275 kV HVAC 3-Core Submarine Export & ±320–600 kV HVDC Power Cable
275 kV HVAC Three-Core Submarine Export Cables (up to 3×2000 mm² Cu/Al, 400–500 MW per circuit up to 120 km) and ±320 kV to ±525 kV / ±600 kV HVDC Extruded DC-XLPE and HPTE Submarine & Land Transmission Cables (up to 3500 mm², 1,000–2,600 MW per bipole) are engineered to IEC 63026, IEC 62895, and CIGRE TB 490 / TB 623 / TB 852 for offshore wind farm export links and long-distance subsea/underground grid interconnectors.
- Model designations275 kV HVAC 3-Core Submarine Export Cable & ±320 kV / ±400 kV / ±525 kV / ±600 kV HVDC Cable
- Reference standardsIEC 62067, IEC 63026, IEC 62895, CIGRE TB 490, CIGRE TB 623, CIGRE TB 852
- Rated voltage160/275 (300) kV AC 3-Phase; ±320 kV, ±400 kV, ±525 kV & ±600 kV DC
- ConductorLongitudinally water-blocked compacted / Milliken Cu or Al (800–2000 mm² HVAC; 1200–3500 mm² HVDC)
- InsulationTriple-extruded super-clean 275 kV AC XLPE, space-charge-suppressed DC-XLPE, or 90 °C DC-HPTE
- Radial water barrierExtruded seamless lead alloy sheath (Pb) or welded aluminum laminate (land HVDC)
- Armoring & FO elementsSingle/double galvanized steel, copper or synthetic wire armor + up to 3×48F FIMT optical units
- Power capacity400–500 MW per 275 kV 3-core HVAC link (≤120 km); 1.0–2.6 GW per ±525/600 kV HVDC bipole
275 kV HVAC 3-Core Submarine Export Cable Shipboard & Offshore Identification
- Type: Oil & Gas Cable
- Model designations: 275 kV HVAC 3-Core Submarine Export Cable & ±320 kV / ±400 kV / ±525 kV / ±600 kV HVDC Cable
- Reference standards: IEC 62067, IEC 63026, IEC 62895, CIGRE TB 490, CIGRE TB 623, CIGRE TB 852
- Rated voltage: 160/275 (300) kV AC 3-Phase; ±320 kV, ±400 kV, ±525 kV & ±600 kV DC
Marine Electrical, Temperature & Bend Ratings
- Conductor: Longitudinally water-blocked compacted / Milliken Cu or Al (800–2000 mm² HVAC; 1200–3500 mm² HVDC
- Insulation: Triple-extruded super-clean 275 kV AC XLPE, space-charge-suppressed DC-XLPE, or 90 °C DC-HPTE
- Radial water barrier: Extruded seamless lead alloy sheath (Pb) or welded aluminum laminate (land HVDC
- Armoring & FO elements: Single/double galvanized steel, copper or synthetic wire armor + up to 3×48F FIMT optical units
- Power capacity: 400–500 MW per 275 kV 3-core HVAC link (≤120 km); 1.0–2.6 GW per ±525/600 kV HVDC bipole
275 kV HVAC 3-Core Submarine Export Cable Halogen-Free / Armored Architecture
Built for deep-water laying tensioners, seabed burial plows, and multi-decade subsea operation, our 275 kV HVAC and ±525/600 kV HVDC cables combine hermetically sealed lead sheaths with heavy wire armoring.
- Water-Blocked Conductor: Compacted circular or Milliken segmental copper/aluminum conductor (up to 2000 mm² HVAC / 3500 mm² HVDC) sealed with water-blocking compound.
- Triple-Extruded HV/HVDC Dielectric: Super-clean 275 kV AC XLPE, space-charge-suppressed DC-XLPE, or high-temperature DC-HPTE with bonded semi-conducting screens.
- Radial Water Barrier: Seamless extruded lead alloy sheath (Pb) with semi-conducting PE anti-corrosion sheath (or welded aluminum laminate on land HVDC).
- Lay-Up & Optical Units (3-Core HVAC): Three phase cores planetary-stranded with shaped extruded PE fillers and up to 3 × 48-fiber stainless-steel FIMT optical elements.
