PROFIBUS Power Hybrid Drag Chain Cable

PROFIBUS power hybrid drag chain cable combines one separately screened red/green data pair with power cores for moving industrial equipment. Data characteristic impedance: 150 ±15 Ω Maximum mutual capacitance: 30 nF/km at 800 Hz PUR builds: peak operating voltage: 100 V; not for mains-power applications PUR builds: voltage test: 600 V core/core.

  • Data characteristic impedance150 ±15 Ω
  • Maximum mutual capacitance30 nF/km at 800 Hz
  • PUR builds: peak operating voltage100 V; not for mains-power applications
  • PUR builds: voltage test600 V core/core; 600 V core/screen also listed for the four-power-core build
  • Three-power-core PUR temperatureFixed -40 to +80 °C; flexing -5 to +50 °C
  • Three-power-core PUR flexing bend14.5 × D
  • Four-power-core PUR temperatureFixed -40 to +70 °C; flexing -30 to +60 °C
  • Four-power-core PUR flexing bend15 × D

PROFIBUS Power Hybrid Drag Chain Cable Signal & Bus Architecture

  • Type: Industrial Cables
  • Data characteristic impedance: 150 ±15 Ω
  • Maximum mutual capacitance: 30 nF/km at 800 Hz
  • PUR builds: peak operating voltage: 100 V; not for mains-power applications

Impedance, Attenuation & Operating Limits

  • PUR builds: voltage test: 600 V core/core; 600 V core/screen also listed for the four-power-core build
  • Three-power-core PUR temperature: Fixed -40 to +80 °C; flexing -5 to +50 °C
  • Three-power-core PUR flexing bend: 14.5 × D
  • Four-power-core PUR temperature: Fixed -40 to +70 °C; flexing -30 to +60 °C
  • Four-power-core PUR flexing bend: 15 × D

PROFIBUS Power Hybrid Drag Chain Cable Pair Twist, Foil & Braid Construction

The image and section represent the five-insulated-core PUR build: two data cores inside the pair screen and three power cores outside it. The four-power-core alternatives have six insulated cores in total.

  • Selected data pair: Red/green fine-wire bare-copper pair; diameter designation 1 × 2 × 0.64 mm.
  • Selected data conductor detail: 19 × approximately 0.127 mm wires.
  • Selected power cores: 3 × 1.0 mm² bare copper: black, blue and green-yellow; approximately 56 × 0.15 mm wires.
  • Insulation: PE in the selected PUR construction.
  • Data-pair screen: Foil plus tinned-copper braid around the data pair; no overall braid around the power cores.
  • Assembly / sheath: Nonwoven wrapping and violet PUR.
  • Four-power-core alternatives: PUR or PVC outer sheath; 4 × 1.5 mm² black numbered power cores.

Signal Integrity, Crosstalk & Noise Rejection

  • Installation and connection: Keep pair-screen termination and protective-conductor termination separately identifiable.
  • Check the selected hybrid cable against the chain radius: The nominal 10.1 mm three-power-core PUR cable needs a 146.45 mm radius at the listed 14.5 × D flexing condition.
  • Four-power-core PUR temperature: Fixed -40 to +70 °C; flexing -30 to +60 °C
  • Four-power-core PUR flexing bend: 15 × D

Process Plant, Moisture, UV & Chemical Protection

  • Selection point: Information to specify
  • Supply circuit: Function, voltage and conductor allocation
  • Chain route: Travel, actual radius and operating temperature
  • Bus interface: 150 Ω pair, topology, connector and screen contact

EN 50288 / PAS 5308 / Fieldbus Protocol Standards

  • Reference / performance: Applicable condition
  • DIN 19245 / EN 50170: PROFIBUS-DP application references; also listed for PROFIBUS-FMS and FIP duty.
  • IEC 60332-1-2: Flame-retardance reference for the PUR constructions.
  • Halogen-free PUR construction: Applicable PUR sheath construction.
  • UL/CSA CMG / CL3: Four-power-core PVC build only.

Instrumentation & Industrial Bus Guides

Industrial automation control wiring in its equipment environment
Equipment environment and supported cable routing for the stated application. Select the actual cable and connection for the installation duty.

PROFIBUS Power Hybrid Drag Chain Cable Process Control & Telemetry Topology

PROFIBUS power hybrid drag chain cable combines one separately screened red/green data pair with power cores for moving industrial equipment. The selected PUR construction has three 1.0 mm² power cores, a violet outer sheath and a 150 Ω balanced data pair, with four-power-core alternatives available as separate builds.

The representative data-pair screen encloses the red and green data conductors only. Three power cores—black, blue and green-yellow—sit outside that pair screen in the common cable assembly. Specify the control-supply function and the applicable operating voltage along with the bus connection; the presence of power cores does not establish a mains-feeder rating.

