EVVF-H & EVVF-L Flat PVC Elevator Traveling Cable, 300V & 600V
300 V and 600 V EVVF-H (with two 2.0 mm steel-wire reinforcing suspension members) and EVVF-L (without reinforcing wire) are Korean KS / Asian-standard flat PVC-insulated and PVC-sheathed elevator traveling cables engineered in multi-unit 30C to 60C (0.75 mm²) and composite power + twisted-pair signal configurations (28C to 50C) for passenger and freight lift hoistways.
- Model designations300 V / 600 V EVVF-L & EVVF-H
- Reinforcement optionEVVF-L (without wire) / EVVF-H (2 × Ø2.0 mm steel)
- Rated voltage300 V AC or 600 V AC
- Test voltage (1 min)1,000 V (300V) / 1,500 V (600V) / 500 V (pairs)
- Standard control cores0.75 mm² (30/0.18 mm, 25.6 Ω/km max at 20 °C)
- Composite power cores2.0 mm² (30/0.26 or 37/0.26 mm, 9.98 Ω/km max)
- Composite signal pairs0.50 mm² (20/0.18 or 30/0.18 mm, 39.0 Ω/km max)
- Core & unit range24C to 60C (6×10) & composite 28C to 50C
EVVF-H & EVVF-L Flat PVC Elevator Traveling Cable Profile
- Type: Elevator Cable
- Model designations: 300 V / 600 V EVVF-L & EVVF-H
- Reinforcement option: EVVF-L (without wire) / EVVF-H (2 × Ø2.0 mm steel
- Rated voltage: 300 V AC or 600 V AC
Test Voltage, 0.75 mm² Control Cores & Shielded Pair Options
- Test voltage (1 min): 1,000 V (300V) / 1,500 V (600V) / 500 V (pairs
- Standard control cores: 0.75 mm² (30/0.18 mm, 25.6 Ω/km max at 20 °C
- Composite power cores: 2.0 mm² (30/0.26 or 37/0.26 mm, 9.98 Ω/km max
- Composite signal pairs: 0.50 mm² (20/0.18 or 30/0.18 mm, 39.0 Ω/km max
- Core & unit range: 24C to 60C (6×10) & composite 28C to 50C
EVVF-L Unreinforced & EVVF-H Steel-Supported Flat PVC Build
Parallel sub-units of flexible PVC-insulated copper cores (plus optional 2 × Ø2.0 mm steel suspension wires in EVVF-H) encapsulated in a flat flexible PVC sheath.
- Conductor: Flexible stranded annealed copper wire: 0.75 mm² (30/0.18 mm, Ø1.1 mm), 2.0 mm² (30/0.26 or 37/0.26 mm, Ø1.8 mm), 0.50 mm² (20/0.18 or 30/0.18 mm, Ø0.90–0.93 mm
- Core insulation: Flexible PVC compound (0.5–0.8 mm nominal wall on control/power cores; 0.38–0.40 mm on 0.5 mm² pairs
- Core & unit assembly: Cores twisted into 6-, 8- or 10-core sub-units (or power cores + twisted signal pairs) and arranged parallel in a single flat plane
- Reinforcing wire (EVVF-H only): 2 × 2.0 mm diameter galvanized steel wire ropes embedded along the outer edges of the flat profile
- Outer sheath: Cold- and flex-resistant flat PVC compound (1.0 mm to 1.4 mm nominal wall thickness), black
Free-Hanging Hoistway Loop & Steel Suspension Wire Performance
- EVVF-L vs EVVF-H steel support: EVVF-L provides a lightweight unreinforced ribbon for short/medium travel heights; EVVF-H adds 2 × Ø2.0 mm steel support wires for high-rise tensile suspension.
- 300 V & 600 V insulation walls: 300 V EVVF uses a 0.5–0.6 mm PVC insulation wall (1,000 V test); 600 V EVVF uses a thicker 0.8 mm PVC insulation wall on power/control cores (1,500 V test).
- Sub-unit grouped flat geometry: 30-core (5×6), 40-core (5×8) and 60-core (6×10) cables twist 6, 8 or 10 cores into sub-bundles before flat extrusion to prevent corkscrewing in the hoistway loop.
