JIS C 3410 3.6/6 kV & 6/10 kV SPYCB / TPYCY MV Marine Power Cable
JIS C 3410 (2010) 3.6/6 kV and 6/10 kV SPYCB, SPYCBY, FA-SPYCB, FA-SPYCBY (single-core with non-magnetic copper-alloy wire braid armor CB) and TPYC, TPYCY, FA-TPYC, FA-TPYCY (three-core with galvanized steel wire braid C or copper-alloy wire braid CB) are medium-voltage marine propulsion and main distribution cables engineered to JIS C 3410 and IEC 60092-354.
- Model designations(FA-)SPYCB, (FA-)SPYCBY (1-Core) & (FA-)TPYC, (FA-)TPYCY (3-Core)
- StandardsJIS C 3410 (2010), IEC 60092-350 / 354, IEC 60332-1 & IEC 60332-3 Cat A (FA-)
- Rated voltage U0/U3.6/6 kV & 6/10 kV medium-voltage marine propulsion & distribution
- Conductor (S / T)Stranded tinned annealed copper wires per JIS C 3410 (10 to 300 mm²)
- Insulation & Screen (P)90 °C EPR / HEPR rubber + semi-conducting layers + ~0.1 mm copper tape screen
- Inner Sheath & ArmorPVC inner sheath (Y) + ≥90% coverage copper-alloy (CB) or steel (C) wire braid
- Outer covering (-Y)Red paint over exposed braid, or extruded red PVC protective oversheath (-Y)
- Thermal & cold option+90 °C max conductor temp; optional Cold Type (C) passing CSA 22.2 (-40 °C / -35 °C)
JIS C 3410 3.6/6 kV & 6/10 kV SPYCB Shipboard & Offshore Identification
- Type: Oil & Gas Cable
- Model designations: FA-)SPYCB, (FA-)SPYCBY (1-Core) & (FA-)TPYC, (FA-)TPYCY (3-Core
- Standards: JIS C 3410 (2010), IEC 60092-350 / 354, IEC 60332-1 & IEC 60332-3 Cat A (FA-
- Rated voltage U0/U: 3.6/6 kV & 6/10 kV medium-voltage marine propulsion & distribution
Marine Electrical, Temperature & Bend Ratings
- Conductor (S / T): Stranded tinned annealed copper wires per JIS C 3410 (10 to 300 mm²
- Insulation & Screen (P): 90 °C EPR / HEPR rubber + semi-conducting layers + ~0.1 mm copper tape screen
- Inner Sheath & Armor: PVC inner sheath (Y) + ≥90% coverage copper-alloy (CB) or steel (C) wire braid
- Outer covering (-Y): Red paint over exposed braid, or extruded red PVC protective oversheath (-Y
- Thermal & cold option: +90 °C max conductor temp; optional Cold Type (C) passing CSA 22.2 (-40 °C / -35 °C
JIS C 3410 3.6/6 kV & 6/10 kV SPYCB Halogen-Free / Armored Architecture
JIS C 3410 3.6/6 kV and 6/10 kV cables pair tinned copper conductors with semi-con screened 90 °C EPR/HEPR insulation, 0.1 mm copper tape phase screens, a PVC inner sheath, and ≥90% wire braid armor.
- Conductor (S / T): Stranded tinned annealed copper wires per JIS C 3410 (S = Single-core, T = Three-core).
- Conductor Screen & Insulation (P): Semi-conducting tape/compound layer + 90 °C EPR/HEPR rubber insulation per JIS C 3410.
- Insulation Screen: Non-metallic semi-conducting layer + metallic copper tape screen (~0.1 mm thickness) with Red, Yellow, Blue core ID on 3C.
- Inner Sheath (Y) & Armor (C / CB): Extruded PVC inner sheath (Y) + ≥90% coverage galvanized steel wire braid (C, painted red) or copper-alloy wire braid (CB on 1C).
- Outer Protective Covering (-Y): Extruded red flame-retardant PVC outer sheath on SPYCBY, FA-SPYCBY, TPYCY, and FA-TPYCY.
Shipboard Fire Integrity & EMC Performance
- Copper-tape screened 90 °C EPR/HEPR: Each phase conductor is triple-protected by a semi-conducting conductor screen, 90 °C EPR/HEPR dielectric ('P'), a semi-conducting insulation screen, and an ~0.1 mm metallic copper tape shield.
