600V/1000V Type TC-ER-HL Polymeric-Armored VFD & Oil & Gas Power Cable
UL Type TC-ER-HL 600V and UL Type TC-ER 1000V Polymeric-Armored Chemical-Barrier VFD Motor, Power, Control and Instrumentation Cables (14 AWG to 750 kcmil) replace conventional metallic interlocked/welded armor (Type MC-HL) in petrochemical refineries, LNG terminals, pulp & paper mills, and NEC Class I Division 1 / Zone 1 hazardous locations. Featuring 90 °C XHHW-2 XLPE cores, symmetrical grounds.
- Model designationsType TC-ER-HL 600V / Type TC-ER 1000V Polymeric-Armored VFD, Power & Control
- Reference standardsUL 1277, UL 2225 (Crush/Impact HL), ICEA S-95-658 / NEMA WC70, NEC Art. 336 / 501 / 505
- Rated voltage600 V (UL Type TC-ER-HL) & 1000 V (UL Type TC-ER); 0.6/1 kV IEC
- Conductor & ground14 AWG–750 kcmil Class B/C bare Cu (ASTM B3/B8) + 3 symmetrical tinned/bare Cu grounds
- Insulation90 °C wet/dry flame-retardant XHHW-2 XLPE (VW-1 rated, ICEA Method 4 coding)
- EMC shield & chemical barrier100% aluminum/polymer laminate or dual helical copper tape shield + hydrocarbon barrier
- Polymeric armor & jacketCo-extruded high-modulus polymeric impact/crush armor + lead-free PVC or LSZH (-40 °C cold impact)
- Flame & hazardous ratingsUL 1685 / IEEE 1202 / CSA FT4; NEC Class I, II, III Div. 1 & 2 and Zone 1 & 2
UL Type TC-ER-HL 600V / TC-ER 1000V Drive & Motor Cable Identification
- Type: Oil & Gas Cable
- Model designations: Type TC-ER-HL 600V / Type TC-ER 1000V Polymeric-Armored VFD, Power & Control
- Reference standards: UL 1277, UL 2225 (Crush/Impact HL), ICEA S-95-658 / NEMA WC70, NEC Art. 336 / 501 / 505
- Rated voltage: 600 V (UL Type TC-ER-HL) & 1000 V (UL Type TC-ER); 0.6/1 kV IEC
PWM Inverter Voltage, Thermal & Bend Ratings
- Conductor & ground: 14 AWG–750 kcmil Class B/C bare Cu (ASTM B3/B8) + 3 symmetrical tinned/bare Cu grounds
- Insulation: 90 °C wet/dry flame-retardant XHHW-2 XLPE (VW-1 rated, ICEA Method 4 coding
- EMC shield & chemical barrier: 100% aluminum/polymer laminate or dual helical copper tape shield + hydrocarbon barrier
- Polymeric armor & jacket: Co-extruded high-modulus polymeric impact/crush armor + lead-free PVC or LSZH (-40 °C cold impact
- Flame & hazardous ratings: UL 1685 / IEEE 1202 / CSA FT4; NEC Class I, II, III Div. 1 & 2 and Zone 1 & 2
UL Type TC-ER-HL 600V / TC-ER 1000V Low-Capacitance & Dual-Screen Build
By co-extruding a high-modulus polymeric crush/impact armor over a bonded aluminum/polymer chemical barrier, Type TC-ER-HL cables outperform metallic interlocked armor in corrosive refinery environments.
- Conductors: Annealed bare copper per ASTM B3: Class C stranding (14–6 AWG) and Class B stranding (4 AWG–750 kcmil) per ASTM B8.
- Insulation: Flame-retardant 90 °C wet/dry XHHW-2 cross-linked polyethylene (XLPE), VW-1 rated, ICEA Method 4 color-coded.
- Grounds & Fillers: VFD & Power: three (3) symmetrical tinned or bare copper grounds per NEC Table 250.122; Control: one (1) green insulated ground; solid elastomeric fillers.
- EMC Shield / Chemical Barrier: 100% aluminum/polymer laminate (or dual helical copper tapes) in contact with ground wires, serving as both EMC shield and radial hydrocarbon barrier.
- Polymeric Armor & Jacket: High-strength co-extruded polymeric crush/impact armor layer + sunlight/oil-resistant lead-free PVC or LSZH outer jacket.
EMC Transfer Impedance & Bearing Current Control
- Exceeds Type MC-HL crush & impact resistance: Co-extruded high-modulus polymeric armor layer passes UL 2225 hazardous-location crush and impact tests without metallic armor corrosion or spring-back.
- NEC Class I Div. 1 / Zone 1 TC-ER-HL rated: Approved for exposed runs (ER) between cable trays and utilization equipment in Class I, II, and III Division 1 & 2 hazardous locations per NEC Art. 336 & 501.
