EN 50288-7 Mica Fire-Resistant Inst. & Al/HDPE / Lead-Sheath Petrochem Cable
Engineered for oil & gas refineries, LNG liquefaction trains, aromatic hydrocarbon tank farms, and emergency shutdown (ESD / SIS) loops, this petrochemical cable series unites EN 50288-7 300/500 V Mica-Tape + XLPE/HEPR Fire-Resistant (IEC 60331-21 750 °C) OS & ISOS Screened SWA/GSWB Instrumentation Cables with Multi-Layer Aluminum/HDPE/Polyamide (Al/HDPE/PA) Chemical-Barrier Cables and Lead-Alloy Sheathed (Pb / E-Pb, EN.
- Applicable standardsEN 50288-7, IEC 60331-21 (750 °C Fire), EN 50307 (Lead Alloy), IEC 60502-1 / IEC 60502-2
- Voltage ratings300/500 V (EN 50288-7 Fire Inst.); 0.6/1 kV to 18/30 kV (Al/HDPE & Lead-Sheathed Power/Control)
- Fire integrity barrierHelical phlogopite mica-glass tape + 90 °C XLPE or HEPR insulation (IEC 60331-21 90–180 min at 750 °C)
- Chemical barrier (Lead-Free)Longitudinally copolymer-bonded Aluminum tape (0.2 mm) + high-density PE (HDPE) + Polyamide (PA) nylon layer
- Metallic sheath (Traditional)Seamless extruded E-Pb / Cu-Te Lead Alloy sheath per EN 50307 (100% impervious to benzene, toluene, xylene & H2S)
- EMC screeningCollective Aluminum/PET tape screen (OS) or Individual & Collective screen (ISOS) with tinned copper drain wire
- Mechanical armorGalvanized steel wire armor (SWA), galvanized steel wire braid (GSWB), or double steel tape armor (STA)
- Outer jacket optionsHydrocarbon/UV-resistant PVC, HDPE, or Low-Smoke Zero-Halogen (LSZH, IEC 60332-3-22 Cat A)
EN 50288-7 Mica Fire-Resistant Signal & Bus Architecture
- Type: Flexible Control Cable
- Applicable standards: EN 50288-7, IEC 60331-21 (750 °C Fire), EN 50307 (Lead Alloy), IEC 60502-1 / IEC 60502-2
- Voltage ratings: 300/500 V (EN 50288-7 Fire Inst.); 0.6/1 kV to 18/30 kV (Al/HDPE & Lead-Sheathed Power/Control
- Fire integrity barrier: Helical phlogopite mica-glass tape + 90 °C XLPE or HEPR insulation (IEC 60331-21 90–180 min at 750 °C
Impedance, Attenuation & Operating Limits
- Chemical barrier (Lead-Free): Longitudinally copolymer-bonded Aluminum tape (0.2 mm) + high-density PE (HDPE) + Polyamide (PA) nylon layer
- Metallic sheath (Traditional): Seamless extruded E-Pb / Cu-Te Lead Alloy sheath per EN 50307 (100% impervious to benzene, toluene, xylene & H2S
- EMC screening: Collective Aluminum/PET tape screen (OS) or Individual & Collective screen (ISOS) with tinned copper drain wire
- Mechanical armor: Galvanized steel wire armor (SWA), galvanized steel wire braid (GSWB), or double steel tape armor (STA
- Outer jacket options: Hydrocarbon/UV-resistant PVC, HDPE, or Low-Smoke Zero-Halogen (LSZH, IEC 60332-3-22 Cat A
EN 50288-7 Mica Fire-Resistant Pair Twist, Foil & Braid Construction
Designed for simultaneous fire survival and hydrocarbon chemical immunity in onshore oil, gas, and chemical complexes.
- Conductor: Class 2 stranded plain or tinned annealed copper per IEC 60228 (0.5–2.5 mm² inst.; 1.5–400 mm² power).
- Fire Barrier & Insulation: Helical phlogopite mica-glass tape (on fire-resistant types) + 90 °C XLPE or HEPR thermoset insulation.
- Screening (Instrumentation): Collective Al/PET foil (OS) or individual + collective Al/PET foil (ISOS) with 0.5 mm² tinned copper drain wire.
