Type LSX 1C Armored & Sheathed 1kV / 2kV Offshore Rig Power Cable (IEEE 1580)

Type LSX Single Conductor Armored & Sheathed (1 kV & 2 kV) is a heavy-duty, low-smoke zero-halogen (LSZH) marine and offshore rig power feeder cable engineered to IEEE 1580 and UL 1309. Designed for high-current AC and DC bus feeders on offshore.

  • Cable DesignationType LSX Single Conductor Armored & Sheathed (1 kV & 2 kV Rated)
  • Voltage Rating1,000 V (1 kV Series) and 2,000 V (2 kV Series)
  • Conductor Range16 AWG (2.6 mm²) to 1111 MCM / kcmil (563 mm²) Stranded Tinned Copper (ASTM B33 / B172)
  • Primary Insulation110°C Rated Low-Smoke Zero-Halogen Cross-Linked Polyolefin (Type LSX)
  • Metallic ArmorBraided Bronze or Tinned Copper Basket-Weave Armor per IEEE 1580 / UL 1309
  • Outer SheathMud-Resistant, Oil-Resistant, Flame-Retardant LSZH Cross-Linked Polyolefin
  • Temperature Range-40°C Cold Bend / -55°C Cold Impact to +110°C Continuous (+130°C Emergency Overload)
  • Supply FormatCustom Cut Lengths, Export Wooden Drums, and OEM Harnessing
Category:

Type LSX Single Conductor Armored & Shipboard & Offshore Identification

  • Type: Marine & Offshore Cables
  • Cable Designation: Type LSX Single Conductor Armored & Sheathed (1 kV & 2 kV Rated
  • Voltage Rating: 1,000 V (1 kV Series) and 2,000 V (2 kV Series
  • Conductor Range: 16 AWG (2.6 mm²) to 1111 MCM / kcmil (563 mm²) Stranded Tinned Copper (ASTM B33 / B172

Marine Electrical, Temperature & Bend Ratings

  • Primary Insulation: 110°C Rated Low-Smoke Zero-Halogen Cross-Linked Polyolefin (Type LSX
  • Metallic Armor: Braided Bronze or Tinned Copper Basket-Weave Armor per IEEE 1580 / UL 1309
  • Outer Sheath: Mud-Resistant, Oil-Resistant, Flame-Retardant LSZH Cross-Linked Polyolefin
  • Temperature Range: -40°C Cold Bend / -55°C Cold Impact to +110°C Continuous (+130°C Emergency Overload
  • Supply Format: Custom Cut Lengths, Export Wooden Drums, and OEM Harnessing

Type LSX Single Conductor Armored & Halogen-Free / Armored Architecture

Type LSX Single Conductor Armored & Sheathed cables are built to survive mechanical vibration, drilling fluid immersion, and Arctic cold aboard offshore units.

  • Conductor: Soft annealed tinned copper, fine-stranded rope-lay construction per ASTM B33 and ASTM B172 (16 AWG through 1111 MCM).
  • Separator Tape: Helically applied synthetic separator tape facilitating clean conductor stripping for compression lugs.
  • Insulation: Extruded 110°C rated flame-retardant, low-smoke zero-halogen cross-linked polyolefin meeting IEEE 1580 Type LSX (1 kV or 2 kV wall thickness).
  • Bedding / Inner Barrier: Protective tape wrap under the metallic braid.
  • Braided Armor: Non-magnetic bronze wire braid (or tinned copper braid on request) applied with >= 88% optical coverage per IEEE 1580 / UL 1309.
  • Outer Sheath: Black, mud-resistant, oil-resistant, sunlight-resistant LSZH cross-linked polyolefin thermoset jacket.

Shipboard Fire Integrity & EMC Performance

  • Voltage Classes: 1 kV & 2 kV Single Conductor
  • Size Range: 16 AWG to 1111 MCM (Tinned Cu
  • Armor Construction: IEEE 1580 Braided Bronze / Tinned Cu
  • Thermal Rating: -40°C to +110°C (LSZH Mud-Resistant

Salt Fog, Mud, Oil & Low-Smoke Resistance

  • 110°C Rated Type LSX Cross-Linked Polyolefin:: Delivers higher continuous ampacity than 90°C IEC shipboard cables, allowing smaller conductor gauges and reduced topside weight in congested offshore cable trays.
  • Non-Magnetic Braided Bronze Armor:: Provides rugged mechanical crush and abrasion resistance per IEEE 1580 / UL 1309 without inducing single-core AC eddy-current heating.
  • Full 1 kV & 2 kV Rig Gauge Schedule (16 AWG to 1111 MCM):: Covers locomotive/rig DLO stranding sizes including 262 MCM, 313 MCM, 373 MCM, 444 MCM, 535 MCM, 646 MCM, 777 MCM, and 1111 MCM.
  • Zero-Halogen Flame & Arctic Cold Performance:: Meets IEEE 1202 / FT4 and IEC 60332-3-22 Cat. A vertical tray flame tests alongside CSA C22.2 No. 0.3 cold bend (-40°C) and cold impact (-55°C).

