600V Twisted Submersible Well Pump Cable & Shielded 5G Small-Cell TC-ER Cable
Engineered for North American municipal/agricultural groundwater extraction and outdoor 5G / telecom remote radio head (RRH) DC power distribution, this specialized 600 V power cable page covers UL 83 Twisted 3-Core & 4-Core Soft Annealed Copper PVC Submersible Deep-Well Water Pump Cables (14 AWG to 2 AWG with full insulated green ground, -40 °C to +75 °C) alongside 600 V UL 1277 Type TC-ER Foil + 85% Tinned Copper Braid.
- Standard designationsUL 83 / NEC Art. 340 (Twisted Submersible Pump Cable) & UL 1277 / CSA FT4 (5G Small-Cell Type TC-ER)
- Rated voltage & temp.600 V AC/DC; -40 °C to +75 °C wet (Submersible Pump) & -40 °C to +90 °C wet/dry (5G Small-Cell TC-ER)
- ConductorsClass B or 19/49-strand bare copper (14–2 AWG Pump); Class K 30 AWG tinned copper (12–6 AWG Small-Cell)
- Core insulationHeavy-wall moisture-resistant THW/THWN PVC (Pump) or 90 °C FR-PVC + Nylon Type THHN/THWN-2 (5G TC-ER)
- Construction / ShieldingJacketless helical twist of 3 or 4 color-coded cores (Pump); 100% Al/Mylar Foil + 85% Tinned Cu Braid (5G)
- Outer jacket (5G TC-ER)Sunlight-resistant, oil-resistant, direct-burial Black PVC outer jacket passing UL 1277 TC-ER crush/impact
- Color codingBlack, Red, Yellow + Green Ground (4C Pump); Black + Red/White or Blue + Red (2C 5G Telecom DC)
- Target environmentsDeep-well submersible water pumps inside well casings; 5G street-pole small cells, DAS & macro-tower RRHs
600V UL 83 Twisted PVC Submersible Submersible & Hydrostatic Profile
- Type: Industrial Power Cable
- Standard designations: UL 83 / NEC Art. 340 (Twisted Submersible Pump Cable) & UL 1277 / CSA FT4 (5G Small-Cell Type TC-ER
- Rated voltage & temp.: 600 V AC/DC; -40 °C to +75 °C wet (Submersible Pump) & -40 °C to +90 °C wet/dry (5G Small-Cell TC-ER
- Conductors: Class B or 19/49-strand bare copper (14–2 AWG Pump); Class K 30 AWG tinned copper (12–6 AWG Small-Cell
Immersion Depth, Pressure & Thermal Ratings
- Core insulation: Heavy-wall moisture-resistant THW/THWN PVC (Pump) or 90 °C FR-PVC + Nylon Type THHN/THWN-2 (5G TC-ER
- Construction / Shielding: Jacketless helical twist of 3 or 4 color-coded cores (Pump); 100% Al/Mylar Foil + 85% Tinned Cu Braid (5G
- Outer jacket (5G TC-ER): Sunlight-resistant, oil-resistant, direct-burial Black PVC outer jacket passing UL 1277 TC-ER crush/impact
- Color coding: Black, Red, Yellow + Green Ground (4C Pump); Black + Red/White or Blue + Red (2C 5G Telecom DC
- Target environments: Deep-well submersible water pumps inside well casings; 5G street-pole small cells, DAS & macro-tower RRHs
600V UL 83 Twisted PVC Submersible Water-Blocked Core & Sheath Architecture
Two purpose-built 600 V outdoor/submerged constructions: jacketless twisted heavy-wall PVC cores for deep water wells, and dual foil+braid shielded Class K TC-ER for 5G radios.
- Conductors: 19- or 49-strand soft bare copper (14–2 AWG Pump Cable); Class K 30 AWG tinned copper (12–6 AWG 5G Small-Cell Cable).
- Core Insulation: 45–60 mil heavy-wall moisture-resistant PVC (Pump Cable); 90 °C PVC + Polyamide Nylon Type THHN/THWN-2 (5G Small-Cell).
- Cabling / Shielding: Helical twist without outer jacket (Pump); 100% Al/PET tape + tinned drain wire + 85% tinned copper braid shield (5G TC-ER).
- Outer Jacket (5G TC-ER): Sunlight-, oil- and moisture-resistant Black PVC jacket rated for direct burial and UL 1277 Type TC-ER exposed runs.
