Protection
- Compacted Class 2 aluminum conductor: Circular compact stranded aluminum per IEC 60228 ensures gas-tight crimping in bimetallic solar combiner lugs and inverter busbars.
- Heavy-Duty impact & abrasion shield: PV LSZH Al Heavy Duty increases radial sheath thickness to resist sharp backfill stones and thermal soil movement.
- AWA / SWA metallic wire armor option: PV AWA/SWA Al 1500 V provides AG4 mechanical impact severity and 100% rodent defense for direct-buried DC main feeders.
- Red / Black polarity identification: Supplied with black outer sheath (with optional red co-extruded polarity stripe or red/black core identification) for error-free DC +/− pairing.
IEC / EN / VDE / UL Reference Standards
- IEC 60502-1: 1,500 V DC / 0.6/1 kV AC extruded XLPE insulated power cables
- EN 50618 & UNE 211605: UV weather resistance and 1,500 V DC photovoltaic endurance
- EN 60754-1 / EN 60754-2: Halogen-free LSZH jacket on PV LSZH Al & Heavy Duty series
- IEC 60228 Class 2 compact stranded: or Class 5 flexible) aluminum conductors
Industrial Cable Selection & Routing Guides
- 1500 V DC BESS Battery Energy Storage Cable Guide: Stranding, LSZH Standards & Busbar Sizing
- PV1-F / Dual-Rated String Leads, 1500 V DC Aluminum PV Al Collector Feeders, NF M 87-202 (EGFA / EIFA / EGPF) Acid-Tank and VDE 6Y / 5Y Bath Engineering Guide
- H1Z2Z2-K, EN 50618, IEC 62930 and UL 4703 Solar PV Cable Guide
- 3-Phase AC and DC Voltage Drop Calculation Formula & 20–90 °C Resistance Guide
- IEC 60228 Class 2 Aluminum vs. Copper R₂₀ Resistance & Bimetallic Termination Guide

PV Al 1500 V DC, PV LSZH Al 1500 V, Heavy Industrial Installation & Routing Guide
In utility-scale 1,500 V DC photovoltaic power plants, copper string cables (4 mm² to 10 mm²H1Z2Z2-K 1500 V DC solar wireterminate at string combiner boxes or multi-MPPT harnesses, from where high-current DC collector trunks (50 mm² to 400 mm², carrying 150 A to 650 A DC) run hundreds of meters underground to central inverters or DC-coupled battery containers. Specifying 1500 V DC Aluminum Solar PV Feeder Cables over these long DC collector runs cuts conductor cost by up to 60% and halves drum pulling weight.
To match every trench and soil condition across global solar EPC projects, we manufacture four specialized 1,500 V DC (1,800 V DC max) aluminum feeder constructions under IEC 60502-1: PV Al 1500 V (reinforced XLPE insulation + UV/AD7 PVC jacket, CPR Eca); PV LSZH Al 1500 V (halogen-free polyolefin jacket per EN 60754-1/2); PV LSZH Al 1500 V Heavy Duty (thickened impact-resistant double/reinforced LSZH jacket for direct burial in rocky soil without sand bedding); and PV AWA/SWA Al 1500 V (non-magnetic Aluminum Wire Armor AWA on single-core 1×25–400 mm² or Galvanized Steel Wire Armor SWA on 2-core 2×16–240 mm² for severe rodent, termite, and crushing protection). For MV inverter-to-grid connections, pair with ourRHZ1-OL / RHZ1-2OL 12/20–18/30 kV MV aluminum cables.
Typical Plant, Machine & Infrastructure Circuits
- Single-core 1×70 mm² through 1×400 mm² PV Al 1500 V (+ / − pairs) connect DC string combiner boxes (SCBs) to central inverter skids (2.5 MW to 6.8 MW blocks) and DC-coupled1500 V DC battery energy storage systems (BESS)in desert, agricultural, and coastal utility solar parks.
- PV LSZH Al 1500 V Heavy Duty and PV AWA/SWA Al 1500 V are engineered for mechanized trench plowing in stony desert terrain, rodent- and gopher-infested pastures, and unarmored-prohibited EPC specifications where sand-bedding import is cost-prohibitive.
