FHL2G Unscreened 1000V AC / 1500V DC Silicone EV High-Voltage Cable (ISO 6722)
FHL2G is an unscreened, ultra-flexible 1,000 V AC / 1,500 V DC high-voltage electric vehicle (EV) silicone cable engineered in accordance with ISO 6722, LV 216, and ISO 19642. In the VDE/ISO automotive nomenclature, FH denotes a high-voltage road vehicle.
- Model DesignationFHL2G (Unscreened Fine-Stranded High-Voltage Silicone Road Vehicle Cable)
- Rated Voltage1,000 V AC / 1,500 V DC (600 V / 900 V Core-to-Earth)
- Test Voltage10 kV AC Spark Test / 5 kV AC Dielectric Withstand (5 Minutes)
- Conductor Cross-Section0.50 mm² to 120 mm² Fine-Stranded Bare or Tinned Copper (DIN EN 60228 Class 5)
- Insulation MaterialTear-Resistant Silicone Rubber (2G) — High-Voltage Orange (RAL 2003), Black, Red, or Blue
- Operating Temperature-40°C to +180°C (up to +200°C Short-Term Overload, ISO 6722 Class E / F)
- Minimum Bending Radius3 × to 5 × Overall Cable Diameter (Ultra-Flexible Tight Battery Pack Routing)
- Supply FormatCustom Cut Lengths, Export Wooden Drums, and OEM Harnessing
FHL2G Unscreened 1000V AC / 1500V DC E-Mobility & Traction Specification
- Type: EV High-Voltage & Charging Cables
- Model Designation: FHL2G (Unscreened Fine-Stranded High-Voltage Silicone Road Vehicle Cable
- Rated Voltage: 1,000 V AC / 1,500 V DC (600 V / 900 V Core-to-Earth
- Test Voltage: 10 kV AC Spark Test / 5 kV AC Dielectric Withstand (5 Minutes
DC/AC High-Voltage & Thermal Class Ratings
- Conductor Cross-Section: 0.50 mm² to 120 mm² Fine-Stranded Bare or Tinned Copper (DIN EN 60228 Class 5
- Insulation Material: Tear-Resistant Silicone Rubber (2G) — High-Voltage Orange (RAL 2003), Black, Red, or Blue
- Operating Temperature: -40°C to +180°C (up to +200°C Short-Term Overload, ISO 6722 Class E / F
- Minimum Bending Radius: 3 × to 5 × Overall Cable Diameter (Ultra-Flexible Tight Battery Pack Routing
- Supply Format: Custom Cut Lengths, Export Wooden Drums, and OEM Harnessing
FHL2G Unscreened 1000V AC / 1500V DC Fine-Stranded & EMC-Screened Build
FHL2G combines high-purity oxygen-free fine copper stranding with a tear-resistant, single-extrusion or co-extruded high-voltage silicone elastomer wall.
- Conductor: Fine-stranded bare copper or tinned copper according to DIN EN 60228 Class 5 (optional Class 6 extra-flexible rope lay on 25–120 mm²).
- Separator Film: Optional polyester release tape on >= 16 mm² sizes for clean high-speed automated stripping and ultrasonic welding.
- Insulation: High-dielectric-strength, tear-resistant silicone rubber (2G) rated 1,000 V AC / 1,500 V DC (-40°C to +180°C).
- Color Coding: Standard HV Orange (RAL 2003) for exterior high-voltage identification; Black, Red, or Blue for internal battery pack bus interconnects.
High-Voltage Dielectric & Flex Routing Performance
- Voltage Rating: 1,000 V AC / 1,500 V DC
- Size Schedule: 0.50 mm² to 120 mm² (Class 5 Cu
- Insulation System: 2G Silicone Rubber (-40°C to +180°C
- Standard Color: HV Orange (RAL 2003) / Red / Black
Battery Fluid, Thermal Shock & Ozone Endurance
- True 1,000 V AC / 1,500 V DC High-Voltage Rating:: Engineered for 800 V and 1,000 V EV architectures with a 5 kV AC 5-minute dielectric withstand test and 10 kV spark test.
- Extreme -40°C to +180°C Silicone Thermal Class:: Meets ISO 6722 Class E (+175°C) and Class F (+200°C) thermal aging requirements without halogen plasticizers.
- Complete 0.50 mm² to 120 mm² Single-Core Range:: Covers both BMS cell-tap / HVIL sense leads (0.5–2.5 mm²), auxiliary PTC heater / e-compressor feeds (4–16 mm²), and main battery-to-inverter links (25–120 mm²).
- Halogen-Free & Flame-Retardant per ISO 6722:: Self-extinguishing silicone compound passes ISO 6722 45-degree flame propagation testing with low smoke and zero corrosive halogens.
ISO 19642 / ISO 6722 / EN 50620 EV Standards
- ISO 6722-1 Class E / Class F: Road vehicle single-core high-temperature silicone cable standard (-40°C to +180°C/+200°C).