Hydrostatic Integrity & Tensile Load Performance
- UL 83 Twisted 3C & 4C Submersible Pump: Helically cabled heavy-wall moisture-resistant PVC copper conductors (14–2 AWG) engineered specifically for vertical deep-well drop-pipe installation.
- Color-Coded Cores + Full Green Ground: Black, Yellow, Red + Green (4-core) or Black, Red + Green (3-core) insulation eliminates splice errors at the submersible motor pigtail.
- 5G Small-Cell Foil + 85% Braid Shielding: Dual 100% Al/Mylar foil plus 85% tinned copper braid protects sensitive 5G remote radio heads from lightning transients and RF interference.
- Class K Tinned Cu & UL 1277 Type TC-ER: Ultra-flexible Class K tinned copper routes inside narrow street-pole handholes while passing UL TC-ER exposed-run and direct-burial tests.
Potable Water, Seawater, Slurry & Chlorine Resistance
- -40 °C arctic flexibility on both series: Both the twisted PVC submersible pump cable and the shielded 5G small-cell TC-ER cable pass -40 °C cold-bend testing for winter outdoor installation.
- Acid, alkali, oil & groundwater resistant: Submersible PVC compound resists mineral-rich groundwater, iron bacteria, and well-chlorination shock treatments without insulation swelling.
- Direct burial, duct & aerial messenger ready: The 5G Small-Cell Type TC-ER cable is rated for direct underground burial, innerduct pulls, cable trays, and exposed pole-top transitions.
- Complementary pump & telecom cable options: For heavy-duty rubber jacketed submersible cables seeIRAM 63007 / IEC submersible pump cables.
AD8 / KTW / ACS / Subsea Immersion Standards
- UL 83 & NEC Article 340: Thermoplastic-Insulated Deep-Well Submersible Water Pump Cable
- UL 1277: 600 V Type TC-ER Exposed Run Power and Control Tray Cable
- UL 1685 / IEEE 1202 / CSA C22.2 No. 0.3 FT4: Vertical Tray Flame & -40 °C Cold Bend
- ASTM B3, B8, B33 & B174: Soft Annealed Bare Copper & Class K Flexible Tinned Copper
- Telcordia / ATIS & NEC Article 800 / 830 Outdoor Small-Cell Remote Radio Power Guidelines
Submersible Pump & Subsea Cable Guides

600V UL 83 Twisted PVC Submersible Deep-Well, Dewatering & Subsea Deployment
Inside deep agricultural irrigation boreholes, residential water wells, and municipal aquifer casings, 600 V UL 83 Twisted Submersible Well Pump Cable (14 AWG to 2 AWG, 3-Conductor and 4-Conductor) connects the surface pressure switch or variable-speed pump controller down the vertical drop pipe to the submerged motor. By helically twisting three or four heavy-wall 75 °C wet-rated moisture- and abrasion-resistant PVC (Type THW / THWN) insulated annealed copper conductors together without a bulky outer jacket, the twisted bundle sheds water pressure, flexes easily around well-casing centralizers and torque arrestors down to -40 °C, and provides clear color identification (Black, Yellow, Red + Green insulated equipment ground on 3-wire capacitor-start and 3-phase motors; Black, Red + Green on 2-wire motors).
Above ground on urban smart-city streetlights, utility poles, stadium Distributed Antenna Systems (DAS), and 5G macro-cell towers, remote radio heads (RRHs) and active antenna units (AAUs) require clean, transient-free -48 V DC or 400 V DC / 600 V AC power over long vertical and underground runs. Our 600 V UL 1277 Type TC-ER Foil + 85% Tinned Copper Braid Shielded 5G Small-Cell & Telecom Power Cable (2C × 12 AWG to 6 AWG) combines finely stranded Class K (30 AWG stranding) tinned copper conductors, 90 °C THHN/THWN-2 PVC/Nylon core insulation, a 100% aluminum/polyester tape with tinned drain wire, and an 85% coverage tinned copper braid shield under a sunlight-resistant, direct-burial Black PVC jacket (CSA FT4, -40 °C). Compare with ourheavy-duty flat/round EPR/rubber submersible pump cablesandindoor telecom central-office battery cables.
Submersible Pumps, ROVs & Wet-Well Systems
- 600 V UL 83 Twisted Submersible Well Pump Cables (14/3 to 2/4 AWG with ground) power 2-wire single-phase, 3-wire single-phase (with control box), and 3-phase submersible borehole motors in residential wells, farm center-pivot irrigation, and geothermal supply wells.
