250 V Individually and Overall Screened Marine Instrumentation Cable
Fixed instrumentation, control and communications circuits on marine vessels and offshore platforms. Rated voltage: 250 V Maximum conductor temperature: 90°C Listed conductor area: 0.75 mm² Pair count range: 2, 4, 7, 10, 14, 19 and 24 Representative 2-pair OD: 13.6 mm
- Rated voltage250 V
- Maximum conductor temperature90°C
- Listed conductor area0.75 mm²
- Pair count range2, 4, 7, 10, 14, 19 and 24
- Representative 2-pair OD13.6 mm
- Representative 2-pair mass170 kg/km
- Representative 2-pair bend radius109 mm
- Conductor resistance26 Ω/km
250 V Individually and Overall Screened Shipboard & Offshore Identification
- Type: Industrial Cables
- Rated voltage: 250 V
- Maximum conductor temperature: 90°C
- Listed conductor area: 0.75 mm²
Marine Electrical, Temperature & Bend Ratings
- Pair count range: 2, 4, 7, 10, 14, 19 and 24
- Representative 2-pair OD: 13.6 mm
- Representative 2-pair mass: 170 kg/km
- Representative 2-pair bend radius: 109 mm
- Conductor resistance: 26 Ω/km
250 V Individually and Overall Screened Halogen-Free / Armored Architecture
- Conductors / pairs: Class 2 plain copper; white and blue XLPE cores twisted into pairs.
- Individual screens: Aluminum-plastic tape and tinned-copper drain for each pair.
- Overall screen: Aluminum-plastic tape,100% coverage, with a separate drain.
- Armor: Copper-wire braid.
- Outer sheath: Gray halogen-free SHF1 polyolefin.
Select the complete construction
Four layers have separate jobs: pair screens, overall screen, armor and outer sheath. The selected XLPE/SHF1 route differs from the EPR/SHF2 NEK instrumentation builds. Keep this distinction when comparing cable schedules.
Shipboard Fire Integrity & EMC Performance
- Select the complete construction: Four layers have separate jobs: pair screens, overall screen, armor and outer sheath.
- Route and equipment selection: Maintain the pair arrangement through the termination area and identify each screen and drain.
- Configuration and duty selection: Scroll the size table horizontally to compare all columns.
- Count signal cores, drains and armor separately: The 2-pair representative contains 2 × 2=4 insulated signal cores.
Salt Fog, Mud, Oil & Low-Smoke Resistance
- Installation & Routing: Fixed instrumentation, control and communications circuits on marine vessels and offshore platforms.
- Termination & Entry Check: Use each value for the stated construction and operating condition. Nominal dimensions belong to the listed configuration; include the voltage, core schedule and installation duty when selecting a size.
- IEC 60092-350/-376: Marine instrumentation design and tests.
- IEC 60228; IEC 60092-360: Conductor and insulation/sheath materials.
IEC 60092 / NEK 606 / BS Marine Standards
- IEC 60092-350/-376: Marine instrumentation design and tests.
- IEC 60228; IEC 60092-360: Conductor and insulation/sheath materials.
- IEC 60332-3-22 Cat.A; IEC 60332-1-2: Flame propagation references.
- IEC 60754-1/-2; IEC 61034-1/-2: Halogen, corrosivity and smoke references.
- IEC 60092-352: Choice and installation.
Marine & Offshore Cable Engineering Guides

250 V Individually and Overall Screened Vessel, Platform & FPSO Routing
This 250 V individually and overall screened marine instrumentation cable uses Class 2 bare-copper pairs, XLPE insulation and a gray SHF1 sheath. Each white/blue pair has its own aluminum-polyester screen and tinned-copper drain. A separate overall aluminum screen and drain surround the pair assembly, while an additional copper-wire braid supplies the specified armor layer.
Select this IS/OS construction for fixed marine instrumentation routes where pair isolation, common screening and mechanical protection are distinct requirements. The representative 2 × 2 × 0.75 mm² build contains four insulated signal conductors; neither the drain wires nor the armor are extra signal cores. Match pair count and cable diameter to terminal capacity, cable entries and the route before choosing an instrumentation cable only by its nominal voltage.
Shipboard Systems & Offshore Zone Coverage
- Fixed instrumentation, control and communications circuits on marine vessels and offshore platforms.
Route and equipment selection
Maintain the pair arrangement through the termination area and identify each screen and drain. The copper braid is a separate armor/protection layer, not an instruction to combine every drain and screen at an arbitrary point. Coordinate bonding, segregation and gland selection with the instrumentation system.