- Armoring & Serving: Single or counter-helical double layer of galvanized steel, copper, or synthetic armor wires + bitumen and polypropylene (PP) yarn outer serving.
Shipboard Fire Integrity & EMC Performance
- 275 kV 3-Core HVAC: 400–500 MW / cable: Upgrading from 220 kV to 275 kV (up to 3×2000 mm²) boosts export capacity by up to 20% while reducing seabed corridor width and installation vessel campaigns.
- Up to 3 × 48F integrated optical units: Up to three armored fiber-optic elements (48 G.652.D/G.657.A1 fibers each) are laid in the 3-core interstices for SCADA protection and DAS/DTS thermal monitoring.
- ±320 kV to ±525 kV / ±600 kV HVDC: Space-charge-modified DC-XLPE and DC-HPTE insulation systems prevent field inversion breakdown during thermal loading and converter transients.
- CIGRE TB 490 / TB 623 / TB 852 qualified: Designed to pass full mechanical coiling/bending tensile tests (per CIGRE TB 623) followed by 360-day electrical prequalification and type tests.
Salt Fog, Mud, Oil & Low-Smoke Resistance
- Seamless extruded lead alloy radial barrier: Provides 100% impermeability to hydrostatic seawater ingress across 40-year subsea service life under high external pressure.
- Low-loss non-magnetic & hybrid armoring: 275 kV 3-core HVAC cables optimize armor wire material (galvanized steel, copper/stainless, or high-modulus synthetic wires) to minimize AC armor eddy/hysteresis losses.
- Shaped extruded PE interstitial fillers: Precision-extruded polymeric filler profiles support the heavy lead-sheathed cores against radial crushing on tensioners and cable-laying carousels.
- Up to 3500 mm² HVDC conductor cross-sections: Large-section copper and aluminum conductors enable 2.0 GW+ bipole transmission over single-circuit underground or subsea trenches.
IEC 60092 / NEK 606 / BS Marine Standards
- CIGRE TB 490 & CIGRE TB 623: Recommendations for mechanical and electrical testing of long AC submarine cables up to 500 kV
- CIGRE TB 852 & IEC 62895: Testing of extruded HVDC cable systems up to 500 kV / 600 kV DC
- IEC 63026 & IEC 62067: Submarine power cables with extruded insulation and their accessories
- ITU-T G.652.D / G.657.A1: Integrated submarine optical fibers for SCADA and DAS/DTS monitoring
Marine & Offshore Cable Engineering Guides

275 kV HVAC 3-Core Submarine Export Cable Vessel, Platform & FPSO Routing
As offshore wind farms move 60–120 km from shore with turbine arrays connected via our66 kV static and dynamic submarine inter-array cables, stepping the offshore substation export voltage up from 220 kV to 275 kV AC (Um 300 kV) increases transmissible active power by up to 20%—delivering 400 MW to 500 MW through a single three-core submarine export cable (3×800 mm² up to 3×2000 mm² Cu or Al) without intermediate reactive compensation up to 100–120 km. Each 275 kV phase core features a longitudinally water-blocked compacted conductor, triple-extruded super-clean XLPE dielectric, semi-conducting water-blocking tapes, an extruded seamless lead alloy radial water barrier (Pb), and a PE anti-corrosion sheath. Three phase cores are planetary-laid together with shaped extruded PE fillers and up to 3 laser-welded stainless-steel optical elements (up to 48 fibers each), armored with galvanized steel, non-magnetic copper/stainless, or synthetic armor wires, and finished with bitumen-impregnated polypropylene (PP) yarn serving.
Beyond 120 km offshore—or for multi-gigawatt cross-border interconnectors—capacitive charging currents limit AC transmission, requiring High-Voltage Direct Current (HVDC) Extruded Submarine and Land Cables (±320 kV, ±400 kV, ±525 kV and ±600 kV). Qualified to CIGRE TB 490, TB 623 and TB 852 / IEC 62895 under both Line-Commutated Converter (LCC, polarity reversal) and Voltage-Sourced Converter (VSC) regimes, these single-core HVDC cables utilize modified space-charge-suppressed DC-XLPE (for ±320 kV to ±525 kV submarine and land circuits) or high-temperature thermoplastic DC-HPTE (up to ±600 kV land/subsea) over conductors up to 3500 mm², delivering 1,000 MW to 2,600 MW per Metallic-Return Bipole. For onshore 69–220 kV AC substation feeders, compareIEC 60840 HV XLPE & HPTE Underground Cable.