- 600 V Foil + Braid Shielded Class K Type TC-ER 5G Small-Cell Cables (2C × 12 AWG to 6 AWG) deliver remote DC/AC power to 5G millimeter-wave small cells, C-band rooftop radios, highway ITS camera poles, and telecom tower base stations.
600V UL 83 Twisted PVC Submersible Immersion Depth & Sealing FAQ
When should I use 3-Conductor (2W+G) vs. 4-Conductor (3W+G) twisted submersible well pump cable?
Use 3-Conductor (Black, Red + Green Ground) for 2-wire single-phase submersible motors that have their starting switch built inside the motor. Use 4-Conductor (Black, Yellow, Red + Green Ground) for 3-wire single-phase submersible motors that use an above-ground capacitor start/run control box, as well as for 3-phase submersible motors.
Can jacketless twisted submersible well pump cable be buried directly in soil outside the well casing?
No. Jacketless twisted submersible pump cable is Listed for installation inside the well casing / drop pipe where it is mechanically protected by the well bore. For the underground trench between the wellhead pitless adapter and the house or pump house, use UL 493 Type UF-B or jacketed submersible cable (or install the conductors inside buried PVC/HDPE conduit).
Why do 5G small-cell and remote radio head (RRH) power cables require both a foil and an 85% tinned copper braid shield?
The 100% aluminum/polyester foil blocks high-frequency RF interference (MHz to GHz) around the antenna mast, while the heavy 85% tinned copper braid provides a low-resistance metallic path to divert lightning-induced surge currents on outdoor utility poles and macro towers.
Why are Class K tinned copper conductors used in the 600 V 5G Small-Cell Type TC-ER cable?
Streetlight poles and small-cell shrouds have extremely tight base handholes and sharp 90-degree entry bends. Finely stranded Class K (30 AWG stranding) tinned copper bends effortlessly without kinking and resists corrosion in damp coastal pole bases.
Conductor stranding, insulation wall thickness, nominal outside diameter, net weight, and ampacity tables for 600 V UL 83 twisted submersible well pump cables and 600 V foil+braid shielded 5G small-cell Type TC-ER cables.
TEBAOFLEX® — 600V Twisted Submersible Well Pump Cable & Shielded 5G Small-Cell TC-ER Cable
| Size & Total Conductors | Copper Stranding (Per Core) | Green Ground Size (AWG) | PVC Insulation Wall (mil / mm) | Nominal Twisted Bundle OD (in / mm) | Net Weight (lbs/kft / kg/km) | 75 °C Wet Ampacity (A) |
|---|---|---|---|---|---|---|
| 14 AWG × 3C (2W + Gnd) | 19-strand Bare Cu | 14 AWG | 45 / 1.14 | 0.355 / 9.0 | 62 / 92 | 15 |
| 14 AWG × 4C (3W + Gnd) | 19-strand Bare Cu | 14 AWG | 45 / 1.14 | 0.395 / 10.0 | 83 / 124 | 15 |
| 12 AWG × 3C (2W + Gnd) | 19-strand Bare Cu | 12 AWG | 45 / 1.14 | 0.395 / 10.0 | 88 / 131 | 20 |
| 12 AWG × 4C (3W + Gnd) | 19-strand Bare Cu | 12 AWG | 45 / 1.14 | 0.440 / 11.2 | 117 / 174 | 20 |
| 10 AWG × 3C (2W + Gnd) | 19-strand Bare Cu | 10 AWG | 45 / 1.14 | 0.448 / 11.4 | 130 / 193 | 30 |
| 10 AWG × 4C (3W + Gnd) | 19-strand Bare Cu | 10 AWG | 45 / 1.14 | 0.498 / 12.6 | 173 / 257 | 30 |
| 8 AWG × 4C (3W + Gnd) | 19-strand Bare Cu | 10 AWG | 60 / 1.52 | 0.625 / 15.9 | 266 / 396 | 50 |