PV Al 1500 V DC, PV LSZH Al 1500 V, Heavy Specification & Selection FAQ
Why are 1500 V DC Aluminum Solar Feeder Cables used between combiner boxes and central inverters?
While 4–10 mm² tinned copper H1Z2Z2-K cables are ideal for flexible module-to-string-combiner connections, the main DC collector runs from combiner boxes to central inverters require 70–400 mm² cross-sections over distances of 200–800 meters. Using 1500 V DC aluminum feeders reduces cable cost by ~60% and cuts pulling weight in half.
When should PV LSZH Al 1500 V Heavy Duty be chosen over standard PV Al 1500 V?
PV LSZH Al 1500 V Heavy Duty features a reinforced, extra-thick abrasion- and impact-resistant halogen-free polyolefin sheath designed for direct burial in rocky solar farm trenches without importing fine sand bedding.
When is PV AWA/SWA Al 1500 V required?
PV AWA/SWA Al 1500 V adds a full crown of Aluminum Wire Armor (AWA on single-core cables) or Galvanized Steel Wire Armor (SWA on 2-core cables), providing 100% protection against gophers, rats, termites, and heavy vehicle wheel loads across solar farm access roads.
What is the maximum continuous DC voltage of PV Al 1500 V cables?
All four variants are rated for 1,500 V DC nominal and up to 1,800 V DC maximum continuous operating voltage between conductors or between conductor and earth, tested at 6,500 V DC for 5 minutes.
Dimensional, weight, current-rating, and voltage-drop specifications for 1,500 V DC PV Al, PV LSZH Al, Heavy Duty and AWA/SWA Armored aluminum solar feeder cables (16 mm² to 400 mm²).
TEBAOFLEX® — 1500 V DC Aluminum Solar PV Feeder Cable: PV Al, LSZH, Heavy-Duty & AWA/SWA
| Cross-Section (mm²) | Std OD (mm) | Std Weight (kg/km) | Heavy-Duty OD (mm) | Heavy-Duty Weight (kg/km) | Max. DC Res. 20 °C (Ω/km) | Ampacity Open Air 30 °C (A) | Ampacity Buried 20 °C (A) | DC Voltage Drop (V/A·km) |
|---|---|---|---|---|---|---|---|---|
| 1 × 16 Al | 9.5 | 110 | 11.1 | 145 | 1.91 | 97 | 81 | 4.58 |
| 1 × 25 Al | 11.0 | 155 | 12.6 | 195 | 1.20 | 128 | 104 | 2.88 |
| 1 × 35 Al | 12.1 | 195 | 13.7 | 240 | 0.868 | 157 | 125 | 2.08 |
| 1 × 50 Al | 13.6 | 250 | 15.2 | 305 | 0.641 | 192 | 149 | 1.54 |
| 1 × 70 Al | 15.4 | 330 | 17.0 | 390 | 0.443 | 246 | 185 | 1.06 |
| 1 × 95 Al | 17.3 | 430 | 19.1 | 505 | 0.320 | 302 | 221 | 0.768 |
| 1 × 120 Al | 19.0 | 525 | 20.8 | 610 | 0.253 | 352 | 252 | 0.607 |
| 1 × 150 Al | 21.0 | 645 | 22.8 | 740 | 0.206 | 406 | 285 | 0.494 |
| 1 × 185 Al | 23.2 | 795 | 25.0 | 905 | 0.164 | 466 | 322 | 0.394 |
| 1 × 240 Al | 26.0 | 1,020 | 28.0 | 1,150 | 0.125 | 552 | 373 | 0.300 |
| 1 × 300 Al | 28.8 | 1,260 | 30.8 | 1,410 | 0.100 | 636 | 421 | 0.240 |