- Chemical / Moisture Barrier: Longitudinally bonded 0.2 mm Aluminum tape + Polyamide (PA) + HDPE laminate, OR seamless EN 50307 extruded E-Pb lead sheath.
- Armor & Outer Sheath: Galvanized steel wire armor (SWA), braid (GSWB), or double steel tape (STA) + hydrocarbon-resistant PVC, HDPE, or orange/black LSZH.
Signal Integrity, Crosstalk & Noise Rejection
- IEC 60331-21 (750 °C) Circuit Integrity: Phlogopite mica-glass tape + XLPE/HEPR core insulation keeps ESD, fire & gas (F&G), and DCS instrumentation loops operational during hydrocarbon fires.
- Al/HDPE/PA Lead-Free Chemical Barrier: Bonded aluminum tape + polyamide nylon + HDPE multi-layer barrier blocks aromatic hydrocarbons, solvents, and moisture without heavy lead.
- EN 50307 Extruded Lead-Alloy Sheath (Pb): Seamless E-Pb or Tellurium-Copper lead alloy sheath provides absolute zero permeability against concentrated BTX aromatics, acids, and sour gas.
- SWA / STA / GSWB Heavy Mechanical Armor: Galvanized steel wire armor (SWA), double steel tape armor (STA), or wire braid (GSWB) protects direct-buried trenches and blast-zone racks.
Process Plant, Moisture, UV & Chemical Protection
- OS & ISOS EMC rejection (<100 pF/m): Low mutual capacitance XLPE/HEPR dielectric and 100% Al/PET foil screens prevent crosstalk on 4–20 mA, thermocouple RTD, and digital bus lines.
- Choice of Al/HDPE/PA or E-Pb Lead sheath: Specify eco-friendly lightweight Al/HDPE/PA laminate for modern EPC specs (Shell DEP / Total GS) or seamless EN 50307 lead sheath for legacy refinery standards.
- Full LV/MV power, control & inst. coverage: Available across 300/500 V instrumentation pairs/triads, 0.6/1 kV multi-core control/power, and 3.6/6 kV to 18/30 kV medium-voltage feeders.
- Complementary tunnel & fire safety range: Pair with ourIEC 60331-25 fire-resistant stainless-steel tube optical cablesandUK BS 7846 F2/F120 armored fire cables.
EN 50288 / PAS 5308 / Fieldbus Protocol Standards
- EN 50288-7: Multi-element metallic cables for analogue and digital instrumentation and control — 300/500 V
- IEC 60331-21 / EN 50200 PH120: Fire circuit integrity at 750 °C–830 °C for 90–180 minutes
- EN 50307 & IEC 60502-1 / 60502-2: Lead-alloy sheaths and Al/HDPE/PA chemical-moisture barriers
- IEC 60332-3-22 Cat A, IEC 60754-1/2 & IEC 61034-2: Bunched flame retardancy, halogen-free & low smoke
Instrumentation & Industrial Bus Guides

EN 50288-7 Mica Fire-Resistant Process Control & Telemetry Topology
In onshore crude oil refineries, petrochemical steam crackers, and sour-gas processing plants, instrumentation and power cables face two simultaneous threats: hydrocarbon pool fires above ground and aromatic solvent / aliphatic chemical permeation in contaminated soil trenches. Our EN 50288-7 300/500 V Mica-Tape Fire-Resistant Instrumentation Cable (1 to 36 pairs/triads, 0.5 to 2.5 mm²) wraps each Class 2 plain or tinned copper conductor in a phlogopite mica-glass fire barrier beneath 90 °C XLPE or HEPR insulation. Available in Collective Screen (OS — RE-2X(St)HMF / RE-2X(St)HSWAH-M) and Individual + Collective Screen (ISOS — RE-2X(St)H-PIMFM), it maintains uninterrupted 4–20 mA HART, Foundation Fieldbus, and ESD valve trip signals for 90 to 180 minutes at 750 °C under IEC 60331-21.