IEC 60092 / NEK 606 / BS Marine Standards

  • IEEE 1580 & UL 1309: Recommended practice and construction standard for marine and offshore shipboard cables (Type LSX 110°C cross-linked polyolefin).
  • ASTM B33 & ASTM B172: Soft annealed tinned copper rope-lay flexible conductors (Class I / Class K stranding).
  • IEEE 1202 / FT4 & IEC 60332-3-22 Cat. A: Vertical cable tray flame propagation compliance.
  • IEC 60754-1/2 & IEC 61034-1/2: Zero-halogen acid gas (< 0.5%) and low smoke density verification.

Marine & Offshore Cable Engineering Guides

Offshore oil and gas platform equipped with Type LSX single conductor armored 1kV and 2kV power feeders
Type LSX Single Conductor Armored and Sheathed 1 kV and 2 kV cables deliver high-ampacity, halogen-free power distribution for offshore drilling draw-works, mud pumps, and topside propulsion buses. Photo: Dave Fergusson, CC BY-SA 2.0.

Type LSX Single Conductor Armored & Vessel, Platform & FPSO Routing

Type LSX Single Conductor Armored & Sheathed (1 kV & 2 kV) is a heavy-duty, low-smoke zero-halogen (LSZH) marine and offshore rig power feeder cable engineered to IEEE 1580 and UL 1309. Designed for high-current AC and DC bus feeders on offshore jack-up rigs, semi-submersibles, drillships, and FPSO topside modules, this single-conductor armored construction combines fine-stranded soft annealed tinned copper conductors (ASTM B33 / B172) with 110°C cross-linked polyolefin Type LSX insulation, an IEEE 1580 braided bronze or tinned copper armor, and an outer mud- and oil-resistant LSZH protective jacket.

Compared with conventional Type P thermoset cables, Type LSX Armored & Sheathed eliminates halogenated acid gas emissions during a shipboard fire (IEC 60754-1/2 < 0.5% halogen content) and maintains superior visibility in enclosed engine rooms and living quarters (IEC 61034 smoke transmittance). Because single-conductor power feeders carry 300 A to over 1,000 A per phase in parallel tray formations, non-magnetic bronze or tinned copper basket-weave armor is used to prevent eddy-current heating losses. We manufacture both the 1 kV (1,000 V) and 2 kV (2,000 V) Type LSX Single Conductor Armored & Sheathed series across the full North American rig gauge schedule from 16 AWG up to 1111 MCM (563 mm²). For unarmored multi-core or single-core Type LSX constructions, see ourType LSX 600V/1kV/2kV LSZH Offshore Rig Cable, or explore NEK 606 mud-resistantBFOU / RFOU 0.6/1kV Offshore Cablesand UK-sectorBS 6883 / BS 7917 UKOOA Offshore Power Cables.

Shipboard Systems & Offshore Zone Coverage

  • High-horsepower offshore drilling equipment—including top drives, mud pumps, drawworks, dynamic positioning (DP) thrusters, and main generator tie-breakers—requires parallel single-conductor 1 kV and 2 kV cables routed through open ladder racks and bulkhead penetrations. Mechanical impact protection is critical in exposed rig areas, while magnetic steel wire armor cannot be used on single-core AC feeders due to inductive hysteresis heating.
  • Type LSX Single Conductor Armored & Sheathed solves both challenges by applying a high-coverage non-magnetic bronze wire braid between the Type LSX cross-linked polyolefin insulation and the outer LSZH thermoset sheath. The outer jacket resists ester-based and calcium-bromide drilling muds, diesel fuel, hydraulic oils, and North Sea / Arctic cold impact down to -55°C.

Type LSX Single Conductor Armored & Marine & Offshore Technical FAQ

Why does single-conductor Type LSX Armored cable use bronze braid instead of galvanized steel wire braid?

