1.8/3 kV Dynamic Marine Power and Fiber Cable
1.8/3 (3.6) kV marine power-and-fiber cable for water-installed connections to moving marine equipment. Three Class 5 tinned-copper power cores plus 12 optical fibers. TPEE insulation, aramid yarn fill and yellow PUR sheath. RJIT-O-type configurations: 3 × 50 to 3 × 185 mm². Maximum continuous conductor temperature: 90°C. Minimum bend radius: 8 × finished cable diameter. Unscreened, unarmored build; separate PE/bonding design.
- Rated voltage U₀/U (Uₘ)1.8/3 (3.6) kV
- Power / optical arrangementThree power cores +12 optical fibers
- Conductor class / materialIEC 60228 Class 5 annealed tinned copper
- Core insulation / sheathTPEE / yellow PUR
- Maximum continuous conductor temperature90°C
- Maximum short-circuit conductor temperature250°C
- Minimum laying temperature−10°C
- Minimum storage temperature−40°C
1.8/3 kV Dynamic Marine Power and Fiber Shipboard & Offshore Identification
- Type: Industrial Cables
- Rated voltage U₀/U (Uₘ): 1.8/3 (3.6) kV
- Power / optical arrangement: Three power cores +12 optical fibers
- Conductor class / material: IEC 60228 Class 5 annealed tinned copper
Marine Electrical, Temperature & Bend Ratings
- Core insulation / sheath: TPEE / yellow PUR
- Maximum continuous conductor temperature: 90°C
- Maximum short-circuit conductor temperature: 250°C
- Minimum laying temperature: −10°C
- Minimum storage temperature: −40°C
1.8/3 kV Dynamic Marine Power and Fiber Halogen-Free / Armored Architecture
The representative 3 × 50 mm² build has three equal power cores in triangular packing, one small central 12-fiber optical unit and aramid yarn in the interstices. A yellow polyurethane sheath encloses the complete assembly.
- Power conductors: Three round Class 5 annealed tinned-copper conductors
- Core insulation / identification: Thermoplastic polyester elastomer (TPEE); brown, black and gray
- Internal fill: Aramid yarn
- Optical unit: One nanocable containing 12 optical fibers
- Outer sheath: Yellow polyurethane (PUR
- Metallic protection / PE: No overall metallic screen or armor; no green/yellow power core
Keep the optical unit distinct from a power core
The central nanocable contains twelve optical fibers; it is not a fourth electrical conductor. Separate optical splicing and bend protection from power termination work, and allow space for both services at the equipment interface.
Match the conductor class to the ordered build
The dimensions and electrical tables below apply to Class 5 tinned copper. A Class 6 requirement needs a separately matched conductor, terminal and dimensional review. Include the conductor class and the complete power-plus-fiber arrangement in the inquiry.
Specify the inspection and acceptance schedule
Include the required material declarations and project inspection documents with the inquiry. For the regulatory background to substance information, see the European Commission REACH overview .
- Electrical inspection and dimensional checks for the ordered power-core size and finished assembly.
- Optical continuity and attenuation requirements at the specified wavelengths and interfaces.
- Water-exposure and mechanical-duty requirements, including pressure, movement, restraints and acceptance criteria.
- Required reaction-to-fire class and any additional smoke, halogen or circuit-integrity requirement for enclosed route sections.
Shipboard Fire Integrity & EMC Performance
- Keep the optical unit distinct from a power core: The central nanocable contains twelve optical fibers; it is not a fourth electrical conductor.
- Match the conductor class to the ordered build: The dimensions and electrical tables below apply to Class 5 tinned copper.
- Specify the inspection and acceptance schedule: Include the required material declarations and project inspection documents with the inquiry.
- Describe each part of the route: Use separate mooring and structural supports for the platform.
Salt Fog, Mud, Oil & Low-Smoke Resistance
- Choose the right type of combined cable: A power-plus-fiber construction does not define every umbilical duty.
- Nominal dimensions and cable mass: On narrow screens, scroll the data tables horizontally to see all columns.
- Electrical reference values: The current values above are air references.
- Check bend clearance for a selected size: Minimum bend radius = 8 × finished cable OD.
IEC 60092 / NEK 606 / BS Marine Standards
- Electrical inspection and dimensional checks for the ordered power-core size and finished assembly.
- Optical continuity and attenuation requirements at the specified wavelengths and interfaces.
- Water-exposure and mechanical-duty requirements, including pressure, movement, restraints and acceptance criteria.
- Required reaction-to-fire class and any additional smoke, halogen or circuit-integrity requirement for enclosed route sections.
