APL-Sheathed CAM / ICAM Instrumentation Cable
300/500 V XLPE instrument cable with CAM or ICAM screening and a separate aluminium–polyethylene laminate beneath the PE jacket.
- Rated voltage300/500 V
- Maximum operating temperature+105 °C
- Minimum bend radius9 × overall diameter
- 1.5 mm² multipair or multitriple maximum conductor resistance at 20 °C13.5 Ω/km
- 1.5 mm² nominal mutual capacitance120 nF/km
- APL CAM, 1 pair × 1.0 mm²10.2 mm
- APL CAM, 2 pairs × 1.5 mm²16.2 mm
- APL ICAM, 2 pairs × 1.5 mm²16.5 mm
APL-Sheathed CAM / ICAM Instrumentation Signal & Bus Architecture
- Type: Industrial Cables
- Rated voltage: 300/500 V
- Maximum operating temperature: +105 °C
- Minimum bend radius: 9 × overall diameter
Impedance, Attenuation & Operating Limits
- 1.5 mm² multipair or multitriple maximum conductor resistance at 20 °C: 13.5 Ω/km
- 1.5 mm² nominal mutual capacitance: 120 nF/km
- APL CAM, 1 pair × 1.0 mm²: 10.2 mm
- APL CAM, 2 pairs × 1.5 mm²: 16.2 mm
- APL ICAM, 2 pairs × 1.5 mm²: 16.5 mm
APL-Sheathed CAM / ICAM Instrumentation Pair Twist, Foil & Braid Construction
- Conductor and insulation: Stranded annealed bunched copper with XLPE insulation.
- CAM: Collective aluminium/polyester tape with a tinned-copper drain.
- ICAM: Individual and collective aluminium/polyester tapes with tinned-copper drains.
- Bedding: PVC.
- APL layer: Aluminium–polyethylene laminate with a separate bunched tinned-copper drain.
- Outer sheath and core identification: Black PE. White and numbered black in pairs. Triples add red.
Signal Integrity, Crosstalk & Noise Rejection
- APL CAM, 2 pairs × 1.5 mm²: 16.2 mm
- APL ICAM, 2 pairs × 1.5 mm²: 16.5 mm
- Application Focus: Use on supported, fixed interconnections between measuring instruments, field junction boxes and monitoring equipment. Where groups need separate screen continuity, carry the group identifiers through every junction.
- Bedding: PVC.
Process Plant, Moisture, UV & Chemical Protection
- Installation & Routing: Use on supported, fixed interconnections between measuring instruments, field junction boxes and monitoring equipment. Where groups need separate screen continuity, carry the group identifiers through every junction.
- Termination & Entry Check: Plan the cabinet entry around the laminate and screen termination details. If the route specification requires steel wire armour, a pressure rating or immersion performance, provide that requirement for a separate construction review.
- Normative Reference (1): The material specifications referenced for this construction are SANS 1411 Part 4, SANS 1411 Part 2 Type B1 and SANS 1411 Part 7. Confirm the edition and required material or test documentation for the order.
- Applicable Standard: The material specifications referenced for this construction are SANS 1411 Part 4, SANS 1411 Part 2 Type B1 and SANS 1411 Part 7. Confirm the edition and required material or test documentation for the order.
EN 50288 / PAS 5308 / Fieldbus Protocol Standards
- Normative Reference (1): The material specifications referenced for this construction are SANS 1411 Part 4, SANS 1411 Part 2 Type B1 and SANS 1411 Part 7. Confirm the edition and required material or test documentation for the order.
- Applicable Standard: The material specifications referenced for this construction are SANS 1411 Part 4, SANS 1411 Part 2 Type B1 and SANS 1411 Part 7. Confirm the edition and required material or test documentation for the order.
- Conductor Specification: Class 2 / Class 5 copper conductor per IEC 60228 / ASTM
- Flame & Environmental Compliance: IEC 60332-1-2 flame propagation & RoHS compliant
Instrumentation & Industrial Bus Guides

APL-Sheathed CAM / ICAM Instrumentation Process Control & Telemetry Topology
This APL-sheathed instrumentation cable is designed for fixed connections between sensors, monitors and control equipment. It uses XLPE-insulated copper conductors with a collective screen, or individual and collective screens, beneath a separate aluminium–polyethylene laminate. The construction gives the buyer two separate decisions to make. First select the signal screen arrangement, then plan how to terminate the outer laminate.