- Non-magnetic CB braid on 1-core: Single-core SPYCB / SPYCBY uses a ≥90% coverage copper-alloy wire braid ('CB') to eliminate single-core AC magnetic eddy-current losses.
- FA- IEC 60332-3 Cat A & Red -Y sheath: Prefix 'FA-' meets IEC 60332-3 Category A bunched fire testing; suffix '-Y' (SPYCBY / TPYCY) adds a red flame-retardant PVC oversheath over the armor.
- Optional -40 °C Cold Type (C): Available with suffix '(C)' passing CSA C22.2 No. 0.3 cold bend (-40 °C) and cold impact (-35 °C) for ice-class and Arctic LNG vessels.
Salt Fog, Mud, Oil & Low-Smoke Resistance
- 0.1 mm metallic copper tape screen: Confines the radial electric field and provides a dedicated fault-current path on every 3.6/6 kV and 6/10 kV core.
- ≥90% wire braid armor coverage: High-density galvanized steel (C) or copper-alloy (CB) wire braid shields the cable against shipboard vibration and mechanical impact.
- Red HV visual identification: Exposed steel braid on TPYC is uniformly coated with red paint, and oversheathed SPYCBY / TPYCY cables use a bright red PVC outer jacket to identify MV/HV shipboard circuits.
- Tinned copper marine corrosion defense: All phase conductors are stranded from tinned annealed copper wires per JIS C 3410 to prevent salt-fog and bilge oxidation.
IEC 60092 / NEK 606 / BS Marine Standards
- JIS C 3410: 2010) & IEC 60092-350 / 354 (3.6/6 kV & 6/10 kV shipboard HV/MV power cables
- IEC 60332-1-2 vertical flame retardance & IEC 60332-3 Category A bunched flame test: FA- prefix
- CSA C22.2 No. 0.3: -40 °C cold bend / -35 °C cold impact on Cold Type '(C)'
- JIS C 3410 EPR/HEPR 90 °C insulation, 0.1 mm copper tape screen & ≥90% wire braid armor
Marine & Offshore Cable Engineering Guides
Factory Sample & Cut-Section Verification
TEBAOFLEX Production Sample
Authentic TEBAOFLEX workshop cut-end and stripped sample photographs of JIS C 3410 SPYCB 3.6/6 kV–6/10 kV single-core gray-sheathed wire-braid armored MV marine power cable, documenting actual conductor stranding, radial wall concentricity, and outer jacket extrusion prior to reel dispatch.




JIS C 3410 3.6/6 kV & 6/10 kV SPYCB Vessel, Platform & FPSO Routing
In Japanese, Korean, and Asian commercial shipbuilding—including large LNG carriers, VLCCs, ultra-large container ships, and heavy crane vessels—JIS C 3410 (2010) High/Medium-Voltage Power Cables (3.6/6 kV and 6/10 kV) are specified for 3.3 kV, 6.6 kV, and 11 kV main generator switchboards, bow thruster motors, and cargo compressor drives. While our0.6/1 kV JIS C 3410 DPYC, TPYC, MPYC & TTYC shipboard cable pagecovers low-voltage power and 150/250 V instrumentation, this dedicated specification covers the screened medium-voltage JIS C 3410 series: single-core SPYCB / SPYCBY / FA-SPYCB / FA-SPYCBY (1×10 mm² to 1×300 mm²) and three-core TPYC / TPYCY / FA-TPYC / FA-TPYCY (3×10 mm² to 3×150 mm²).
Why do single-core JIS C 3410 medium-voltage cables use SPYCB (CB = Copper-Alloy Wire Braid) instead of SPYC (C = Galvanized Steel Wire Braid)? On single-core AC medium-voltage feeders, a magnetic steel wire armor would generate severe eddy-current and hysteresis heating; therefore, JIS C 3410 mandates a non-magnetic copper-alloy wire braid (CB, ≥90% coverage) on single-core SPYCB and SPYCBY, while three-core balanced cables (TPYC / TPYCY) use galvanized steel wire braid (C, painted red) or optional CB braid, with FA- denoting IEC 60332-3 Category A bunched flame retardance. Compare also with our European offshoreNEK 606 3.6/6–12/20 kV RFOU MV cablesandRFCU 3.6/6–18/30 kV GSWB-armored offshore HEPR cables.
