1SSA6 / 1SSA4 / 7SSA12 / 4SSA40 / 4OMB23 Armored Subsea Tow & Umbilical Cable
The 1SSA6 / 1SSA4 / 7SSA12 / 7SSA26 / 4SSA40 / 4OMB23 series comprises torque-balanced, double contra-helically armored electromechanical (EM) tow, oceanographic CTD, and downhole logging cables. Unlike polymer-sheathed umbilicals, these cables feature an.
- Single-Core Armored Models1SSA6 (5.82 mm OD, 29.0 kN Break) | 1SSA4 (5.69 mm OD, 26.7 kN Break)
- Four-Core Armored Models4SSA40 (10.18 mm OD, 65.0 kN Break) | 4OMB23 (5.92 mm OD, 28.4 kN Break)
- Seven-Core Armored Models7SSA12 (12.00 mm OD, 89 kN Break, 180°C) | 7SSA26 (13.20 mm OD, 105 kN Break, 260°C)
- Armor MaterialDouble Layer Contra-Helically Stranded Galvanized Improved Plow Steel (GIPS) Wires
- Rated Voltage600 V DC / RMS (1SSA6, 1SSA4, 4OMB23) to 1,000 V / 1,500 V (4SSA40, 7SSA12, 7SSA26)
- Insulation SystemsPolypropylene / PE (-40°C to +105°C), ETFE (+180°C on 7SSA12), or FEP (+260°C on 7SSA26)
- Breaking Strength Range26.7 kN (6,000 lbf) up to 105.0 kN (23,600 lbf)
- Supply FormatCustom Cut Lengths, Export Wooden Drums, and OEM Harnessing
1SSA6 / 1SSA4 / 7SSA12 / 4SSA40 / 4OMB23 Submersible & Hydrostatic Profile
- Type: Subsea & ROV Umbilical Cables
- Single-Core Armored Models: 1SSA6 (5.82 mm OD, 29.0 kN Break) | 1SSA4 (5.69 mm OD, 26.7 kN Break
- Four-Core Armored Models: 4SSA40 (10.18 mm OD, 65.0 kN Break) | 4OMB23 (5.92 mm OD, 28.4 kN Break
- Seven-Core Armored Models: 7SSA12 (12.00 mm OD, 89 kN Break, 180°C) | 7SSA26 (13.20 mm OD, 105 kN Break, 260°C
Immersion Depth, Pressure & Thermal Ratings
- Armor Material: Double Layer Contra-Helically Stranded Galvanized Improved Plow Steel (GIPS) Wires
- Rated Voltage: 600 V DC / RMS (1SSA6, 1SSA4, 4OMB23) to 1,000 V / 1,500 V (4SSA40, 7SSA12, 7SSA26
- Insulation Systems: Polypropylene / PE (-40°C to +105°C), ETFE (+180°C on 7SSA12), or FEP (+260°C on 7SSA26
- Breaking Strength Range: 26.7 kN (6,000 lbf) up to 105.0 kN (23,600 lbf
- Supply Format: Custom Cut Lengths, Export Wooden Drums, and OEM Harnessing
1SSA6 / 1SSA4 / 7SSA12 / 4SSA40 / 4OMB23 Water-Blocked Core & Sheath Architecture
Each electromechanical cable is manufactured on precision planetary armor-stranding lines with pre-formed GIPS steel wires so the armor stays tightly closed when cut.
- Conductors: 19-strand or 7-strand tinned or bare copper conductors (15 AWG to 22 AWG) laid concentrically.
- Primary Insulation: Extruded Polypropylene (1SSA4, 4OMB23), Polyethylene (4SSA40), ETFE (7SSA12, +180°C), or FEP (7SSA26, +260°C).
- Bedding & Void Fillers: Water-blocking compound, polyester tape wrap, and steel/glass interstices fillers (on 7SSA series) maintaining round core geometry under armor compression.
- Inner Armor Layer: 12 to 20 helically applied Galvanized Improved Plow Steel (GIPS) wires.
- Outer Armor Layer: 15 to 20 contra-helically applied GIPS steel wires pre-formed to balance rotational torque under tension.
