FG16OR16FR16 0.6/1 kV SWA Armored Hydrocarbon-Resistant HEPR Cable

FG16OR16FR16 is a heavy-duty 0.6/1 kV (600/1,000 V) steel-wire armored and hydrocarbon-resistant flexible power, signalling, and control cable engineered to CEI 20-13, CEI 20-34/0 (ENI petrochemical hydrocarbon specification), and EN 50575 (CPR Euroclass Cca-s3,d1,a3). Built with IEC 60228 Class 5 flexible bare or tinned copper conductors, 90 °C G16 HEPR rubber core insulation, an inner R16 PVC bedding sheath.

  • Model designationFG16OR16FR16 0.6/1 kV (CU / HEPR G16 / PVC R16 / SWA+CS / PVC R16 HC)
  • Standards & CPRCEI 20-13, CEI 20-34/0 (Hydrocarbon & Oil), EN 50575 CPR Cca-s3,d1,a3
  • Rated voltage0.6/1 kV (600/1,000 V AC); 3,500 V AC × 5 min test voltage
  • Conductor & InsulationClass 5 flexible annealed or tinned copper; 90 °C HEPR G16 elastomer
  • Inner sheath (OR16)Extruded R16 quality flame-retardant PVC bedding under armor
  • Armor (FR)Galvanized round steel wire armor + steel counter-spiral tape (SWA + CS)
  • Outer sheath (R16 HC)Hydrocarbon-, oil-, chemical- & sunlight-resistant R16 PVC (Black/Grey/Blue)
  • Thermal & mechanical-30 °C to +90 °C core (+250 °C short-circuit); min bend radius 10–15 × OD
Category:

FG16OR16FR16 0.6/1 kV Core Identification & Ratings

  • Type: Oil & Gas Cable
  • Model designation: FG16OR16FR16 0.6/1 kV (CU / HEPR G16 / PVC R16 / SWA+CS / PVC R16 HC
  • Standards & CPR: CEI 20-13, CEI 20-34/0 (Hydrocarbon & Oil), EN 50575 CPR Cca-s3,d1,a3
  • Rated voltage: 0.6/1 kV (600/1,000 V AC); 3,500 V AC × 5 min test voltage

Electrical, Thermal & Mechanical Bend Limits

  • Conductor & Insulation: Class 5 flexible annealed or tinned copper; 90 °C HEPR G16 elastomer
  • Inner sheath (OR16): Extruded R16 quality flame-retardant PVC bedding under armor
  • Armor (FR): Galvanized round steel wire armor + steel counter-spiral tape (SWA + CS
  • Outer sheath (R16 HC): Hydrocarbon-, oil-, chemical- & sunlight-resistant R16 PVC (Black/Grey/Blue
  • Thermal & mechanical: -30 °C to +90 °C core (+250 °C short-circuit); min bend radius 10–15 × OD

FG16OR16FR16 0.6/1 kV Conductor, Insulation & Sheath Build

FG16OR16FR16 features a dual R16 PVC sheath sandwiching a galvanized round steel wire armor and steel counter-spiral (SWA+CS) over G16 HEPR cores.

  • Conductor (F): Class 5 flexible stranded annealed red copper (or tinned copper on request) per IEC 60228.
  • Insulation (G16): Cross-linked ethylene-propylene HEPR elastomer of G16 quality (+90 °C operating / +250 °C short-circuit).
  • Inner Sheath (OR16): Cabled cores filled and covered with an extruded R16 quality flame-retardant PVC inner bedding jacket.
  • Armor (FR): Galvanized round steel wire armor bound with a reverse-wound steel counter-spiral tape (SWA + CS).
  • Outer Sheath (R16 HC): Hydrocarbon-, chemical-, oil- and sunlight-resistant R16 PVC compound (CEI 20-34/0) in Black, Grey, or Blue.

Primary Electrical & Mechanical Performance

  • SWA + steel counter-spiral (FR): Galvanized round steel wires locked by a reverse-helix steel counter-spiral tape deliver superior crush, impact, tensile (50 N/mm²), and anti-rodent protection.
  • CEI 20-34/0 hydrocarbon resistance: Specially compounded R16 PVC outer sheath resists aliphatic/aromatic hydrocarbons, mineral oils, and aggressive chemical condensates in refinery trenches.
  • CPR Class Cca-s3,d1,a3 fire rating: Meets EU Regulation 305/2011 and EN 50575 Cca-s3,d1,a3 for bunched tray installations inside industrial and civil engineering structures.
  • Class 5 flexibility up to 5G240 mm²: Unlike rigid Class 2 SWA cables, Class 5 fine-stranded copper cores simplify termination inside compact explosion-proof (Ex d / Ex e) glands and MCC cubicles.