- ISO 19642-5 / LV 216: High-voltage 1,000 V AC / 1,500 V DC electric vehicle cable dimensions and dielectric testing.
- DIN EN 60228 / IEC 60228 Class 5: Fine-stranded flexible bare or tinned copper conductors.
- IEC 60754-1/2: Halogen-free and non-corrosive combustion gas compliance.
EV High-Voltage & Charging Cable Guides

FHL2G Unscreened 1000V AC / 1500V DC Traction Harness & Charging Architecture
FHL2G is an unscreened, ultra-flexible 1,000 V AC / 1,500 V DC high-voltage electric vehicle (EV) silicone cable engineered in accordance with ISO 6722, LV 216, and ISO 19642. In the VDE/ISO automotive nomenclature, FH denotes a high-voltage road vehicle conductor, L indicates fine-wire flexible stranding, and 2G specifies a heat-resistant silicone rubber insulation system rated for continuous service from -40°C to +180°C (+200°C peak).
Inside enclosed metal EV battery packs, battery disconnect units (BDUs), power distribution units (PDUs), and fuel-cell stacks—or when routed through outer corrugated metallic EMC conduits—individual braided cable shielding is unnecessary and adds unwanted stiffness and termination weight. FHL2G unscreened silicone cable allows tight 3×D to 5×D bending radii between lithium-ion cell modules, contactors, pyro-fuses, and HV service disconnects without exerting mechanical stress on bolted busbar terminals. We manufacture the complete FHL2G gauge schedule from 0.50 mm² and 0.75 mm² BMS voltage-sense leads up to 35 mm², 50 mm², 70 mm², 95 mm², and 120 mm² main battery traction interconnects in high-visibility RAL 2003 Orange (as well as Black, Red, and Blue for internal DC+/DC- polarity identification). For UL-recognized EV battery wire, see ourUL 3287 XLPE EV Battery WireandUL 3135 600V 200°C Silicone Hook-Up Wire, or check our1500V DC Energy Storage System (ESS) Battery Cable.
EV Battery Packs, Inverters & Charging Stations
- As electric passenger cars, commercial e-trucks, and heavy off-highway machinery transition from 400 V to 800 V–1,000 V silicon-carbide (SiC) architectures, internal battery pack wiring must withstand 1,500 V DC continuous working voltage and +180°C thermal spikes during fast DC supercharging.
- Because silicone rubber (2G) maintains a constant low elastic modulus from -40°C to +180°C, FHL2G installs effortlessly in automated battery module assembly cells and absorbs road vibration between the chassis and e-axle components.
FHL2G Unscreened 1000V AC / 1500V DC Automotive & EV Engineering FAQ
What is the difference between FHL2G and FHLR2GCB2G?
FHL2G is the unscreened single-insulated high-voltage silicone wire used inside shielded metallic battery enclosures, PDUs, or EMC conduits. FHLR2GCB2G adds an aluminum-mylar foil screen, a tinned copper braid shield (CB), and an outer silicone jacket (2G) for exposed under-body EV routing.
Can FHL2G be used in 800 V and 1,000 V electric vehicle battery packs?
Yes. FHL2G is rated for 1,000 V AC and 1,500 V DC continuous working voltage and undergoes a 5 kV AC 5-minute dielectric withstand test and a 10 kV spark test, providing full safety margin for 800 V and 1,000 V EV battery architectures.
Should I specify bare copper or tinned copper for FHL2G?
Both are supported in Datasheet #116. Bare copper offers slightly lower DC resistance and is widely used with ultrasonic welding and standard closed-barrel compression lugs. Tinned copper is preferred in high-humidity marine/bus applications or where silver/tin-plated terminals are specified.
Why is FHL2G preferred over XLPE (FHLR91X) inside battery module interconnects?
Cross-linked polyethylene (XLPE) is relatively stiff in large cross-sections (35 mm2 to 120 mm2), transferring mechanical torque onto battery module M8/M10 busbar studs. Silicone (FHL2G) is ultra-limp down to -40°C, allowing 3×D bends inside compact battery trays without stressing cell terminals.
Complete conductor stranding, resistance, insulation thickness, and outer diameter specifications below are extracted directly from TEBAOFLEX engineering datasheet #116 (FHL2G 1000V AC / 1500V DC).
