600V ICEA S-73-532 Multi-Conductor Control Cable (PVC, XLPE, LSZH & Armored)
600 V ICEA S-73-532 (NEMA WC 57) and UL 1277 Multi-Conductor Control Cables (2 to 48 conductors, 16 AWG, 14 AWG, 12 AWG & 10 AWG) are engineered with flexible stranded copper conductors across four insulation/jacket systems: 75 °C PVC/PVC, 90 °C PVC-Nylon/PVC (with optional Al/PET foil shield), 90 °C XLPE/PVC (bare or tinned copper), and 90 °C Halogen-Free XLPE/LSZH. Every insulation family is supplied Unarmored.
- Standard designationsICEA S-73-532 / NEMA WC 57, UL 1277 (Type TC), IEC 60332-3-24 Cat. C, IEC 60754 / 61034
- 4 Insulation / Jacket systems75 °C PVC/PVC; 90 °C PVC-Nylon/PVC; 90 °C XLPE/PVC (Bare or Tinned Cu); 90 °C XLPE/LSZH
- Shield & armor optionsUnarmored; Al/PET Foil Shield; Cu-Tape + STA (-W); Double Steel Tape (STA/-F); Steel Wire (SWA/-H)
- Rated voltage & temp.600 V AC; -25 °C to +75 °C (PVC) or +90 °C continuous (+250 °C short-circuit on XLPE)
- ConductorFlexible stranded annealed bare or tinned electrolytic copper, 16 AWG, 14 AWG, 12 AWG & 10 AWG
- Core count & coding2, 3, 4, 5, 7, 9, 12, 19, 25, 30, 37 & 48 conductors; ICEA Method 1/4 color or numbered coding
- Outer sheathSunlight-, oil- and flame-resistant PVC or Thermoplastic Halogen-Free Low-Smoke (LSZH)
- Flame test complianceUL 1277 / IEEE 383 / IEEE 1202 (70,000 BTU/hr) & IEC 60332-3-24 Cat. C vertical tray flame
600V ICEA S-73-532 / NEMA WC 57 Core Identification & Ratings
- Type: PVC Control & Data Cable
- Standard designations: ICEA S-73-532 / NEMA WC 57, UL 1277 (Type TC), IEC 60332-3-24 Cat. C, IEC 60754 / 61034
- 4 Insulation / Jacket systems: 75 °C PVC/PVC; 90 °C PVC-Nylon/PVC; 90 °C XLPE/PVC (Bare or Tinned Cu); 90 °C XLPE/LSZH
- Shield & armor options: Unarmored; Al/PET Foil Shield; Cu-Tape + STA (-W); Double Steel Tape (STA/-F); Steel Wire (SWA/-H
Electrical, Thermal & Mechanical Bend Limits
- Rated voltage & temp.: 600 V AC; -25 °C to +75 °C (PVC) or +90 °C continuous (+250 °C short-circuit on XLPE
- Conductor: Flexible stranded annealed bare or tinned electrolytic copper, 16 AWG, 14 AWG, 12 AWG & 10 AWG
- Core count & coding: 2, 3, 4, 5, 7, 9, 12, 19, 25, 30, 37 & 48 conductors; ICEA Method 1/4 color or numbered coding
- Outer sheath: Sunlight-, oil- and flame-resistant PVC or Thermoplastic Halogen-Free Low-Smoke (LSZH
- Flame test compliance: UL 1277 / IEEE 383 / IEEE 1202 (70,000 BTU/hr) & IEC 60332-3-24 Cat. C vertical tray flame
600V ICEA S-73-532 / NEMA WC 57 Conductor, Insulation & Sheath Build
Engineered to ICEA S-73-532 (NEMA WC 57), this control cable family offers four insulation/jacket chemistries and four mechanical/EMC protection tiers.
- Conductor: Flexible stranded annealed bare electrolytic copper (or tinned copper on MXTC), 16 AWG, 14 AWG, 12 AWG & 10 AWG.
- Core Insulation: 75 °C PVC (MM), 90 °C PVC + Polyamide Nylon (MY/MA), or 90 °C cross-linked polyethylene XLPE (MX/MXTC/ME).
- Inner Jacket & Screen (Optional): Extruded PVC or LSZH inner bedding; 100% Al/PET foil shield (MA) or 100% lapped copper tape screen (-W).
- Metallic Armor (Optional): Double helical galvanized steel tape armor (STA / -F) or single-layer galvanized steel wire armor (SWA / -H).
