Outdoor Water-Blocked Industrial Ethernet Cable

Outdoor water-blocked industrial Ethernet cable combines environmental protection with a defined balanced data construction for exposed equipment and underground network routes. Selected installation conductors: Solid AWG23/1; four pairs Selected insulation diameter: 1.4 mm nominal PUR installation / flexible water protection: Longitudinal PA12 / PE burial protection: Radial water protection.

  • Selected installation conductorsSolid AWG23/1; four pairs
  • Selected insulation diameter1.4 mm nominal
  • PUR installation / flexible water protectionLongitudinal
  • PA12 / PE burial protectionRadial water protection; dielectric rodent / termite protection
  • Listed PUR, PVC and PA12/PE service temperature-40 to +80 °C for the corresponding specified builds
  • PVC AWM optionUL AWM Style 20963; 30 V
  • Outdoor Cat7 PE / aluminum-PE optionsAWG23/1 S/FTP; 100 Ω nominal; 8 × D during installation and 4 × D fixed
  • ConstructionConductor / jacket

Outdoor Water-Blocked Industrial Ethernet Submersible & Hydrostatic Profile

  • Type: Industrial Cables
  • Selected installation conductors: Solid AWG23/1; four pairs
  • Selected insulation diameter: 1.4 mm nominal
  • PUR installation / flexible water protection: Longitudinal

Immersion Depth, Pressure & Thermal Ratings

  • PA12 / PE burial protection: Radial water protection; dielectric rodent / termite protection
  • Listed PUR, PVC and PA12/PE service temperature: -40 to +80 °C for the corresponding specified builds
  • PVC AWM option: UL AWM Style 20963; 30 V
  • Outdoor Cat7 PE / aluminum-PE options: AWG23/1 S/FTP; 100 Ω nominal; 8 × D during installation and 4 × D fixed
  • Construction: Conductor / jacket

Outdoor Water-Blocked Industrial Ethernet Water-Blocked Core & Sheath Architecture

The illustrated section is the solid AWG23 PUR construction with four individually screened pairs and an overall braid. The PA12/PE burial option uses a different protective system and is specified separately.

  • Selected PUR installation build: Solid bare copper AWG23/1; nominal conductor diameter 0.56 mm.
  • Selected insulation: Foam-skin PE; nominal insulated core diameter 1.4 mm.
  • Selected screen / assembly: Four individually screened pairs, overall braid and nonwoven wrapping.
  • Selected outer sheath: PUR; longitudinal water-blocking construction; nominal OD 7.5 mm.
  • Flexible PUR option: AWG26/7, foam-skin PE, overall foil/braid screen, nonwoven wrap; longitudinal water blocking.
  • PA12 / PE burial option: Solid bare AWG24/1, solid PE insulation, four pairs with swellable yarns, PA12 barrier and PE outer; screened and UTP versions.
  • Screened PVC option: AWG26/7, foam-skin PE, individual pair screens and overall braid.

Hydrostatic Integrity & Tensile Load Performance

  • Installation and connection: Protect exposed transitions and use sealing components matched to the complete cable diameter and jacket.
  • Keep water direction and movement duty explicit: The 7.5 mm PUR installation build and the 6.4 mm stranded PUR option both have listed longitudinal water protection, but they use different conductor formats and mechanical duties.
  • Outdoor Cat7 PE / aluminum-PE options: AWG23/1 S/FTP; 100 Ω nominal; 8 × D during installation and 4 × D fixed
  • Construction: Conductor / jacket

Potable Water, Seawater, Slurry & Chlorine Resistance

  • Selection point: Information to specify
  • Water path: Longitudinal or radial requirement and joint locations
  • Burial protection: Soil, biological exposure, ducting and ground transitions
  • Data channel: Category, rate, length and termination hardware

AD8 / KTW / ACS / Subsea Immersion Standards

  • Reference / performance: Applicable condition
  • Longitudinal water protection: Specified PUR installation and flexible constructions.
  • Radial water / biological protection: Specified PA12/PE direct-burial construction.
  • UL AWM Style 20963 / FT2 / IEC 60332-1: Screened AWG26/7 PVC option only; 30 V marking.
  • ISO/IEC 11801 / EN 50173 / IEC 61156-5: Outdoor Cat.7 PE and aluminum-PE structured-cabling options.

