UL 1584 PTFE Wire 250°C 1000V for Motors and Heating Equipment

UL 1584 wire is a 1000 V single-conductor wire with PTFE fluoropolymer insulation, rated -65 °C to 250 °C and tested at 3000 V, for internal wiring of appliances, industrial machines, rotating machines and electrical heating equipment.

  • Voltage rating1000 V
  • Test voltage3000 V
  • Temperature range-65 °C to 250 °C
  • ConductorBare or plated copper
  • InsulationPTFE fluoropolymer
  • Wall thickness0.56 mm (.022 in)
  • Production rangeAWG 32 to AWG 10
  • Flame testsHorizontal flame, FT1, VW-1
Category:

UL 1584 High-Temperature Wire Identification

  • Type: Industrial Cables
  • Voltage rating: 1000 V
  • Test voltage: 3000 V
  • Temperature range: -65 °C to 250 °C

Continuous Thermal, Dielectric & AWG Ratings

  • Conductor: Bare or plated copper
  • Insulation: PTFE fluoropolymer
  • Wall thickness: 0.56 mm (.022 in
  • Production range: AWG 32 to AWG 10
  • Flame tests: Horizontal flame, FT1, VW-1

UL 1584 Plated Conductor & Fluoropolymer/Silicone Build

UL 1584 is a single-conductor wire with two layers: a copper conductor in one of four finishes and one PTFE fluoropolymer wall.

  • Conductor: stranded or solid copper, supplied bare, tinned, nickel-plated or silver-plated to suit the termination method and the operating temperature.
  • Insulation: PTFE fluoropolymer, 0.56 mm (.022 in) thick on every size, for 1000 V and -65 °C to 250 °C, with resistance to UV, chemicals and humidity.
  • Dielectric test: the insulated wire is rated for a 3000 V test voltage.
  • Options: special constructions are available on request.

Thermal Endurance, Outgassing & Dielectric Stability

  • Rating: 1000 V with a 3000 V test voltage, over a temperature range of -65 °C to 250 °C.
  • Insulation: PTFE fluoropolymer with high resistance to UV, chemicals and humidity, and good mechanical strength.
  • Conductor: Bare, tinned, nickel-plated or silver-plated copper, stranded or solid depending on the size.
  • Sizes: Production range AWG 32 to AWG 10, with the same 0.56 mm (.022 in) PTFE wall on every size.

Chemical, Solvent, Flame & Cryogenic Resistance

  • 1000 V rating: For circuits above 600 V, with a 3000 V test voltage.
  • -65 °C to 250 °C: One wire for cold starts and for runs beside heaters and machine windings.
  • Four conductor finishes: Bare, tinned, nickel-plated or silver-plated copper to suit the termination method and the duty.
  • PTFE fluoropolymer: Resists UV, chemicals and humidity, with good mechanical strength.

UL 758 AWM / CSA / Aerospace & Furnace Standards

  • Wire style: UL 1584 single-conductor wire, 1000 V and -65 °C to 250 °C, with UL 758 as the reference standard.
  • Flame tests: Horizontal flame, FT1 and VW-1 flame-test designations; the marking printed on your wire is agreed with the quotation.
  • Voltage scope: 1000 V with a 3000 V test voltage, for appliance, industrial machine, rotating machine and heating equipment wiring.
  • Approvals: UL style, CSA and flame-test markings for your order are confirmed and quoted per order.

High-Temperature & Fluoropolymer Wire Guides

Rail traction motor on a depot display stand with its connection leads brought out at the top of the frame; rotating machines like this need high-temperature wire for internal connections
Traction motors and other rotating machines run hot inside the frame, and their internal connections need wire rated for both heat and voltage, such as 250 °C, 1000 V UL 1584 PTFE wire. Photo: Hahifuheho, CC0 1.0, via Wikimedia Commons.

UL 1584 Thermal Zone & Internal Equipment Wiring

UL 1584 is the UL wire style for 1000 V single-conductor PTFE wire. TEBAOFLEX builds it with a 0.56 mm (.022 in) PTFE fluoropolymer wall over a bare, tinned, nickel-plated or silver-plated copper conductor, with a production range from AWG 32 to AWG 10 and a 3000 V test voltage.

Choose UL 1584 where a lead or internal wire must carry more than 600 V inside hot equipment: connections in motors and other rotating machines, heater circuits and machine wiring. The PTFE wall resists UV, chemicals and humidity, and the -65 °C lower limit covers equipment that is stored or started in the cold.