Hydrostatic Integrity & Tensile Load Performance
- Core Configurations: 1-Core (1SSA), 4-Core (4SSA/4OMB), 7-Core (7SSA
- Armor Construction: Double Contra-Helical GIPS Steel Wire
- Breaking Strength: 26.7 kN to 105.0 kN (Torque-Balanced
- Thermal Ratings: +105°C (PP/PE), +180°C (ETFE), +260°C (FEP
Potable Water, Seawater, Slurry & Chlorine Resistance
- Torque-Balanced Double Contra-Helical GIPS Armor:: Opposing lay directions between the inner and outer galvanized improved plow steel wire layers neutralize rotational torque under load, preventing tow-fish spin and cable kinking.
- Water-Blocked Core & Armor Interstices:: Void-filling water-blocking compounds and high-temperature glass/steel void fillers prevent gas migration and hydrostatic core collapse.
- Standard (+105°C) to Extreme (+180°C / +260°C) Insulation:: Polypropylene/PE insulation serves oceanographic towing (-40°C to +105°C), while ETFE (7SSA12, +180°C) and fluoropolymer FEP (7SSA26, +260°C) handle geothermal and deep well logging.
- Complete Mechanical Winch Design Data:: Every model includes verified breaking strength, bending stiffness, weight in air vs. water, and minimum sheave diameter.
AD8 / KTW / ACS / Subsea Immersion Standards
- API / Wireline & Oceanographic EM Cable Standard: Dimensional, breaking load, and electrical capacitance uniformity.
- ASTM A640 / Galvanized Improved Plow Steel (GIPS): High-tensile zinc-coated carbon steel armor wire.
- ASTM B33 / IEC 60228: Stranded tinned and bare copper instrumentation conductors.
- High-Temperature Fluoropolymer Insulation (7SSA12 / 7SSA26): ETFE (+180°C) and FEP (+260°C) thermal stability.
Submersible Pump & Subsea Cable Guides

1SSA6 / 1SSA4 / 7SSA12 / 4SSA40 / 4OMB23 Deep-Well, Dewatering & Subsea Deployment
The 1SSA6 / 1SSA4 / 7SSA12 / 7SSA26 / 4SSA40 / 4OMB23 series comprises torque-balanced, double contra-helically armored electromechanical (EM) tow, oceanographic CTD, and downhole logging cables. Unlike polymer-sheathed umbilicals, these cables feature an exposed outer armor of Galvanized Improved Plow Steel (GIPS) wires applied in two opposing helical layers (inner + outer armor) directly over the insulated conductor core assembly, enabling high-speed winching under extreme axial tension up to 105 kN.
For single-conductor coaxial-return oceanographic CTD profilers, acoustic releases, and slimline logging tools, 1SSA6 (15 AWG / 1.73 mm², 5.82 mm OD, 29.0 kN breaking strength) and 1SSA4 (16 AWG / 1.38 mm², 5.69 mm OD, 26.7 kN breaking strength) use the contra-helical steel armor as both the load-bearing tow member and the electrical return path. For multi-channel side-scan sonar tow-fishes, deepwater camera sleds, and high-temperature downhole intervention, 4OMB23 (4×22 AWG, 5.92 mm OD, 28.4 kN) and 4SSA40 (4×16 AWG, 10.18 mm OD, 65.0 kN) provide balanced 4-quad symmetry, while 7SSA12 (7×20 AWG, ETFE insulated for +180°C, 12.0 mm OD, 89 kN) and 7SSA26 (7×18 AWG, FEP insulated for +260°C, 13.2 mm OD, 105 kN) deliver 7-conductor power and telemetry capacity. For polymer-sheathed ROV coaxial tethers, see ourPCX50 / PCX75 / P-HFCX Subsea Coaxial CableandDUR06-ND / CDUR-01 Subsea Umbilical.
Submersible Pumps, ROVs & Wet-Well Systems
- When towing deepwater side-scan sonars, magnetometers, sub-bottom profilers, or lowering oceanographic CTD rosettes to 6,000 meters, hydrodynamic drag and suspended cable weight generate tens of kilonewtons of tension. Synthetic fiber braids have too large a cross-section, increasing water drag and requiring massive winch drums.