Submersible Pump & Subsea Cable Guides

Outdoor solar-farm communication wiring in its equipment environment
Equipment environment and supported cable routing for the stated application. Select the actual cable and connection for the installation duty.

Outdoor Water-Blocked Industrial Ethernet Deep-Well, Dewatering & Subsea Deployment

Outdoor water-blocked industrial Ethernet cable combines environmental protection with a defined balanced data construction for exposed equipment and underground network routes. The selected longitudinally water-blocked PUR build uses four solid-copper AWG23 pairs, foam-skin PE insulation, individual pair screens and an overall braid beneath the outer sheath.

Select water protection by its direction and construction. Longitudinal water blocking addresses propagation along the cable, while the PA12/PE direct-burial alternative has a distinct radial protection system with swellable yarns and a dielectric biological barrier. The range also includes a stranded PUR chain option and a separately rated screened PVC construction.

Submersible Pumps, ROVs & Wet-Well Systems

  • For outdoor industrial Ethernet, energy-field communication, wet equipment routes and the specified direct-burial or moving-chain network applications.
  • Selection point: Information to specify
  • Water path: Longitudinal or radial requirement and joint locations
  • Burial protection: Soil, biological exposure, ducting and ground transitions
  • Data channel: Category, rate, length and termination hardware

Installation and connection

Protect exposed transitions and use sealing components matched to the complete cable diameter and jacket. Include connector and joint requirements when reviewing the installed water-protection system.

Outdoor Water-Blocked Industrial Ethernet Immersion Depth & Sealing FAQ

What is the engineering rule regarding 'installation and connection' on Outdoor Water-Blocked Industrial Ethernet Cable?

Protect exposed transitions and use sealing components matched to the complete cable diameter and jacket. Include connector and joint requirements when reviewing the installed water-protection system.

How does Outdoor Water-Blocked Industrial Ethernet Cable handle keep water direction and movement duty explicit in field installations?

The 7.5 mm PUR installation build and the 6.4 mm stranded PUR option both have listed longitudinal water protection, but they use different conductor formats and mechanical duties. The PA12/PE burial option adds a separate radial and biological protection system. Select those properties together with the actual network interface.

Which conductor stranding, core identification, and jacket compounds are used in Outdoor Water-Blocked Industrial Ethernet Cable?

Selected PUR installation build: Solid bare copper AWG23/1; nominal conductor diameter 0.56 mm.; Selected insulation: Foam-skin PE; nominal insulated core diameter 1.4 mm.; Selected screen / assembly: Four individually screened pairs, overall braid and nonwoven wrapping.; Selected outer sheath: PUR; longitudinal water-blocking construction; nominal OD 7.5 mm.; Flexible PUR option: AWG26/7, foam-skin PE, overall foil/braid screen, nonwoven wrap; longitudinal water blocking.

Which electrical, thermal, and mechanical operating limits govern Outdoor Water-Blocked Industrial Ethernet Cable?

Selected installation conductors: Solid AWG23/1; four pairs; Selected insulation diameter: 1.4 mm nominal; PUR installation / flexible water protection: Longitudinal; PA12 / PE burial protection: Radial water protection; dielectric rodent / termite protection; Listed PUR, PVC and PA12/PE service temperature: -40 to +80 °C for the corresponding specified builds

Nominal selection data for the listed constructions. D means the finished cable outside diameter. Match the complete configuration and test conditions to the ordered cable.

TEBAOFLEX® — Outdoor Water-Blocked Industrial Ethernet Cable technical parameters

Outdoor Water-Blocked Industrial Ethernet Cable technical parameters
Parameter Value / condition
Selected installation conductors Solid AWG23/1; four pairs
Selected insulation diameter 1.4 mm nominal
PUR installation / flexible water protection Longitudinal
PA12 / PE burial protection Radial water protection; dielectric rodent / termite protection
Listed PUR, PVC and PA12/PE service temperature -40 to +80 °C for the corresponding specified builds
PVC AWM option UL AWM Style 20963; 30 V
Outdoor Cat7 PE / aluminum-PE options AWG23/1 S/FTP; 100 Ω nominal; 8 × D during installation and 4 × D fixed