- Symmetrical 3-ground VFD EMC geometry: Three balanced stranded tinned copper ground wires + 100% overall shield cancel electromagnetic interference and eliminate motor bearing fluting.
- Integrated hydrocarbon & chemical barrier: Laminated aluminum/polymer barrier bonded beneath the polymeric armor blocks benzene, toluene, xylene, acids, and caustic refinery soil contaminants.
Industrial Oil, Vibration & Plant Routing Durability
- 90 °C wet/dry XHHW-2 VW-1 conductors: Flame-retardant cross-linked polyethylene (XLPE) insulation meets NEC Type XHHW-2 (90 °C wet or dry) and individual conductor VW-1 vertical flame tests.
- -25 °C / -40 °C cold-bend & cold-impact rating: Lead-free sunlight- and oil-resistant PVC (or optional LSZH) outer jacket meets -25 °C to -40 °C Arctic cold-bend and CSA -35 °C cold-impact testing.
- Exposed Run (ER) without conduit: Drops directly from cable tray to motor terminal boxes up to 6 ft (1.8 m) unsupported without requiring intermediate rigid metal conduit.
- Built-in nylon ripcord for fast stripping: Every cable with a jacket thickness of 60 mils or less incorporates a high-tensile ripcord for clean, nick-free outer sheath removal.
IEC / VDE / UL Variable-Frequency Drive Standards
- UL 1277 & UL 2225: Type TC-ER-HL 600V for Hazardous Locations & Type TC-ER 1000V Crush/Impact Compliance
- ICEA S-95-658 / NEMA WC70: Power cables rated 2000 V or less for the distribution of electrical energy
- NEC Articles 336, 501, 502, 503, 505 & 725: Class I, II, III Divisions 1 & 2 and Class I Zones 1 & 2
- UL 1685 / IEEE 1202 / CSA C22.2 No. 0.3 FT4: -40 °C Cold Bend / -35 °C Cold Impact & Vertical Tray Flame Test
VFD, Servo & EMC Earthing Guides

UL Type TC-ER-HL 600V / TC-ER 1000V Inverter-Fed Motor & Drive Integration
In North American and international petrochemical refineries, onshore LNG liquefaction trains, chemical plants, and offshore topsides, traditional metallic interlocked armor (AIA / SWA) and continuous welded corrugated aluminum (Type MC-HL) cables suffer from galvanic corrosion, jacket-splitting moisture ingress, larger bending radii, and expensive hazardous-location gland terminations. Our UL Type TC-ER-HL 600V / Type TC-ER 1000V Polymeric-Armored Cable System replaces metallic armor with a co-extruded high-strength polymeric impact/crush-absorbing armor layer (Air-Bag polymeric armor) combined with a longitudinally bonded aluminum/polymer chemical barrier. This non-metallic armored construction exceeds the crush and impact test requirements of UL 2225 Type MC-HL cables, bends at just 6 × to 8 × OD, weighs up to 30% less than metallic-armored cables, and terminates rapidly with standard hazardous-location polymeric cable glands.
For pulse-width-modulated (PWM) inverter drives in NEC Class I, II, and III, Division 1 & 2 (and Class I, Zone 1 & 2) hazardous areas, the 3-Conductor Polymeric-Armored VFD Motor Cable (14 AWG through 750 kcmil) integrates three (3) symmetrical stranded tinned copper ground conductors sized to NEC Table 250.122 and a 100% coverage aluminum/polymer or dual copper-tape shield in continuous contact with the ground wires to drain common-mode shaft currents. For standard 2000 V tray VFD applications, compare our2000V TC-ER Shielded VFD Motor Cable, or for European SWA-armored refinery power seeFG16OR16FR16 0.6/1 kV Armored Hydrocarbon-Resistant CableandRHVhMVh 3.6/6–18/30 kV SWA Refinery MV Cable.
Typical Variable-Speed Drive Installations
- Hazardous-Location VFD Motor Feeders (14 AWG to 750 kcmil 3/C + 3 Symmetrical Grounds): Supplies PWM inverter-fed centrifugal pumps, gas compressors, cooling-tower fans, and mixers in NEC Class I Division 1 / Zone 1 petrochemical process units, direct-buried trenches, concrete ducts, and open ladder trays.
- Refinery & LNG Multi-Conductor Power, Control & Instrumentation (14 AWG to 750 kcmil Power; 2C to 37C #14 / #12 Control): Provides corrosion-proof, rodent-resistant, and chemical-impervious power and control distribution across coastal LNG terminals, sour-gas plants, and pulp & paper bleach plants.
UL Type TC-ER-HL 600V / TC-ER 1000V VFD Screening & Termination FAQ
How can a non-metallic polymeric-armored cable qualify for NEC Class I Division 1 / Zone 1 (Type TC-ER-HL)?