- Contra-helical GIPS steel armor in the 1SSA, 4SSA, 4OMB, and 7SSA series achieves maximum breaking load in a minimum outer diameter (5.69 mm to 13.20 mm), cutting hydrodynamic drag while resisting fish bites, coral abrasion, and high hydrostatic pressure.
1SSA6 / 1SSA4 / 7SSA12 / 4SSA40 / 4OMB23 Immersion Depth & Sealing FAQ
What is the difference between 1SSA6 and 1SSA4 single-conductor armored cables?
1SSA6 uses a 15 AWG (1.73 mm2, 10.7 Ohm/km) conductor with a 12+18 wire (0.96 mm) GIPS armor (5.82 mm OD, 29.0 kN breaking strength). 1SSA4 uses a slightly smaller 16 AWG (1.38 mm2, 13.5 Ohm/km) conductor with a 15×0.81 mm + 15×1.10 mm GIPS armor (5.69 mm OD, 26.7 kN breaking strength) matching standard 7/32-inch (0.224 in) oceanographic CTD and logging sheaves.
When should I choose 4SSA40 versus 4OMB23 for 4-conductor towing?
4OMB23 (5.92 mm OD, 4×22 AWG, 28.4 kN break) is a compact 1/4-inch class 4-conductor cable for lightweight CTD profilers and downhole sensors. 4SSA40 (10.18 mm OD, 4×16 AWG, 65.0 kN break) provides 3.3 times the copper cross-section (14.5 Ohm/km vs 48 Ohm/km) and more than double the breaking load for heavy deepwater sonar tow-fishes.
Why are 7SSA12 and 7SSA26 insulated with ETFE and FEP?
7-conductor electromechanical cables are frequently deployed in both deepwater geophysical towing and high-temperature cased-hole oil/gas/geothermal logging. ETFE on 7SSA12 supports continuous operation up to +180°C, while FEP on 7SSA26 supports extreme downhole temperatures up to +260°C.
Can an outer polyurethane (PUR) or HDPE jacket be extruded over the steel armor?
Yes. Any 1SSA, 4OMB, 4SSA, or 7SSA armored cable can be supplied either with bare GIPS steel armor for standard Lebus winch spooling or with an extruded outer HDPE or polyether PUR corrosion barrier.
Complete mechanical, electrical, and armor stranding data below are compiled directly from TEBAOFLEX datasheets #45, #46, #66, #68, #84, and #99.
TEBAOFLEX® — 1SSA6, 1SSA4, 4OMB23, 4SSA40, 7SSA12 & 7SSA26 Electromechanical Armored Cable Specifications
| Model (Datasheet #) | Conductors × Gauge | Insulation & Temp. Rating | Contra-Helical GIPS Armor (Inner + Outer) | Nominal OD (mm) | Min. Breaking Strength | Weight in Air / Water (kg/km) |
|---|---|---|---|---|---|---|
| 1SSA4 (#46) | 1 × 16 AWG (19/0.305 mm TC) | Polypropylene (-40°C to +105°C) | 15 × 0.81 mm + 15 × 1.10 mm GIPS | 5.69 ± 0.15 mm | 26.7 kN (2,720 kgf) | 128 kg/km Air / 102 kg/km Water |
| 1SSA6 (#45) | 1 × 15 AWG (19/0.34 mm Cu) | Perfluoroalkoxy / PP (+105°C) | 12 × 0.96 mm + 18 × 0.96 mm GIPS | 5.82 mm | 29.0 kN (2,950 kgf) | 145 kg/km Air / 120 kg/km Water |
| 4OMB23 (#84) | 4 × 22 AWG (7/0.26 mm TC) | Polypropylene (-40°C to +105°C) | 18 × 0.72 mm + 18 × 0.96 mm GIPS | 5.92 mm | 28.4 kN (2,900 kgf) | 134 kg/km Air / 105 kg/km Water |
