JIS C 3410 3.6/6 kV & 6/10 kV SPYCB / TPYCY MV Marine Power Cable

JIS C 3410 (2010) 3.6/6 kV and 6/10 kV SPYCB, SPYCBY, FA-SPYCB, FA-SPYCBY (single-core with non-magnetic copper-alloy wire braid armor CB) and TPYC, TPYCY, FA-TPYC, FA-TPYCY (three-core with galvanized steel wire braid C or copper-alloy wire braid CB) are medium-voltage marine propulsion and main distribution cables engineered to JIS C 3410 and IEC 60092-354.

  • Model designations(FA-)SPYCB, (FA-)SPYCBY (1-Core) & (FA-)TPYC, (FA-)TPYCY (3-Core)
  • StandardsJIS C 3410 (2010), IEC 60092-350 / 354, IEC 60332-1 & IEC 60332-3 Cat A (FA-)
  • Rated voltage U0/U3.6/6 kV & 6/10 kV medium-voltage marine propulsion & distribution
  • Conductor (S / T)Stranded tinned annealed copper wires per JIS C 3410 (10 to 300 mm²)
  • Insulation & Screen (P)90 °C EPR / HEPR rubber + semi-conducting layers + ~0.1 mm copper tape screen
  • Inner Sheath & ArmorPVC inner sheath (Y) + ≥90% coverage copper-alloy (CB) or steel (C) wire braid
  • Outer covering (-Y)Red paint over exposed braid, or extruded red PVC protective oversheath (-Y)
  • Thermal & cold option+90 °C max conductor temp; optional Cold Type (C) passing CSA 22.2 (-40 °C / -35 °C)
Category:

JIS C 3410 3.6/6 kV & 6/10 kV SPYCB Shipboard & Offshore Identification

  • Type: Oil & Gas Cable
  • Model designations: FA-)SPYCB, (FA-)SPYCBY (1-Core) & (FA-)TPYC, (FA-)TPYCY (3-Core
  • Standards: JIS C 3410 (2010), IEC 60092-350 / 354, IEC 60332-1 & IEC 60332-3 Cat A (FA-
  • Rated voltage U0/U: 3.6/6 kV & 6/10 kV medium-voltage marine propulsion & distribution

Marine Electrical, Temperature & Bend Ratings

  • Conductor (S / T): Stranded tinned annealed copper wires per JIS C 3410 (10 to 300 mm²
  • Insulation & Screen (P): 90 °C EPR / HEPR rubber + semi-conducting layers + ~0.1 mm copper tape screen
  • Inner Sheath & Armor: PVC inner sheath (Y) + ≥90% coverage copper-alloy (CB) or steel (C) wire braid
  • Outer covering (-Y): Red paint over exposed braid, or extruded red PVC protective oversheath (-Y
  • Thermal & cold option: +90 °C max conductor temp; optional Cold Type (C) passing CSA 22.2 (-40 °C / -35 °C

JIS C 3410 3.6/6 kV & 6/10 kV SPYCB Halogen-Free / Armored Architecture

JIS C 3410 3.6/6 kV and 6/10 kV cables pair tinned copper conductors with semi-con screened 90 °C EPR/HEPR insulation, 0.1 mm copper tape phase screens, a PVC inner sheath, and ≥90% wire braid armor.

  • Conductor (S / T): Stranded tinned annealed copper wires per JIS C 3410 (S = Single-core, T = Three-core).
  • Conductor Screen & Insulation (P): Semi-conducting tape/compound layer + 90 °C EPR/HEPR rubber insulation per JIS C 3410.
  • Insulation Screen: Non-metallic semi-conducting layer + metallic copper tape screen (~0.1 mm thickness) with Red, Yellow, Blue core ID on 3C.
  • Inner Sheath (Y) & Armor (C / CB): Extruded PVC inner sheath (Y) + ≥90% coverage galvanized steel wire braid (C, painted red) or copper-alloy wire braid (CB on 1C).
  • Outer Protective Covering (-Y): Extruded red flame-retardant PVC outer sheath on SPYCBY, FA-SPYCBY, TPYCY, and FA-TPYCY.

Shipboard Fire Integrity & EMC Performance

  • Copper-tape screened 90 °C EPR/HEPR: Each phase conductor is triple-protected by a semi-conducting conductor screen, 90 °C EPR/HEPR dielectric ('P'), a semi-conducting insulation screen, and an ~0.1 mm metallic copper tape shield.
  • Non-magnetic CB braid on 1-core: Single-core SPYCB / SPYCBY uses a ≥90% coverage copper-alloy wire braid ('CB') to eliminate single-core AC magnetic eddy-current losses.
  • FA- IEC 60332-3 Cat A & Red -Y sheath: Prefix 'FA-' meets IEC 60332-3 Category A bunched fire testing; suffix '-Y' (SPYCBY / TPYCY) adds a red flame-retardant PVC oversheath over the armor.
  • Optional -40 °C Cold Type (C): Available with suffix '(C)' passing CSA C22.2 No. 0.3 cold bend (-40 °C) and cold impact (-35 °C) for ice-class and Arctic LNG vessels.