Under UL 1277 and UL 2225, Type TC-ER-HL cables must pass the same severe mechanical crush and impact tests required of metallic-armored Type MC-HL cables. The co-extruded high-modulus polymeric armor layer absorbs impact energy and resists crushing without metallic armor.
Why use polymeric armor + chemical barrier instead of Galvanized Steel Wire Armor (SWA) or Interlocked Aluminum Armor (AIA) in refineries?
In coastal refineries, sour-gas units, and chemical plants, moisture and corrosive vapors penetrate beneath interlocked metal armor, corroding the metal and allowing benzene/hydrocarbons to attack the core insulation. A continuous polymeric armor bonded to an aluminum/polymer chemical barrier eliminates metal corrosion and blocks hydrocarbon permeation.
Why do the 3/C VFD cables use three (3) symmetrical tinned copper grounds?
Splitting the equipment grounding conductor into three equal tinned copper wires placed symmetrically in the three core interstices balances phase-to-ground capacitance and provides a low-inductance return path for high-frequency IGBT switching currents.
Is Type TC-ER-HL approved for direct burial as well as cable tray and exposed runs?
Yes. It is rated for indoor/outdoor cable trays, exposed runs (ER) from tray to equipment, underground ducts, direct burial, concrete encasement, and aerial messenger installations.
Dimensional, ground-conductor, weight and ampacity specifications for 600V Type TC-ER-HL / 1000V Type TC-ER polymeric-armored 3/C VFD motor cables and multi-core oil & gas power/control cables (14 AWG to 750 kcmil).
TEBAOFLEX® — 600V/1000V Type TC-ER-HL Polymeric-Armored VFD & Oil & Gas Power Cable
| Circuit Size (3/C AWG/kcmil) | XHHW-2 Insulation (mils / mm) | Symmetrical Grounds (3 × AWG) | Jacket Thickness (mils / mm) | Nominal Overall OD (in / mm) | Approx. Net Weight (lbs/kft / kg/km) | 90 °C NEC Ampacity (A) |
|---|---|---|---|---|---|---|
| 3/C #14 AWG | 30 / 0.76 | 3 × #18 AWG Tinned Cu | 60 / 1.52 | 0.54 / 13.7 | 167 / 249 | 25 |
| 3/C #12 AWG | 30 / 0.76 | 3 × #16 AWG Tinned Cu | 60 / 1.52 | 0.58 / 14.7 | 208 / 310 | 30 |
| 3/C #10 AWG | 30 / 0.76 | 3 × #14 AWG Tinned Cu | 60 / 1.52 | 0.63 / 16.0 | 269 / 400 | 40 |
| 3/C #8 AWG | 45 / 1.14 | 3 × #14 AWG Tinned Cu | 60 / 1.52 | 0.77 / 19.6 | 386 / 574 | 55 |
| 3/C #6 AWG | 45 / 1.14 | 3 × #12 AWG Tinned Cu | 80 / 2.03 | 0.89 / 22.6 | 560 / 833 | 75 |
| 3/C #4 AWG | 45 / 1.14 | 3 × #12 AWG Tinned Cu | 80 / 2.03 | 0.97 / 24.6 | 729 / 1,085 | 95 |
| 3/C #2 AWG | 45 / 1.14 | 3 × #10 AWG Tinned Cu | 80 / 2.03 | 1.10 / 27.9 | 1,027 / 1,528 | 130 |
| 3/C #1 AWG | 55 / 1.40 | 3 × #10 AWG Tinned Cu | 80 / 2.03 | 1.21 / 30.7 | 1,235 / 1,838 | 145 |
| 3/C 1/0 AWG | 55 / 1.40 | 3 × #10 AWG Tinned Cu | 80 / 2.03 | 1.29 / 32.8 | 1,473 / 2,192 | 170 |
| 3/C 2/0 AWG | 55 / 1.40 | 3 × #10 AWG Tinned Cu | 80 / 2.03 | 1.40 / 35.6 | 1,771 / 2,636 | 195 |
| 3/C 3/0 AWG | 55 / 1.40 | 3 × #8 AWG Tinned Cu | 80 / 2.03 | 1.48 / 37.6 | 2,178 / 3,241 | 225 |
| 3/C 4/0 AWG | 55 / 1.40 | 3 × #8 AWG Tinned Cu | 80 / 2.03 | 1.61 / 40.9 | 2,651 / 3,945 | 260 |
| 3/C 250 kcmil | 65 / 1.65 | 3 × #8 AWG Tinned Cu | 110 / 2.79 | 1.83 / 46.5 | 3,179 / 4,731 | 290 |
