APL-Sheathed Three-Core XLPE Submarine Power Cable
Fixed power connections in ground or water, including selected offshore collection and submarine routes. Series voltage reference: Up to 72.5 kV; define actual U₀/U(Uₘ) Power cores: Three Insulation: XLPE Radial barrier: Individual Al/PE laminated sheaths Conductor /armor choice: Project-specific Cu/Al and selected armor design
- Series voltage referenceUp to 72.5 kV; define actual U₀/U(Uₘ)
- Power coresThree
- InsulationXLPE
- Radial barrierIndividual Al/PE laminated sheaths
- Conductor /armor choiceProject-specific Cu/Al and selected armor design
- Optical functionCommunication and specified temperature-monitoring interface
- Cu or Al conductorSelect actual cross-section, screen and terminations.
- Steel /Al /mixed armorChoose mechanical and installation characteristics for the route.
APL-Sheathed Three-Core XLPE Submarine Shipboard & Offshore Identification
- Type: Industrial Cables
- Series voltage reference: Up to 72.5 kV; define actual U₀/U(Uₘ
- Power cores: Three
- Insulation: XLPE
Marine Electrical, Temperature & Bend Ratings
- Radial barrier: Individual Al/PE laminated sheaths
- Conductor /armor choice: Project-specific Cu/Al and selected armor design
- Optical function: Communication and specified temperature-monitoring interface
- Cu or Al conductor: Select actual cross-section, screen and terminations.
- Steel /Al /mixed armor: Choose mechanical and installation characteristics for the route.
APL-Sheathed Three-Core XLPE Submarine Halogen-Free / Armored Architecture
- Conductors: Circular Cu/Al stranded compacted, or selected solid Al.
- Core system: Inner semiconductor, XLPE and outer semiconductor.
- Electrical screen: Aluminum or copper wires.
- APL phase sheath: Aluminum tape plus PE oversheath with semiconductive skin.
- Optical /assembly: Integrated FO unit, filler profiles and PP bedding.
- Armor /outer protection: Project-selected armor and PP outer protection.
Select the complete construction
The Al/PE laminated barrier belongs to each screened phase: aluminum tape and PE oversheath with a semiconductive skin. It is not one common extra foil around the entire three-core assembly. Armor may use steel, aluminum or mixed plastic-wire constructions according to the selected project design.
Shipboard Fire Integrity & EMC Performance
- Select the complete construction: The Al/PE laminated barrier belongs to each screened phase: aluminum tape and PE oversheath with a semiconductive skin.
- Route and equipment selection: Describe seabed, duct or trough sections and their thermal/mechanical conditions.
- Keep the APL barrier, electrical screen and armor separate: The wire screen carries the specified electrical-screen task; aluminum tape and bonded PE form the selected APL radial barrier; the external armor answers route and load requirements.
- Cu or Al conductor: Select actual cross-section, screen and terminations.
Salt Fog, Mud, Oil & Low-Smoke Resistance
- Installation & Routing: Fixed power connections in ground or water, including selected offshore collection and submarine routes.
- Termination & Entry Check: Use each value for the stated construction and operating condition. Nominal dimensions belong to the listed configuration; include the voltage, core schedule and installation duty when selecting a size.
- IEC 60502 /IEC 60840: Apply the relevant voltage/construction requirements and test schedule.
- DNV-ST-0359: System and interface scope where specified by the wind-power project.
IEC 60092 / NEK 606 / BS Marine Standards
- IEC 60502 /IEC 60840: Apply the relevant voltage/construction requirements and test schedule.
- DNV-ST-0359: System and interface scope where specified by the wind-power project.
- Applicable Standard: Include the exact construction, required standard edition and test acceptance conditions in the purchase specification. Coordinate cable tests with the selected voltage, materials, installation supports and termination system. For a moving or subsea route, include the complete mechanical and environmental load schedule.
- Conductor Specification: Class 2 / Class 5 copper conductor per IEC 60228 / ASTM
Marine & Offshore Cable Engineering Guides

APL-Sheathed Three-Core XLPE Submarine Vessel, Platform & FPSO Routing
This APL-sheathed three-core XLPE submarine power cable combines three screened power cores with integrated optical services, filler profiles, PP bedding and project-selected armor. Each phase has semiconductor layers, XLPE insulation, an aluminum or copper wire screen and an aluminum/polyethylene laminated sheath with a semiconductive PE surface. The series reference extends up to 72.5 kV; the actual U₀/U(Uₘ), conductor and accessory schedule are selected for the project.
Choose the radial water-barrier construction and the complete installed system together. APL is distinct from the metallic electrical screen and from an extruded lead sheath. Armor material and geometry are also selected for route and installation loads. The one-line series voltage reference does not establish a common outside diameter, current rating or dynamic fatigue performance for every possible cable.
Shipboard Systems & Offshore Zone Coverage
- Fixed power connections in ground or water, including selected offshore collection and submarine routes.
Route and equipment selection
Describe seabed, duct or trough sections and their thermal/mechanical conditions. Identify pulling, armor and support requirements at approaches and transitions. Use the integrated optical option for the specified communication or temperature-monitoring system with its own fiber/interface schedule.
