100 V LSZH Marine PROFIBUS Cable
Fixed fieldbus networks on marine vessels and offshore platforms. Voltage: 100 V Maximum conductor temperature: 80°C Installed temperature range: −35 to +80°C Installation temperature range: −15 to +50°C Impedance at 3–20 MHz: 150 ±15 Ω
- Voltage100 V
- Maximum conductor temperature80°C
- Installed temperature range−35 to +80°C
- Installation temperature range−15 to +50°C
- Impedance at 3–20 MHz150 ±15 Ω
- Impedance at 38.4 kHz /9.6 kHz185 ±18.5 Ω /250 ±25 Ω
- Maximum loop resistance 20°C110 Ω/km
- Minimum bendsSingle bend 10D; flexing 20D
100 V LSZH Marine PROFIBUS Cable Shipboard & Offshore Identification
- Type: Industrial Cables
- Voltage: 100 V
- Maximum conductor temperature: 80°C
- Installed temperature range: −35 to +80°C
Marine Electrical, Temperature & Bend Ratings
- Installation temperature range: −15 to +50°C
- Impedance at 3–20 MHz: 150 ±15 Ω
- Impedance at 38.4 kHz /9.6 kHz: 185 ±18.5 Ω /250 ±25 Ω
- Maximum loop resistance 20°C: 110 Ω/km
- Minimum bends: Single bend 10D; flexing 20D
100 V LSZH Marine PROFIBUS Cable Halogen-Free / Armored Architecture
- Signal cores: Two 0.35 mm² bare-copper conductors,7 wires each; red/green cellular HDPE.
- Fillers /wrap: Two blind nonconductive cores and nonwoven band.
- Screen: Laminated aluminum foil plus tinned-copper braid.
- Inner sheath: Halogen-free HM4; nominal 8 mm diameter.
- Outer sheath: Black cross-linked halogen-free compound; maximum 9.8 mm OD.
Select the complete construction
The two blind cores contain no conductor. The actual outside-to-inside metallic-layer order is black outer sheath, HM4 inner sheath, tinned-copper braid, aluminum foil and nonwoven wrapping around the signal-core assembly.
Shipboard Fire Integrity & EMC Performance
- Select the complete construction: The two blind cores contain no conductor.
- Route and equipment selection: Coordinate bus topology, connectors, terminations, route segregation and shield bonds.
- Check signal cores, final diameter and frequency together: The four-element round bundle contains only two electrical cores.
- Maximum loop resistance 20°C: 110 Ω/km
Salt Fog, Mud, Oil & Low-Smoke Resistance
- Installation & Routing: Fixed fieldbus networks on marine vessels and offshore platforms.
- Termination & Entry Check: Use each value for the stated construction and operating condition. Nominal dimensions belong to the listed configuration; include the voltage, core schedule and installation duty when selecting a size.
- M-02Y(ST)CHX: Selected marine bus construction designation.
- VDE 0207-24; IEC 60092-359: HM4 inner and cross-linked outer-sheath references.
IEC 60092 / NEK 606 / BS Marine Standards
- M-02Y(ST)CHX: Selected marine bus construction designation.
- VDE 0207-24; IEC 60092-359: HM4 inner and cross-linked outer-sheath references.
- IEC 60332-3-24 Cat.C: Flame propagation.
- IEC 60754-2; IEC 61034: Corrosivity and smoke.
- DIN VDE 0472-805 test B; VG 95218-2: Ozone and selected chemical-resistance test references.
Marine & Offshore Cable Engineering Guides

100 V LSZH Marine PROFIBUS Cable Vessel, Platform & FPSO Routing
This 100 V LSZH marine PROFIBUS cable uses two red/green cellular-HDPE signal cores and two nonconductive blind fillers to form the round assembly. Each signal conductor contains seven bare-copper wires with a nominal 0.35 mm² section. Nonwoven wrapping, laminated aluminum foil, a tinned-copper braid, an HM4 inner sheath and a black cross-linked halogen-free outer sheath complete the fixed marine bus construction.
Count electrical cores separately from fillers before choosing the connector and cable entry. The specified characteristic impedance depends on frequency, while the two sheath diameters serve different installation checks. This marine fixed-bus build is distinct from a generic industrial PROFIBUS cable, a PROFIBUS/power hybrid and a marine Ethernet cable. The 20D flexing bend reference does not establish a continuous cable-carrier cycle-life rating.
Shipboard Systems & Offshore Zone Coverage
- Fixed fieldbus networks on marine vessels and offshore platforms.
Route and equipment selection
Coordinate bus topology, connectors, terminations, route segregation and shield bonds. Check the installed attenuation budget at the actual signaling frequency and include connector/termination contributions. Select continuously moving or power-hybrid arrangements as separate cable designs.
Compare related cable duties
- PROFIBUS DP & PA Fieldbus Cable: 150 Ω Type A & 100 Ω Process Bus Cable
- Marine and Offshore Ethernet Cable
- PROFIBUS Power Hybrid Drag Chain Cable
100 V LSZH Marine PROFIBUS Cable Marine & Offshore Technical FAQ
Specify the acceptance scope
Include the exact construction, required standard edition and test acceptance conditions in the purchase specification. Coordinate cable tests with the selected voltage, materials, installation supports and termination system. For a moving or subsea route, include the complete mechanical and environmental load schedule.