| 3/C 350 kcmil | 65 / 1.65 | 3 × #6 AWG Tinned Cu | 110 / 2.79 | 2.05 / 52.1 | 4,283 / 6,374 | 350 |
| 3/C 500 kcmil | 65 / 1.65 | 3 × #6 AWG Tinned Cu | 110 / 2.79 | 2.34 / 59.4 | 5,890 / 8,765 | 430 |
TEBAOFLEX® — 600V/1000V Type TC-ER-HL Polymeric-Armored VFD & Oil & Gas Power Cable
| Cable Application | Formation (Cores × AWG) | Ground Conductor | Chemical Barrier | Nominal OD (in / mm) | Approx. Weight (lbs/kft / kg/km) | Cold Bend / Impact Rating |
|---|---|---|---|---|---|---|
| LV Control Cable | 4/C #14 AWG + 1G | 1 × #14 Green Insulated | Bonded Al/Polymer + Polymeric Armor | 0.52 / 13.2 | 145 / 216 | -40 °C / -35 °C |
| LV Control Cable | 7/C #14 AWG + 1G | 1 × #14 Green Insulated | Bonded Al/Polymer + Polymeric Armor | 0.61 / 15.5 | 215 / 320 | -40 °C / -35 °C |
| LV Control Cable | 12/C #14 AWG + 1G | 1 × #14 Green Insulated | Bonded Al/Polymer + Polymeric Armor | 0.76 / 19.3 | 335 / 499 | -40 °C / -35 °C |
| LV Control Cable | 19/C #14 AWG + 1G | 1 × #14 Green Insulated | Bonded Al/Polymer + Polymeric Armor | 0.88 / 22.4 | 485 / 722 | -40 °C / -35 °C |
| LV Control Cable | 37/C #14 AWG + 1G | 1 × #14 Green Insulated | Bonded Al/Polymer + Polymeric Armor | 1.16 / 29.5 | 870 / 1,295 | -40 °C / -35 °C |
| LV Power Feeder | 3/C #2/0 AWG + 3G | 3 × #10 Bare Cu | Bonded Al/Polymer + Polymeric Armor | 1.38 / 35.1 | 1,740 / 2,589 | -40 °C / -35 °C |
| LV Power Feeder | 3/C 500 kcmil + 3G | 3 × #6 Bare Cu | Bonded Al/Polymer + Polymeric Armor | 2.32 / 58.9 | 5,810 / 8,646 | -40 °C / -35 °C |
| LV Power Feeder | 3/C 750 kcmil + 3G | 3 × #4 Bare Cu | Bonded Al/Polymer + Polymeric Armor | 2.76 / 70.1 | 8,490 / 12,635 | -40 °C / -35 °C |
Selection guide: Specify VFD (with 100% EMC shield + 3 symmetrical tinned copper grounds) or Power/Control (with chemical barrier), AWG/kcmil size (14 AWG to 750 kcmil), core count, and PVC or LSZH outer jacket. For metallic Continuous Corrugated Welded (CCW) Aluminum UL 2225 Type MC-HL VFD cables, -40 °C CPE Class K Type TC-ER-HL control/instrumentation cables, and 2000V RHH/RHW-2 symmetrical VFD feeders, see600V/1000V Type MC-HL CCW Armored LSZH VFD & Type TC-ER-HL (-40 °C CPE) Cableand2400V Type MV-90 LSZH Traction Power & 2000V Symmetrical VFD TC-ER Cable. For 2,000 V IEEE 1580 Type P / UL 2225 Type TC-ER-HL crush-resistant 37-102 CIRVA2 VFD cables, 37-108VFD / 37-600VFD / 37-000VFD refinery VFD feeders, and 37-105VFD (5–15 kV) medium-voltage offshore VFD cables, see37-102 CIRVA2 (2kV TC-ER-HL), 37-108VFD, 37-600VFD & 37-000VFD Industrial VFD Cableand37-105VFD & Type MMV-VFD (5kV / 8kV / 15kV) Marine & Offshore MV VFD Cable.
Ordering & Quotation Checklist: Request a factory quotation for UL Type TC-ER-HL 600V / Type TC-ER 1000V polymeric-armored VFD motor and oil & gas power/control cables (14 AWG to 750 kcmil).
2000 V TC-ER Shielded VFD Motor Cable
Fixed industrial drive and motor connections requiring a 2000 V TC-ER classification, including appropriately
FG16OR16FR16 0.6/1 kV SWA Armored Hydrocarbon-Resistant HEPR Cable
FG16OR16FR16 0.6/1 kV (CU / HEPR G16 / PVC R16 / SWA+CS / PVC R16 HC)
RHVhMVh 3x Cu + H1 3.6/6–18/30 kV SWA Armored Hydrocarbon-Resistant MV Cable
RHVhMVh 3x Cu + H1 (Three-Core Screened & SWA Armored MV Cable)
Request Quotation & Datasheet for This Cable