Marine and Offshore Ethernet Cable

Marine and offshore Ethernet cable combines balanced data constructions with the specified SHF1, LSHF-FR or protective outer-jacket systems for shipboard networks. Selected SF/UTP conductor / insulation: Solid bare AWG24 / PE.

  • Selected SF/UTP conductor / insulationSolid bare AWG24 / PE, nominal insulated diameter 1.1 mm
  • Selected SF/UTP service temperature-20 to +60 °C
  • S/FTP LSHF and MUD range temperature-40 to +80 °C for the listed constructions
  • Fast-connect FRNC service / installation-25 to +70 °C / 0 to +50 °C
  • Fast-connect FRNC fixed / flexing bend3 × D / 7.5 × D
  • Fast-connect FRNC peak voltage125 V; not for mains-power applications
  • Fast-connect FRNC network reference10/100 Mbit/s; maximum 85 m link for the specified four-core build
  • BuildConductor

Marine and Offshore Ethernet Cable Shipboard & Offshore Identification

  • Type: Industrial Cables
  • Selected SF/UTP conductor / insulation: Solid bare AWG24 / PE, nominal insulated diameter 1.1 mm
  • Selected SF/UTP service temperature: -20 to +60 °C
  • S/FTP LSHF and MUD range temperature: -40 to +80 °C for the listed constructions

Marine Electrical, Temperature & Bend Ratings

  • Fast-connect FRNC service / installation: -25 to +70 °C / 0 to +50 °C
  • Fast-connect FRNC fixed / flexing bend: 3 × D / 7.5 × D
  • Fast-connect FRNC peak voltage: 125 V; not for mains-power applications
  • Fast-connect FRNC network reference: 10/100 Mbit/s; maximum 85 m link for the specified four-core build
  • Build: Conductor

Marine and Offshore Ethernet Cable Halogen-Free / Armored Architecture

The image and section represent the solid AWG24 four-pair SF/UTP single-jacket build. It has one common foil screen around the pair bundle, rather than four individual pair foils.

  • Selected SF/UTP build: Four pairs of solid bare copper AWG24, PE insulation with nominal 1.1 mm insulated diameter.
  • Selected screen / sheath: One overall foil plus copper braid; gray SHF1 / LSHF-FR sheath, nominal OD 6.6 mm.
  • S/FTP shipboard builds: Four individually screened pairs plus overall braid; foam-skin PE insulation and LSHF-FR jacket.
  • MUD versions: LSHF inner jacket and a separate MUD outer jacket.
  • Seawater version: AWG24/7, S/FTP, LSHF inner jacket, swellable water-blocking tape and black PUR outer jacket.
  • Fast-connect FRNC version: Tinned AWG22/7 four-core star quad, thermoplastic inner sheath, foil/braid screen and green FRNC outer.

Shipboard Fire Integrity & EMC Performance

  • Installation and connection: Plan bulkhead transits and cable entries with the vessel installation design.
  • Include both jackets when selecting the transit: The Cat.5e single-jacket S/FTP build is nominally 6.2 mm OD and the corresponding MUD outer system is 9.6 mm.
  • Fast-connect FRNC network reference: 10/100 Mbit/s; maximum 85 m link for the specified four-core build
  • Build: Conductor

Salt Fog, Mud, Oil & Low-Smoke Resistance

  • Selection point: Information to specify
  • Environmental zone: Shipboard interior, mud or seawater exposure
  • Screen geometry: SF/UTP or S/FTP and the selected connector
  • Installed route: Transit, gland range, bend space and restraint

IEC 60092 / NEK 606 / BS Marine Standards

  • Reference / performance: Applicable condition
  • IEC 61156 / ISO/IEC 11801: Balanced marine network-cable references for the corresponding construction.
  • SHF1: Specified marine sheath construction.
  • IEC 60332-3: Bunched-cable flame reference for the listed LSHF shipboard and MUD constructions.
  • CPR Dca: Specified single-jacket S/FTP builds and selected 6.6 mm solid SF/UTP build; class belongs to the exact declared version.

Marine & Offshore Cable Engineering Guides

Marine communications cable routing in its equipment environment
Equipment environment and supported cable routing for the stated application. Select the actual cable and connection for the installation duty.

Marine and Offshore Ethernet Cable Vessel, Platform & FPSO Routing

Marine and offshore Ethernet cable combines balanced data constructions with the specified SHF1, LSHF-FR or protective outer-jacket systems for shipboard networks. The range includes four-pair S/FTP builds, double-jacket MUD variants, a solid-copper SF/UTP build and a four-core fast-connect FRNC construction.

Choose the electrical construction and protective system together. The representative gray SF/UTP build uses solid bare AWG24 conductors, PE insulation and one overall foil-and-braid screen. Other marine builds use individual pair foils plus an overall braid. MUD and seawater versions add protective layers and have different finished diameters from their single-jacket counterparts.