- Composite power + control + pair: Hybrid 28C/35C, 36C/44C and 42C/50C constructions integrate 2.0 mm² power cores, 0.75 mm² control cores and 0.5 mm² communication pairs in one traveling cable.
Fine-Stranded 30/0.18 mm Copper & Cold-Flexible Flat Jacket
- 30/0.18 mm flexible copper: 0.75 mm² control cores use 30 strands of 0.18 mm annealed copper wire (1.1 mm conductor Ø, max. 25.6 Ω/km at 20 °C) for smooth loop bending.
- High insulation resistance: Minimum insulation resistance at 20 °C is ≥ 20 MΩ·km on 0.75 mm² control cores, ≥ 50 MΩ·km on 2.0 mm² power cores and ≥ 100 MΩ·km on 0.5 mm² signal pairs.
- Low-profile H × W ribbon: Flat cross-sections (such as 9.0 × 43.0 mm for 300V EVVF-L 30C or 10.5 × 58.0 mm for 600V EVVF-H 30C) maintain a tight natural loop radius in narrow hoistways.
- 500 m standard drum length: Supplied in 500 m standard factory drums or custom pre-cut hoistway drop lengths.
KS / JSC 300V & 600V Flat Elevator Traveling Cable Standards
- Elevator traveling cable standard: Manufactured to Korean KS / JSC flat elevator traveling cable specifications in 300 V and 600 V voltage grades.
- Conductor resistance @ 20 °C: 0.75 mm² (30/0.18 mm): ≤ 25.6 Ω/km; 2.0 mm² (30/0.26 or 37/0.26 mm): ≤ 9.98 Ω/km; 0.50 mm² pair (20/0.18 or 30/0.18 mm): ≤ 39.0 Ω/km.
- Dielectric & insulation resistance: 1,000 V / 1,500 V AC 1-minute dielectric test (500 V on 0.5 mm² pairs); min. insulation resistance 20 / 50 / 100 MΩ·km at 20 °C.
Elevator Traveling, Lift & Flat Control Cable Guides

EVVF-H & EVVF-L High-Rise & Mid-Rise Hoistway Routing
In Korean (KS) and Asian high-rise and mid-rise elevator installations, flat PVC traveling cables suspended beneath the elevator car are specified under the EVVF-L and EVVF-H system in 300 V and 600 V voltage classes. Complementing European harmonizedH05VVH6-F and H07VVH6-F flat elevator cables, EVVF traveling cables group flexible annealed copper cores (0.75 mm² stranded 30/0.18 mm) into circular sub-units (such as 5×6 for 30 cores, 5×8 for 40 cores, or 6×10 for 60 cores) laid side-by-side inside a cold- and flex-resistant flat PVC outer sheath.
The suffix distinguishes the suspension load path: EVVF-L is the unreinforced flat traveling cable for low- and medium-rise shafts, whereas EVVF-H embeds two 2.0 mm diameter galvanized steel reinforcing wires (2 × Ø2.0 mm) on the outer edges of the flat profile to carry the deadweight of long hoistway drops and high-speed elevator cars. In addition to uniform 0.75 mm² control cables, the 600 V EVVF-H / EVVF-L series includes composite constructions (28C, 36C and 42C of 0.75 mm² control cores + 3C or 6C of 2.0 mm² car lighting/door-operator power cores + 1P or 2P of 0.50 mm² intercom/CAN-bus twisted pairs).
Passenger & Freight Elevator Car Traveling Loops
- 300 V and 600 V EVVF-L and EVVF-H flat cables are installed as free-hanging traveling loops between the hoistway junction box and the moving elevator car on passenger elevators, hospital bed lifts, freight elevators, observation lifts and automated parking towers. They carry car-call buttons, floor indicators, safety-gear interlocks, door-operator power, car lighting/ventilation and intercom/serial communication lines.
- For crane festoon trolleys or outdoor hoist systems requiring rubber sheathing instead of indoor hoistway PVC, compare with ourFC-PNCT-F & 600V SK-2PNCT flat rubber festoon cables.
EVVF-H & EVVF-L Elevator Traveling Cable FAQ
What is the difference between EVVF-L and EVVF-H elevator cables?
EVVF-L ('L' = Light/unreinforced) is a flat PVC elevator traveling cable without steel supporting wires for shorter hoistway drops. EVVF-H ('H' = Heavy/reinforced) incorporates two 2.0 mm diameter steel reinforcing wires along the edges of the flat sheath to support the mechanical tension of longer suspension heights.