| 6 AWG × 4C (3W + Gnd) | 19-strand Bare Cu | 8 AWG | 60 / 1.52 | 0.735 / 18.7 | 408 / 607 | 65 |
| 4 AWG × 4C (3W + Gnd) | 19-strand Bare Cu | 8 AWG | 60 / 1.52 | 0.840 / 21.3 | 596 / 887 | 85 |
| 2 AWG × 4C (3W + Gnd) | 19-strand Bare Cu | 6 AWG | 60 / 1.52 | 0.985 / 25.0 | 928 / 1,381 | 115 |
TEBAOFLEX® — 600V Twisted Submersible Well Pump Cable & Shielded 5G Small-Cell TC-ER Cable
| Configuration × Size | Class K Tinned Cu Stranding | THHN/THWN-2 Wall (PVC + Nylon mil) | Shielding Architecture | PVC Jacket Wall (mil / mm) | Nominal OD (in / mm) | Net Weight (lbs/kft / kg/km) | 90 °C Ampacity (A) |
|---|---|---|---|---|---|---|---|
| 2C × 12 AWG Shielded | 65 / 30 AWG Tinned Cu | 15 + 4 | 100% Foil + 85% Tinned Cu Braid | 45 / 1.14 | 0.390 / 9.9 | 102 / 152 | 30 |
| 2C × 10 AWG Shielded | 105 / 30 AWG Tinned Cu | 20 + 4 | 100% Foil + 85% Tinned Cu Braid | 45 / 1.14 | 0.455 / 11.6 | 146 / 217 | 40 |
| 2C × 8 AWG Shielded | 168 / 30 AWG Tinned Cu | 30 + 5 | 100% Foil + 85% Tinned Cu Braid | 60 / 1.52 | 0.595 / 15.1 | 238 / 354 | 55 |
| 2C × 6 AWG Shielded | 266 / 30 AWG Tinned Cu | 30 + 5 | 100% Foil + 85% Tinned Cu Braid | 60 / 1.52 | 0.680 / 17.3 | 335 / 499 | 75 |
| 3C × 10 AWG Shielded | 105 / 30 AWG Tinned Cu | 20 + 4 | 100% Foil + 85% Tinned Cu Braid | 45 / 1.14 | 0.485 / 12.3 | 188 / 280 | 40 |
| 3C × 8 AWG Shielded | 168 / 30 AWG Tinned Cu | 30 + 5 | 100% Foil + 85% Tinned Cu Braid | 60 / 1.52 | 0.635 / 16.1 | 306 / 455 | 55 |
Selection guide: Specify 600 V UL 83 Twisted PVC Submersible Well Pump Cable (3C or 4C, 14 AWG to 2 AWG) for borehole drop pipes, or 600 V Foil+Braid Shielded Class K Type TC-ER (12 AWG to 6 AWG) for 5G small-cell DC/AC power. For high-temperature 3–5 kV IEEE 1018 (EPDM) & IEEE 1019 (PP) downhole ESP oil/geothermal pump cables with PEEK + Lead Motor Lead Extensions (MLE), UL 1426 (BC-5W2) tinned marine bilge & NEC 680 fountain pump cables, and vented PUR/ETFE/FEP borehole level transmitter cables, seeIEEE 1018 & 1019 (3–5 kV) Downhole ESP Pump, PEEK MLE & 7-H Wireline Cable,UL 1426 (BC-5W2) Marine Bilge Pump, THOF Shore, UL 1081 Pool & NEC 680 Cable, andVented PUR/ETFE/FEP Level Transmitter & 02-250V6 Piezometer Cable.
Ordering & Quotation Checklist: Request a factory quotation for 600 V UL 83 twisted PVC submersible well pump cables (14–2 AWG) or 600 V foil+braid shielded Class K 5G small-cell Type TC-ER cables.
IRAM 63001 Concentric Service & IRAM 63007 Submersible Pump Cable (EPR/PUR)
IRAM 63001 (Concentric Service Drop) & IRAM 63007 (Flat & Round Submersible Pump)
600V UL 1569 Type MC THHN/THWN Aluminum Interlocked Armor & Jacketed MC Cable
UL 1569 (Metal-Clad Cables — Type MC), UL 83 (THHN/THWN-2), NEC Article 330, Federal Spec A-A-59544
12–52 kV Subsea DEH, 5 kV Skin-Effect (SECT), Alloy 825 MI Heating & Leak Cable
12–52 kV Subsea Direct Electrical Heating (DEH), 5 kV Skin-Effect (SECT), 600 V Alloy 825 MI, FG-OD Hydrocarbon Leak Cable
Request Quotation & Datasheet for This Cable
Need factory pricing, cross-section drawing or a full PDF datasheet for 600V Twisted Submersible Well Pump Cable & Shielded 5G Small-Cell TC-ER Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.
- ISO 9001 Factory Direct
- MOQ 50 m (Custom Builds)
- 24h Engineering Reply