When alternating current flows through a single-conductor cable, it generates a concentric alternating magnetic field. If a magnetic armor like galvanized steel is used on a single-core cable, severe eddy currents and hysteresis losses heat the armor and derate the cable. Non-magnetic bronze braid eliminates magnetic heating while delivering full IEEE 1580 mechanical protection.

What is the difference between the LSX-1-BS (1 kV) and LSX-2KV-BS (2 kV) series?

Both series share identical ASTM B172 tinned copper conductor stranding, bronze braid armor, and 110°C thermal ratings, but the 2 kV series features a thicker primary Type LSX insulation wall (for example, 0.090 in vs. 0.072 in on 4/0 AWG) to support 2,000 V AC/DC propulsion, VFD, and drilling drive buses.

How does Type LSX compare to Type P (IEEE 1580) single-conductor armored cable?

Both use identical AWG/MCM conductor stranding (such as 535 MCM, 646 MCM, and 777 MCM) and fit the same offshore compression lugs and cable glands. However, Type LSX replaces halogenated CPE/CSP outer sheaths with low-smoke zero-halogen (LSZH) cross-linked polyolefin.

Can Type LSX 1C Armored & Sheathed be used in VFD / SCR mud pump and drawworks drives?

Yes. The 2 kV (2,000 V) Type LSX Single Conductor Armored & Sheathed series is widely deployed for 690 V and 1,000 V AC variable frequency drive (VFD) and DC SCR traction buses where the braided bronze armor is bonded at both ends as a high-frequency EMI return shield.

Complete dimensional, weight, and 100°C / 110°C ampacity data below are extracted from TEBAOFLEX datasheets #29 (Type LSX 1C Armored & Sheathed 2 kV) and #30 (Type LSX 1C Armored & Sheathed 1 kV).

TEBAOFLEX® — Type LSX Single Conductor Armored & Sheathed — 1 kV (1,000 V) Series (Datasheet #30)

Type LSX Single Conductor Armored & Sheathed — 1 kV (1,000 V) Series (Datasheet #30)
Part No. Conductor Size (AWG / MCM) Stranding (No. × AWG) Nom. Insulation Thickness Nom. Outer Dia. (in / mm) Approx. Weight (lbs/Mft / kg/km) Ampacity (100°C / 110°C, 45°C Amb.)
LSX14-1-BS 14 AWG 19 / 27 0.045 in (1.14 mm) 0.335 in (8.5 mm) 89 lbs / 132 kg 38 A / 41 A
LSX8-1-BS 8 AWG 37 / 24 0.055 in (1.40 mm) 0.431 in (10.9 mm) 156 lbs / 232 kg 84 A / 91 A
LSX2-1-BS 2 AWG 150 / 24 0.055 in (1.40 mm) 0.601 in (15.3 mm) 398 lbs / 592 kg 199 A / 214 A
LSX1/0-1-BS 1/0 AWG 275 / 24 0.072 in (1.83 mm) 0.735 in (18.7 mm) 630 lbs / 938 kg 271 A / 292 A
LSX4/0-1-BS 4/0 AWG 550 / 24 0.072 in (1.83 mm) 0.955 in (24.3 mm) 1,073 lbs / 1,597 kg 425 A / 458 A
LSX313-1-BS 313 MCM 777 / 24 0.082 in (2.08 mm) 1.088 in (27.6 mm) 1,497 lbs / 2,228 kg 538 A / 580 A
LSX444-1-BS 444 MCM 1110 / 24 0.082 in (2.08 mm) 1.242 in (31.5 mm) 1,953 lbs / 2,906 kg 695 A / 749 A
LSX535-1-BS 535 MCM 1332 / 24 0.090 in (2.29 mm) 1.348 in (34.2 mm) 2,320 lbs / 3,453 kg 789 A / 850 A
LSX646-1-BS 646 MCM 1591 / 24 0.090 in (2.29 mm) 1.464 in (37.2 mm) 2,677 lbs / 3,984 kg 897 A / 967 A
LSX777-1-BS 777 MCM 1924 / 24 0.090 in (2.29 mm) 1.556 in (39.5 mm) 3,146 lbs / 4,682 kg 1,004 A / 1,082 A
LSX1111-1-BS 1111 MCM 2745 / 24 0.115 in (2.92 mm) 1.872 in (47.5 mm) 4,619 lbs / 6,874 kg 1,237 A / 1,333 A