How are 30C, 40C and 60C EVVF cables structured internally?
Rather than laying 30 to 60 individual cores in a single ultra-wide ribbon, EVVF groups 0.75 mm² cores into circular sub-units—5 units of 6 cores for 30C (5×6), 5 units of 8 cores for 40C (5×8) and 6 units of 10 cores for 60C (6×10)—and lays those sub-units parallel under the flat PVC sheath.
What do the 35C, 44C and 50C composite 600V EVVF-H / EVVF-L designations mean?
In composite EVVF cables, the total core count sums the control cores, power cores and signal pair conductors: 35C = 28×0.75 mm² + 3×2.0 mm² + 2P×0.5 mm² (4 cores); 44C = 36×0.75 mm² + 6×2.0 mm² + 1P×0.5 mm² (2 cores); and 50C = 42×0.75 mm² + 6×2.0 mm² + 1P×0.5 mm² (2 cores).
How does EVVF compare with European H05VVH6-F and H07VVH6-F?
Both are flat PVC elevator traveling cables. H05VVH6-F (300/500 V) and H07VVH6-F (450/750 V) follow European EN 50214 / HD 359 S2 standards, whereas 300 V / 600 V EVVF-L and EVVF-H follow Korean KS / Asian elevator manufacturer standards with sub-unit (5×6, 5×8, 6×10) and composite 2.0 mm² + 0.75 mm² + 0.5 mm² layouts.
Engineering specifications and dimensional tables for 300 V and 600 V EVVF-L (unreinforced) and EVVF-H (steel-wire reinforced) flat PVC elevator traveling cables from 24C to 60C and composite power/signal constructions. Final hoistway drop height, suspension hanger clamps and reel lengths are confirmed on the TEBAOFLEX datasheet issued with your quotation.
TEBAOFLEX® — 300 V & 600 V EVVF-L (Unreinforced) & EVVF-H (Steel-Wire Reinforced) Flat PVC Elevator Traveling Cables — 0.75 mm² Series
| Model & Voltage | Cores (Unit Layout) × Size (mm²) | Conductor Stranding (No./mm) | Insul. / Sheath Wall (mm) | Reinforcing Steel Wire (No. × mm) | Approx. Overall H × W (mm) | Test Voltage (V) | Approx. Weight (kg/km) |
|---|---|---|---|---|---|---|---|
| 300V EVVF-L | 24C × 0.75 | 30/0.18 | 0.6 / 1.0 | None | 4.6 × 66.0 | 1,000 | 515 |
| 300V EVVF-L | 30C (5×6) × 0.75 | 30/0.18 | 0.5 / 1.3 | None | 9.0 × 43.0 | 1,000 | 610 |
| 300V EVVF-L | 40C (5×8) × 0.75 | 30/0.18 | 0.5 / 1.3 | None | 9.0 × 56.0 | 1,000 | 840 |
| 300V EVVF-L | 60C (6×10) × 0.75 | 30/0.18 | 0.5 / 1.4 | None | 9.2 × 73.0 | 1,500 | 1,145 |
| 300V EVVF-H | 30C (5×6) × 0.75 | 30/0.18 | 0.5 / 1.3 | 2 × 2.0 | 9.0 × 46.0 | 1,000 | 660 |
| 300V EVVF-H | 40C (5×8) × 0.75 | 30/0.18 | 0.5 / 1.3 | 2 × 2.0 | 9.0 × 61.0 | 1,000 | 940 |
| 300V EVVF-H | 60C (6×10) × 0.75 | 30/0.18 | 0.5 / 1.4 | 2 × 2.0 | 9.2 × 83.0 | 1,500 | 1,294 |
| 600V EVVF-L | 30C (5×6) × 0.75 | 30/0.18 | 0.8 / 1.3 | None | 10.5 × 53.0 | 1,500 | 780 |
| 600V EVVF-L | 40C (5×8) × 0.75 | 30/0.18 | 0.8 / 1.3 | None | 10.5 × 68.0 | 1,500 | 1,015 |