Salt Fog, Mud, Oil & Low-Smoke Resistance

  • 0.1 mm metallic copper tape screen: Confines the radial electric field and provides a dedicated fault-current path on every 3.6/6 kV and 6/10 kV core.
  • ≥90% wire braid armor coverage: High-density galvanized steel (C) or copper-alloy (CB) wire braid shields the cable against shipboard vibration and mechanical impact.
  • Red HV visual identification: Exposed steel braid on TPYC is uniformly coated with red paint, and oversheathed SPYCBY / TPYCY cables use a bright red PVC outer jacket to identify MV/HV shipboard circuits.
  • Tinned copper marine corrosion defense: All phase conductors are stranded from tinned annealed copper wires per JIS C 3410 to prevent salt-fog and bilge oxidation.

IEC 60092 / NEK 606 / BS Marine Standards

  • JIS C 3410: 2010) & IEC 60092-350 / 354 (3.6/6 kV & 6/10 kV shipboard HV/MV power cables
  • IEC 60332-1-2 vertical flame retardance & IEC 60332-3 Category A bunched flame test: FA- prefix
  • CSA C22.2 No. 0.3: -40 °C cold bend / -35 °C cold impact on Cold Type '(C)'
  • JIS C 3410 EPR/HEPR 90 °C insulation, 0.1 mm copper tape screen & ≥90% wire braid armor

Marine & Offshore Cable Engineering Guides

Factory Sample & Cut-Section Verification

TEBAOFLEX Production Sample

Authentic TEBAOFLEX workshop cut-end and stripped sample photographs of JIS C 3410 SPYCB 3.6/6 kV–6/10 kV single-core gray-sheathed wire-braid armored MV marine power cable, documenting actual conductor stranding, radial wall concentricity, and outer jacket extrusion prior to reel dispatch.

JIS C 3410 SPYCB 3.6/6 kV–6/10 kV single-core gray-sheathed wire-braid armored MV marine power cable — TEBAOFLEX factory stripped sample oblique profile
Oblique Sample ProfileWorkshop view of outer jacket surface finish, cable geometry, and cut-end profile.
JIS C 3410 SPYCB 3.6/6 kV–6/10 kV single-core gray-sheathed wire-braid armored MV marine power cable — TEBAOFLEX conductor and sheath cut-end detail
Sheath & Layer Cut-End DetailClose-up check of outer jacket wall, protective braid or screen layer, and core insulation build.
JIS C 3410 SPYCB 3.6/6 kV–6/10 kV single-core gray-sheathed wire-braid armored MV marine power cable — TEBAOFLEX QC bench cross-section inspection view
QC Cross-Section InspectionEnd-on verification of conductor stranding density and radial wall concentricity.
Marine vessel medium-voltage propulsion switchboard and deck trunking wired with JIS C 3410 3.6/6 kV and 6/10 kV SPYCB and TPYCY cables
JIS C 3410 3.6/6 kV and 6/10 kV (FA-)SPYCB/SPYCBY and (FA-)TPYC/TPYCY cables feature copper-tape screened 90 °C EPR/HEPR cores and ≥90% wire braid armor for shipboard MV power. Photo: Wikimedia Commons contributor, CC BY-SA 2.0, via Wikimedia Commons.

JIS C 3410 3.6/6 kV & 6/10 kV SPYCB Vessel, Platform & FPSO Routing

In Japanese, Korean, and Asian commercial shipbuilding—including large LNG carriers, VLCCs, ultra-large container ships, and heavy crane vessels—JIS C 3410 (2010) High/Medium-Voltage Power Cables (3.6/6 kV and 6/10 kV) are specified for 3.3 kV, 6.6 kV, and 11 kV main generator switchboards, bow thruster motors, and cargo compressor drives. While our0.6/1 kV JIS C 3410 DPYC, TPYC, MPYC & TTYC shipboard cable pagecovers low-voltage power and 150/250 V instrumentation, this dedicated specification covers the screened medium-voltage JIS C 3410 series: single-core SPYCB / SPYCBY / FA-SPYCB / FA-SPYCBY (1×10 mm² to 1×300 mm²) and three-core TPYC / TPYCY / FA-TPYC / FA-TPYCY (3×10 mm² to 3×150 mm²).

Why do single-core JIS C 3410 medium-voltage cables use SPYCB (CB = Copper-Alloy Wire Braid) instead of SPYC (C = Galvanized Steel Wire Braid)? On single-core AC medium-voltage feeders, a magnetic steel wire armor would generate severe eddy-current and hysteresis heating; therefore, JIS C 3410 mandates a non-magnetic copper-alloy wire braid (CB, ≥90% coverage) on single-core SPYCB and SPYCBY, while three-core balanced cables (TPYC / TPYCY) use galvanized steel wire braid (C, painted red) or optional CB braid, with FA- denoting IEC 60332-3 Category A bunched flame retardance. Compare also with our European offshoreNEK 606 3.6/6–12/20 kV RFOU MV cablesandRFCU 3.6/6–18/30 kV GSWB-armored offshore HEPR cables.