Industrial Oil, Flame & Environmental Protection

  • Dual R16 PVC sheath barrier: A complete extruded inner R16 PVC bedding sheath plus a thick hydrocarbon-resistant outer R16 PVC jacket prevents chemical migration to the HEPR G16 cores.
  • 90 °C HEPR G16 thermal margin: Cross-linked G16 ethylene-propylene rubber operates at +90 °C continuous conductor temperature and +250 °C short-circuit temperature.
  • Direct burial & suspended tray ready: Approved for direct or indirect underground burial, flooded sand trenches, masonry brackets, pipe racks, and outdoor cable trays.
  • Annealed or tinned copper options: Supplied with Class 5 plain annealed red copper as standard, or Class 5 tinned copper conductors for sour-gas (H2S) petrochemical atmospheres.

IEC / EN / VDE / UL Reference Standards

  • CEI 20-13 & IEC 60502-1: 0.6/1 kV HEPR G16 insulated armored power and control cables
  • CEI 20-34/0 & ENI Petrochemical Spec: aliphatic/aromatic hydrocarbon & mineral oil resistance
  • EN 50575 & EN 50399 CPR Euroclass Cca-s3,d1,a3: bunched flame & heat release
  • IEC 60228 Class 5 flexible annealed or tinned copper conductors
  • IEC 60332-1-2 vertical flame retardance & EU RoHS 2011/65/EU

Industrial Cable Selection & Routing Guides

Petrochemical processing installation and armored cable tray runs using FG16OR16FR16 0.6/1 kV hydrocarbon-resistant steel-wire armored HEPR cables
FG16OR16FR16 0.6/1 kV combines G16 HEPR insulation, SWA + counter-spiral steel armor, and a CEI 20-34/0 hydrocarbon-resistant R16 sheath for refineries and chemical plants. Photo: Wikimedia Commons contributor, CC BY-SA 2.0, via Wikimedia Commons.

FG16OR16FR16 0.6/1 kV Industrial Installation & Routing Guide

FG16OR16FR16 is the armored petrochemical and heavy-industrial variant of the Italian CEI 20-13 0.6/1 kV HEPR cable family, specifically engineered for refineries, LNG terminals, chemical processing units, and ENI-type onshore oil & gas facilities where underground or tray-routed cables face simultaneous mechanical crushing, rodent attack, and soil/trench contamination by aliphatic and aromatic hydrocarbons. In the designation FG16OR16FR16: F is Class 5 flexible copper; G16 is +90 °C high-modulus HEPR insulation; OR16 is the inner filler and extruded R16 PVC inner sheath; FR denotes galvanized round steel wire armor bound with an open-helix steel counter-spiral (SWA + CS); and the final 16 is the CEI 20-34/0 hydrocarbon- and oil-resistant R16 outer PVC sheath.

Certified to EN 50575 CPR Euroclass Cca-s3,d1,a3 (EN 50399 / IEC 60332-1-2), FG16OR16FR16 can be routed continuously from outdoor buried pipe racks and hydrocarbon-exposed process skids directly into high-occupancy control buildings and substations without transition junction boxes. Compare with our unarmoredFG16(O)R16 and FG16(O)M16 0.6/1 kV HEPR cables, copper-braid screenedFG16OH2R16 0.6/1 kV EMC control cables, and offshoreBS 6883 / BS 7917 SW4/SW2 power cables.

Typical Plant, Machine & Infrastructure Circuits

  • Multi-core control and instrumentation feeders (2×1.5 mm² to 24×2.5 mm²) connect refinery tank-farm motorized valves (MOVs), emergency shutdown (ESD) solenoids, fiscal metering skids, and hazardous-area local control stations (available with blue outer sheath for intrinsically safe Ex-i circuits or black/grey sheath for power and control).
  • Heavy multi-core power feeders (3×4 mm² to 3×240 mm², 4×6 mm² to 4×240 mm², and 5G1.5 to 5G240 mm²) supply petrochemical process pumps, air-cooled heat exchangers, compressor lube-oil skids, and direct-buried substation interconnect runs.

FG16OR16FR16 0.6/1 kV Specification & Selection FAQ

What does 'FR16' stand for in FG16OR16FR16?

In the Italian CEI designation FG16OR16FR16, 'OR16' denotes the inner R16 PVC bedding sheath over the cabled G16 HEPR cores, 'F' denotes galvanized round steel wire armor with a steel counter-spiral tape (SWA+CS), and the final 'R16' denotes the outer R16 PVC sheath formulated for hydrocarbon resistance (CEI 20-34/0) and CPR Class Cca-s3,d1,a3.

Why is FG16OR16FR16 specified in ENI and petrochemical refineries?

Standard PVC or unarmored cables swell, crack, or degrade when buried in soil or laid in trenches contaminated by crude oil, diesel, condensate, or aromatic hydrocarbons. FG16OR16FR16 combines a CEI 20-34/0 hydrocarbon-resistant R16 outer sheath with galvanized steel wire armor for both chemical immunity and crush protection.

What is the minimum bending radius of FG16OR16FR16?