TEBAOFLEX® — Type LSX Single Conductor Armored & Sheathed — 2 kV (2,000 V) Series (Datasheet #29)

Type LSX Single Conductor Armored & Sheathed — 2 kV (2,000 V) Series (Datasheet #29)
Part No. Conductor Size (AWG / MCM) Stranding (No. × AWG) Nom. Insulation Thickness Nom. Outer Dia. (in / mm) Approx. Weight (lbs/Mft / kg/km) Ampacity (100°C / 110°C, 45°C Amb.)
LSX14-2KV-BS 14 AWG 19 / 27 0.060 in (1.52 mm) 0.391 in (9.9 mm) 106 lbs / 158 kg 38 A / 41 A
LSX4-2KV-BS 4 AWG 105 / 24 0.070 in (1.78 mm) 0.558 in (14.2 mm) 335 lbs / 499 kg 152 A / 164 A
LSX1/0-2KV-BS 1/0 AWG 275 / 24 0.090 in (2.29 mm) 0.785 in (19.9 mm) 654 lbs / 973 kg 271 A / 292 A
LSX4/0-2KV-BS 4/0 AWG 550 / 24 0.090 in (2.29 mm) 0.975 in (24.8 mm) 1,148 lbs / 1,708 kg 425 A / 458 A
LSX373-2KV-BS 373 MCM 925 / 24 0.090 in (2.29 mm) 1.196 in (30.4 mm) 1,745 lbs / 2,597 kg 617 A / 665 A
LSX535-2KV-BS 535 MCM 1332 / 24 0.090 in (2.29 mm) 1.348 in (34.2 mm) 2,320 lbs / 3,453 kg 789 A / 850 A
LSX646-2KV-BS 646 MCM 1591 / 24 0.105 in (2.67 mm) 1.480 in (37.6 mm) 2,801 lbs / 4,168 kg 897 A / 967 A
LSX777-2KV-BS 777 MCM 1924 / 24 0.105 in (2.67 mm) 1.589 in (40.4 mm) 3,267 lbs / 4,862 kg 1,004 A / 1,082 A
LSX1111-2KV-BS 1111 MCM 2745 / 24 0.145 in (3.68 mm) 1.946 in (49.4 mm) 4,598 lbs / 6,843 kg 1,237 A / 1,333 A

Selection guide: Single-conductor ampacities are calculated per IEEE 45 / IEEE 1580 for a 45°C marine ambient temperature. Minimum installation bending radius is 8 × overall cable diameter for armored Type LSX constructions. CompareJIS C 3410 DPYC, TPYC, MPYC, and TTYC marine shipboard cablesand(N)TMCHXOEU, (N)TSCGEHXOEU, and (N)TMCGC11Y medium-voltage rubber cables.

Ordering & Quotation Checklist: Provide your required voltage rating (1 kV or 2 kV), conductor gauge (16 AWG to 1111 MCM), armor material (bronze or tinned copper braid), and footage for an immediate rig-grade quotation.

00/12/FO2, RMP200 & 6XM524 Pipe Crawler & C-3400 / 26XM520 Cleaning Robot Cable

00/12/FO2, RMP200 & 6XM524 Pipe Crawler & C-3400 / 26XM520 Cleaning Robot Cable

00/12/FO2, 00/20/FOX2 (Electro-Optical), 524/11 (11-Core Copper), RMP200 / RMP300 / RMP350 / RMP500, 6XM524, 1HRS347

VIEW PRODUCT »

1G7Z1-R 0.6/1 kV HEPR G7 Insulated SHF1 LSZH Shipboard Power & Control Cable

29501-29507 (300% Ground), 29521-29527, A220 & Series 3568 (600/1000V) VFD Cable

29501-29507 (300% Ground), 29521-29527, A220 & Series 3568 (600/1000V) VFD Cable

29500–29507 (300% Ground 4C+Drain), 29521–29532 (Symmetrical 3C+3G), A220 (Class K 1kV) & Series 3568 (XLPE TR)

VIEW PRODUCT »

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for Type LSX 1C Armored & Sheathed 1kV / 2kV Offshore Rig Power Cable (IEEE 1580)? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.

  • ISO 9001 Factory Direct
  • MOQ 50 m (Custom Builds)
  • 24h Engineering Reply
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    Type LSX 1C Armored & Sheathed 1kV / 2kV Offshore Rig Power Cable (IEEE 1580)Get A Quote