- Reference / classification: Application to the selected construction
Marine & Offshore Cable Engineering Guides
Factory Sample & Cut-Section Verification
TEBAOFLEX Production Sample
Authentic TEBAOFLEX workshop cut-end and stripped sample photographs of 1.8/3 kV dynamic marine composite 3-core power and optical fiber hybrid cable, documenting actual conductor stranding, radial wall concentricity, and outer jacket extrusion prior to reel dispatch.




1.8/3 kV Dynamic Marine Power and Fiber Vessel, Platform & FPSO Routing
This 1.8/3 kV dynamic marine power and fiber cable combines three Class 5 tinned-copper power cores with a 12-fiber nanocable inside one yellow PUR sheath. TPEE core insulation and aramid yarn fill complete the round, unarmored construction for water-installed connections to moving marine stations and platforms.
The power and optical elements share a route but perform separate jobs. The three brown, black and gray cores carry the power circuit; the small optical unit provides twelve fibers for the specified communications link. Protective-conductor and bonding arrangements are defined separately in the installation design.
Shipboard Systems & Offshore Zone Coverage
- For permanent water-installed power and communications connections to moving marine stations, platforms and marine-energy equipment. Define the cable span, mechanical restraints and equipment interfaces as one installation.
Describe each part of the route
Use separate mooring and structural supports for the platform. The cable and its entries require their own load assessment and restraint arrangement. Identify any contact with deck edges, seabed material or other lines before selecting protection.
Choose the right type of combined cable
A power-plus-fiber construction does not define every umbilical duty. Hydraulic services, added control pairs, tow strength or metallic screening require their own cable arrangement. Compare the related products below by services, voltage and mechanical protection. The screening and armor selection guide explains the different tasks of electrical screening and mechanical protection.
Specify the required fiber type, operating wavelength, optical equipment, termination or splice method and allowable link loss. Include both installation handling and the movement of the finished cable; the twelve-fiber count alone does not define link performance.
Provide the full movement and load schedule: free cable length, bend range, axial tension, twist, temperature, cycle definition and required inspections. A minimum bend radius is a geometry limit, not a fatigue-life calculation.
1.8/3 kV Dynamic Marine Power and Fiber Marine & Offshore Technical FAQ
What optical information belongs in the inquiry?
Specify the required fiber type, operating wavelength, optical equipment, termination or splice method and allowable link loss. Include both installation handling and the movement of the finished cable; the twelve-fiber count alone does not define link performance.
What defines a dynamic-service requirement?
Provide the full movement and load schedule: free cable length, bend range, axial tension, twist, temperature, cycle definition and required inspections. A minimum bend radius is a geometry limit, not a fatigue-life calculation.
RJIT-O-type 3 × 50 mm² — bend-clearance check
Nominal OD 40 mm × 8 = 320 mm minimum bend radius . The corresponding bend diameter is 640 mm. Nominal dry cable mass is 2.3 kg/m.
RJIT-O-type 3 × 95 mm² — bend-clearance check
Nominal OD 47 mm × 8 = 376 mm minimum bend radius . The corresponding bend diameter is 752 mm. Nominal dry cable mass is 3.6 kg/m.
RJIT-O-type 3 × 120 mm² — bend-clearance check
Nominal OD 50 mm × 8 = 400 mm minimum bend radius . The corresponding bend diameter is 800 mm. Nominal dry cable mass is 4.4 kg/m.
RJIT-O-type 3 × 150 mm² — bend-clearance check
Nominal OD 54 mm × 8 = 432 mm minimum bend radius . The corresponding bend diameter is 864 mm. Nominal dry cable mass is 5.3 kg/m.
Selection values for the Class 5 three-power-core construction with a 12-fiber nanocable. D means the finished cable outside diameter. Conductor, laying and storage temperatures refer to different conditions. Include actual water and air temperatures in the installation specification. The installation pulling-stress limit does not define an offshore working tension or mooring load.