Compare related cable duties
- 150/250 V Overall Screened XLPE Marine Instrumentation Cable
- 150/250 V RU and RFOU Offshore Instrumentation Cable
- BS 6883 & BS 7917 Offshore Instrumentation Cable, 150/250 V (UKOOA)
250 V Individually and Overall Screened Marine & Offshore Technical FAQ
Specify the acceptance scope
Include the exact construction, required standard edition and test acceptance conditions in the purchase specification. Coordinate cable tests with the selected voltage, materials, installation supports and termination system. For a moving or subsea route, include the complete mechanical and environmental load schedule.
How should engineers address 'select the complete construction' for 250 V Individually and Overall Screened Marine Instrumentation Cable?
Four layers have separate jobs: pair screens, overall screen, armor and outer sheath. The selected XLPE/SHF1 route differs from the EPR/SHF2 NEK instrumentation builds. Keep this distinction when comparing cable schedules.
What is the engineering rule regarding 'route and equipment selection' on 250 V Individually and Overall Screened Marine Instrumentation Cable?
Maintain the pair arrangement through the termination area and identify each screen and drain. The copper braid is a separate armor/protection layer, not an instruction to combine every drain and screen at an arbitrary point. Coordinate bonding, segregation and gland selection with the instrumentation system.
How does 250 V Individually and Overall Screened Marine Instrumentation Cable handle compare related cable duties in field installations?
150/250 V Overall Screened XLPE Marine Instrumentation Cable 150/250 V RU and RFOU Offshore Instrumentation Cable BS 6883 & BS 7917 Offshore Instrumentation Cable, 150/250 V (UKOOA)
How does the internal construction of 250 V Individually and Overall Screened Marine Instrumentation Cable protect against mechanical or EMI stress?
Conductors / pairs: Class 2 plain copper; white and blue XLPE cores twisted into pairs.; Individual screens: Aluminum-plastic tape and tinned-copper drain for each pair.; Overall screen: Aluminum-plastic tape,100% coverage, with a separate drain.; Armor: Copper-wire braid.; Outer sheath: Gray halogen-free SHF1 polyolefin.
Use each value for the stated construction and operating condition. Nominal dimensions belong to the listed configuration; include the voltage, core schedule and installation duty when selecting a size.
TEBAOFLEX® — 250 V Individually and Overall Screened Marine Instrumentation Cable technical parameters
| Parameter | Value / condition |
|---|---|
| Rated voltage | 250 V |
| Maximum conductor temperature | 90°C |
| Listed conductor area | 0.75 mm² |
| Pair count range | 2, 4, 7, 10, 14, 19 and 24 |
| Representative 2-pair OD | 13.6 mm |
| Representative 2-pair mass | 170 kg/km |
| Representative 2-pair bend radius | 109 mm |
| Conductor resistance | 26 Ω/km |
TEBAOFLEX® — 250 V Individually and Overall Screened Marine Instrumentation Cable configuration comparison
| Configuration | Selection scope |
|---|---|
| Individual +overall screen +Cu braid | Representative HFX-ISOSA/Cu-type construction. |
| Overall-only XLPE pair | Use the related unarmored marine instrumentation page. |
| EPR offshore instrumentation | Compare RU/RFOU materials, screen metal and selected NEK edition separately. |
TEBAOFLEX® — IS/OS marine instrumentation cable dimensions
| Configuration (mm²) | Cable OD (mm) | Mass (kg/km) | Bend radius (mm) |
|---|---|---|---|
| HFX-ISOSA/Cu-type 2 × 2 × 0.75 | 13.6 | 170 | 109 |
| HFX-ISOSA/Cu-type 4 × 2 × 0.75 | 17.0 | 300 | 136 |
| HFX-ISOSA/Cu-type 7 × 2 × 0.75 | 20.1 | 420 | 161 |
| HFX-ISOSA/Cu-type 10 × 2 × 0.75 | 24.9 | 630 | 199 |
| HFX-ISOSA/Cu-type 14 × 2 × 0.75 | 27.1 | 760 | 217 |
| HFX-ISOSA/Cu-type 19 × 2 × 0.75 | 30.1 | 1000 | 241 |
| HFX-ISOSA/Cu-type 24 × 2 × 0.75 | 34.1 | 1190 | 273 |
Configuration and duty selection
Scroll the size table horizontally to compare all columns.
Count signal cores, drains and armor separately
The 2-pair representative contains 2 × 2=4 insulated signal cores. Each individual screen has its own drain and the overall screen has another; these do not change the signal-core count. Use a termination schedule that names the pair screens, common screen, drains and copper braid as separate elements.
Selection guide: Four layers have separate jobs: pair screens, overall screen, armor and outer sheath. The selected XLPE/SHF1 route differs from the EPR/SHF2 NEK instrumentation builds. Keep this distinction when comparing cable schedules.
Ordering & Quotation Checklist: Send pair count, conductor area, circuit voltage, loop length, IS/OS and drain termination, armor bonding, gland range, route and inspection requirements.