Choose CAM when the circuit schedule calls for a collective screen around the cable assembly. Choose ICAM when the schedule also calls for screens at the individual groups. In a cabinet, the drain serving the laminate must remain identifiable alongside the drains used for the signal screens. Agree the connection points with the designer so the installer can follow the drawing at both ends.
DCS, PLC, Fieldbus & Sensor Network Routes
- Use on supported, fixed interconnections between measuring instruments, field junction boxes and monitoring equipment. Where groups need separate screen continuity, carry the group identifiers through every junction.
- Plan the cabinet entry around the laminate and screen termination details. If the route specification requires steel wire armour, a pressure rating or immersion performance, provide that requirement for a separate construction review.
APL-Sheathed CAM / ICAM Instrumentation Impedance, Grounding & Bus FAQ
What core insulation, bedding, and shielding architecture is built into APL-Sheathed CAM / ICAM Instrumentation Cable?
Conductor and insulation: Stranded annealed bunched copper with XLPE insulation.; CAM: Collective aluminium/polyester tape with a tinned-copper drain.; ICAM: Individual and collective aluminium/polyester tapes with tinned-copper drains.; Bedding: PVC.; APL layer: Aluminium–polyethylene laminate with a separate bunched tinned-copper drain.
How do fixed versus flexed temperature and bending ratings compare on APL-Sheathed CAM / ICAM Instrumentation Cable?
Rated voltage: 300/500 V; Maximum operating temperature: +105 °C; Minimum bend radius: 9 × overall diameter; 1.5 mm² multipair or multitriple maximum conductor resistance at 20 °C: 13.5 Ω/km; 1.5 mm² nominal mutual capacitance: 120 nF/km
What installation conditions and duty cycles is APL-Sheathed CAM / ICAM Instrumentation Cable engineered to serve?
Use on supported, fixed interconnections between measuring instruments, field junction boxes and monitoring equipment. Where groups need separate screen continuity, carry the group identifiers through every junction. Plan the cabinet entry around the laminate and screen termination details. If the route specification requires steel wire armour, a pressure rating or immersion performance, provide that requirement for a separate construction review.
What reference standards define the conductor, dielectric, and flame performance of APL-Sheathed CAM / ICAM Instrumentation Cable?
Normative Reference (1): The material specifications referenced for this construction are SANS 1411 Part 4, SANS 1411 Part 2 Type B1 and SANS 1411 Part 7. Confirm the edition and required material or test documentation for the order.; Applicable Standard: The material specifications referenced for this construction are SANS 1411 Part 4, SANS 1411 Part 2 Type B1 and SANS 1411 Part 7. Confirm the edition and required material or test documentation for the order.; Conductor Specification: Class 2 / Class 5 copper conductor per IEC 60228 / ASTM; Flame & Environmental Compliance: IEC 60332-1-2 flame propagation & RoHS compliant
For the listed two-pair sizes, 9 × diameter gives reference bend radii of 145.8 mm for CAM and 148.5 mm for ICAM. A 100 m one-way two-wire circuit in the listed 1.5 mm² multipair construction contributes up to 2.70 Ω of conductor loop resistance at 20 °C.
TEBAOFLEX® — Reference ratings
| Item | Reference detail |
|---|---|
| Rated voltage | 300/500 V |
| Maximum operating temperature | +105 °C |
| Minimum bend radius | 9 × overall diameter |
| 1.5 mm² multipair or multitriple maximum conductor resistance at 20 °C | 13.5 Ω/km |
| 1.5 mm² nominal mutual capacitance | 120 nF/km |
TEBAOFLEX® — Selected APL CAM and ICAM reference configurations
| Configuration | Nominal OD | Nominal mass |
|---|---|---|
| APL CAM, 1 pair × 1.0 mm² | 10.2 mm | 111 kg/km |
| APL CAM, 2 pairs × 1.5 mm² | 16.2 mm | 248 kg/km |
| APL ICAM, 2 pairs × 1.5 mm² | 16.5 mm | 267 kg/km |
Selection guide: Cable diameter and weight change with the screen arrangement, even at the same pair count and conductor area. Where both versions could work electrically, use the ordered construction to check gland fit, local bend clearance and cable support. Review the cable route at junction boxes where several runs converge.
Ordering & Quotation Checklist: Send the configuration, cable length and installation details for review.