Individually and Overall Screened Instrumentation Cable

Individually and overall screened instrumentation cable combines separately foil-screened twisted pairs with a second overall foil screen for 75 V signal circuits. Rated voltage: 75 V Nominal signal conductor area: 0.5 mm² Signal conductor construction: 7 × 0.29 mm tinned copper DC conductor resistance: 42 Ω/km Characteristic impedance: 70 Ω at 10 MHz

  • Rated voltage75 V
  • Nominal signal conductor area0.5 mm²
  • Signal conductor construction7 × 0.29 mm tinned copper
  • DC conductor resistance42 Ω/km
  • Characteristic impedance70 Ω at 10 MHz
  • Typical operating capacitance85 nF/km
  • Operating temperature-20 to +70 °C
  • Pairs × (signal + drain) × mm²Nominal OD (mm)

Individually and Overall Screened Signal & Bus Architecture

  • Type: Industrial Cables
  • Rated voltage: 75 V
  • Nominal signal conductor area: 0.5 mm²
  • Signal conductor construction: 7 × 0.29 mm tinned copper

Impedance, Attenuation & Operating Limits

  • DC conductor resistance: 42 Ω/km
  • Characteristic impedance: 70 Ω at 10 MHz
  • Typical operating capacitance: 85 nF/km
  • Operating temperature: -20 to +70 °C
  • Pairs × (signal + drain) × mm²: Nominal OD (mm

Individually and Overall Screened Pair Twist, Foil & Braid Construction

The representative four-pair section shows eight insulated cores, four individual pair screen boundaries and one overall screen. It contains no copper braid or steel armor. The diagram separates the drain positions for identification.

  • Signal conductors: Tinned copper, nominal 0.5 mm²; 7 × 0.29 mm.
  • Insulation / identification: PE; nominal insulated diameter 1.6 mm; blue/red selected pair construction.
  • Individual pair screen: Aluminum/polyester foil, tinned-copper drain wire and polyester wrapping.
  • Overall screen: Aluminum/polyester foil with a separate drain wire.
  • Outer sheath: PVC or low-smoke halogen-free flame-retardant compound.

Signal Integrity, Crosstalk & Noise Rejection

  • Installation and connection: Use the equipment bonding and EMC design to define screen connections.
  • Count signal cores and screen connections separately: The representative four-pair build has eight insulated signal conductors and five screen-drain connections: one for each pair and one for the overall screen.
  • Operating temperature: -20 to +70 °C
  • Pairs × (signal + drain) × mm²: Nominal OD (mm

Process Plant, Moisture, UV & Chemical Protection

  • Selection point: Information to specify
  • Pair screen allocation: Screening requirement of each instrument loop
  • Drain identification: Four pair drains plus one overall drain in the illustrated four-pair build
  • Terminal enclosure: Pair count, finished OD and screen-tail space

EN 50288 / PAS 5308 / Fieldbus Protocol Standards

  • Reference / performance: Applicable condition
  • IEC 60332-1: Single-cable flame-retardance reference for the specified construction.
  • Individual plus overall foil screening: Separate screen boundaries and drain connections as listed in Construction.
  • 75 V instrumentation duty: Use the specified operating voltage, temperature and pair data for the selected build.

Instrumentation & Industrial Bus Guides

Industrial automation control wiring in its equipment environment
Equipment environment and supported cable routing for the stated application. Select the actual cable and connection for the installation duty.

Individually and Overall Screened Process Control & Telemetry Topology

Individually and overall screened instrumentation cable combines separately foil-screened twisted pairs with a second overall foil screen for 75 V signal circuits. Seven-wire tinned-copper conductors and PE insulation form the selected blue/red pair construction, with PVC or low-smoke halogen-free flame-retardant outer sheath options.

The individual screens establish a separate boundary around each pair, while the overall screen surrounds the complete assembly. That arrangement requires a clear termination schedule for both levels. Pair drain wires and the overall drain are connection elements of the screen system; they are additional to the two insulated signal conductors in each pair.

DCS, PLC, Fieldbus & Sensor Network Routes

  • For instrumentation and process-control signal circuits where both pair-level screening and an overall screen are specified.
  • Selection point: Information to specify
  • Pair screen allocation: Screening requirement of each instrument loop
  • Drain identification: Four pair drains plus one overall drain in the illustrated four-pair build
  • Terminal enclosure: Pair count, finished OD and screen-tail space

Installation and connection

Use the equipment bonding and EMC design to define screen connections. Two screening levels alone do not establish the installed interference result; routing, terminations and the connected instrument remain part of the complete circuit.

Individually and Overall Screened Impedance, Grounding & Bus FAQ

How does Individually and Overall Screened Instrumentation Cable handle installation and connection in field installations?

