150/250 V BU and BFOU Fire-Resistant Instrumentation Cable
Fixed fire-alarm, emergency shutdown and other essential instrumentation loops with specified fire-resistant cable requirements. Rated voltage: 150/250 V Representative configuration: BFOU(i)2 × 2 × 0.75 mm² Representative OD /mass: 14.6 mm /405 kg/km Resistance at 20°C: 26.3 Ω/km Mutual capacitance: 85 nF/km
- Rated voltage150/250 V
- Representative configurationBFOU(i)2 × 2 × 0.75 mm²
- Representative OD /mass14.6 mm /405 kg/km
- Resistance at 20°C26.3 Ω/km
- Mutual capacitance85 nF/km
- Inductance at 1 kHz0.731 mH/km
- Maximum L/R at 1 kHz20 µH/Ω
- BU(i) /BU(c)Unarmored fire-resistant instrumentation, selected screen layout.
150/250 V BU and BFOU Fire-Resistant Shipboard & Offshore Identification
- Type: Industrial Cables
- Rated voltage: 150/250 V
- Representative configuration: BFOU(i)2 × 2 × 0.75 mm²
- Representative OD /mass: 14.6 mm /405 kg/km
Marine Electrical, Temperature & Bend Ratings
- Resistance at 20°C: 26.3 Ω/km
- Mutual capacitance: 85 nF/km
- Inductance at 1 kHz: 0.731 mH/km
- Maximum L/R at 1 kHz: 20 µH/Ω
- BU(i) /BU(c): Unarmored fire-resistant instrumentation, selected screen layout.
150/250 V BU and BFOU Fire-Resistant Halogen-Free / Armored Architecture
- Conductors: Class 2 tinned copper.
- Fire barrier /insulation: Mica tape(s) plus HF-EPR on each conductor.
- Selected screen: Copper/polyester individual pair screens with drains.
- BFOU covering /armor: Halogen-free inner covering plus tinned-copper braid.
- Sheath: SHF2 or specifically selected SHF MUD.
Select the complete construction
The representative BFOU(i) build explicitly includes mica below HF-EPR on each conductor and individual copper/polyester pair screens. Overall-screened(c) variants retain their own complete construction and test schedule rather than being inferred by deleting layers from the(i) drawing.
Shipboard Fire Integrity & EMC Performance
- Select the complete construction: The representative BFOU(i) build explicitly includes mica below HF-EPR on each conductor and individual copper/polyester pair screens.
- Route and equipment selection: Review the complete installed loop, including connections, supports, penetrations and segregation.
- Configuration and duty selection: Scroll the size table horizontally to compare all columns.
- Compare both circuit integrity and signal-loop loading: A fire-resistant cable still has conductor resistance, capacitance and inductance that belong in the instrumentation design.
Salt Fog, Mud, Oil & Low-Smoke Resistance
- Installation & Routing: Fixed fire-alarm, emergency shutdown and other essential instrumentation loops with specified fire-resistant cable requirements.
- Termination & Entry Check: Use each value for the stated construction and operating condition. Nominal dimensions belong to the listed configuration; include the voltage, core schedule and installation duty when selecting a size.
- NEK 606 IIIed.2004: Fire-resistant instrumentation design-series reference.
- IEC 60092-350/-351/-352/-376: Marine design, insulation and installation.
IEC 60092 / NEK 606 / BS Marine Standards
- NEK 606 IIIed.2004: Fire-resistant instrumentation design-series reference.
- IEC 60092-350/-351/-352/-376: Marine design, insulation and installation.
- IEC 60331-21: Cable fire-resistance reference; specify full acceptance conditions.
- IEC 60332-1-2; IEC 60332-3-22: Flame propagation.
- IEC 60754-1; IEC 61034-2: Halogen and smoke references.
Marine & Offshore Cable Engineering Guides

150/250 V BU and BFOU Fire-Resistant Vessel, Platform & FPSO Routing
BU and BFOU 150/250 V fire-resistant offshore instrumentation cables combine tinned-copper conductors, a mica fire barrier and HF-EPR insulation for specified essential signal circuits. The representative BFOU(i) construction has individual copper/polyester pair screens, an inner covering and a tinned-copper braid armor beneath SHF2 protection. BU is the unarmored route; the(i) and(c) screen schedules remain separate ordered variants.
Specify the fire-resistance requirement alongside the instrumentation loop data. Clouding these into one generic fire cable description can omit pair separation, drain connections or the termination space needed by the essential circuit. The mica, EPR, pair screen, armor and sheath must remain identifiable in the construction and in the installation drawing. Select MUD and temperature options explicitly instead of assuming every BFOU variant carries the same sheath duty.
Shipboard Systems & Offshore Zone Coverage
- Fixed fire-alarm, emergency shutdown and other essential instrumentation loops with specified fire-resistant cable requirements.
Route and equipment selection
Review the complete installed loop, including connections, supports, penetrations and segregation. Keep the fire-test schedule and the normal electrical loop calculation as separate checks. The screen is for the selected signal arrangement; it is not a substitute for the mica barrier.