Shipboard Systems & Offshore Zone Coverage
- Single-core 3.6/6 kV & 6/10 kV (FA-)SPYCB and (FA-)SPYCBY (1×10 mm² to 1×300 mm²) are installed in trefoil cleats for high-current main propulsion generators, shaft alternators, shore-to-ship HVSC (AMP) connection buses, and high-capacity propulsion transformers.
- Three-core 3.6/6 kV & 6/10 kV (FA-)TPYC and (FA-)TPYCY (3×10 mm² to 3×150 mm²) (with Red, Yellow, and Blue phase identification) feed medium-voltage bow/stern thrusters, ballast water treatment pumps, and deck cargo machinery.
JIS C 3410 3.6/6 kV & 6/10 kV SPYCB Marine & Offshore Technical FAQ
How do I decode JIS C 3410 medium-voltage designations like FA-SPYCBY and FA-TPYCY?
'FA-' denotes Flame-Arresting (passing IEC 60332-3 Category A bunched flame test). 'S' is 1-core and 'T' is 3-core. 'P' is 90 °C EPR/HEPR insulation (with semi-conducting screens and 0.1 mm copper tape shield on 3.6/6 kV and 6/10 kV grades). The first 'Y' is the PVC inner sheath; 'C' is galvanized steel wire braid armor ('CB' is non-magnetic copper-alloy wire braid armor on single-core cables); and the final 'Y' is the red PVC outer protective sheath.
Why do single-core 3.6/6 kV and 6/10 kV JIS C 3410 cables use 'CB' (SPYCB) armor?
Single-core AC cables carrying high current induce circulating eddy currents if surrounded by magnetic steel wire armor. Therefore, JIS C 3410 specifies a non-magnetic copper-alloy wire braid ('CB') on all single-core SPYCB and SPYCBY medium-voltage cables.
What is the difference between TPYCY 0.6/1 kV and TPYCY 3.6/6 kV or 6/10 kV?
Unlike 0.6/1 kV low-voltage TPYCY, the 3.6/6 kV and 6/10 kV medium-voltage TPYCY incorporates a semi-conducting conductor screen, thicker radial EPR/HEPR insulation, a semi-conducting insulation screen, and a 0.1 mm metallic copper tape screen around each individual phase core, finished with a red outer sheath.
Is an Arctic / Cold Type version available for ice-class LNG vessels?
Yes. Adding the '(C)' Cold Type suffix supplies the cable with cold-resistant compounds tested to CSA C22.2 No. 0.3 for -40 °C cold bend and -35 °C cold impact.
Full JIS C 3410 (2010) dimensional, strand configuration, overall diameter tolerance, conductor resistance, and weight tables for 3.6/6 kV and 6/10 kV (FA-)SPYCB, (FA-)SPYCBY, (FA-)TPYC, and (FA-)TPYCY shipboard medium-voltage cables.
TEBAOFLEX® — JIS C 3410 3.6/6 kV & 6/10 kV SPYCB / TPYCY MV Marine Power Cable