TEBAOFLEX® — FHL2G 1000V AC / 1500V DC Silicone EV Cable — Small & Auxiliary Gauges (0.50 mm² to 10 mm², Datasheet #116)
| Nominal Cross-Section | Max. Strand Dia. (mm) | Max. Conductor Dia. (mm) | Max. DCR @ 20°C (Bare / Tinned Ω/km) | Min. Insulation Wall (mm) | Nominal Outer Dia. (mm) | Approx. Weight (kg/km) |
|---|---|---|---|---|---|---|
| 1 × 0.50 mm² | 0.21 mm | 1.0 mm | 37.1 / 38.2 Ω/km | 0.64 mm | 2.30 ± 0.10 mm | 10 kg/km |
| 1 × 0.75 mm² | 0.21 mm | 1.2 mm | 24.7 / 25.4 Ω/km | 0.64 mm | 2.50 ± 0.10 mm | 13 kg/km |
| 1 × 1.00 mm² | 0.21 mm | 1.35 mm | 18.5 / 19.1 Ω/km | 0.64 mm | 2.70 ± 0.10 mm | 16 kg/km |
| 1 × 1.50 mm² | 0.26 mm | 1.70 mm | 12.7 / 13.0 Ω/km | 0.64 mm | 3.00 ± 0.10 mm | 21 kg/km |
| 1 × 2.50 mm² | 0.26 mm | 2.20 mm | 7.60 / 7.82 Ω/km | 0.72 mm | 3.60 ± 0.10 mm | 33 kg/km |
| 1 × 4.00 mm² | 0.31 mm | 2.75 mm | 4.71 / 4.85 Ω/km | 0.72 mm | 4.20 ± 0.10 mm | 48 kg/km |
| 1 × 6.00 mm² | 0.31 mm | 3.30 mm | 3.14 / 3.23 Ω/km | 0.72 mm | 5.00 ± 0.20 mm | 69 kg/km |
| 1 × 10.0 mm² | 0.41 mm | 4.50 mm | 1.82 / 1.85 Ω/km | 0.96 mm | 6.50 ± 0.20 mm | 117 kg/km |
TEBAOFLEX® — FHL2G 1000V AC / 1500V DC Silicone EV Cable — Traction Power Gauges (16 mm² to 120 mm², Datasheet #116)
| Nominal Cross-Section | Max. Strand Dia. (mm) | Max. Conductor Dia. (mm) | Max. DCR @ 20°C (Bare / Tinned Ω/km) | Min. Insulation Wall (mm) | Nominal Outer Dia. (mm) | Approx. Weight (kg/km) |
|---|---|---|---|---|---|---|
| 1 × 16.0 mm² | 0.41 mm | 5.80 mm | 1.16 / 1.18 Ω/km | 0.96 mm | 8.20 ± 0.20 mm | 182 kg/km |
| 1 × 25.0 mm² | 0.41 mm | 7.20 mm | 0.743 / 0.757 Ω/km | 1.04 mm | 9.60 ± 0.20 mm | 270 kg/km |
| 1 × 35.0 mm² | 0.41 mm | 8.50 mm | 0.527 / 0.538 Ω/km | 1.04 mm | 11.50 ± 0.30 mm | 380 kg/km |
| 1 × 50.0 mm² | 0.41 mm | 10.50 mm | 0.368 / 0.375 Ω/km | 1.20 mm | 13.50 ± 0.30 mm | 535 kg/km |
| 1 × 70.0 mm² | 0.51 mm | 12.50 mm | 0.259 / 0.264 Ω/km | 1.20 mm | 15.50 ± 0.30 mm | 735 kg/km |
| 1 × 95.0 mm² | 0.51 mm | 14.80 mm | 0.196 / 0.200 Ω/km | 1.44 mm | 18.00 ± 0.40 mm | 990 kg/km |
| 1 × 120.0 mm² | 0.51 mm | 16.50 mm | 0.153 / 0.156 Ω/km | 1.44 mm | 20.20 ± 0.40 mm | 1,240 kg/km |
Selection guide: Both bare copper (blank) and tinned copper (verzinkt/tinned) conductors are available across all 15 sizes from 0.50 mm² to 120 mm². For water-blocked low-voltage sensor harnesses and high-voltage EV traction leads, compare180B ISO Class D / GXL-WB / TXL-WB anti-capillary automotive wire,HLR2GCB2G shielded silicone automotive powertrain cable, and ourAC vs DC EV charging cable guide.
Ordering & Quotation Checklist: Specify your required FHL2G cross-section (0.50 mm2 to 120 mm2), conductor finish (bare or tinned copper), insulation color (RAL 2003 Orange, Red, or Black), and reel length for an immediate EV quotation.
1500 V DC Battery Energy Storage System (ESS) Flexible Single-Core Power Cable
1500 V DC (1800 V DC max)
H1Z2Z2-K 1500V DC Solar PV Cable: EN 50618 & IEC 62930 Photovoltaic Wire
1.5 kV DC (1.8 kV DC max)
1500 V DC Aluminum Solar PV Feeder Cable: PV Al, LSZH, Heavy-Duty & AWA/SWA
PV Al 1500 V, PV LSZH Al 1500 V, PV Al Heavy Duty & PV AWA/SWA Al 1500 V
Request Quotation & Datasheet for This Cable
Need factory pricing, cross-section drawing or a full PDF datasheet for FHL2G Unscreened 1000V AC / 1500V DC Silicone EV High-Voltage Cable (ISO 6722)? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.
- ISO 9001 Factory Direct
- MOQ 50 m (Custom Builds)
- 24h Engineering Reply