Compare related cable duties
- 66 kV Static Offshore Wind Array Cable
- 66 kV Dynamic Offshore Wind Array Cable
- Wind Farm MV Collector Cable, Copper & Aluminum XLPE/PE
APL-Sheathed Three-Core XLPE Submarine Marine & Offshore Technical FAQ
Specify the acceptance scope
Include the exact construction, required standard edition and test acceptance conditions in the purchase specification. Coordinate cable tests with the selected voltage, materials, installation supports and termination system. For a moving or subsea route, include the complete mechanical and environmental load schedule.
How should engineers address 'select the complete construction' for APL-Sheathed Three-Core XLPE Submarine Power Cable?
The Al/PE laminated barrier belongs to each screened phase: aluminum tape and PE oversheath with a semiconductive skin. It is not one common extra foil around the entire three-core assembly. Armor may use steel, aluminum or mixed plastic-wire constructions according to the selected project design.
What is the engineering rule regarding 'route and equipment selection' on APL-Sheathed Three-Core XLPE Submarine Power Cable?
Describe seabed, duct or trough sections and their thermal/mechanical conditions. Identify pulling, armor and support requirements at approaches and transitions. Use the integrated optical option for the specified communication or temperature-monitoring system with its own fiber/interface schedule.
How does APL-Sheathed Three-Core XLPE Submarine Power Cable handle compare related cable duties in field installations?
66 kV Static Offshore Wind Array Cable 66 kV Dynamic Offshore Wind Array Cable Wind Farm MV Collector Cable, Copper & Aluminum XLPE/PE
How does the internal construction of APL-Sheathed Three-Core XLPE Submarine Power Cable protect against mechanical or EMI stress?
Conductors: Circular Cu/Al stranded compacted, or selected solid Al.; Core system: Inner semiconductor, XLPE and outer semiconductor.; Electrical screen: Aluminum or copper wires.; APL phase sheath: Aluminum tape plus PE oversheath with semiconductive skin.; Optical /assembly: Integrated FO unit, filler profiles and PP bedding.
Use each value for the stated construction and operating condition. Nominal dimensions belong to the listed configuration; include the voltage, core schedule and installation duty when selecting a size.
TEBAOFLEX® — APL-Sheathed Three-Core XLPE Submarine Power Cable Construction, Operating & Compliance Matrix
| Cable Element / Layer | Selected Construction | Operating Parameter / Condition | Normative Reference & Test Scope |
|---|---|---|---|
| Conductors | Circular Cu/Al stranded compacted, or selected solid Al. | Series voltage reference: Up to 72.5 kV; define actual U₀/U(Uₘ) | IEC 60502 /IEC 60840 — Apply the relevant voltage/construction requirements and test schedule. |
| Core system | Inner semiconductor, XLPE and outer semiconductor. | Power cores: Three | DNV-ST-0359 — System and interface scope where specified by the wind-power project. |
| Electrical screen | Aluminum or copper wires. | Insulation: XLPE | IEC 60502 /IEC 60840 — Apply the relevant voltage/construction requirements and test schedule. |
| APL phase sheath | Aluminum tape plus PE oversheath with semiconductive skin. | Radial barrier: Individual Al/PE laminated sheaths | DNV-ST-0359 — System and interface scope where specified by the wind-power project. |
| Optical /assembly | Integrated FO unit, filler profiles and PP bedding. | Conductor /armor choice: Project-specific Cu/Al and selected armor design | IEC 60502 /IEC 60840 — Apply the relevant voltage/construction requirements and test schedule. |
| Armor /outer protection | Project-selected armor and PP outer protection. | Optical function: Communication and specified temperature-monitoring interface | DNV-ST-0359 — System and interface scope where specified by the wind-power project. |
TEBAOFLEX® — APL-Sheathed Three-Core XLPE Submarine Power Cable technical parameters
| Parameter | Value / condition |
|---|---|
| Series voltage reference | Up to 72.5 kV; define actual U₀/U(Uₘ) |
| Power cores | Three |
| Insulation | XLPE |
| Radial barrier | Individual Al/PE laminated sheaths |
| Conductor /armor choice | Project-specific Cu/Al and selected armor design |
| Optical function | Communication and specified temperature-monitoring interface |
TEBAOFLEX® — APL-Sheathed Three-Core XLPE Submarine Power Cable configuration comparison
| Configuration | Selection scope |
|---|---|
| Cu or Al conductor | Select actual cross-section, screen and terminations. |
| Steel /Al /mixed armor | Choose mechanical and installation characteristics for the route. |
| Wet EPR array design | Separate radial-barrier and screen construction. |
Keep the APL barrier, electrical screen and armor separate
The wire screen carries the specified electrical-screen task; aluminum tape and bonded PE form the selected APL radial barrier; the external armor answers route and load requirements. State each layer and its interfaces explicitly instead of using one general waterproof-armored description.
Selection guide: The Al/PE laminated barrier belongs to each screened phase: aluminum tape and PE oversheath with a semiconductive skin. It is not one common extra foil around the entire three-core assembly. Armor may use steel, aluminum or mixed plastic-wire constructions according to the selected project design.
Ordering & Quotation Checklist: Send U₀/U(Uₘ), power/current, conductor material and area, route and water/thermal data, radial/longitudinal water requirements, optical services, armor and accessory interfaces.