Shipboard Systems & Offshore Zone Coverage
- 275 kV HVAC Three-Core Offshore Wind Export Systems: Connects offshore collector converter/transformer topsides to onshore grid landfalls over route lengths up to 100–120 km (50 Hz or 60 Hz) in water depths from shallow intertidal zones down to deep-water trenches.
- ±320 kV, ±400 kV, ±525 kV & ±600 kV HVDC Submarine & Land Interconnectors: Far-shore offshore wind HVDC converter links (>120 km), subsea island/inter-country grid interconnectors, and long-distance underground HVDC transmission corridors.
275 kV HVAC 3-Core Submarine Export Cable Marine & Offshore Technical FAQ
Why are offshore wind farms transitioning from 220 kV to 275 kV 3-core HVAC export cables?
Increasing the export voltage from 220 kV to 275 kV delivers up to 20% more transmissible power per three-core cable—reaching 400 MW to 500 MW on a single 3×1600–2000 mm² circuit over distances up to 100–120 km, reducing the number of export trenches required for a 1–1.5 GW wind farm.
At what offshore distance does ±320 kV–±525 kV HVDC replace 275 kV HVAC?
For submarine export routes up to 100–120 km, 275 kV 3-core HVAC is typically more economical because it avoids offshore HVDC converter platforms. Beyond 100–120 km, AC capacitive charging current consumes too much conductor ampacity, making ±320 kV or ±525 kV HVDC single-core bipole cables the optimal choice.
Why do HVDC extruded cables require special DC-XLPE or DC-HPTE compounds?
Under high DC electric stress and thermal gradients across the insulation wall, standard AC XLPE accumulates trapped space charges that can trigger dielectric breakdown during load drops or polarity reversals. Modified DC-XLPE and DC-HPTE suppress space-charge accumulation up to ±525 kV and ±600 kV.
How many optical fibers can be integrated into a 275 kV 3-core submarine export cable?
Up to 3 separate optical elements—each housing up to 48 single-mode fibers (144 fibers total) inside laser-welded stainless-steel tubes and PE sheaths—can be laid in the outer interstices alongside the shaped PE fillers.
Technical parameters for 275 kV HVAC 3-core submarine export cables (3×800 to 3×2000 mm²) and ±320 kV to ±600 kV HVDC extruded submarine and land transmission cables (1200–3500 mm²).
TEBAOFLEX® — 275 kV HVAC 3-Core Submarine Export & ±320–600 kV HVDC Power Cable
| Rated Voltage | Formation & Size (mm²) | Conductor Material | Insulation System | Radial Water Barrier | Optical Elements | Approx. Overall OD (mm) | Approx. Air Weight (kg/m) | Max. DC Res. 20 °C (Ω/km) | Active Power Capacity (50 Hz) |
|---|---|---|---|---|---|---|---|---|---|
| 160/275 (300) kV AC | 3 × 800 | Compacted Cu / Al | Triple-extruded HV XLPE | Extruded Lead Alloy (Pb) | Up to 3 × 48F | 245 | 92 (Cu) / 76 (Al) | 0.0221 / 0.0367 | 320 – 360 MW |
| 160/275 (300) kV AC | 3 × 1000 | Compacted / Milliken Cu/Al | Triple-extruded HV XLPE | Extruded Lead Alloy (Pb) | Up to 3 × 48F | 258 | 104 (Cu) / 84 (Al) | 0.0176 / 0.0291 | 360 – 400 MW |
