NEK 606 BU and BFOU Fire-Resistant Offshore Power Cable

Fixed offshore power and control circuits with specified fire-resistant cable requirements. Rated voltage: 0.6/1 kV Maximum conductor /short-circuit temperature: 90°C /250°C Base minimum laying temperature: −20°C Representative BFOU 3 × 25/16 OD: 28.1 mm Representative mass /bend radius: 1640 kg/km /169 mm

  • Rated voltage0.6/1 kV
  • Maximum conductor /short-circuit temperature90°C /250°C
  • Base minimum laying temperature−20°C
  • Representative BFOU 3 × 25/16 OD28.1 mm
  • Representative mass /bend radius1640 kg/km /169 mm
  • Representative resistance at 20°C0.734 Ω/km
  • Representative current at 45°C free air110 A
  • BUMica/HF-EPR fire-resistant, unarmored.

NEK 606 BU and BFOU Fire-Resistant Shipboard & Offshore Identification

  • Type: Industrial Cables
  • Rated voltage: 0.6/1 kV
  • Maximum conductor /short-circuit temperature: 90°C /250°C
  • Base minimum laying temperature: −20°C

Marine Electrical, Temperature & Bend Ratings

  • Representative BFOU 3 × 25/16 OD: 28.1 mm
  • Representative mass /bend radius: 1640 kg/km /169 mm
  • Representative resistance at 20°C: 0.734 Ω/km
  • Representative current at 45°C free air: 110 A
  • BU: Mica/HF-EPR fire-resistant, unarmored.

NEK 606 BU and BFOU Fire-Resistant Halogen-Free / Armored Architecture

  • Conductors: Class 2 tinned copper; separately selected F-Class 5 alternative.
  • Fire barrier /insulation: Mica tape(s) plus HF-EPR on each conductor.
  • BFOU inner covering: Halogen-free compound.
  • BFOU armor: Tinned-copper braid.
  • Outer sheath: SHF2 or explicitly selected SHF MUD.

Select the complete construction

The mica layer sits beneath the HF-EPR on each power conductor. The selected build is ordinary power/control geometry; it does not inherit the symmetric ground-core arrangement of a separate BFOU VFD construction.

Shipboard Fire Integrity & EMC Performance

  • Select the complete construction: The mica layer sits beneath the HF-EPR on each power conductor.
  • Route and equipment selection: For essential equipment and emergency circuits, coordinate the cable with supports, penetrations, joints and termination arrangements required by the installation.
  • Configuration and duty selection: Scroll the size table horizontally to compare all columns.
  • Compare fire performance and armor on two independent axes: RU/RFOU identify the normal EPR route; BU/BFOU add the mica-based fire-resistant construction.

Salt Fog, Mud, Oil & Low-Smoke Resistance

  • Installation & Routing: Fixed offshore power and control circuits with specified fire-resistant cable requirements.
  • Termination & Entry Check: Use each value for the stated construction and operating condition. Nominal dimensions belong to the listed configuration; include the voltage, core schedule and installation duty when selecting a size.
  • NEK 606 IIIed.2004: Design-series reference; specify the required project edition.
  • IEC 60092-350/-351/-352/-353: Marine cable design, insulation and installation references.

IEC 60092 / NEK 606 / BS Marine Standards

  • NEK 606 IIIed.2004: Design-series reference; specify the required project edition.
  • IEC 60092-350/-351/-352/-353: Marine cable design, insulation and installation references.
  • IEC 60092-359: SHF2 sheath reference; SHF MUD is separately specified.
  • IEC 60332-1-2; IEC 60332-3-22: Flame propagation references.
  • IEC 60754-1; IEC 61034-2: Halogen and smoke-emission references.

Marine & Offshore Cable Engineering Guides

Closed marine electrical cabinets with supported power and signal cable trays on an offshore platform
Enclosed electrical equipment and supported cable trays in an offshore environment. Select power, instrument and bus circuits separately.

NEK 606 BU and BFOU Fire-Resistant Vessel, Platform & FPSO Routing

NEK 606 BU and BFOU 0.6/1 kV fire-resistant offshore power cables place a mica barrier beneath HF-EPR insulation around tinned-copper conductors. BU is unarmored. BFOU adds a halogen-free inner covering and tinned-copper braid armor under the selected SHF2 or SHF MUD sheath. The representative three-core BFOU construction uses Class 2 conductors; an F-prefixed Class 5 version is separately specified.

Select the fire-resistant power construction for the required circuit-integrity schedule and fixed offshore route. The mica barrier, conductor insulation, armor and sheath perform different functions; neither braid armor nor a flame-retardant jacket replaces the conductor fire barrier. Keep the electrical circuit and fire-test protocol distinct from the mechanical installation, including minimum bends, supports, gland dimensions and any MUD or low-temperature requirement.

Shipboard Systems & Offshore Zone Coverage

  • Fixed offshore power and control circuits with specified fire-resistant cable requirements.

