IRAM 2178-1 0.6/1 kV Hydrocarbon-Resistant XLPE Oil & Gas Power & Control Cable

IRAM 2178-1 / IEC 60502-1 0.6/1 kV Hydrocarbon-Resistant Power Cables (1 to 5 cores, 1.5 mm² to 630 mm²) and Control Cables (2 to 48 cores, 1.0 mm² to 10 mm²) are engineered specifically for petroleum refineries, tank farms, petrochemical complexes, and unconventional oil/gas gathering facilities (such as Vaca Muerta and MERCOSUR downstream plants).

  • Standard designationsIRAM 2178-1, IEC 60502-1, YPF / Petrobras / ENI refinery hydrocarbon sheath specs
  • Armor & shield optionsUnarmored; Copper Tape Shield + STA (-W); Double Steel Tape (STA / -F); Steel Wire (SWA / -H)
  • Rated voltage U0/U0.6/1 kV AC (Um 1.2 kV); 3,500 V AC 5-minute dielectric withstand
  • ConductorClass 5 flexible annealed electrolytic copper per IRAM NM 280 / IEC 60228
  • Insulation90 °C cross-linked polyethylene (XLPE), +250 °C short-circuit rating
  • Inner & outer sheathsSpecial hydrocarbon-, oil-, acid- and alkali-resistant PVC compound (black UV-stabilized)
  • Size & core rangePower: 1×1.5 to 1×630 mm² & 2×1.5 to 5×300 mm²; Control: 2×1.0 to 48×2.5 mm² (up to 10 mm²)
  • Flame & environmentalIEC 60332-1-2 & IEC 60332-3-24 Cat. C bunched flame; ASTM D471 / IRAM oil & fuel immersion
Category:

IRAM 2178-1 / IEC 60502-1 0.6/1 kV Core Identification & Ratings

  • Type: Oil & Gas Cable
  • Standard designations: IRAM 2178-1, IEC 60502-1, YPF / Petrobras / ENI refinery hydrocarbon sheath specs
  • Armor & shield options: Unarmored; Copper Tape Shield + STA (-W); Double Steel Tape (STA / -F); Steel Wire (SWA / -H
  • Rated voltage U0/U: 0.6/1 kV AC (Um 1.2 kV); 3,500 V AC 5-minute dielectric withstand

Electrical, Thermal & Mechanical Bend Limits

  • Conductor: Class 5 flexible annealed electrolytic copper per IRAM NM 280 / IEC 60228
  • Insulation: 90 °C cross-linked polyethylene (XLPE), +250 °C short-circuit rating
  • Inner & outer sheaths: Special hydrocarbon-, oil-, acid- and alkali-resistant PVC compound (black UV-stabilized
  • Size & core range: Power: 1×1.5 to 1×630 mm² & 2×1.5 to 5×300 mm²; Control: 2×1.0 to 48×2.5 mm² (up to 10 mm²
  • Flame & environmental: IEC 60332-1-2 & IEC 60332-3-24 Cat. C bunched flame; ASTM D471 / IRAM oil & fuel immersion

IRAM 2178-1 / IEC 60502-1 0.6/1 kV Conductor, Insulation & Sheath Build

Built for downstream refineries, tank farms, and upstream oilfields, these cables pair 90 °C XLPE core insulation with hydrocarbon-resistant inner and outer PVC sheaths and optional metallic screening/armoring.

  • Conductor: Annealed electrolytic copper, flexible Class 5 stranding per IRAM NM 280 / IEC 60228 (1.0 mm² to 630 mm²).
  • Insulation: 90 °C cross-linked polyethylene (XLPE); color-coded on 1–5C power cores, white-numbered black cores on 6–48C control.
  • Inner Bedding & Screen (-W): Extruded hydrocarbon-resistant PVC inner sheath; optional 100% helically lapped annealed copper tape screen on -W types.
  • Metallic Armor (-F / -H): Double helical galvanized steel tape armor (STA / -F) or single-layer galvanized steel wire armor (SWA / -H).
  • Outer Sheath: Black UV-stabilized hydrocarbon-, oil-, acid- and alkali-resistant PVC compound passing IEC 60332-3-24 Cat. C.

