Ceramic-Insulated Fire-Resistant Marine Instrumentation Cable
Fixed essential instrumentation, communication and control circuits on vessels and offshore platforms. Rated voltage: 150/250 (300) V Maximum conductor temperature: 90°C Maximum pulling stress per conductor: 50 N/mm² Representative 1-pair OD: 8.4 mm Representative mass /fixed bend radius: 92 kg/km /55 mm
- Rated voltage150/250 (300) V
- Maximum conductor temperature90°C
- Maximum pulling stress per conductor50 N/mm²
- Representative 1-pair OD8.4 mm
- Representative mass /fixed bend radius92 kg/km /55 mm
- Conductor resistance26 Ω/km
- Mutual capacitance /loop inductance120 nF/km /0.7 mH/km
- Ceramic HF S95White insulation, copper braid and orange SHF1.
Ceramic-Insulated Fire-Resistant Marine Shipboard & Offshore Identification
- Type: Industrial Cables
- Rated voltage: 150/250 (300) V
- Maximum conductor temperature: 90°C
- Maximum pulling stress per conductor: 50 N/mm²
Marine Electrical, Temperature & Bend Ratings
- Representative 1-pair OD: 8.4 mm
- Representative mass /fixed bend radius: 92 kg/km /55 mm
- Conductor resistance: 26 Ω/km
- Mutual capacitance /loop inductance: 120 nF/km /0.7 mH/km
- Ceramic HF S95: White insulation, copper braid and orange SHF1.
Ceramic-Insulated Fire-Resistant Marine Halogen-Free / Armored Architecture
- Conductors: Class 2 bare copper;0.75 mm².
- Insulation: White ceramic HF S95 compound.
- Core grouping: Pairs; two pairs in a quad.
- Armor /screen layer: Copper-wire braid.
- Sheath: Orange SHF1 halogen-free polyolefin.
Select the complete construction
HF S95 ceramic insulation directly surrounds each conductor. It is not drawn as fiberglass sleeving or an added mica/EPR layer. Two pairs in one quad contain four insulated copper cores, not four pairs.
Shipboard Fire Integrity & EMC Performance
- Select the complete construction: HF S95 ceramic insulation directly surrounds each conductor.
- Route and equipment selection: Define the circuit-integrity acceptance method together with supports, penetrations and terminations.
- Configuration and duty selection: Scroll the size table horizontally to compare all columns.
- Keep material, grouping and fire-test scope separate: A two-pair quad has four insulated conductors.
Salt Fog, Mud, Oil & Low-Smoke Resistance
- Installation & Routing: Fixed essential instrumentation, communication and control circuits on vessels and offshore platforms.
- Termination & Entry Check: Use each value for the stated construction and operating condition. Nominal dimensions belong to the listed configuration; include the voltage, core schedule and installation duty when selecting a size.
- IEC 60092-350/-360: Marine cable design and material references.
- IEC 60332-3-22 Cat.A; IEC 60332-1-2: Flame propagation.
IEC 60092 / NEK 606 / BS Marine Standards
- IEC 60092-350/-360: Marine cable design and material references.
- IEC 60332-3-22 Cat.A; IEC 60332-1-2: Flame propagation.
- IEC 60754-1/-2; IEC 61034-1/-2: Halogen, corrosivity and smoke references.
- IEC 60092-352: Choice and installation.
- IEC 60092-376; IEC 60228: Instrumentation construction and Class 2 conductor.
Marine & Offshore Cable Engineering Guides

Ceramic-Insulated Fire-Resistant Marine Vessel, Platform & FPSO Routing
This 150/250 V ceramic-insulated fire-resistant marine instrumentation cable uses Class 2 bare-copper conductors, white ceramic HF S95 insulation, a copper-wire braid and an orange SHF1 sheath. Numbered white cores form pairs, with two-pair quad options. The representative 1 × 2 × 0.75 mm² build contains two insulated signal cores. It serves fixed instrumentation, control and communications circuits on marine vessels and offshore platforms.
Select the ceramic insulation route by the complete circuit-integrity and electrical requirements. Ceramic insulation is a different construction from a mica-tape-plus-EPR barrier and must retain its own dimensions and termination preparation. The copper braid, orange jacket and pair/quad grouping also have distinct mechanical and connection roles. A material response in a fire test does not raise the normal continuous conductor-temperature rating.
Shipboard Systems & Offshore Zone Coverage
- Fixed essential instrumentation, communication and control circuits on vessels and offshore platforms.
Route and equipment selection
Define the circuit-integrity acceptance method together with supports, penetrations and terminations. Retain pair identity and identify the braid connection in the terminal schedule. The FE120-type designation should be accompanied by the actual test conditions rather than used as a standalone system fire rating.
