

UL 1180 PTFE Wire 200°C 300V, Silver-Plated Copper
UL 1180 wire is a 300 V, 200 °C single-conductor wire with extruded PTFE insulation over solid or stranded silver-plated copper, made from 30 AWG to 10 AWG for internal wiring of electronic components and general appliance wiring.
- Voltage rating300 V
- Temperature rating200 °C
- ConductorSilver-plated copper
- InsulationExtruded PTFE
- Sizes10 to 30 AWG
- Conductor buildSolid or stranded
- ColoursMultiple standard colours
- MarkingSurface printed, UL or CSA
UL 1180 High-Temperature Wire Identification
- Type: Industrial Cables
- Voltage rating: 300 V
- Temperature rating: 200 °C
- Conductor: Silver-plated copper
Continuous Thermal, Dielectric & AWG Ratings
- Insulation: Extruded PTFE
- Sizes: 10 to 30 AWG
- Conductor build: Solid or stranded
- Colours: Multiple standard colours
- Marking: Surface printed, UL or CSA
UL 1180 Plated Conductor & Fluoropolymer/Silicone Build
UL 1180 is a single-conductor wire with two layers: a solid or stranded silver-plated copper conductor and one extruded PTFE wall.
- Conductor: silver-plated copper; solid or 7 strands from 30 AWG to 18 AWG, 19 strands from 28 AWG to 12 AWG and 37 strands at 10 AWG. The plating protects the copper at 200 °C and keeps it easy to solder.
- Stranding choice: solid conductors hold their shape for fixed wiring to terminals; stranded conductors bend more easily for leads that are routed during assembly.
- Insulation: extruded PTFE, which gives the wire chemical, thermal and dielectric resistance at its 200 °C rating.
- Identification: surface printing as required by UL or CSA, in multiple standard insulation colours.
Thermal Endurance, Outgassing & Dielectric Stability
- Rating: 300 V and 200 °C, for internal wiring of electronic components and general appliance wiring.
- Insulation: Extruded PTFE for chemical, thermal and dielectric resistance.
- Conductor: Silver-plated copper, solid or stranded with 7, 19 or 37 strands depending on size.
- Sizes: 30 AWG to 10 AWG; solid conductors from 30 AWG to 18 AWG.
Chemical, Solvent, Flame & Cryogenic Resistance
- 200 °C rating: For internal wiring next to hot components in electronic and appliance assemblies.
- Extruded PTFE wall: Chemical, thermal and dielectric resistance in a smooth, even insulation.
- Silver-plated copper: Plating that protects the copper strands and keeps them easy to solder.
- Solid or stranded: Solid conductors for fixed wiring; 7-, 19- or 37-strand conductors for routed leads.
UL 758 AWM / CSA / Aerospace & Furnace Standards
- Wire style: UL 1180 AWM wire style, 200 °C and 300 V, with a CSA AWM I A/B 200 °C 300 V marking option on the insulation surface.
- Conductor: Silver-plated copper, solid from 30 AWG to 18 AWG and stranded from 30 AWG to 10 AWG.
- Voltage scope: 300 V for internal wiring of electronic components and general appliance wiring.
- Approvals: UL style, CSA and flame-test markings for your order are confirmed and quoted per order.
High-Temperature & Fluoropolymer Wire Guides

UL 1180 Thermal Zone & Internal Equipment Wiring
UL 1180 is the UL wire style for 300 V, 200 °C wire with PTFE insulation. TEBAOFLEX builds it with an extruded PTFE wall over silver-plated copper, solid or stranded, in sizes from 30 AWG to 10 AWG. The PTFE wall gives chemical, thermal and dielectric resistance, so the wire can run next to hot components inside equipment.
Choose UL 1180 for internal wiring of electronic components and for general appliance wiring where temperatures reach 200 °C and a 300 V rating is enough. Solid conductors suit fixed wiring to boards and terminals; 7-, 19- and 37-strand conductors suit leads that are routed and bent during assembly.
Furnaces, Ovens, Avionics & Cleanroom Assemblies
- UL 1180 is used for internal wiring of electronic components and for general appliance wiring exposed to temperature extremes and chemical stress: connections between circuit boards, terminals, sensors and switches inside instruments, control units and appliances that run hot. The fine solid sizes keep point-to-point wiring compact, and the stranded sizes up to 10 AWG carry supply leads.