| Cores × Area (mm²) | Strand Config (No./mm) | Conductor Ø (mm) | (FA-)SPYCB / TPYC Nom. OD ± Tol (mm) | (FA-)SPYCBY / TPYCY Nom. OD ± Tol (mm) | Max. DC Resistance at 20 °C (Ω/km) | Weight SPYCB / TPYC (kg/km) | Weight SPYCBY / TPYCY (kg/km) |
|---|---|---|---|---|---|---|---|
| 1 × 10 (SPYCB/Y) | 7 / 1.35 | 4.05 | 17.6 ± 0.7 | 19.8 ± 0.8 | 1.840 | 560 | 640 |
| 1 × 16 (SPYCB/Y) | 7 / 1.70 | 5.10 | 18.8 ± 0.8 | 21.2 ± 0.8 | 1.160 | 660 | 755 |
| 1 × 25 (SPYCB/Y) | 7 / 2.14 | 6.42 | 20.1 ± 0.8 | 22.5 ± 0.9 | 0.734 | 795 | 895 |
| 1 × 35 (SPYCB/Y) | 7 / 2.52 | 7.56 | 21.5 ± 0.9 | 23.9 ± 1.0 | 0.529 | 940 | 1,050 |
| 1 × 50 (SPYCB/Y) | 19 / 1.78 | 8.90 | 22.8 ± 0.9 | 25.4 ± 1.0 | 0.391 | 1,110 | 1,230 |
| 1 × 70 (SPYCB/Y) | 19 / 2.14 | 10.70 | 24.8 ± 1.0 | 27.4 ± 1.1 | 0.270 | 1,380 | 1,520 |
| 1 × 95 (SPYCB/Y) | 19 / 2.52 | 12.60 | 26.9 ± 1.1 | 29.7 ± 1.2 | 0.195 | 1,710 | 1,870 |
| 1 × 120 (SPYCB/Y) | 37 / 2.03 | 14.21 | 28.7 ± 1.1 | 31.5 ± 1.3 | 0.154 | 2,010 | 2,180 |
| 1 × 150 (SPYCB/Y) | 37 / 2.25 | 15.75 | 30.3 ± 1.2 | 33.3 ± 1.3 | 0.126 | 2,330 | 2,520 |
| 1 × 185 (SPYCB/Y) | 37 / 2.52 | 17.64 | 32.8 ± 1.3 | 35.8 ± 1.4 | 0.100 | 2,890 | 3,090 |
| 1 × 240 (SPYCB/Y) | 61 / 2.25 | 20.25 | 35.9 ± 1.4 | 39.3 ± 1.6 | 0.0762 | 3,590 | 3,830 |
| 1 × 300 (SPYCB/Y) | 61 / 2.52 | 22.68 | 38.9 ± 1.6 | 42.5 ± 1.6 | 0.0607 | 4,330 | 4,610 |
| 3 × 16 (TPYC/Y) | 7 / 1.70 | 5.10 | 36.5 ± 1.5 | 39.9 ± 1.6 | 1.160 | 1,920 | 2,170 |
| 3 × 35 (TPYC/Y) | 7 / 2.52 | 7.56 | 42.2 ± 1.6 | 46.0 ± 1.7 | 0.529 | 2,800 | 3,120 |
| 3 × 70 (TPYC/Y) | 19 / 2.14 | 10.70 | 49.6 ± 1.8 | 53.6 ± 1.9 | 0.270 | 4,210 | 4,610 |
| 3 × 120 (TPYC/Y) | 37 / 2.03 | 14.21 | 57.8 ± 2.0 | 62.2 ± 2.1 | 0.154 | 6,210 | 6,720 |
| 3 × 150 (TPYC/Y) | 37 / 2.52 | 15.75 | 61.6 ± 2.1 | 66.2 ± 2.2 | 0.126 | 7,250 | 7,820 |
TEBAOFLEX® — JIS C 3410 3.6/6 kV & 6/10 kV SPYCB / TPYCY MV Marine Power Cable
| Cores × Area (mm²) | Strand Config (No./mm) | Conductor Ø (mm) | (FA-)SPYCB / TPYC Nom. OD ± Tol (mm) | (FA-)SPYCBY / TPYCY Nom. OD ± Tol (mm) | Max. DC Resistance at 20 °C (Ω/km) | Weight SPYCB / TPYC (kg/km) | Weight SPYCBY / TPYCY (kg/km) |
|---|---|---|---|---|---|---|---|
| 1 × 16 (6/10kV SPYCB/Y) | 7 / 1.70 | 5.10 | 20.8 ± 0.8 | 23.2 ± 0.9 | 1.160 | 765 | 870 |
| 1 × 25 (6/10kV SPYCB/Y) | 7 / 2.14 | 6.42 | 22.1 ± 0.9 | 24.7 ± 1.0 | 0.734 | 910 | 1,030 |
| 1 × 35 (6/10kV SPYCB/Y) | 7 / 2.52 | 7.56 | 23.5 ± 0.9 | 26.1 ± 1.0 | 0.529 | 1,060 | 1,190 |
| 1 × 50 (6/10kV SPYCB/Y) | 19 / 1.78 | 8.90 | 24.8 ± 1.0 | 27.4 ± 1.1 | 0.391 | 1,230 | 1,360 |