For direct burial in soil saturated with benzene, toluene, xylene (BTX), jet fuel, acids, and hydrogen sulfide (H2S), we manufacture both Traditional Extruded Lead-Alloy Sheathed (Pb / E-Pb, EN 50307) SWA/STA Cables and lightweight Lead-Free Multi-Layer Al/HDPE/PA Chemical & Moisture Barrier Cables (0.6/1 kV to 18/30 kV). The Al/HDPE/PA construction bonds a 0.20 mm longitudinal copolymer-coated aluminum foil to an inner Polyamide (PA) nylon barrier and an outer High-Density Polyethylene (HDPE) sheath—achieving lead-equivalent chemical impermeability at 40% lower cable weight. Compare with our standardEN 50288-7 OS & ISOS instrumentation cablesandIEC 60331-21 mica fire-resistant power cables.
DCS, PLC, Fieldbus & Sensor Network Routes
- EN 50288-7 Mica Fire-Resistant Instrumentation Cables wire Safety Instrumented Systems (SIS / SIL-3), emergency blowdown valves, flame/gas detectors, and high-integrity pressure protection systems (HIPPS) across refineries, LNG terminals, and chemical plants.
- Al/HDPE/PA Multi-Layer Barrier & Lead-Sheathed (Pb) Cables (300/500 V to 18/30 kV) are installed in direct-buried tank farm trenches, underground pipe racks, and contaminated refinery brownfields where groundwater contains dissolved hydrocarbons.
EN 50288-7 Mica Fire-Resistant Impedance, Grounding & Bus FAQ
When should we specify Al/HDPE/PA multi-layer barrier instead of an extruded lead sheath (Pb)?
Both block aromatic hydrocarbons (BTX), solvents, and moisture in direct-buried refinery trenches. Al/HDPE/PA (0.2 mm copolymer-bonded aluminum + polyamide nylon + HDPE) is lead-free, 35–45% lighter, and easier to pull over long pipe-rack runs, whereas seamless EN 50307 E-Pb lead sheath remains mandatory where legacy refinery specifications require a metallic sheath immune to concentrated acids and H2S.
How does the EN 50288-7 mica fire-resistant instrumentation cable pass IEC 60331-21 at 750 °C?
Each copper conductor is helically lapped with calcination-resistant phlogopite mica-glass tape before XLPE/HEPR extrusion. During a 750 °C fire, the mica vitrifies into an inorganic dielectric shell that prevents conductor-to-conductor and conductor-to-screen short circuits.
What is the difference between OS and ISOS screening in EN 50288-7 cables?
OS (Overall Screen) applies a single collective Al/PET tape screen over all twisted pairs/triads. ISOS (Individual and Overall Screen) wraps each individual pair/triad in its own numbered Al/PET foil plus a collective outer screen to eliminate pair-to-pair crosstalk between 4–20 mA analog and pulsing digital signals.
What outer sheath color is standard for fire-resistant and petrochemical instrumentation cables?
Fire-resistant IEC 60331-21 cables are supplied with an Orange or Red LSZH sheath for emergency circuit identification; non-intrinsically safe circuits use Black, and Intrinsically Safe (Ex i) circuits use Light Blue (RAL 5015).
Pair/triad geometry, mica fire-barrier construction, Al/HDPE/PA moisture-chemical laminate thickness, lead-alloy sheath wall, and SWA/STA armor data for petrochemical instrumentation and power cables.