Compare related cable duties
- 150/250 V BU and BFOU Fire-Resistant Instrumentation Cable
- 250 V Individually and Overall Screened Marine Instrumentation Cable
- BS 6883 & BS 7917 Offshore Instrumentation Cable, 150/250 V (UKOOA)
Ceramic-Insulated Fire-Resistant Marine Marine & Offshore Technical FAQ
Specify the acceptance scope
Include the exact construction, required standard edition and test acceptance conditions in the purchase specification. Coordinate cable tests with the selected voltage, materials, installation supports and termination system. For a moving or subsea route, include the complete mechanical and environmental load schedule.
Why is 'Select the complete construction' critical when specifying Ceramic-Insulated Fire-Resistant Marine Instrumentation Cable?
HF S95 ceramic insulation directly surrounds each conductor. It is not drawn as fiberglass sleeving or an added mica/EPR layer. Two pairs in one quad contain four insulated copper cores, not four pairs.
How should engineers address 'route and equipment selection' for Ceramic-Insulated Fire-Resistant Marine Instrumentation Cable?
Define the circuit-integrity acceptance method together with supports, penetrations and terminations. Retain pair identity and identify the braid connection in the terminal schedule. The FE120-type designation should be accompanied by the actual test conditions rather than used as a standalone system fire rating.
What is the engineering rule regarding 'compare related cable duties' on Ceramic-Insulated Fire-Resistant Marine Instrumentation Cable?
150/250 V BU and BFOU Fire-Resistant Instrumentation Cable 250 V Individually and Overall Screened Marine Instrumentation Cable BS 6883 & BS 7917 Offshore Instrumentation Cable, 150/250 V (UKOOA)
What core insulation, bedding, and shielding architecture is built into Ceramic-Insulated Fire-Resistant Marine Instrumentation Cable?
Conductors: Class 2 bare copper;0.75 mm².; Insulation: White ceramic HF S95 compound.; Core grouping: Pairs; two pairs in a quad.; Armor /screen layer: Copper-wire braid.; Sheath: Orange SHF1 halogen-free polyolefin.
Use each value for the stated construction and operating condition. Nominal dimensions belong to the listed configuration; include the voltage, core schedule and installation duty when selecting a size.
TEBAOFLEX® — Ceramic-Insulated Fire-Resistant Marine Instrumentation Cable technical parameters
| Parameter | Value / condition |
|---|---|
| Rated voltage | 150/250 (300) V |
| Maximum conductor temperature | 90°C |
| Maximum pulling stress per conductor | 50 N/mm² |
| Representative 1-pair OD | 8.4 mm |
| Representative mass /fixed bend radius | 92 kg/km /55 mm |
| Conductor resistance | 26 Ω/km |
| Mutual capacitance /loop inductance | 120 nF/km /0.7 mH/km |
TEBAOFLEX® — Ceramic-Insulated Fire-Resistant Marine Instrumentation Cable configuration comparison
| Configuration | Selection scope |
|---|---|
| Ceramic HF S95 | White insulation, copper braid and orange SHF1. |
| Mica/HF-EPR instrumentation | Separate layered fire-barrier design. |
| Normal XLPE instrumentation | Separate flame-retardant route without the ceramic fire construction. |
TEBAOFLEX® — Ceramic marine instrumentation cable nominal dimensions
| Configuration (mm²) | OD (mm) | Mass (kg/km) | Fixed bend radius (mm) |
|---|---|---|---|
| Ceramic-type 1 × 2 × 0.75 | 8.4 | 92 | 55 |
| Ceramic-type 2 × 2 × 0.75 quad | 9.6 | 127 | 60 |
| Ceramic-type 4 × 2 × 0.75 | 12.5 | 200 | 75 |
Configuration and duty selection
Scroll the size table horizontally to compare all columns.
Keep material, grouping and fire-test scope separate
A two-pair quad has four insulated conductors. The ceramic compound performs the insulation/fire-response task, while the copper braid supplies the specified metallic layer. Compare that construction with mica/EPR by its actual layers, loop data and installation requirements rather than by jacket color or an FE model suffix.
Selection guide: HF S95 ceramic insulation directly surrounds each conductor. It is not drawn as fiberglass sleeving or an added mica/EPR layer. Two pairs in one quad contain four insulated copper cores, not four pairs.
Ordering & Quotation Checklist: Send pair/quad count, conductor area, circuit load and length, fire-test acceptance method, installation route, braid connection, glands and inspection documents.
Request Quotation & Datasheet for This Cable
Need factory pricing, cross-section drawing or a full PDF datasheet for Ceramic-Insulated Fire-Resistant Marine Instrumentation Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.
- ISO 9001 Factory Direct
- MOQ 50 m (Custom Builds)
- 24h Engineering Reply