Primary Electrical & Mechanical Performance

  • Aliphatic & aromatic hydrocarbon resistance: Specially formulated black hydrocarbon-resistant PVC outer and inner sheaths withstand prolonged immersion in petroleum distillates, mineral oils, weak acids, and alkalis.
  • 4 mechanical & EMC protection tiers: Available Unarmored, STA (Double Steel Tape), SWA (Galvanized Steel Wire), or Copper-Tape Screened + STA (-W) for combined EMI shielding and mechanical crush defense.
  • Class 5 flexible copper + 90 °C XLPE: IRAM NM 280 Class 5 flexible stranding simplifies termination in explosion-proof Ex d glands and junction boxes while sustaining 90 °C continuous load.
  • Matched 3.3–33 kV MV hydrocarbon family: Pairs directly with ourIRAM 2178-2 3.3–33 kV hydrocarbon-resistant medium-voltage cablesfor complete refinery power distribution.

Industrial Oil, Flame & Environmental Protection

  • Lead-free chemical barrier alternative: Replaces heavy, toxic lead-sheathed cables in most refinery trench classifications while maintaining circular cross-sections compatible with standard Ex d/e barrier glands.
  • Copper tape screen + STA (-W) option: 100% helically lapped bare copper tape screen drains capacitive ground-fault currents and shields control circuits from HV substation and VFD noise.
  • Bunched flame test IEC 60332-3-24 Cat. C: Even with hydrocarbon-resistant compounding, the outer sheath passes vertical bunched tray flame propagation tests for open pipe-rack installation.
  • UV, ozone & -15 °C / -25 °C weatherability: Carbon-black UV stabilization protects exposed desert and patagonian oilfield cable racks from solar cracking.

IEC / EN / VDE / UL Reference Standards

  • IRAM 2178-1 & IEC 60502-1: 0.6/1 kV XLPE insulated power and control cables
  • ASTM D471 / IRAM Hydrocarbon Immersion Test: Resistance to aliphatic/aromatic oils, fuels & solvents
  • IRAM NM 280 / IEC 60228: Class 5 flexible annealed electrolytic copper conductors
  • IEC 60332-1-2 & IEC 60332-3-24 Cat. C: Single-cable & bunched vertical tray flame retardance
  • AEA 90364-7-790 / IEC 60079-14: Electrical installations in explosive gas & petrochemical atmospheres

Industrial Cable Selection & Routing Guides

Oil and gas refinery pipe rack and hazardous-area pump station wired with IRAM 2178-1 0.6/1 kV hydrocarbon-resistant XLPE power and control cables
IRAM 2178-1 0.6/1 kV hydrocarbon-resistant XLPE power and control cables (unarmored, copper-tape screened, STA and SWA armored) for petrochemical plants and tank farms. Photo: Wikimedia Commons contributor, CC BY-SA 2.0, via Wikimedia Commons.

IRAM 2178-1 / IEC 60502-1 0.6/1 kV Industrial Installation & Routing Guide

Standard PVC cable sheaths swell, crack, and leach plasticizers when buried in refinery trenches or routed through petrochemical process units exposed to crude oil condensates, diesel fuel, kerosene, aromatics, and chemical solvents. Our IRAM 2178-1 / IEC 60502-1 0.6/1 kV Hydrocarbon-Resistant Power and Control Cable family solves this degradation without requiring expensive lead sheaths by compounding both the inner bedding and the outer jacket from a high-molecular-weight nitrile/polymer-modified hydrocarbon-resistant PVC compound over 90 °C XLPE-insulated Class 5 flexible copper conductors.

To match every hazardous-location and underground mechanical specification across oil & gas EPC projects, the series is produced in four complete configurations for both Power (1–5C, 1.5–630 mm²) and Control (2–48C, 1.0–10 mm²): Unarmored (for above-ground refinery ladder trays and conduits), Double Galvanized Steel Tape Armored (STA / -F), Galvanized Steel Wire Armored (SWA / -H), and Helical Copper Tape Screened + Double Steel Tape Armored (-W)—which adds a 100% overlapping annealed copper tape electromagnetic screen beneath the steel armor to protect refinery DCS/ESD trips and motor feeders from switching transients. Compare with our EuropeanRVhMVh-K and FG16OR16FR16 hydrocarbon-resistant armored cablesand North AmericanType TC-ER-HL polymeric-armored oil & gas cables.