Because of the galvanized steel wire armor and steel counter-spiral, the minimum bending radius is 10 × to 15 × the overall cable diameter, with a maximum pulling tension of 50 N/mm² on the copper conductors.

Is FG16OR16FR16 available with a blue sheath for intrinsically safe (Ex-i) circuits?

Yes. FG16OR16FR16 can be manufactured with a black or grey outer jacket for 0.6/1 kV power and control circuits, or a light blue (RAL 5015) hydrocarbon-resistant outer jacket for intrinsically safe Ex-i refinery control loops.

Dimensional, under-armor diameter, copper index, and weight tables for CEI 20-13 FG16OR16FR16 0.6/1 kV steel-wire armored hydrocarbon-resistant multi-core control cables (2×1.5 to 24×2.5 mm²) and heavy power feeders (2×4 to 5G240 mm²).

TEBAOFLEX® — FG16OR16FR16 0.6/1 kV SWA Armored Hydrocarbon-Resistant HEPR Cable

FG16OR16FR16 0.6/1 kV (ENI Spec) Armored Hydrocarbon-Resistant Control & Small Power Cable Specifications (CEI 20-13)
Formation (Cores × mm²) Max. DC Resistance at 20 °C (Ω/km) Nom. Under-Armor Ø (mm) Nom. Overall OD (mm) Approx. Total Weight (kg/km)
2 × 1.5 13.3 8.00 13.30 319
3 × 1.5 13.3 8.47 13.77 351
4 × 1.5 13.3 9.22 14.52 394
5 × 1.5 13.3 10.07 15.37 442
7 × 1.5 13.3 10.95 16.25 504
12 × 1.5 13.3 14.37 19.67 724
16 × 1.5 13.3 15.97 21.27 856
24 × 1.5 13.3 19.21 24.51 1,129
3 × 2.5 7.98 9.42 14.72 413
5 × 2.5 7.98 11.25 16.55 533
7 × 2.5 7.98 12.27 17.57 620
12 × 2.5 7.98 16.20 21.50 911
16 × 2.5 7.98 18.03 23.33 1,092
24 × 2.5 7.98 21.76 27.26 1,481

TEBAOFLEX® — FG16OR16FR16 0.6/1 kV SWA Armored Hydrocarbon-Resistant HEPR Cable

FG16OR16FR16 0.6/1 kV SWA+CS Armored Multi-Core Power Feeder Specifications (3-Core, 4-Core & 5G)
Formation (Cores × mm²) Nom. Overall OD (mm) Copper Index (kg/km) Approx. Total Weight (kg/km) Max. DC Resistance at 20 °C (Ω/km)
3 × 4 18.4 115 626 4.95
3 × 6 19.7 173 734 3.30
3 × 10 21.8 288 960 1.91
3 × 16 24.2 461 1,241 1.21
3 × 25 28.4 720 1,787 0.780
3 × 35 31.5 1,008 2,247 0.554
3 × 50 37.6 1,440 3,197 0.386
3 × 70 41.5 2,016 4,078 0.272
3 × 95 47.5 2,736 5,284 0.206
3 × 150 57.1 4,320 7,829 0.129
3 × 240 68.5 6,912 11,611 0.0801
4 × 16 26.2 614 1,498 1.21
4 × 35 34.5 1,344 2,764 0.554
4 × 70 45.9 2,688 5,109 0.272
4 × 120 59.4 4,608 8,320 0.161
4 × 240 76.1 9,216 14,728 0.0801
5G 16 29.0 768 1,872 1.21
5G 35 38.1 1,680 3,442 0.554
5G 70 50.5 3,360 6,200 0.272
5G 120 65.4 5,760 10,125 0.161
5G 240 84.0 11,520 18,058 0.0801

Selection guide: Specify FG16OR16FR16 0.6/1 kV, core count × cross-section (2×1.5 to 24×2.5 mm² or 2×4 to 5G240 mm²), plain or tinned copper, and outer sheath color (Black, Grey, or Ex-i Blue). Also compare our Class 5 flexible armored XLPE familyRVFV-K (U-1000 RVFV), RVhMVh-K, RZ1FZ1-K & RZ1MZ1-K 0.6/1 kVand medium-voltageRHVhMVh 3.6/6–18/30 kV SWA armored hydrocarbon-resistant MV cable.

Ordering & Quotation Checklist: Request a factory quotation for CEI 20-13 FG16OR16FR16 0.6/1 kV SWA+CS armored hydrocarbon-resistant HEPR power and control cables.

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for FG16OR16FR16 0.6/1 kV SWA Armored Hydrocarbon-Resistant HEPR Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.

  • ISO 9001 Factory Direct
  • MOQ 50 m (Custom Builds)
  • 24h Engineering Reply
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    FG16OR16FR16 0.6/1 kV SWA Armored Hydrocarbon-Resistant HEPR CableGet A Quote