- Outer Jacket: Sunlight- and oil-resistant flame-retardant PVC (MM/MY/MA/MX) or Halogen-Free Low-Smoke LSZH (ME).
Primary Electrical & Mechanical Performance
- 4 Dielectric platforms under ICEA S-73-532: Choose 75 °C PVC/PVC, 90 °C PVC-Nylon/PVC (unshielded or foil-shielded), 90 °C XLPE/PVC (bare or tinned Cu), or 90 °C Halogen-Free XLPE/LSZH.
- 4 Armor & EMC tiers (-W, STA -F, SWA -H): Available Unarmored for UL 1277 cable trays, Copper-Tape Screened + STA (-W) for HV substations, STA (-F) for direct burial, or SWA (-H) for high tension.
- Flexible bare or tinned copper (16–10 AWG): Fine-stranded copper conductors reduce pulling force and terminal lug stress; tinned copper (MXTC) prevents H2S sulfide blackening in refineries and paper mills.
- 2 to 48 cores with ICEA identification: Cores are identified via ICEA S-73-532 Method 1 (color coding with tracers) or Method 4 (printed numbers) for rapid, error-free field termination.
Industrial Oil, Flame & Environmental Protection
- 70,000 BTU/hr vertical tray flame test: All PVC and LSZH outer jackets pass IEEE 383 / UL 1685 and IEC 60332-3-24 Cat. C bunched vertical flame propagation tests.
- Extruded inner jacket on all armored types: Every -W, STA (-F), and SWA (-H) cable includes a continuous extruded PVC or LSZH inner bedding beneath the metallic screen/armor.
- Tinned copper option (MXTC) for sour gas: Tinned copper conductors resist corrosive hydrogen sulfide (H2S) and coastal salt-fog oxidation at terminal strips.
- Matched 600V power distribution family: Pairs directly with our600V ICEA S-95-658 power cablesand600V ICEA S-73-532 instrumentation cables.
IEC / EN / VDE / UL Reference Standards
- ICEA S-73-532 / NEMA WC 57: Standard for 600 V Control, Thermocouple Extension, and Instrumentation Cables
- UL 1277: 600 V Electrical Power and Control Tray Cables — Type TC) & NEC Article 336
- UL 1685 / IEEE 383 / IEEE 1202 & IEC 60332-3-24 Cat. C: Vertical tray flame propagation
- IEC 60754-1/2 & IEC 61034-2: Zero-halogen acid gas & low smoke emission on XLPE/LSZH ME series
- ASTM B8 / ASTM B33 / IEC 60228: Flexible stranded bare and tinned annealed copper conductors
Industrial Cable Selection & Routing Guides

600V ICEA S-73-532 / NEMA WC 57 Industrial Installation & Routing Guide
Across North and South American power generation plants, mining concentrators, oil refineries, pulp & paper mills, and heavy industrial facilities built to ANSI / NEMA / IEEE standards, 600 V ICEA S-73-532 (NEMA WC 57) is the foundational specification for multi-conductor control cables (16 AWG to 10 AWG, 2 to 48 cores). Unlike stiff 7-strand Class B tray cables, our ICEA S-73-532 industrial control series is manufactured with flexible stranded annealed copper conductors (available in both bare copper and corrosion-resistant tinned copper MXTC) so high-core-count trunks bend smoothly into switchgear marshalling panels.
To match every environmental and fire code, we produce this 600 V control family in four complete dielectric/sheath platforms: (1) 75 °C PVC/PVC (MM) for general indoor/outdoor control trays, (2) 90 °C PVC-Nylon/PVC (MY unshielded & MA 100% Al/PET foil-shielded) for oil/solvent resistance, (3) 90 °C XLPE/PVC (MX bare copper & MXTC tinned copper) for high thermal stability and low dielectric loss, and (4) 90 °C Halogen-Free XLPE/LSZH (ME) for zero-halogen low-smoke safety. Each platform is available Unarmored, Copper-Tape Screened + STA (-W), Double Galvanized Steel Tape Armored (STA / -F), or Galvanized Steel Wire Armored (SWA / -H). Compare with our metric0.6/1 kV IRAM 2178-1 control cablesand600V ICEA S-95-658 power & CSA Teck cables.
Typical Plant, Machine & Infrastructure Circuits
- 600 V ICEA S-73-532 Unarmored & Foil-Shielded (MA) Control Cables (2C to 48C, 16–10 AWG) route inside open ladder trays, conduits, and control rooms to interconnect MCC buckets, breaker trip/close coils, motor space heaters, limit switches, and PLC digital I/O modules.