Typical Plant, Machine & Infrastructure Circuits

  • IRAM 2178-1 0.6/1 kV Hydrocarbon-Resistant Power Cables (1×1.5 mm² to 1×630 mm² and 2×1.5 to 5×300 mm²) feed API process pumps, air-fin cooler fans, compressor lube-oil skids, and tank-farm motorized isolation valves in direct-buried refinery trenches, sand-filled concrete troughs, and open pipe racks.
  • IRAM 2178-1 0.6/1 kV Hydrocarbon-Resistant Control Cables (2×1.0 mm² to 48×2.5 mm², including Cu-Tape + STA -W screened types) interconnect emergency shutdown (ESD) solenoids, switchgear protection relays, and hazardous-area local control stations where oil spills and electromagnetic interference coexist.

IRAM 2178-1 / IEC 60502-1 0.6/1 kV Specification & Selection FAQ

Why are standard PVC cables unsuitable for direct burial in oil refineries and tank farms?

Standard plasticized PVC sheaths absorb liquid hydrocarbons (diesel, gasoline, crude condensates, and aromatic solvents), causing the plasticizer to leach out and the jacket to swell or crack. Hydrocarbon-resistant IRAM 2178-1 cables use a polymer-modified compound that resists swelling and maintains mechanical integrity.

What is the advantage of the Copper-Tape Screened + Steel Tape Armored (-W) configuration?

The -W construction places a 100% lapped bare copper tape screen under the double galvanized steel tape armor. The copper tape provides a low-impedance fault-current return path and electrostatic EMI shielding, while the steel tape armor provides radial crush and rodent protection.

Can these hydrocarbon-resistant cables be installed with standard Ex d/e barrier cable glands?

Yes. All armored (STA, SWA, and Cu-Tape+STA) and unarmored multi-core variants have a round extruded inner bedding and circular outer profile engineered to seal tightly inside standard brass or stainless-steel Ex d / Ex e hazardous-area cable glands.

Are medium-voltage (3.3 kV to 33 kV) hydrocarbon-resistant cables also available?

Yes. We manufacture matching IRAM 2178-2 and IEC 60502-2 (3.3 kV to 33 kV) medium-voltage XLPE cables with hydrocarbon-resistant inner and outer sheaths in both unarmored and SWA-armored designs.

Dimensional, weight, and current-rating specifications for IRAM 2178-1 0.6/1 kV hydrocarbon-resistant XLPE power and multiconductor control cables across Unarmored, Copper-Tape + STA, Double Steel Tape (STA) and Galvanized Steel Wire Armor (SWA) designs.

TEBAOFLEX® — IRAM 2178-1 0.6/1 kV Hydrocarbon-Resistant XLPE Oil & Gas Power & Control Cable

IRAM 2178-1 0.6/1 kV Hydrocarbon-Resistant XLPE Power Cable Specifications (Unarmored, Cu-Tape+STA, STA & SWA)
Formation × Size (mm²) XLPE Wall (mm) Unarmored OD (mm) Unarmored Weight (kg/km) STA / Cu-Tape+STA OD (mm) SWA Armored OD (mm) SWA Weight (kg/km) Ampacity Air / Buried 90 °C (A)
2 × 4 0.7 11.2 165 14.8 16.0 455 46 / 56
3 × 4 + 1G4 0.7 13.2 275 16.8 18.2 610 45 / 54
3 × 10 + 1G10 0.7 16.8 535 20.6 22.2 1,015 77 / 88
3 × 16 + 1G16 0.7 20.0 825 24.0 25.8 1,465 105 / 115
3 × 25 + 1G16 0.9 23.2 1,150 27.4 29.4 1,940 135 / 145
3 × 35 + 1G16 0.9 25.6 1,505 30.0 32.2 2,440 168 / 172
3 × 50 + 1G25 1.0 29.6 2,080 34.2 36.6 3,250 205 / 205
3 × 70 + 1G35 1.1 33.8 2,875 38.8 41.6 4,320 260 / 250
3 × 95 + 1G50 1.1 38.2 3,860 43.6 46.8 5,620 318 / 298
3 × 120 + 1G70 1.2 42.8 4,860 48.4 51.8 6,890 368 / 340
3 × 150 + 1G70 1.4 47.2 5,920 53.2 56.8 8,280 420 / 382
3 × 185 + 1G95 1.6 52.4 7,340 58.8 62.6 10,020 480 / 430
3 × 240 + 1G120 1.7 59.2 9,540 66.0 70.2 12,750 570 / 500

