0.6/1 kV F-RFOU Offshore VFD Motor Cable
Fixed offshore drive-to-motor connections with a specified EMC screen and motor-circuit design. Selected rated voltage: 0.6/1 kV Representative configuration: 3 × 50/25 mm² phase/braid schedule Representative OD /mass: 34.7 mm /2700 kg/km Representative minimum bend radius: 209 mm Representative resistance at 20°C: 0.393 Ω/km
- Selected rated voltage0.6/1 kV
- Representative configuration3 × 50/25 mm² phase/braid schedule
- Representative OD /mass34.7 mm /2700 kg/km
- Representative minimum bend radius209 mm
- Representative resistance at 20°C0.393 Ω/km
- Representative current at 45°C free air167 A
- Conductor classClass 5 tinned copper
- F-RFOU 0.6/1 kV VFDSelected Class 5 foil/braid design and size table.
0.6/1 kV F-RFOU Offshore VFD Motor Cable Shipboard & Offshore Identification
- Type: Industrial Cables
- Selected rated voltage: 0.6/1 kV
- Representative configuration: 3 × 50/25 mm² phase/braid schedule
- Representative OD /mass: 34.7 mm /2700 kg/km
Marine Electrical, Temperature & Bend Ratings
- Representative minimum bend radius: 209 mm
- Representative resistance at 20°C: 0.393 Ω/km
- Representative current at 45°C free air: 167 A
- Conductor class: Class 5 tinned copper
- F-RFOU 0.6/1 kV VFD: Selected Class 5 foil/braid design and size table.
0.6/1 kV F-RFOU Offshore VFD Motor Cable Halogen-Free / Armored Architecture
- Conductors: Class 5 multibunch tinned copper.
- Insulation: HF-HEPR on three phase cores.
- Inner covering: Halogen-free compound.
- Screens: Copper/polyester foil plus separate tinned-copper braid.
- Sheath: SHF2 or explicitly selected SHF MUD.
Select the complete construction
The copper foil, tinned braid, inner covering and three insulated phase cores are separate layers. The /25 field on 3 × 50/25 is braid area. The selected geometry does not add three insulated PE cores, and it has no mica fire barrier.
Shipboard Fire Integrity & EMC Performance
- Select the complete construction: The copper foil, tinned braid, inner covering and three insulated phase cores are separate layers.
- Route and equipment selection: Coordinate the drive output, motor insulation requirements, route length, screen connections and protective-conductor arrangement with the equipment design.
- Configuration and duty selection: Scroll the size table horizontally to compare all columns.
- Read the slash field before drawing the ground system: The phase/braid notation 3 × 50/25 describes three power cores plus the specified braid section.
Salt Fog, Mud, Oil & Low-Smoke Resistance
- Installation & Routing: Fixed offshore drive-to-motor connections with a specified EMC screen and motor-circuit design.
- Termination & Entry Check: Use each value for the stated construction and operating condition. Nominal dimensions belong to the listed configuration; include the voltage, core schedule and installation duty when selecting a size.
- NEK 606 IIIed.2004: Design-series reference; specify the required project edition.
- IEC 60092-350/-351/-352/-353: Marine cable design, insulation and installation references.
IEC 60092 / NEK 606 / BS Marine Standards
- NEK 606 IIIed.2004: Design-series reference; specify the required project edition.
- IEC 60092-350/-351/-352/-353: Marine cable design, insulation and installation references.
- IEC 60092-359: SHF2 sheath reference; SHF MUD is separately specified.
- IEC 60332-1-2; IEC 60332-3-22: Flame propagation references.
- IEC 60754-1; IEC 61034-2: Halogen and smoke-emission references.
Marine & Offshore Cable Engineering Guides

0.6/1 kV F-RFOU Offshore VFD Motor Cable Vessel, Platform & FPSO Routing
This 0.6/1 kV F-RFOU offshore VFD motor cable uses Class 5 tinned-copper phase conductors, HF-HEPR insulation and a halogen-free inner covering. A copper/polyester foil and a separate tinned-copper braid surround the three-phase assembly beneath the selected SHF2 or SHF MUD sheath. The representative 3 × 50/25 designation identifies three 50 mm² phase cores and a 25 mm² braid section, not three additional protective-conductor cores.
Select this flame-retardant offshore VFD route by the actual drive, motor and screen-bond arrangement. The conductor geometry differs from a separately specified symmetric-ground BFOU VFD build, while the fire-performance task differs from a mica-based fire-resistant cable. Keep voltage, foil/braid construction, braid section, sheath environment and the cable-entry dimensions together in the motor-cable schedule.
Shipboard Systems & Offshore Zone Coverage
- Fixed offshore drive-to-motor connections with a specified EMC screen and motor-circuit design.
Route and equipment selection
Coordinate the drive output, motor insulation requirements, route length, screen connections and protective-conductor arrangement with the equipment design. The cable construction does not establish a universal permitted motor-lead length. Identify any filters, special termination systems and fault-current requirements in the inquiry.