- 600 V Cu-Tape+STA (-W), STA (-F), and SWA (-H) Armored Control Cables are direct-buried in utility switchyards, tank farms, and heavy industrial trenches where rodent defense, radial crush protection, or 100% copper-tape transient shielding is required.
600V ICEA S-73-532 / NEMA WC 57 Specification & Selection FAQ
How do the four ICEA S-73-532 control cable series (MM, MY/MA, MX/MXTC, and ME) differ?
MM uses 75 °C PVC insulation and a PVC jacket for standard control trays; MY and MA (foil-shielded) use 90 °C PVC-Nylon (THHN/THWN) cores for oil/solvent resistance; MX (bare Cu) and MXTC (tinned Cu) use 90 °C thermoset XLPE insulation (+250 °C short-circuit) with a PVC jacket; and ME pairs 90 °C XLPE insulation with a Halogen-Free Low-Smoke (LSZH) jacket.
When should I specify the MA (Foil-Shielded) vs. -W (Copper-Tape Screened + STA Armored) control cable?
Specify the MA series (100% aluminum-polyester foil shield + tinned copper drain wire inside an unarmored, STA, or SWA jacket) for general industrial EMI protection in cable trays. Specify the -W series (100% helically lapped bare copper tape screen + double galvanized steel tape armor) for high-voltage substations and direct-buried trenches subject to heavy switching transients and fault currents.
Why choose tinned copper conductors (MXTC) on 600 V XLPE/PVC control cables?
In coastal refineries, sour-gas processing plants, wastewater treatment facilities, and pulp/paper bleach plants, airborne hydrogen sulfide (H2S), chlorine, and salt moisture rapidly corrode bare copper wire ends at terminal blocks. Tin-coating each copper strand prevents sulfide corrosion and maintains low contact resistance.
Are these ICEA S-73-532 control cables suitable for open cable trays and direct burial?
Yes. Unarmored variants meet UL 1277 Type TC vertical tray flame, sunlight resistance, and crush criteria for open ladder trays, while STA (-F), SWA (-H), and Cu-Tape+STA (-W) armored variants provide full mechanical protection for direct-buried trenches.
Dimensional, weight, resistance, and ampacity specifications for 600 V ICEA S-73-532 / NEMA WC 57 multi-conductor control cables (16 AWG to 10 AWG, 2 to 37+ cores) across PVC, PVC-Nylon, XLPE/PVC and XLPE/LSZH in Unarmored, Cu-Tape+STA, STA and SWA designs.
TEBAOFLEX® — 600V ICEA S-73-532 Multi-Conductor Control Cable (PVC, XLPE, LSZH & Armored)
| Core Count × Gauge | Insulation Wall XLPE / PVC-Nylon (mils / mm) | Unarmored OD (mm) | Unarmored Weight (kg/km) | STA (-F) / Cu-Tape (-W) OD (mm) | SWA (-H) Armored OD (mm) | SWA Weight (kg/km) | Ampacity 90 °C / 75 °C (A) |
|---|---|---|---|---|---|---|---|
| 2C × 14 AWG | 30 / 0.76 (15+4 Nylon) | 9.4 | 118 | 13.0 | 14.2 | 355 | 25 / 20 |
| 3C × 14 AWG | 30 / 0.76 (15+4 Nylon) | 10.0 | 145 | 13.6 | 14.8 | 395 | 25 / 20 |
| 4C × 14 AWG | 30 / 0.76 (15+4 Nylon) | 10.9 | 180 | 14.6 | 15.8 | 450 | 20 / 16 |
| 5C × 14 AWG | 30 / 0.76 (15+4 Nylon) | 11.9 | 218 | 15.6 | 16.8 | 510 | 20 / 16 |
| 7C × 14 AWG | 30 / 0.76 (15+4 Nylon) | 13.0 | 275 | 16.8 | 18.0 | 595 | 17.5 / 14 |