| 1 × 70 (6/10kV SPYCB/Y) | 19 / 2.14 | 10.70 | 26.8 ± 1.1 | 29.6 ± 1.2 | 0.270 | 1,510 | 1,670 |
| 1 × 95 (6/10kV SPYCB/Y) | 19 / 2.52 | 12.60 | 28.9 ± 1.2 | 31.7 ± 1.3 | 0.195 | 1,850 | 2,020 |
| 1 × 120 (6/10kV SPYCB/Y) | 37 / 2.03 | 14.21 | 30.5 ± 1.2 | 33.5 ± 1.3 | 0.154 | 2,150 | 2,340 |
| 1 × 150 (6/10kV SPYCB/Y) | 37 / 2.25 | 15.75 | 32.8 ± 1.3 | 35.8 ± 1.4 | 0.126 | 2,610 | 2,820 |
| 1 × 185 (6/10kV SPYCB/Y) | 37 / 2.52 | 17.64 | 34.8 ± 1.4 | 38.2 ± 1.5 | 0.100 | 3,060 | 3,290 |
| 1 × 240 (6/10kV SPYCB/Y) | 61 / 2.25 | 20.25 | 37.7 ± 1.5 | 41.1 ± 1.6 | 0.0762 | 3,760 | 4,010 |
| 1 × 300 (6/10kV SPYCB/Y) | 61 / 2.52 | 22.68 | 40.3 ± 1.6 | 43.9 ± 1.7 | 0.0607 | 4,470 | 4,760 |
| 3 × 16 (6/10kV TPYC/Y) | 7 / 1.70 | 5.10 | 41.0 ± 1.6 | 44.6 ± 1.7 | 1.160 | 2,290 | 2,590 |
| 3 × 35 (6/10kV TPYC/Y) | 7 / 2.52 | 7.56 | 46.7 ± 1.7 | 50.7 ± 1.8 | 0.529 | 3,220 | 3,590 |
| 3 × 50 (6/10kV TPYC/Y) | 19 / 1.78 | 8.90 | 49.8 ± 1.8 | 53.8 ± 1.9 | 0.391 | 3,780 | 4,180 |
| 3 × 70 (6/10kV TPYC/Y) | 19 / 2.14 | 10.70 | 54.1 ± 1.9 | 58.5 ± 2.0 | 0.270 | 4,690 | 5,170 |
| 3 × 95 (6/10kV TPYC/Y) | 19 / 2.52 | 12.60 | 58.4 ± 2.0 | 63.0 ± 2.1 | 0.195 | 5,740 | 6,290 |
| 3 × 120 (6/10kV TPYC/Y) | 37 / 2.03 | 14.21 | 62.3 ± 2.1 | 67.1 ± 2.2 | 0.154 | 6,750 | 7,360 |
| 3 × 150 (6/10kV TPYC/Y) | 37 / 2.25 | 15.75 | 65.9 ± 2.2 | 70.7 ± 2.3 | 0.126 | 7,790 | 8,440 |
Selection guide: Specify JIS C 3410 3.6/6 kV or 6/10 kV, designation (SPYCB, SPYCBY, FA-SPYCB, FA-SPYCBY, TPYC, TPYCY, FA-TPYC, or FA-TPYCY), cross-section (10–300 mm²), and optional Cold Type (C).
Ordering & Quotation Checklist: Request a factory quotation for JIS C 3410 (2010) 3.6/6 kV or 6/10 kV (FA-)SPYCB, (FA-)SPYCBY, (FA-)TPYC, or (FA-)TPYCY medium-voltage marine power cables.
JIS C 3410 DPYC, TPYC, MPYC & TTYC / TTYCS Marine Shipboard Cable
JIS C 3410 (Aligned with IEC 60092-353 & IEC 60092-376)
RFCU 3.6/6–18/30 kV GSWB & RFOU 18/30 kV (P20/P22/P113) Offshore Cable
RFCU (3.6/6–18/30 kV GSWB Armor) & RFOU / RFOU M 18/30(36) kV (P20/P22/P113)
00/12/FO2, RMP200 & 6XM524 Pipe Crawler & C-3400 / 26XM520 Cleaning Robot Cable
00/12/FO2, 00/20/FOX2 (Electro-Optical), 524/11 (11-Core Copper), RMP200 / RMP300 / RMP350 / RMP500, 6XM524, 1HRS347
Request Quotation & Datasheet for This Cable
Need factory pricing, cross-section drawing or a full PDF datasheet for JIS C 3410 3.6/6 kV & 6/10 kV SPYCB / TPYCY MV Marine Power Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.
- ISO 9001 Factory Direct
- MOQ 50 m (Custom Builds)
- 24h Engineering Reply