Compare related cable duties
- NEK 606 BFOU VFD 1.8/3 kV Fire-Resistant LSZH Offshore VFD Power Cable
- 600/1000 V Foil-and-Braid Shielded VFD Motor Cable
- Varolex 0.6/1 kV Copper-Tape Screened VSD / VFD Motor Cable, 3C+3E XLPE
0.6/1 kV F-RFOU Offshore VFD Motor Cable Marine & Offshore Technical FAQ
Specify the acceptance scope
Include the exact construction, required standard edition and test acceptance conditions in the purchase specification. Coordinate cable tests with the selected voltage, materials, installation supports and termination system. For a moving or subsea route, include the complete mechanical and environmental load schedule.
How does 0.6/1 kV F-RFOU Offshore VFD Motor Cable handle select the complete construction in field installations?
The copper foil, tinned braid, inner covering and three insulated phase cores are separate layers. The /25 field on 3 × 50/25 is braid area. The selected geometry does not add three insulated PE cores, and it has no mica fire barrier.
Why is 'Route and equipment selection' critical when specifying 0.6/1 kV F-RFOU Offshore VFD Motor Cable?
Coordinate the drive output, motor insulation requirements, route length, screen connections and protective-conductor arrangement with the equipment design. The cable construction does not establish a universal permitted motor-lead length. Identify any filters, special termination systems and fault-current requirements in the inquiry.
How should engineers address 'compare related cable duties' for 0.6/1 kV F-RFOU Offshore VFD Motor Cable?
NEK 606 BFOU VFD 1.8/3 kV Fire-Resistant LSZH Offshore VFD Power Cable 600/1000 V Foil-and-Braid Shielded VFD Motor Cable Varolex 0.6/1 kV Copper-Tape Screened VSD / VFD Motor Cable, 3C+3E XLPE
How does the internal construction of 0.6/1 kV F-RFOU Offshore VFD Motor Cable protect against mechanical or EMI stress?
Conductors: Class 5 multibunch tinned copper.; Insulation: HF-HEPR on three phase cores.; Inner covering: Halogen-free compound.; Screens: Copper/polyester foil plus separate tinned-copper braid.; Sheath: SHF2 or explicitly selected SHF MUD.
Use each value for the stated construction and operating condition. Nominal dimensions belong to the listed configuration; include the voltage, core schedule and installation duty when selecting a size.
TEBAOFLEX® — 0.6/1 kV F-RFOU Offshore VFD Motor Cable technical parameters
| Parameter | Value / condition |
|---|---|
| Selected rated voltage | 0.6/1 kV |
| Representative configuration | 3 × 50/25 mm² phase/braid schedule |
| Representative OD /mass | 34.7 mm /2700 kg/km |
| Representative minimum bend radius | 209 mm |
| Representative resistance at 20°C | 0.393 Ω/km |
| Representative current at 45°C free air | 167 A |
| Conductor class | Class 5 tinned copper |
TEBAOFLEX® — 0.6/1 kV F-RFOU Offshore VFD Motor Cable configuration comparison
| Configuration | Selection scope |
|---|---|
| F-RFOU 0.6/1 kV VFD | Selected Class 5 foil/braid design and size table. |
| BFOU VFD 1.8/3 kV | Separate fire-resistant voltage/ground arrangement. |
| Industrial foil/braid VFD | Compare installation environment, voltage markings and sheath requirements. |
TEBAOFLEX® — Class 5 F-RFOU VFD cable nominal dimensions and conditional current references
| F-RFOU configuration (mm²) | OD (mm) | Mass (kg/km) | Min.bend (mm) | Current 45°C free air(A) |
|---|---|---|---|---|
| F-RFOU 3 × 50/25 | 34.7 | 2700 | 209 | 167 |
| F-RFOU 3 × 70/35 | 39.6 | 3650 | 238 | 214 |
| F-RFOU 3 × 95/50 | 43.9 | 4650 | 264 | 259 |
| F-RFOU 3 × 120/60 | 49.1 | 5900 | 295 | 301 |
| F-RFOU 3 × 150/70 | 54.5 | 7300 | 327 | 347 |
Configuration and duty selection
Scroll the size table horizontally to compare all columns.
Read the slash field before drawing the ground system
The phase/braid notation 3 × 50/25 describes three power cores plus the specified braid section. Define any separate PE and screen bonds from the circuit design; do not redraw the cable as 3C+3E. A 360° screen interface and an earth-fault requirement should each have their own termination and acceptance checks.
Selection guide: The copper foil, tinned braid, inner covering and three insulated phase cores are separate layers. The /25 field on 3 × 50/25 is braid area. The selected geometry does not add three insulated PE cores, and it has no mica fire barrier.
Ordering & Quotation Checklist: Send drive and motor details, phase/braid sizes, rated voltage, route length, current and grouping, PE scheme, screen interface, gland drawings and sheath environment.