- Within the TEBAOFLEX range, compareUL 1164for 300 V PTFE wire rated 150 °C,UL 1199where a 600 V, 200 °C PTFE rating is needed, andUL 1332for a 300 V, 200 °C lead wire with FEP insulation over tinned copper.
UL 1180 Thermal Rating & Stripping FAQ
What is UL 1180 wire?
UL 1180 is a UL wire style for 300 V, 200 °C wire. The TEBAOFLEX version uses extruded PTFE insulation over solid or stranded silver-plated copper, from 30 AWG to 10 AWG, for internal wiring of electronic components and general appliance wiring.
How is UL 1180 different from UL 1164 and UL 1199?
All three are PTFE wires with silver-plated copper conductors. UL 1180 is rated 300 V and 200 °C.UL 1164is also a 300 V wire but is rated 150 °C, andUL 1199keeps 200 °C and raises the rating to 600 V.
Should I choose a solid or a stranded conductor?
Solid conductors, available from 30 AWG to 18 AWG, suit fixed wiring that is formed once and soldered to boards or terminals. Choose 7- or 19-strand conductors for leads that are routed through equipment, bent during assembly or moved in service; 10 AWG is made with 37 strands.
What dimensions should I plan for?
The insulation wall, overall diameter and weight depend on the AWG size and stranding you choose. Tell us the size and stranding, and our engineers confirm these values on the datasheet issued with your quotation.
What should I send for a quotation?
Send the UL style, AWG size, solid or stranded conductor, insulation colour, put-up length, quantity and any UL or CSA marking requirement. Our engineers confirm the construction on the datasheet issued with your quotation.
Nominal values for UL 1180 constructions. The final construction is confirmed on the TEBAOFLEX datasheet issued with your quotation.
TEBAOFLEX® — UL 1180 (200 °C / 300 V PTFE) Representative AWG Dimensional & Silver-Plated Conductor Schedule
| AWG Size | Silver-Plated Stranding | Nom. Conductor Dia. (mm) | Nom. PTFE Wall (mm) | Nom. Overall Dia. (mm) |
|---|---|---|---|---|
| 28 AWG | 7/36 SPC | 0.38 | 0.33 | 1.07 |
| 26 AWG | 7/34 or 19/38 SPC | 0.48 | 0.33 | 1.17 |
| 24 AWG | 19/36 SPC | 0.61 | 0.33 | 1.30 |
| 22 AWG | 19/34 SPC | 0.76 | 0.33 | 1.45 |
| 20 AWG | 19/32 SPC | 0.97 | 0.33 | 1.65 |
| 18 AWG | 19/30 SPC | 1.19 | 0.33 | 1.88 |
| 16 AWG | 19/29 SPC | 1.45 | 0.35 | 2.18 |
| 14 AWG | 19/27 SPC | 1.83 | 0.35 | 2.56 |
| 12 AWG | 19/25 SPC | 2.31 | 0.35 | 3.05 |
TEBAOFLEX® — Electrical, thermal and material data
| Parameter | Value |
|---|---|
| Voltage rating | 300 V |
| Temperature rating | 200 °C |
| Conductor | Silver-plated copper |
| Conductor construction | Solid or stranded conductor options across AWG sizes |
| Insulation | Extruded PTFE |
| Protection | Extruded PTFE insulation for chemical, thermal and dielectric resistance |
| Colours | Multiple standard colours available |
| Identification | Surface printed as required by UL or CSA |
| Wire style | UL 1180 AWM 200 °C 300 V; CSA AWM I A/B 200 °C 300 V |
| Application | Internal wiring of electronic components and general appliance wiring |
Selection guide: Sizes run from 30 AWG to 10 AWG, solid or with 7, 19 or 37 strands. Before ordering, ask our engineers to confirm the insulation wall, overall diameter and weight for your AWG size and stranding, the current rating for your installation, the minimum bending radius, the flame-test marking and the put-up lengths you need.
Ordering & Quotation Checklist: Send the UL style, AWG size, solid or stranded conductor, insulation colour, put-up length, quantity and marking requirement, and we will confirm the construction and quote.
Request Quotation & Datasheet for This Cable
Need factory pricing, cross-section drawing or a full PDF datasheet for UL 1180 PTFE Wire 200°C 300V, Silver-Plated Copper? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.
- ISO 9001 Factory Direct
- MOQ 50 m (Custom Builds)
- 24h Engineering Reply



