| 160/275 (300) kV AC | 3 × 1200 | Milliken Segmental Cu/Al | Triple-extruded HV XLPE | Extruded Lead Alloy (Pb) | Up to 3 × 48F | 270 | 116 (Cu) / 92 (Al) | 0.0151 / 0.0247 | 395 – 435 MW |
| 160/275 (300) kV AC | 3 × 1600 | Milliken Segmental Cu/Al | Triple-extruded HV XLPE | Extruded Lead Alloy (Pb) | Up to 3 × 48F | 288 | 138 (Cu) / 106 (Al) | 0.0113 / 0.0186 | 440 – 475 MW |
| 160/275 (300) kV AC | 3 × 2000 | Milliken Segmental Cu/Al | Triple-extruded HV XLPE | Extruded Lead Alloy (Pb) | Up to 3 × 48F | 302 | 158 (Cu) / 118 (Al) | 0.0090 / 0.0149 | 475 – 500 MW |
TEBAOFLEX® — 275 kV HVAC 3-Core Submarine Export & ±320–600 kV HVDC Power Cable
| HVDC Voltage Rating | Application Type | Conductor Size (mm²) | Dielectric Material | Radial Barrier & Armor | Approx. Cable OD (mm) | Approx. Weight (kg/m) | Max. Conductor Temp | Bipole Transmission Capacity |
|---|---|---|---|---|---|---|---|---|
| ±320 kV DC | Submarine HVDC | 1 × 1200 to 1 × 2500 Cu/Al | DC-XLPE (Space-charge mod.) | Lead sheath + Single/Double SWA | 115 – 142 | 34 – 62 | +70 °C / +90 °C | 900 – 1,350 MW |
| ±400 kV DC | Submarine HVDC | 1 × 1600 to 1 × 3000 Cu/Al | DC-XLPE (Space-charge mod.) | Lead sheath + Single/Double SWA | 128 – 155 | 42 – 74 | +70 °C / +90 °C | 1,200 – 1,800 MW |
| ±525 kV DC | Submarine HVDC | 1 × 2000 to 1 × 3000 Cu/Al | DC-XLPE / DC-HPTE | Lead sheath + Single/Double SWA | 140 – 168 | 48 – 82 | +70 °C / +90 °C | 1,800 – 2,200 MW |
| ±525 kV DC | Land Underground HVDC | 1 × 2000 to 1 × 3500 Al/Cu | DC-XLPE / DC-HPTE | Laminated Al foil + HDPE ST7 | 125 – 152 | 16 – 45 | +70 °C / +90 °C | 1,800 – 2,500 MW |
| ±600 kV DC | Land / Subsea HVDC | 1 × 2500 to 1 × 3500 Cu/Al | DC-HPTE (Thermoplastic) | Lead sheath (Subsea) / Al foil (Land) | 145 – 172 | 22 – 86 | +90 °C | 2,200 – 2,600 MW |
Selection guide: Specify 275 kV HVAC 3-Core Submarine Export (800–2000 mm²) or ±320/±400/±525/±600 kV HVDC Submarine/Land (1200–3500 mm²), conductor metal (Cu or Al), water depth, route length, and fiber-optic core count.
Ordering & Quotation Checklist: Request an engineering proposal for 275 kV HVAC 3-core submarine export cables or ±320 kV to ±600 kV HVDC submarine and land transmission cables.
66 kV Static Offshore Wind Array Cable
Static submarine inter-array connections between fixed offshore wind equipment and collection infrastructure.
IEC 60840 High-Voltage XLPE (69–220 kV) & HPTE 105 °C Underground Power Cable
IEC 60840 / IEC 62067 Onshore HV XLPE (69–220 kV) & HPTE 105 °C Recyclable MV/HV
00/12/FO2, RMP200 & 6XM524 Pipe Crawler & C-3400 / 26XM520 Cleaning Robot Cable
00/12/FO2, 00/20/FOX2 (Electro-Optical), 524/11 (11-Core Copper), RMP200 / RMP300 / RMP350 / RMP500, 6XM524, 1HRS347
Request Quotation & Datasheet for This Cable
Need factory pricing, cross-section drawing or a full PDF datasheet for 275 kV HVAC 3-Core Submarine Export & ±320–600 kV HVDC Power Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.
- ISO 9001 Factory Direct
- MOQ 50 m (Custom Builds)
- 24h Engineering Reply