Compare related cable duties
- 150/250 V RU and RFOU Offshore Instrumentation Cable
- NEK 606 BU and BFOU Fire-Resistant Offshore Power Cable
- Ceramic-Insulated Fire-Resistant Marine Instrumentation Cable
150/250 V BU and BFOU Fire-Resistant Marine & Offshore Technical FAQ
Specify the acceptance scope
Include the exact construction, required standard edition and test acceptance conditions in the purchase specification. Coordinate cable tests with the selected voltage, materials, installation supports and termination system. For a moving or subsea route, include the complete mechanical and environmental load schedule.
What is the engineering rule regarding 'select the complete construction' on 150/250 V BU and BFOU Fire-Resistant Instrumentation Cable?
The representative BFOU(i) build explicitly includes mica below HF-EPR on each conductor and individual copper/polyester pair screens. Overall-screened(c) variants retain their own complete construction and test schedule rather than being inferred by deleting layers from the(i) drawing.
How does 150/250 V BU and BFOU Fire-Resistant Instrumentation Cable handle route and equipment selection in field installations?
Review the complete installed loop, including connections, supports, penetrations and segregation. Keep the fire-test schedule and the normal electrical loop calculation as separate checks. The screen is for the selected signal arrangement; it is not a substitute for the mica barrier.
Why is 'Compare related cable duties' critical when specifying 150/250 V BU and BFOU Fire-Resistant Instrumentation Cable?
150/250 V RU and RFOU Offshore Instrumentation Cable NEK 606 BU and BFOU Fire-Resistant Offshore Power Cable Ceramic-Insulated Fire-Resistant Marine Instrumentation Cable
Which conductor stranding, core identification, and jacket compounds are used in 150/250 V BU and BFOU Fire-Resistant Instrumentation Cable?
Conductors: Class 2 tinned copper.; Fire barrier /insulation: Mica tape(s) plus HF-EPR on each conductor.; Selected screen: Copper/polyester individual pair screens with drains.; BFOU covering /armor: Halogen-free inner covering plus tinned-copper braid.; Sheath: SHF2 or specifically selected SHF MUD.
Use each value for the stated construction and operating condition. Nominal dimensions belong to the listed configuration; include the voltage, core schedule and installation duty when selecting a size.
TEBAOFLEX® — 150/250 V BU and BFOU Fire-Resistant Instrumentation Cable technical parameters
| Parameter | Value / condition |
|---|---|
| Rated voltage | 150/250 V |
| Representative configuration | BFOU(i)2 × 2 × 0.75 mm² |
| Representative OD /mass | 14.6 mm /405 kg/km |
| Resistance at 20°C | 26.3 Ω/km |
| Mutual capacitance | 85 nF/km |
| Inductance at 1 kHz | 0.731 mH/km |
| Maximum L/R at 1 kHz | 20 µH/Ω |
TEBAOFLEX® — 150/250 V BU and BFOU Fire-Resistant Instrumentation Cable configuration comparison
| Configuration | Selection scope |
|---|---|
| BU(i) /BU(c) | Unarmored fire-resistant instrumentation, selected screen layout. |
| BFOU(i) | Mica/HF-EPR with individual screens and braid armor. |
| BFOU(c) | Overall-screened fire-resistant variant; complete ordered schedule required. |
| RFOU instrumentation | Separate normal flame-retardant EPR route. |
TEBAOFLEX® — BFOU(i) fire-resistant instrument cable nominal dimensions
| BFOU(i)configuration (mm²) | OD (mm) | Mass (kg/km) | Resistance 20°C(Ω/km) |
|---|---|---|---|
| BFOU(i)2 × 2 × 0.75 | 14.6 | 405 | 26.3 |
| BFOU(i)4 × 2 × 0.75 | 17.9 | 560 | 26.3 |
| BFOU(i)7 × 2 × 0.75 | 20.6 | 765 | 26.3 |
Configuration and duty selection
Scroll the size table horizontally to compare all columns.
Compare both circuit integrity and signal-loop loading
A fire-resistant cable still has conductor resistance, capacitance and inductance that belong in the instrumentation design. For the 0.75 mm² representative,200 m of total conductor length gives 26.3 Ω/km × 0.2 km=5.26 Ω at 20°C before connections and temperature correction. Keep that electrical check separate from the required fire-test acceptance schedule.
Selection guide: The representative BFOU(i) build explicitly includes mica below HF-EPR on each conductor and individual copper/polyester pair screens. Overall-screened(c) variants retain their own complete construction and test schedule rather than being inferred by deleting layers from the(i) drawing.
Ordering & Quotation Checklist: Send essential-circuit duty, pair/triad count and area, individual/common screens, fire-test conditions, electrical loop limits, glands, armor bonds and sheath environment.
Request Quotation & Datasheet for This Cable
Need factory pricing, cross-section drawing or a full PDF datasheet for 150/250 V BU and BFOU Fire-Resistant Instrumentation Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.