DCS, PLC, Fieldbus & Sensor Network Routes

  • For PROFIBUS-DP, PROFIBUS-FMS and FIP connections on moving machinery, decentralized equipment and drag-chain installations requiring the selected hybrid interface.
  • Selection point: Information to specify
  • Supply circuit: Function, voltage and conductor allocation
  • Chain route: Travel, actual radius and operating temperature
  • Bus interface: 150 Ω pair, topology, connector and screen contact

Installation and connection

Keep pair-screen termination and protective-conductor termination separately identifiable. Provide strain relief for the complete cable and leave the required bending space at chain transitions.

PROFIBUS Power Hybrid Drag Chain Cable Impedance, Grounding & Bus FAQ

How should engineers address 'installation and connection' for PROFIBUS Power Hybrid Drag Chain Cable?

Keep pair-screen termination and protective-conductor termination separately identifiable. Provide strain relief for the complete cable and leave the required bending space at chain transitions.

What is the engineering rule regarding 'check the selected hybrid cable against the chain radius' on PROFIBUS Power Hybrid Drag Chain Cable?

The nominal 10.1 mm three-power-core PUR cable needs a 146.45 mm radius at the listed 14.5 × D flexing condition. The 11.3 mm four-power-core variants need 169.5 mm at 15 × D. Verify the actual finished diameter and the full motion profile before selecting the chain.

What layer-by-layer materials and screening options define PROFIBUS Power Hybrid Drag Chain Cable?

Selected data pair: Red/green fine-wire bare-copper pair; diameter designation 1 × 2 × 0.64 mm.; Selected data conductor detail: 19 × approximately 0.127 mm wires.; Selected power cores: 3 × 1.0 mm² bare copper: black, blue and green-yellow; approximately 56 × 0.15 mm wires.; Insulation: PE in the selected PUR construction.; Data-pair screen: Foil plus tinned-copper braid around the data pair; no overall braid around the power cores.

What are the rated voltage, temperature limits, and minimum bend radii for PROFIBUS Power Hybrid Drag Chain Cable?

Data characteristic impedance: 150 ±15 Ω; Maximum mutual capacitance: 30 nF/km at 800 Hz; PUR builds: peak operating voltage: 100 V; not for mains-power applications; PUR builds: voltage test: 600 V core/core; 600 V core/screen also listed for the four-power-core build; Three-power-core PUR temperature: Fixed -40 to +80 °C; flexing -5 to +50 °C

Nominal selection data for the listed constructions. D means the finished cable outside diameter. Match the complete configuration and test conditions to the ordered cable.

TEBAOFLEX® — PROFIBUS Power Hybrid Drag Chain Cable technical parameters

PROFIBUS Power Hybrid Drag Chain Cable technical parameters
Parameter Value / condition
Data characteristic impedance 150 ±15 Ω
Maximum mutual capacitance 30 nF/km at 800 Hz
PUR builds: peak operating voltage 100 V; not for mains-power applications
PUR builds: voltage test 600 V core/core; 600 V core/screen also listed for the four-power-core build
Three-power-core PUR temperature Fixed -40 to +80 °C; flexing -5 to +50 °C
Three-power-core PUR flexing bend 14.5 × D
Four-power-core PUR temperature Fixed -40 to +70 °C; flexing -30 to +60 °C
Four-power-core PUR flexing bend 15 × D
Four-power-core PVC peak / test 600 V peak, not for power applications; 2,000 V core/core and core/screen test
Four-power-core PVC temperature / bends -5 to +80 °C; 5 × D fixed and 15 × D flexing

TEBAOFLEX® — PROFIBUS hybrid construction options

PROFIBUS hybrid construction options
Build Data + power designation Nominal OD (mm) Copper index (kg/km) Nominal weight (kg/km)
Three-power-core PUR 1 × 2 × 0.64 Ø + 3 × 1.0 mm² 10.1 59 125
Four-power-core PUR 1 × 2 × 0.64 Ø + 4 × 1.5 mm² 11.3 89 148
Four-power-core PVC 1 × 2 × 0.64 Ø + 4 × 1.5 mm² 11.3 89 155

Check the selected hybrid cable against the chain radius

The nominal 10.1 mm three-power-core PUR cable needs a 146.45 mm radius at the listed 14.5 × D flexing condition. The 11.3 mm four-power-core variants need 169.5 mm at 15 × D. Verify the actual finished diameter and the full motion profile before selecting the chain.

Selection guide: The data-conductor designation uses a 0.64 mm diameter reference, while the power cores are specified in square millimetres. Retain those units when preparing a request. Select the complete variant before applying its movement, voltage, flame and marking requirements.

Ordering & Quotation Checklist: Send the complete configuration, circuit requirements, length, quantity, installation duty and required test documents. Include the equipment drawing and the relevant environmental or movement conditions.

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for PROFIBUS Power Hybrid Drag Chain Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.

  • ISO 9001 Factory Direct
  • MOQ 50 m (Custom Builds)
  • 24h Engineering Reply
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    You may also like…

    PROFIBUS Power Hybrid Drag Chain CableGet A Quote