| 9C × 14 AWG | 30 / 0.76 (15+4 Nylon) | 15.2 | 355 | 19.0 | 20.4 | 735 | 17.5 / 14 |
| 12C × 14 AWG | 30 / 0.76 (15+4 Nylon) | 17.0 | 455 | 21.0 | 22.4 | 895 | 12.5 / 10 |
| 19C × 14 AWG | 30 / 0.76 (15+4 Nylon) | 20.0 | 685 | 24.2 | 25.8 | 1,240 | 12.5 / 10 |
| 25C × 14 AWG | 30 / 0.76 (15+4 Nylon) | 23.4 | 895 | 27.8 | 29.6 | 1,590 | 11.2 / 9.0 |
| 37C × 14 AWG | 30 / 0.76 (15+4 Nylon) | 27.2 | 1,290 | 31.8 | 34.0 | 2,180 | 10.0 / 8.0 |
TEBAOFLEX® — 600V ICEA S-73-532 Multi-Conductor Control Cable (PVC, XLPE, LSZH & Armored)
| Core Count × Gauge | Conductor Area (mm²) | Insulation Wall (mils / mm) | Unarmored OD (mm) | Unarmored Weight (kg/km) | STA (-F) Armored OD (mm) | SWA (-H) Armored OD / Weight (mm / kg/km) | Max. DC Res. 20 °C (Ω/km) |
|---|---|---|---|---|---|---|---|
| 4C × 16 AWG | 1.31 | 30 / 0.76 | 9.8 | 135 | 13.4 | 14.6 / 375 | 14.2 |
| 7C × 16 AWG | 1.31 | 30 / 0.76 | 11.6 | 205 | 15.2 | 16.4 / 485 | 14.2 |
| 12C × 16 AWG | 1.31 | 30 / 0.76 | 15.0 | 335 | 18.8 | 20.2 / 715 | 14.2 |
| 19C × 16 AWG | 1.31 | 30 / 0.76 | 17.6 | 495 | 21.6 | 23.2 / 980 | 14.2 |
| 37C × 16 AWG | 1.31 | 30 / 0.76 | 23.8 | 925 | 28.2 | 30.2 / 1,690 | 14.2 |
| 4C × 12 AWG | 3.31 | 30 / 0.76 | 12.2 | 245 | 15.8 | 17.2 / 550 | 5.6 |
| 7C × 12 AWG | 3.31 | 30 / 0.76 | 14.6 | 385 | 18.4 | 19.8 / 755 | 5.6 |
| 12C × 12 AWG | 3.31 | 30 / 0.76 | 19.2 | 645 | 23.4 | 25.0 / 1,180 | 5.6 |
| 19C × 12 AWG | 3.31 | 30 / 0.76 | 22.6 | 980 | 27.0 | 28.8 / 1,680 | 5.6 |
| 4C × 10 AWG | 5.26 | 30 / 0.76 | 14.2 | 355 | 18.0 | 19.4 / 715 | 3.5 |
| 7C × 10 AWG | 5.26 | 30 / 0.76 | 17.2 | 565 | 21.2 | 22.8 / 1,030 | 3.5 |
| 12C × 10 AWG | 5.26 | 30 / 0.76 | 22.8 | 950 | 27.2 | 29.0 / 1,620 | 3.5 |
Selection guide: Specify 600 V ICEA S-73-532 dielectric/jacket system (75 °C PVC/PVC, 90 °C PVC-Nylon/PVC, 90 °C XLPE/PVC bare or tinned Cu, or 90 °C XLPE/LSZH), shield/armor tier (Unarmored, Foil-Shielded MA, Cu-Tape+STA -W, STA -F, or SWA -H), AWG size (16–10 AWG), and core count (2–48C).
Ordering & Quotation Checklist: Request a factory quotation for 600 V ICEA S-73-532 (NEMA WC 57) multi-conductor control cables in PVC, PVC-Nylon, XLPE/PVC or XLPE/LSZH (Unarmored, Cu-Tape, STA or SWA).
IRAM 2178-1 0.6/1 kV Flexible PVC & XLPE Power & Control Cable (STA/SWA)
IRAM 2178-1 (2015), IEC 60502-1, IRAM NM 280 / IEC 60228 Class 5
600V ICEA S-95-658 Power Cable & CSA C22.2 No. 131 Interlock Armored Cable
ICEA S-95-658 / NEMA WC 70, UL 1277, CSA C22.2 No. 131 (Type Teck / ACWU / Interlock)
600V ICEA S-73-532 / UL 1277 PVC-Nylon Shielded Process Instrumentation Cable
ICEA S-73-532 / NEMA WC 57, UL 1277 (600 V Type TC), UL 62 / UL 83 (THHN/THWN cores)
Request Quotation & Datasheet for This Cable
Need factory pricing, cross-section drawing or a full PDF datasheet for 600V ICEA S-73-532 Multi-Conductor Control Cable (PVC, XLPE, LSZH & Armored)? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.
- ISO 9001 Factory Direct
- MOQ 50 m (Custom Builds)
- 24h Engineering Reply