How does 100 V LSZH Marine PROFIBUS Cable handle select the complete construction in field installations?
The two blind cores contain no conductor. The actual outside-to-inside metallic-layer order is black outer sheath, HM4 inner sheath, tinned-copper braid, aluminum foil and nonwoven wrapping around the signal-core assembly.
Why is 'Route and equipment selection' critical when specifying 100 V LSZH Marine PROFIBUS Cable?
Coordinate bus topology, connectors, terminations, route segregation and shield bonds. Check the installed attenuation budget at the actual signaling frequency and include connector/termination contributions. Select continuously moving or power-hybrid arrangements as separate cable designs.
How should engineers address 'compare related cable duties' for 100 V LSZH Marine PROFIBUS Cable?
PROFIBUS DP & PA Fieldbus Cable: 150 Ω Type A & 100 Ω Process Bus Cable Marine and Offshore Ethernet Cable PROFIBUS Power Hybrid Drag Chain Cable
How are the cores and protective layers arranged inside 100 V LSZH Marine PROFIBUS Cable?
Signal cores: Two 0.35 mm² bare-copper conductors,7 wires each; red/green cellular HDPE.; Fillers /wrap: Two blind nonconductive cores and nonwoven band.; Screen: Laminated aluminum foil plus tinned-copper braid.; Inner sheath: Halogen-free HM4; nominal 8 mm diameter.; Outer sheath: Black cross-linked halogen-free compound; maximum 9.8 mm OD.
Use each value for the stated construction and operating condition. Nominal dimensions belong to the listed configuration; include the voltage, core schedule and installation duty when selecting a size.
TEBAOFLEX® — 100 V LSZH Marine PROFIBUS Cable Construction, Operating & Compliance Matrix
| Cable Element / Layer | Selected Construction | Operating Parameter / Condition | Normative Reference & Test Scope |
|---|---|---|---|
| Signal cores | Two 0.35 mm² bare-copper conductors,7 wires each; red/green cellular HDPE. | Voltage: 100 V | M-02Y(ST)CHX — Selected marine bus construction designation. |
| Fillers /wrap | Two blind nonconductive cores and nonwoven band. | Maximum conductor temperature: 80°C | VDE 0207-24; IEC 60092-359 — HM4 inner and cross-linked outer-sheath references. |
| Screen | Laminated aluminum foil plus tinned-copper braid. | Installed temperature range: −35 to +80°C | IEC 60332-3-24 Cat.C — Flame propagation. |
| Inner sheath | Halogen-free HM4; nominal 8 mm diameter. | Installation temperature range: −15 to +50°C | IEC 60754-2; IEC 61034 — Corrosivity and smoke. |
| Outer sheath | Black cross-linked halogen-free compound; maximum 9.8 mm OD. | Impedance at 3–20 MHz: 150 ±15 Ω | DIN VDE 0472-805 test B; VG 95218-2 — Ozone and selected chemical-resistance test references. |
TEBAOFLEX® — 100 V LSZH Marine PROFIBUS Cable technical parameters
| Parameter | Value / condition |
|---|---|
| Voltage | 100 V |
| Maximum conductor temperature | 80°C |
| Installed temperature range | −35 to +80°C |
| Installation temperature range | −15 to +50°C |
| Impedance at 3–20 MHz | 150 ±15 Ω |
| Impedance at 38.4 kHz /9.6 kHz | 185 ±18.5 Ω /250 ±25 Ω |
| Maximum loop resistance 20°C | 110 Ω/km |
| Minimum bends | Single bend 10D; flexing 20D |
| Maximum installation tensile load | 100 N |
| Nominal mass | 110 kg/km |
TEBAOFLEX® — 100 V LSZH Marine PROFIBUS Cable configuration comparison
| Configuration | Selection scope |
|---|---|
| Marine PROFIBUS | Two signal cores plus two blind fillers; dual halogen-free sheaths. |
| Generic PROFIBUS DP/PA | Compare its actual transmission, sheath and installation schedule. |
| Marine Ethernet | Different protocol and core arrangement. |
TEBAOFLEX® — Marine PROFIBUS transmission attenuation references
| Frequency | Maximum attenuation (dB/km) |
|---|---|
| 16 MHz | 45 |
| 4 MHz | 22 |
| 38.4 kHz | 5 |
| 9.6 kHz | 3 |
Check signal cores, final diameter and frequency together
The four-element round bundle contains only two electrical cores. Use the final 9.8 mm maximum OD for the outer entry, and the 8 mm inner-sheath diameter only where the termination system uses that layer. Keep impedance and attenuation tied to frequency when checking the bus route; do not read the Ω symbol as a power unit.
Selection guide: The two blind cores contain no conductor. The actual outside-to-inside metallic-layer order is black outer sheath, HM4 inner sheath, tinned-copper braid, aluminum foil and nonwoven wrapping around the signal-core assembly.
Ordering & Quotation Checklist: Send bus protocol and rate, route length, temperature, connector/termination system, shield bonds, cable-entry dimensions, installed attenuation budget and quantity.