TEBAOFLEX® — EN 50288-7 Mica Fire-Resistant Inst. & Al/HDPE / Lead-Sheath Petrochem Cable
| Model Code | Pairs × Cross-Section | Screening Type | Mica + XLPE Wall (mm) | SWA Wire Dia. (mm) | Nominal OD (mm) | Net Weight (kg/km) | Max DC Resistance 20 °C (Ω/km) |
|---|---|---|---|---|---|---|---|
| RE-2X(St)HSWAH-M | 1P × 1.0 mm² | Collective Foil (OS) | 0.4 + 0.6 | 0.90 | 13.2 | 335 | 18.1 |
| RE-2X(St)HSWAH-M | 2P × 1.0 mm² | Collective Foil (OS) | 0.4 + 0.6 | 0.90 | 16.8 | 490 | 18.1 |
| RE-2X(St)HSWAH-M | 5P × 1.0 mm² | Collective Foil (OS) | 0.4 + 0.6 | 1.25 | 22.4 | 920 | 18.1 |
| RE-2X(St)HSWAH-M | 10P × 1.5 mm² | Collective Foil (OS) | 0.4 + 0.6 | 1.25 | 29.5 | 1,540 | 12.1 |
| RE-2X(St)H-PIMFM-SWA | 5P × 1.5 mm² | Ind. + Coll. Foil (ISOS) | 0.4 + 0.6 | 1.25 | 25.2 | 1,160 | 12.1 |
| RE-2X(St)H-PIMFM-SWA | 12P × 1.5 mm² | Ind. + Coll. Foil (ISOS) | 0.4 + 0.6 | 1.60 | 35.4 | 2,280 | 12.1 |
| RE-2X(St)H-PIMFM-SWA | 24P × 1.5 mm² | Ind. + Coll. Foil (ISOS) | 0.4 + 0.6 | 1.60 | 46.0 | 3,690 | 12.1 |
TEBAOFLEX® — EN 50288-7 Mica Fire-Resistant Inst. & Al/HDPE / Lead-Sheath Petrochem Cable
| Construction Series | Voltage Rating | Cores / Pairs × Size | Chemical Barrier Structure | Armor Type | Nominal OD (mm) | Net Weight (kg/km) |
|---|---|---|---|---|---|---|
| Inst. Al/HDPE/PA + SWA | 300/500 V | 10P × 1.5 mm² (ISOS) | 0.2 mm Bonded Al + PA Nylon + HDPE | 1.25 mm SWA | 31.0 | 1,620 |
| Inst. Lead-Sheath (Pb) + SWA | 300/500 V | 10P × 1.5 mm² (ISOS) | 1.4 mm Extruded E-Pb Lead Alloy | 1.25 mm SWA | 32.8 | 2,890 |
| LV Control Al/HDPE/PA + SWA | 0.6/1 kV | 12C × 2.5 mm² | 0.2 mm Bonded Al + PA Nylon + HDPE | 1.25 mm SWA | 24.6 | 1,180 |
| LV Power Al/HDPE/PA + SWA | 0.6/1 kV | 4C × 70 mm² | 0.2 mm Bonded Al + PA Nylon + HDPE | 1.60 mm SWA | 38.5 | 3,640 |
| LV Power Lead-Sheath (Pb) + STA | 0.6/1 kV | 4C × 70 mm² | 1.8 mm Extruded E-Pb Lead Alloy | 2 × 0.5 mm STA | 40.2 | 5,420 |
| MV Power Al/HDPE/PA + SWA | 6/10 (12) kV | 3C × 185 mm² | 0.2 mm Bonded Al + PA Nylon + HDPE | 2.50 mm SWA | 66.0 | 8,950 |
Selection guide: Specify EN 50288-7 mica fire-resistant OS/ISOS instrumentation cable (300/500 V), or choose Al/HDPE/PA laminate vs. EN 50307 lead sheath (Pb) for direct-buried petrochemical trenches.
Ordering & Quotation Checklist: Request a technical quotation for EN 50288-7 mica fire-resistant instrumentation cables or Al/HDPE/PA and lead-sheathed (Pb) petrochemical cables.
IEC 60331-25 Fire-Resistant Tunnel, MASS, Phase-Wrapped & Figure-8 Optical Cable
IEC 60331-25 (Optical Fire Integrity), IEC 60794-1-2, IEC 60794-3, IEEE 1222, ITU-T G.652.D / G.657.A1 / OM3 / OM4
UK BS 7846 F2/F120 SWA/AWA, BS 6387 CWZ Single-Core & BS 5839 PH120 Fire Cable
BS 7846 (Cat F2 & Cat F120), BS 8491 (Large-Diameter Power Fire Test), BS 6387 CWZ, BS 8434-2 (Enhanced PH120)
00/12/FO2, RMP200 & 6XM524 Pipe Crawler & C-3400 / 26XM520 Cleaning Robot Cable
00/12/FO2, 00/20/FOX2 (Electro-Optical), 524/11 (11-Core Copper), RMP200 / RMP300 / RMP350 / RMP500, 6XM524, 1HRS347