Shipboard Systems & Offshore Zone Coverage

  • For shipboard Ethernet, marine automation, offshore communication, equipment networks and the specifically constructed mud-resistant or seawater-immersion routes.
  • Selection point: Information to specify
  • Environmental zone: Shipboard interior, mud or seawater exposure
  • Screen geometry: SF/UTP or S/FTP and the selected connector
  • Installed route: Transit, gland range, bend space and restraint

Installation and connection

Plan bulkhead transits and cable entries with the vessel installation design. The listed seawater build supports months of direct seawater exposure under its stated application; specify the actual exposure and entry system when ordering that version.

Marine and Offshore Ethernet Cable Marine & Offshore Technical FAQ

Why is 'Installation and connection' critical when specifying Marine and Offshore Ethernet Cable?

Plan bulkhead transits and cable entries with the vessel installation design. The listed seawater build supports months of direct seawater exposure under its stated application; specify the actual exposure and entry system when ordering that version.

How should engineers address 'include both jackets when selecting the transit' for Marine and Offshore Ethernet Cable?

The Cat.5e single-jacket S/FTP build is nominally 6.2 mm OD and the corresponding MUD outer system is 9.6 mm. The seawater version has an 8.3 mm LSHF inner jacket and an 11.3 mm completed PUR outer diameter. Use the completed cable size for entries and routing.

What core insulation, bedding, and shielding architecture is built into Marine and Offshore Ethernet Cable?

Selected SF/UTP build: Four pairs of solid bare copper AWG24, PE insulation with nominal 1.1 mm insulated diameter.; Selected screen / sheath: One overall foil plus copper braid; gray SHF1 / LSHF-FR sheath, nominal OD 6.6 mm.; S/FTP shipboard builds: Four individually screened pairs plus overall braid; foam-skin PE insulation and LSHF-FR jacket.; MUD versions: LSHF inner jacket and a separate MUD outer jacket.; Seawater version: AWG24/7, S/FTP, LSHF inner jacket, swellable water-blocking tape and black PUR outer jacket.

How do fixed versus flexed temperature and bending ratings compare on Marine and Offshore Ethernet Cable?

Selected SF/UTP conductor / insulation: Solid bare AWG24 / PE, nominal insulated diameter 1.1 mm; Selected SF/UTP service temperature: -20 to +60 °C; S/FTP LSHF and MUD range temperature: -40 to +80 °C for the listed constructions; Fast-connect FRNC service / installation: -25 to +70 °C / 0 to +50 °C; Fast-connect FRNC fixed / flexing bend: 3 × D / 7.5 × D

Nominal selection data for the listed constructions. D means the finished cable outside diameter. Match the complete configuration and test conditions to the ordered cable.

TEBAOFLEX® — Marine and Offshore Ethernet Cable technical parameters

Marine and Offshore Ethernet Cable technical parameters
Parameter Value / condition
Selected SF/UTP conductor / insulation Solid bare AWG24 / PE, nominal insulated diameter 1.1 mm
Selected SF/UTP service temperature -20 to +60 °C
S/FTP LSHF and MUD range temperature -40 to +80 °C for the listed constructions
Fast-connect FRNC service / installation -25 to +70 °C / 0 to +50 °C
Fast-connect FRNC fixed / flexing bend 3 × D / 7.5 × D
Fast-connect FRNC peak voltage 125 V; not for mains-power applications
Fast-connect FRNC network reference 10/100 Mbit/s; maximum 85 m link for the specified four-core build

TEBAOFLEX® — Single-jacket and MUD marine network options

Single-jacket and MUD marine network options
Build Conductor Nominal outer OD (mm)
Cat.5e S/FTP, LSHF AWG24/7 6.2
Cat.7 S/FTP, LSHF AWG23/7 6.6
Compact Cat.7 S/FTP, LSHF AWG24/7 6.2
Cat.7A S/FTP, LSHF AWG23 solid 7.8
Cat.5e S/FTP, LSHF + MUD AWG24/7 9.6
Cat.7 S/FTP, LSHF + MUD AWG23/7 10.1
Compact Cat.7 S/FTP, LSHF + MUD AWG23 solid 9.6
Cat.7A S/FTP, LSHF + MUD AWG23 solid 9.8
Selected SF/UTP, SHF1 / LSHF AWG24 solid 6.6
Seawater S/FTP, LSHF + water block + PUR AWG24/7 11.3
Four-core fast-connect FRNC AWG22/7 tinned 6.5

Include both jackets when selecting the transit

The Cat.5e single-jacket S/FTP build is nominally 6.2 mm OD and the corresponding MUD outer system is 9.6 mm. The seawater version has an 8.3 mm LSHF inner jacket and an 11.3 mm completed PUR outer diameter. Use the completed cable size for entries and routing.

Selection guide: Keep the protective outer system in the complete ordering description. A common marine application does not make the conductor format or screen layout interchangeable. Review network performance, screen contact, strain relief and the required shipboard route as one installation.

Ordering & Quotation Checklist: Send the complete configuration, circuit requirements, length, quantity, installation duty and required test documents. Include the equipment drawing and the relevant environmental or movement conditions.

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for Marine and Offshore Ethernet Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.

  • ISO 9001 Factory Direct
  • MOQ 50 m (Custom Builds)
  • 24h Engineering Reply
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    You may also like…