TEBAOFLEX® — 1.8/3 kV dynamic marine power and fiber cable parameters
| Parameter | Value / condition |
|---|---|
| Rated voltage U₀/U (Uₘ) | 1.8/3 (3.6) kV |
| Power / optical arrangement | Three power cores +12 optical fibers |
| Conductor class / material | IEC 60228 Class 5 annealed tinned copper |
| Core insulation / sheath | TPEE / yellow PUR |
| Maximum continuous conductor temperature | 90°C |
| Maximum short-circuit conductor temperature | 250°C |
| Minimum laying temperature | −10°C |
| Minimum storage temperature | −40°C |
| Minimum bending radius | 8 × D |
| Maximum installation pulling stress | 30 N/mm² |
| Listed conductor areas | 50, 95, 120, 150 and 185 mm² per power core |
TEBAOFLEX® — Class 5 three-core marine power cable dimensions, with 12 optical fibers
| Design / configuration (mm²) | Conductor diameter (mm) | Diameter over insulation (mm) | Cable OD (mm) | Cable mass (kg/km) |
|---|---|---|---|---|
| RJIT-O-type 3 × 50 | 9.5 | 14.5 | 40 | 2300 |
| RJIT-O-type 3 × 95 | 12.8 | 17.8 | 47 | 3600 |
| RJIT-O-type 3 × 120 | 14.1 | 19.1 | 50 | 4400 |
| RJIT-O-type 3 × 150 | 16.0 | 21.0 | 54 | 5300 |
| RJIT-O-type 3 × 185 | 17.6 | 22.6 | 58 | 6300 |
TEBAOFLEX® — Marine power and fiber cable electrical data — current values are for air
| Design / configuration (mm²) | Conductor resistance (Ω/km) | Capacitance (µF/km) | Nominal current in air (A) |
|---|---|---|---|
| RJIT-O-type 3 × 50 | 0.393 | 0.62 | 192 |
| RJIT-O-type 3 × 95 | 0.210 | 0.81 | 298 |
| RJIT-O-type 3 × 120 | 0.164 | 0.88 | 346 |
| RJIT-O-type 3 × 150 | 0.132 | 0.98 | 399 |
| RJIT-O-type 3 × 185 | 0.108 | 1.07 | 437 |
TEBAOFLEX® — Three-power-core and 12-fiber marine cable construction
| Element | Specified build | Selection relevance |
|---|---|---|
| Power conductors | Three round Class 5 annealed tinned-copper conductors | Select lugs and preparation methods for the actual conductor class and size. |
| Core insulation / identification | Thermoplastic polyester elastomer (TPEE); brown, black and gray | Each power conductor has its own insulation. The three colors do not identify an integrated PE core. |
| Internal fill | Aramid yarn | Keep filler and optical-unit placement consistent when specifying the complete assembly. |
| Optical unit | One nanocable containing 12 optical fibers | Define the fiber specification and termination interfaces independently of the power-core size. |
| Outer sheath | Yellow polyurethane (PUR) | Coordinate the finished outside diameter with entries, strain relief and the route. |
| Metallic protection / PE | No overall metallic screen or armor; no green/yellow power core | Specify any EMC screen, armor or protective conductor as a separate design requirement. |
Nominal dimensions and cable mass
On narrow screens, scroll the data tables horizontally to see all columns.
Electrical reference values
The current values above are air references. Size a continuously submerged, grouped or partly buried route from its actual thermal conditions, load and fault requirements. Air values are not a universal underwater ampacity. Confirm nominal dimensions against the finished ordered construction before choosing entries and supports.
Check bend clearance for a selected size
Minimum bend radius = 8 × finished cable OD. Select a configuration below to see a calculation using its nominal diameter; the installation check uses the actual finished diameter. Specify cyclic bend geometry separately in the movement schedule.
Nominal OD 40 mm × 8 = 320 mm minimum bend radius . The corresponding bend diameter is 640 mm. Nominal dry cable mass is 2.3 kg/m.
Nominal OD 47 mm × 8 = 376 mm minimum bend radius . The corresponding bend diameter is 752 mm. Nominal dry cable mass is 3.6 kg/m.
Nominal OD 50 mm × 8 = 400 mm minimum bend radius . The corresponding bend diameter is 800 mm. Nominal dry cable mass is 4.4 kg/m.
Nominal OD 54 mm × 8 = 432 mm minimum bend radius . The corresponding bend diameter is 864 mm. Nominal dry cable mass is 5.3 kg/m.
Nominal OD 58 mm × 8 = 464 mm minimum bend radius . The corresponding bend diameter is 928 mm. Nominal dry cable mass is 6.3 kg/m.
For example, 20 m of the 3 × 50 mm² cable has a nominal dry cable mass of 46 kg before attachments. This length calculation does not include buoyancy, vessel movement or hydrodynamic loading; assess support and end loads for the complete route.
Selection guide: The listed dimensions and electrical values apply to the Class 5 construction. Review gland range, terminal space and installation handling against the finished cable diameter. Explore the marine and offshore cable range for routes with different mechanical protection or service arrangements.
Ordering & Quotation Checklist: Send the conductor size, route length and quantity. Include the power circuit and PE/bonding arrangement, water conditions, motion and load schedule, support layout, optical specification and termination interfaces.