TEBAOFLEX® — Outdoor network cable options

Outdoor network cable options
Construction Conductor / jacket Nominal OD (mm)
Longitudinal water-blocked Cat.5e/6 installation Solid AWG23/1 / PUR 7.5
Longitudinal water-blocked flexible option AWG26/7 / PUR 6.4
Screened PVC option AWG26/7 / PVC 6.3
Outdoor Cat.7 PE Solid AWG23/1 / black PE 7.7
Transversely waterproof outdoor Cat.7 Solid AWG23/1 / aluminum-PE protective system 9.6

Keep water direction and movement duty explicit

The 7.5 mm PUR installation build and the 6.4 mm stranded PUR option both have listed longitudinal water protection, but they use different conductor formats and mechanical duties. The PA12/PE burial option adds a separate radial and biological protection system. Select those properties together with the actual network interface.

TEBAOFLEX® — Cat.5e 4-Pair (1 Gbps / 100 MHz) SWA, GSWB & External PE Industrial Ethernet Builds

Cat.5e 4-pair Class 1 solid copper SWA GSWB and external PE industrial Ethernet options
Construction Conductor / Insulation Screening & Bedding / Armour Outer Sheath & Colour Nominal OD / Mass Min. Bend / Temp / Standards
Cat.5e FTP 4-Pair SWA PVC Class 1 Solid Cu (24 AWG) / HDPE (0.22 mm wall) Al Foil + TC Drain / PVC Bedding / Galvanised SWA Black PVC (1.4 mm nominal wall) 11.80 mm / 240 kg/km 8 × OD; -20 to +60 °C; IEC 11801, YD/T 1019, TIA/EIA 568
Cat.5e FTP 4-Pair GSWB LSZH Class 1 Solid Cu (24 AWG) / HDPE Al Foil + TC Drain / LSZH Bedding / Galvanised Steel Wire Braid (GSWB) Black LSZH (Low Smoke Zero Halogen) 9.30 mm / 125 kg/km 6 × OD; -20 to +60 °C; BS EN/IEC 60332-1-2, IEC 11801, TIA/EIA 568
Cat.5e UTP 4-Pair SWA LSZH Class 1 Solid Cu (24 AWG) / HDPE Unshielded pairs / LSZH Inner & Bedding / Galvanised SWA Black LSZH (Low Smoke Zero Halogen) 12.90 mm / consult datasheet 8 × OD; -20 to +60 °C; BS EN/IEC 60332-1-2, IEC 11801, TIA/EIA 568
Cat.5e UTP 4-Pair External PE Class 1 Solid Cu (24 AWG) / HDPE Unarmoured duct build (optional foil screen available) UV-resistant Black PE Consult size sheet 8 × OD; -20 to +60 °C; IEC 11801, TIA/EIA 568

Distinguishing water-blocked PUR / Cat.7 builds from mechanically armored SWA/GSWB Cat.5e

Where external industrial Ethernet runs face backfill crush, rodent attack or unlined cable trenches rather than hydrostatic immersion, choose the Class 1 24 AWG Cat.5e 100 MHz (1 Gbps) SWA PVC (11.80 mm), SWA LSZH (12.90 mm) or compact 6 × OD GSWB LSZH (9.30 mm) builds above. Continue specifying the 7.5 mm / 6.4 mm PUR or 7.7 mm / 9.6 mm PA12-Al-PE builds where continuous longitudinal or radial water blocking is required.

Selection guide: A water-blocked cable still needs compatible joints and equipment entries. Specify the complete protective system and the required channel performance together. Keep the listed flame and AWM marking of the PVC option separate from the outdoor PUR and PE constructions.

Ordering & Quotation Checklist: Send the complete configuration, circuit requirements, length, quantity, installation duty and required test documents. Include the equipment drawing and the relevant environmental or movement conditions.

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for Outdoor Water-Blocked Industrial Ethernet Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.

  • ISO 9001 Factory Direct
  • MOQ 50 m (Custom Builds)
  • 24h Engineering Reply
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    You may also like…

    Outdoor Water-Blocked Industrial Ethernet CableGet A Quote