Route and equipment selection

For essential equipment and emergency circuits, coordinate the cable with supports, penetrations, joints and termination arrangements required by the installation. A cable fire-test designation is not a fire-rating statement for every completed circuit or every support system.

Compare related cable duties

  • NEK 606 RU and RFOU 0.6/1 kV Offshore Power Cable
  • 150/250 V BU and BFOU Fire-Resistant Instrumentation Cable
  • NEK 606 BFOU VFD 1.8/3 kV Fire-Resistant LSZH Offshore VFD Power Cable

NEK 606 BU and BFOU Fire-Resistant Marine & Offshore Technical FAQ

Specify the acceptance scope

Include the exact construction, required standard edition and test acceptance conditions in the purchase specification. Coordinate cable tests with the selected voltage, materials, installation supports and termination system. For a moving or subsea route, include the complete mechanical and environmental load schedule.

Why is 'Select the complete construction' critical when specifying NEK 606 BU and BFOU Fire-Resistant Offshore Power Cable?

The mica layer sits beneath the HF-EPR on each power conductor. The selected build is ordinary power/control geometry; it does not inherit the symmetric ground-core arrangement of a separate BFOU VFD construction.

How should engineers address 'route and equipment selection' for NEK 606 BU and BFOU Fire-Resistant Offshore Power Cable?

For essential equipment and emergency circuits, coordinate the cable with supports, penetrations, joints and termination arrangements required by the installation. A cable fire-test designation is not a fire-rating statement for every completed circuit or every support system.

What is the engineering rule regarding 'compare related cable duties' on NEK 606 BU and BFOU Fire-Resistant Offshore Power Cable?

NEK 606 RU and RFOU 0.6/1 kV Offshore Power Cable 150/250 V BU and BFOU Fire-Resistant Instrumentation Cable NEK 606 BFOU VFD 1.8/3 kV Fire-Resistant LSZH Offshore VFD Power Cable

How are the conductors, insulation, and outer sheath structured in NEK 606 BU and BFOU Fire-Resistant Offshore Power Cable?

Conductors: Class 2 tinned copper; separately selected F-Class 5 alternative.; Fire barrier /insulation: Mica tape(s) plus HF-EPR on each conductor.; BFOU inner covering: Halogen-free compound.; BFOU armor: Tinned-copper braid.; Outer sheath: SHF2 or explicitly selected SHF MUD.

Use each value for the stated construction and operating condition. Nominal dimensions belong to the listed configuration; include the voltage, core schedule and installation duty when selecting a size.

TEBAOFLEX® — NEK 606 BU and BFOU Fire-Resistant Offshore Power Cable technical parameters

NEK 606 BU and BFOU Fire-Resistant Offshore Power Cable technical parameters
Parameter Value / condition
Rated voltage 0.6/1 kV
Maximum conductor /short-circuit temperature 90°C /250°C
Base minimum laying temperature −20°C
Representative BFOU 3 × 25/16 OD 28.1 mm
Representative mass /bend radius 1640 kg/km /169 mm
Representative resistance at 20°C 0.734 Ω/km
Representative current at 45°C free air 110 A

TEBAOFLEX® — NEK 606 BU and BFOU Fire-Resistant Offshore Power Cable configuration comparison

NEK 606 BU and BFOU Fire-Resistant Offshore Power Cable configuration comparison
Configuration Selection scope
BU Mica/HF-EPR fire-resistant, unarmored.
BFOU Mica/HF-EPR with inner covering and braid armor.
RFOU Flame-retardant EPR route with a different fire-performance task.
BFOU VFD Separate motor-supply geometry and voltage design.

TEBAOFLEX® — Class 2 BFOU nominal dimensions

Class 2 BFOU nominal dimensions
BFOU configuration (mm²) OD (mm) Mass (kg/km) Min.bend (mm)
BFOU 3 × 25/16 28.1 1640 169
BFOU 3 × 50/25 34.3 2750 206

Configuration and duty selection

Scroll the size table horizontally to compare all columns.

Compare fire performance and armor on two independent axes

RU/RFOU identify the normal EPR route; BU/BFOU add the mica-based fire-resistant construction. Within each pair, the armored and unarmored routes remain separate. A four-way selection matrix prevents a request for mechanical protection from being mistaken for a request for circuit integrity.

Selection guide: The mica layer sits beneath the HF-EPR on each power conductor. The selected build is ordinary power/control geometry; it does not inherit the symmetric ground-core arrangement of a separate BFOU VFD construction.

Ordering & Quotation Checklist: Send BU/BFOU configuration, conductor class and area, required fire-test schedule, essential-circuit route, support and gland details, braid bonding and MUD requirement.

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for NEK 606 BU and BFOU Fire-Resistant Offshore Power Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.

  • ISO 9001 Factory Direct
  • MOQ 50 m (Custom Builds)
  • 24h Engineering Reply
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    You may also like…

    NEK 606 BU and BFOU Fire-Resistant Offshore Power CableGet A Quote