Use the equipment bonding and EMC design to define screen connections. Two screening levels alone do not establish the installed interference result; routing, terminations and the connected instrument remain part of the complete circuit.

Why is 'Count signal cores and screen connections separately' critical when specifying Individually and Overall Screened Instrumentation Cable?

The representative four-pair build has eight insulated signal conductors and five screen-drain connections: one for each pair and one for the overall screen. Its typical cable capacitance over 100 m is about 8.5 nF per applicable circuit at 85 nF/km. Both checks help size the termination and review instrument loading.

What layer-by-layer materials and screening options define Individually and Overall Screened Instrumentation Cable?

Signal conductors: Tinned copper, nominal 0.5 mm²; 7 × 0.29 mm.; Insulation / identification: PE; nominal insulated diameter 1.6 mm; blue/red selected pair construction.; Individual pair screen: Aluminum/polyester foil, tinned-copper drain wire and polyester wrapping.; Overall screen: Aluminum/polyester foil with a separate drain wire.; Outer sheath: PVC or low-smoke halogen-free flame-retardant compound.

What operating voltage, test voltage, and bend-space allowances apply to Individually and Overall Screened Instrumentation Cable?

Rated voltage: 75 V; Nominal signal conductor area: 0.5 mm²; Signal conductor construction: 7 × 0.29 mm tinned copper; DC conductor resistance: 42 Ω/km; Characteristic impedance: 70 Ω at 10 MHz

Nominal selection data for the listed constructions. D means the finished cable outside diameter. Match the complete configuration and test conditions to the ordered cable.

TEBAOFLEX® — Individually and Overall Screened Instrumentation Cable Construction, Operating & Compliance Matrix

Individually and Overall Screened Instrumentation Cable 4-Column Engineering Schedule
Cable Element / Layer Selected Construction Operating Parameter / Condition Normative Reference & Test Scope
Signal conductors Tinned copper, nominal 0.5 mm²; 7 × 0.29 mm. Rated voltage: 75 V IEC 60332-1 — Single-cable flame-retardance reference for the specified construction.
Insulation / identification PE; nominal insulated diameter 1.6 mm; blue/red selected pair construction. Nominal signal conductor area: 0.5 mm² Individual plus overall foil screening — Separate screen boundaries and drain connections as listed in Construction.
Individual pair screen Aluminum/polyester foil, tinned-copper drain wire and polyester wrapping. Signal conductor construction: 7 × 0.29 mm tinned copper 75 V instrumentation duty — Use the specified operating voltage, temperature and pair data for the selected build.
Overall screen Aluminum/polyester foil with a separate drain wire. DC conductor resistance: 42 Ω/km IEC 60332-1 — Single-cable flame-retardance reference for the specified construction.
Outer sheath PVC or low-smoke halogen-free flame-retardant compound. Characteristic impedance: 70 Ω at 10 MHz Individual plus overall foil screening — Separate screen boundaries and drain connections as listed in Construction.

TEBAOFLEX® — Individually and Overall Screened Instrumentation Cable technical parameters

Individually and Overall Screened Instrumentation Cable technical parameters
Parameter Value / condition
Rated voltage 75 V
Nominal signal conductor area 0.5 mm²
Signal conductor construction 7 × 0.29 mm tinned copper
DC conductor resistance 42 Ω/km
Characteristic impedance 70 Ω at 10 MHz
Typical operating capacitance 85 nF/km
Operating temperature -20 to +70 °C

TEBAOFLEX® — Individual and overall screen configurations

Individual and overall screen configurations
Pairs × (signal + drain) × mm² Nominal OD (mm)
1 × (2 + 1) × 0.5 5.5
2 × (2 + 1) × 0.5 7.5
4 × (2 + 1) × 0.5 9.7
8 × (2 + 1) × 0.5 12.9
12 × (2 + 1) × 0.5 14.5
16 × (2 + 1) × 0.5 16.2
24 × (2 + 1) × 0.5 20.1

Count signal cores and screen connections separately

The representative four-pair build has eight insulated signal conductors and five screen-drain connections: one for each pair and one for the overall screen. Its typical cable capacitance over 100 m is about 8.5 nF per applicable circuit at 85 nF/km. Both checks help size the termination and review instrument loading.

Selection guide: A designation such as four pairs still means eight insulated signal cores; it does not include drain wires in that count. Keep foil screens and drain connections continuous according to the instrument bonding plan, with room to maintain pair identification at each termination.

Ordering & Quotation Checklist: Send the complete configuration, circuit requirements, length, quantity, installation duty and required test documents. Include the equipment drawing and the relevant environmental or movement conditions.

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for Individually and Overall Screened Instrumentation Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.

  • ISO 9001 Factory Direct
  • MOQ 50 m (Custom Builds)
  • 24h Engineering Reply
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    You may also like…

    Individually and Overall Screened Instrumentation CableGet A Quote