| 4SSA40 (#68) | 4 × 16 AWG (19/0.30 mm TC) | Polyethylene (-40°C to +90°C) | 18 × 1.18 mm + 18 × 1.50 mm GIPS | 10.18 mm | 65.0 kN (6,630 kgf) | 399 kg/km Air / 320 kg/km Water |
| 7SSA12 (#66) | 7 × 20 AWG (19/0.21 mm TC) | ETFE Fluoropolymer (+180°C) | 20 × 1.25 mm + 20 × 1.60 mm GIPS | 12.00 mm | 89.0 kN (9,075 kgf) | 547 kg/km Air / 435 kg/km Water |
| 7SSA26 (#99) | 7 × 18 AWG (19/0.26 mm TC) | FEP Fluoropolymer (+260°C) | 20 × 1.38 mm + 20 × 1.75 mm GIPS | 13.20 mm | 105.0 kN (10,700 kgf) | 660 kg/km Air / 534 kg/km Water |
TEBAOFLEX® — Electrical & Sheave Design Parameters (1SSA, 4OMB, 4SSA & 7SSA Series)
| Model Designation | Voltage Rating (DC / RMS) | Conductor DC Resistance @ 20°C | Armor DC Resistance @ 20°C | Capacitance (Cond.–Armor / Cond.–Cond.) | Insulation Resistance | Min. Recommended Sheave Dia. |
|---|---|---|---|---|---|---|
| 1SSA4 (#46) | 600 V | 13.5 Ω/km | 9.2 Ω/km | 138 pF/m (Cond. to Armor) | >= 3,000 MΩ·km | 280 mm |
| 1SSA6 (#45) | 600 V | 10.7 Ω/km | 8.2 Ω/km | 177 pF/m (Cond. to Armor) | >= 1,500 MΩ·km | 300 mm |
| 4OMB23 (#84) | 600 V | 48.0 Ω/km | 10.2 Ω/km | 98 pF/m (C–C) | >= 3,000 MΩ·km | 300 mm |
| 4SSA40 (#68) | 1,000 V | 14.5 Ω/km | 4.0 Ω/km | 85 pF/m (C–C) / 145 pF/m (C–A) | >= 3,000 MΩ·km | 460 mm |
| 7SSA12 (#66) | 1,000 V | 29.5 Ω/km | 3.2 Ω/km | 130 pF/m | >= 1,500 MΩ·km | 550 mm |
| 7SSA26 (#99) | 1,500 V | 19.0 Ω/km | 2.6 Ω/km | 115 pF/m | >= 1,500 MΩ·km | 610 mm |
Selection guide: Maximum continuous working tension is typically 50% of minimum breaking strength. Pre-seasoning tensioning and corrosion-inhibiting lubrication are applied during manufacturing. For topside and shipboard routing on support vessels, compareJIS C 3410 DPYC, TPYC, MPYC, and TTYC marine shipboard cablesandType LSX 1 kV and 2 kV armored offshore cables, or read ourshielded vs armored cable guide.
Ordering & Quotation Checklist: Specify your required model (1SSA4, 1SSA6, 4OMB23, 4SSA40, 7SSA12, or 7SSA26), continuous unbroken reel length (up to 6,000 m+), and sheave size for an engineering quotation.
2GAX / 4GAX / 6GAX / 8GAX / DLRB-3TP6C Buoyant ROV Tether & DataLine Cable
2GAX160 / 4GAX161 / 6GAX162 / 8GAX163 / 4GAX181 | DLRB-3TP6C | DATALINE ROV
CDUR-06 14-Core Subsea Diving & ROV Umbilical Cable with 75 Ω Coax
CDUR-06 (replaces CDUR-05)
DLR Series 4 to 10-Core Underwater Video & Power ROV Tether Cable
DLR-1P20, 2P20, 3P25, 4P25
Request Quotation & Datasheet for This Cable
Need factory pricing, cross-section drawing or a full PDF datasheet for 1SSA6 / 1SSA4 / 7SSA12 / 4SSA40 / 4OMB23 Armored Subsea Tow & Umbilical Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.
- ISO 9001 Factory Direct
- MOQ 50 m (Custom Builds)
- 24h Engineering Reply