TEBAOFLEX® — IRAM 2178-1 0.6/1 kV Hydrocarbon-Resistant XLPE Oil & Gas Power & Control Cable

IRAM 2178-1 0.6/1 kV Hydrocarbon-Resistant XLPE Multi-Core Control Cable Specifications (Unarmored, Cu-Tape+STA, STA & SWA)
Core Count × Size (mm²) XLPE Wall (mm) Unarmored OD (mm) Unarmored Weight (kg/km) Cu-Tape+STA (-W) OD (mm) SWA (-H) OD (mm) SWA Weight (kg/km) Max. DC Res. 20 °C (Ω/km)
2 × 1.5 0.7 9.0 105 13.0 13.6 320 13.3
4 × 1.5 0.7 10.4 150 14.4 15.0 405 13.3
7 × 1.5 0.7 12.2 220 16.4 17.0 520 13.3
12 × 1.5 0.7 15.8 355 20.2 21.0 760 13.3
19 × 1.5 0.7 18.6 520 23.2 24.2 1,035 13.3
27 × 1.5 0.7 22.2 725 27.0 28.4 1,400 13.3
37 × 1.5 0.7 25.0 960 30.0 31.6 1,760 13.3
4 × 2.5 0.7 11.6 200 15.6 16.2 490 7.98
7 × 2.5 0.7 13.6 305 17.8 18.6 650 7.98
12 × 2.5 0.7 17.8 495 22.4 23.4 975 7.98
19 × 2.5 0.7 21.0 750 25.8 27.0 1,360 7.98
27 × 2.5 0.7 25.2 1,050 30.2 31.8 1,845 7.98
4 × 4.0 0.7 13.2 285 17.4 18.2 620 4.95

Selection guide: Specify IRAM 2178-1 0.6/1 kV Hydrocarbon-Resistant XLPE Power or Control Cable, protection tier (Unarmored, Cu-Tape + STA -W, Double Steel Tape STA -F, or Galvanized Steel Wire SWA -H), and core formation.

Ordering & Quotation Checklist: Request a factory quotation for IRAM 2178-1 0.6/1 kV hydrocarbon-resistant XLPE oil & gas power and control cables (Unarmored, Cu-Tape+STA, STA or SWA).

FG16OR16FR16 0.6/1 kV SWA Armored Hydrocarbon-Resistant HEPR Cable

FG16OR16FR16 0.6/1 kV SWA Armored Hydrocarbon-Resistant HEPR Cable

FG16OR16FR16 0.6/1 kV (CU / HEPR G16 / PVC R16 / SWA+CS / PVC R16 HC)

VIEW PRODUCT »

600V/1000V Type TC-ER-HL Polymeric-Armored VFD & Oil & Gas Power Cable

600V/1000V Type TC-ER-HL Polymeric-Armored VFD & Oil & Gas Power Cable

Type TC-ER-HL 600V / Type TC-ER 1000V Polymeric-Armored VFD, Power & Control

VIEW PRODUCT »

IRAM 2178-2 (3.3–33 kV) & ICEA S-93-639 (5–35 kV) Medium-Voltage XLPE Cable

IRAM 2178-2 (3.3–33 kV) & ICEA S-93-639 (5–35 kV) Medium-Voltage XLPE Cable

IRAM 2178-2 (2015), IEC 60502-2, ICEA S-93-639 / NEMA WC 74, UL 1072

VIEW PRODUCT »

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for IRAM 2178-1 0.6/1 kV Hydrocarbon-Resistant XLPE Oil & Gas Power & Control Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.

  • ISO 9001 Factory Direct
  • MOQ 50 m (Custom Builds)
  • 24h Engineering Reply
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    IRAM 2178-1 0.6/1 kV Hydrocarbon-Resistant XLPE Oil & Gas Power & Control CableGet A Quote