| 600V EVVF-H | 30C (5×6) × 0.75 | 30/0.18 | 0.8 / 1.3 | 2 × 2.0 | 10.5 × 58.0 | 1,500 | 885 |
| 600V EVVF-H | 40C (5×8) × 0.75 | 30/0.18 | 0.8 / 1.3 | 2 × 2.0 | 10.5 × 72.0 | 1,500 | 1,150 |
TEBAOFLEX® — 300 V & 600 V EVVF-L / EVVF-H Composite Power + Control + Twisted-Pair Elevator Traveling Cables
| Model & Voltage | Composite Core Breakdown | Conductor Stranding (No./mm) | Insul. Wall (mm) | Reinforcing Steel Wire (No. × mm) | Approx. Overall H × W (mm) | Test Voltage (V) | Approx. Weight (kg/km) |
|---|---|---|---|---|---|---|---|
| 300V EVVF-L (24C) | 20C×0.75 + 2P×0.5 | 30/0.18 & 20/0.18 | 0.60 / 0.38 | None | 5.8 × 62.5 | 1,000 / 500 | 600 |
| 600V EVVF-L (35C) | 28C×0.75 + 3C×2.0 + 2P×0.5 | 30/0.18, 30/0.26, 30/0.18 | 0.8 / 0.8 / 0.4 | None | 11.0 × 54.1 | 1,000 / 1,500 / 500 | 1,011 |
| 600V EVVF-H (35C) | 28C×0.75 + 3C×2.0 + 2P×0.5 | 30/0.18, 30/0.26, 30/0.18 | 0.8 / 0.8 / 0.4 | 2 × 2.0 | 11.0 × 61.1 | 1,000 / 1,500 / 500 | 1,294 |
| 600V EVVF-L (44C) | 36C×0.75 + 6C×2.0 + 1P×0.5 | 30/0.18, 37/0.26, 20/0.18 | 0.5 / 0.8 / 0.4 | None | 11.0 × 66.4 | 1,000 / 1,500 / 500 | 1,032 |
| 600V EVVF-H (44C) | 36C×0.75 + 6C×2.0 + 1P×0.5 | 30/0.18, 37/0.26, 20/0.18 | 0.5 / 0.8 / 0.4 | 2 × 2.0 | 11.0 × 73.4 | 1,000 / 1,500 / 500 | 1,351 |
| 600V EVVF-L (50C) | 42C×0.75 + 6C×2.0 + 1P×0.5 | 30/0.18, 30/0.26, 30/0.18 | 0.5 / 0.8 / 0.4 | None | 11.0 × 70.4 | 1,000 / 1,500 / 500 | 1,107 |
| 600V EVVF-H (50C) | 42C×0.75 + 6C×2.0 + 1P×0.5 | 30/0.18, 30/0.26, 30/0.18 | 0.5 / 0.8 / 0.4 | 2 × 2.0 | 11.0 × 77.4 | 1,000 / 1,500 / 500 | 1,351 |
Selection guide: Select EVVF-L (without reinforcing wire) for low- to mid-rise elevators with short suspension loops; select EVVF-H (with 2 × Ø2.0 mm steel-wire suspension members) for high-rise hoistways or heavy composite 35C/44C/50C configurations.
Ordering & Quotation Checklist: Send your required 300 V or 600 V EVVF-L / EVVF-H core configuration (e.g., 30C, 40C, 60C or composite 35C/44C/50C) and hoistway drop lengths for a factory quotation.
FC-PNCT & SK-2PNCT Flat & Round Rubber Crane Festoon Cable (0.6/1kV & 600V)
0.6/1 kV FC-PNCT / FC-PNCT-F & 600 V SK-2PNCT
BAULIFTKABEL B101 / B102 / B103 & Flugzeugheber-T Hoist / Trailing Cable
BAULIFTKABEL B101 / B102 / B103 | BAULIFT-T / BAULIFT-W | Flugzeugheber-T
VCVH6-F 300/500V Flat PVC & Screened Festoon / Elevator Traveling Cable
VCVH6-F (Screened) & H05VVH6-F / H07VVH6-F (Unscreened)
Request Quotation & Datasheet for This Cable
Need factory pricing, cross-section drawing or a full PDF datasheet for EVVF-H & EVVF-L Flat PVC Elevator Traveling Cable, 300V & 600V? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.
- ISO 9001 Factory Direct
- MOQ 50 m (Custom Builds)
- 24h Engineering Reply