Furnaces, Ovens, Avionics & Cleanroom Assemblies

  • UL 1584 is used for internal cabling of appliances, industrial machines and rotating machines, and for the wiring of electrical heating equipment. Typical runs are winding leads from a motor or generator to its terminal box, connections inside heater and furnace control assemblies, and machine wiring that passes close to hot parts or meets chemical agents and moisture.
  • Within the TEBAOFLEX PTFE range, compareUL 1570for a 600 V, 250 °C wire with abrasion-resistant mineral-filled PTFE,UL 1659for a 600 V, 250 °C lead wire with nickel-plated copper, andUL 1199where a 200 °C, 600 V rating is enough. Choose UL 1584 when the circuit voltage is above 600 V.

UL 1584 Thermal Rating & Stripping FAQ

What is UL 1584 wire?

UL 1584 is a UL wire style for single-conductor PTFE wire rated 1000 V. The TEBAOFLEX version is rated -65 °C to 250 °C, tested at 3000 V and built from AWG 32 to AWG 10 with bare, tinned, nickel-plated or silver-plated copper, for appliances, industrial machines, rotating machines and heating equipment.

How is UL 1584 different from UL 1570 and UL 1659?

All three are 250 °C PTFE wires. UL 1584 is rated 1000 V and offers four conductor finishes.UL 1570is a 600 V wire with mineral-filled PTFE over nickel-plated copper for abrasion resistance, andUL 1659is a 600 V lead wire with plain PTFE over nickel-plated copper.

Which conductor finish should I choose?

Tell us the highest temperature at the wire, how it is terminated and the circuit voltage. Our engineers confirm which of the bare, tinned, nickel-plated or silver-plated copper conductors suits that duty and state its temperature rating on the datasheet issued with your quotation.

What should I send for a quotation?

Send the UL style, AWG size and conductor structure, conductor finish, insulation colour, put-up length, quantity and any UL, CSA or flame-test marking requirement. Our engineers confirm the construction on the datasheet issued with your quotation.

Nominal values for UL 1584 constructions. The final construction is confirmed on the TEBAOFLEX datasheet issued with your quotation.

TEBAOFLEX® — Electrical, thermal and material data

UL 1584 PTFE Wire 250°C 1000V for Motors and Heating Equipment Technical Specifications
Parameter Value
Voltage rating 1000 V
Test voltage 3000 V
Temperature range -65 °C to 250 °C
Conductor Bare, tinned, nickel-plated or silver-plated copper
Insulation PTFE fluoropolymer
Protection PTFE insulation with excellent UV, chemical and humidity resistance
Performance Excellent mechanical strength and environmental resistance
Options Special constructions available on request
Wire style UL 1584; UL 758
Flame tests Horizontal flame, FT1 and VW-1
Production range AWG 32 to AWG 10
Application Appliances, industrial machines, rotating machines and heating equipment

TEBAOFLEX® — Dimensions and weights, 22 to 30 AWG

UL 1584 PTFE Wire 250°C 1000V for Motors and Heating Equipment Technical Specifications
AWG Conductor structure Cond. dia. in / mm Wall thickness in / mm Final O.D. in / mm Weight lb/kft / kg/km
22 1 x 0.65 .026 / .65 .022 / .56 .070 / 1.77 5.5 / 8.1
24 7 x 0.20 .024 / .60 .022 / .56 .068 / 1.72 4.9 / 7.3
24 1 x 0.50 .020 / .50 .022 / .56 .064 / 1.62 4.4 / 6.6
26 7 x 0.16 .019 / .48 .022 / .56 .063 / 1.60 4.0 / 6.0
26 1 x 0.40 .016 / .40 .022 / .56 .060 / 1.52 3.6 / 5.4
28 7 x 0.12 .014 / .36 .022 / .56 .058 / 1.48 3.3 / 4.9
28 1 x 0.32 .013 / .32 .022 / .56 .057 / 1.44 3.1 / 4.6
30 7 x 0.10 .012 / .30 .022 / .56 .056 / 1.42 2.9 / 4.3
30 1 x .254 .010 / .254 .022 / .56 .054 / 1.37 2.7 / 4.0

Selection guide: Before ordering, ask our engineers to confirm the conductor structure, diameters and weight of the constructions not listed above (10 AWG to 22 AWG stranded, 20 AWG solid and 32 AWG), the conductor resistance, the temperature rating for the conductor finish you choose, the minimum bending radius, the current rating for your installation, the flame-test marking and the put-up lengths you need.

Ordering & Quotation Checklist: Send the UL style, AWG size and conductor finish, insulation colour, put-up length, quantity and marking requirement, and we will confirm the construction and quote.

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for UL 1584 PTFE Wire 250°C 1000V for Motors and Heating Equipment? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.

  • ISO 9001 Factory Direct
  • MOQ 50 m (Custom Builds)
  • 24h Engineering Reply
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    UL 1584 PTFE Wire 250°C 1000V for Motors and Heating EquipmentGet A Quote