| 1 × 400 Al | 32.4 | 1,620 | 34.6 | 1,805 | 0.0778 | 742 | 485 | 0.187 |
TEBAOFLEX® — 1500 V DC Aluminum Solar PV Feeder Cable: PV Al, LSZH, Heavy-Duty & AWA/SWA
| Formation (Cores × mm²) | Wire Armor Type | Overall OD (mm) | Approx. Weight (kg/km) | Ampacity Open Air 30 °C (A) | Ampacity Buried 20 °C (A) | DC Voltage Drop (V/A·km) |
|---|---|---|---|---|---|---|
| 1 × 25 Al | Aluminum Wire Armor (AWA) | 16.2 | 340 | 128 | 104 | 2.88 |
| 1 × 50 Al | Aluminum Wire Armor (AWA) | 18.8 | 485 | 192 | 149 | 1.54 |
| 1 × 95 Al | Aluminum Wire Armor (AWA) | 23.0 | 760 | 302 | 221 | 0.768 |
| 1 × 150 Al | Aluminum Wire Armor (AWA) | 27.4 | 1,110 | 406 | 285 | 0.494 |
| 1 × 240 Al | Aluminum Wire Armor (AWA) | 32.8 | 1,640 | 552 | 373 | 0.300 |
| 1 × 300 Al | Aluminum Wire Armor (AWA) | 36.0 | 2,010 | 636 | 421 | 0.240 |
| 1 × 400 Al | Aluminum Wire Armor (AWA) | 40.2 | 2,560 | 742 | 485 | 0.187 |
| 2 × 25 Al | Galv. Steel Wire Armor (SWA) | 24.8 | 1,020 | 108 | 92 | 2.88 |
| 2 × 50 Al | Galv. Steel Wire Armor (SWA) | 29.6 | 1,490 | 162 | 132 | 1.54 |
| 2 × 95 Al | Galv. Steel Wire Armor (SWA) | 37.2 | 2,460 | 252 | 195 | 0.768 |
| 2 × 150 Al | Galv. Steel Wire Armor (SWA) | 44.5 | 3,580 | 338 | 252 | 0.494 |
| 2 × 240 Al | Galv. Steel Wire Armor (SWA) | 54.2 | 5,290 | 458 | 330 | 0.300 |
Selection guide: Specify PV Al 1500 V (PVC), PV LSZH Al 1500 V, PV LSZH Al 1500 V Heavy Duty (direct burial), or PV AWA/SWA Al 1500 V (wire armored), and aluminum cross-section (1×16 to 1×400 mm² or 2×16 to 2×240 mm²). For TÜV 2 PfG 1169 PV1-F, dual-certified PV1-F / UL 4703 PV-Wire (copper and AA-8000 aluminum), and twin parallel or steel-braided rodent-proof solar string cables, seePV1-F, Dual-Rated PV1-F / UL 4703 & Twin Rodent-Resistant Solar PV Cable.
Ordering & Quotation Checklist: Request a factory quotation for 1500 V DC Aluminum Solar PV Feeder Cables — PV Al, PV LSZH Al, Heavy Duty Buried, or PV AWA/SWA Armored (16–400 mm²).
RHZ1-OL, RHZ1-2OL, RHZ1 (S/AS) & RH5Z1 6/10–18/30 kV MV XLPE Power Cable
RHZ1-OL / RHZ1-2OL (AL & CU), RHZ1 (S), RHZ1 (AS), RHZ1 Triplex & RH5Z1-OL/2OL
1500 V DC Battery Energy Storage System (ESS) Flexible Single-Core Power Cable
1500 V DC (1800 V DC max)
FHL2G Unscreened 1000V AC / 1500V DC Silicone EV High-Voltage Cable (ISO 6722)
FHL2G (Unscreened Fine-Stranded High-Voltage Silicone Road Vehicle Cable)
Request Quotation & Datasheet for This Cable
Need factory pricing, cross-section drawing or a full PDF datasheet for 1500 V DC Aluminum Solar PV Feeder Cable: PV Al, LSZH, Heavy-Duty & AWA/SWA? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.
- ISO 9001 Factory Direct
- MOQ 50 m (Custom Builds)
- 24h Engineering Reply
