Shipboard Systems & Offshore Zone Coverage

  • Single-core 3.6/6 kV & 6/10 kV (FA-)SPYCB and (FA-)SPYCBY (1×10 mm² to 1×300 mm²) are installed in trefoil cleats for high-current main propulsion generators, shaft alternators, shore-to-ship HVSC (AMP) connection buses, and high-capacity propulsion transformers.
  • Three-core 3.6/6 kV & 6/10 kV (FA-)TPYC and (FA-)TPYCY (3×10 mm² to 3×150 mm²) (with Red, Yellow, and Blue phase identification) feed medium-voltage bow/stern thrusters, ballast water treatment pumps, and deck cargo machinery.

JIS C 3410 3.6/6 kV & 6/10 kV SPYCB Marine & Offshore Technical FAQ

How do I decode JIS C 3410 medium-voltage designations like FA-SPYCBY and FA-TPYCY?

'FA-' denotes Flame-Arresting (passing IEC 60332-3 Category A bunched flame test). 'S' is 1-core and 'T' is 3-core. 'P' is 90 °C EPR/HEPR insulation (with semi-conducting screens and 0.1 mm copper tape shield on 3.6/6 kV and 6/10 kV grades). The first 'Y' is the PVC inner sheath; 'C' is galvanized steel wire braid armor ('CB' is non-magnetic copper-alloy wire braid armor on single-core cables); and the final 'Y' is the red PVC outer protective sheath.

Why do single-core 3.6/6 kV and 6/10 kV JIS C 3410 cables use 'CB' (SPYCB) armor?

Single-core AC cables carrying high current induce circulating eddy currents if surrounded by magnetic steel wire armor. Therefore, JIS C 3410 specifies a non-magnetic copper-alloy wire braid ('CB') on all single-core SPYCB and SPYCBY medium-voltage cables.

What is the difference between TPYCY 0.6/1 kV and TPYCY 3.6/6 kV or 6/10 kV?

Unlike 0.6/1 kV low-voltage TPYCY, the 3.6/6 kV and 6/10 kV medium-voltage TPYCY incorporates a semi-conducting conductor screen, thicker radial EPR/HEPR insulation, a semi-conducting insulation screen, and a 0.1 mm metallic copper tape screen around each individual phase core, finished with a red outer sheath.

Is an Arctic / Cold Type version available for ice-class LNG vessels?

Yes. Adding the '(C)' Cold Type suffix supplies the cable with cold-resistant compounds tested to CSA C22.2 No. 0.3 for -40 °C cold bend and -35 °C cold impact.

Full JIS C 3410 (2010) dimensional, strand configuration, overall diameter tolerance, conductor resistance, and weight tables for 3.6/6 kV and 6/10 kV (FA-)SPYCB, (FA-)SPYCBY, (FA-)TPYC, and (FA-)TPYCY shipboard medium-voltage cables.

TEBAOFLEX® — JIS C 3410 3.6/6 kV & 6/10 kV SPYCB / TPYCY MV Marine Power Cable

JIS C 3410 (2010) 3.6/6 kV Single-Core (FA-)SPYCB / SPYCBY & 3-Core (FA-)TPYC / TPYCY Marine MV Cable Specifications
Cores × Area (mm²) Strand Config (No./mm) Conductor Ø (mm) (FA-)SPYCB / TPYC Nom. OD ± Tol (mm) (FA-)SPYCBY / TPYCY Nom. OD ± Tol (mm) Max. DC Resistance at 20 °C (Ω/km) Weight SPYCB / TPYC (kg/km) Weight SPYCBY / TPYCY (kg/km)
1 × 10 (SPYCB/Y) 7 / 1.35 4.05 17.6 ± 0.7 19.8 ± 0.8 1.840 560 640
1 × 16 (SPYCB/Y) 7 / 1.70 5.10 18.8 ± 0.8 21.2 ± 0.8 1.160 660 755
1 × 25 (SPYCB/Y) 7 / 2.14 6.42 20.1 ± 0.8 22.5 ± 0.9 0.734 795 895
1 × 35 (SPYCB/Y) 7 / 2.52 7.56 21.5 ± 0.9 23.9 ± 1.0 0.529 940 1,050
1 × 50 (SPYCB/Y) 19 / 1.78 8.90 22.8 ± 0.9 25.4 ± 1.0 0.391 1,110 1,230
1 × 70 (SPYCB/Y) 19 / 2.14 10.70 24.8 ± 1.0 27.4 ± 1.1 0.270 1,380 1,520
1 × 95 (SPYCB/Y) 19 / 2.52 12.60 26.9 ± 1.1 29.7 ± 1.2 0.195 1,710 1,870
1 × 120 (SPYCB/Y) 37 / 2.03 14.21 28.7 ± 1.1 31.5 ± 1.3 0.154 2,010 2,180
1 × 150 (SPYCB/Y) 37 / 2.25 15.75 30.3 ± 1.2 33.3 ± 1.3 0.126 2,330 2,520
1 × 185 (SPYCB/Y) 37 / 2.52 17.64 32.8 ± 1.3 35.8 ± 1.4 0.100 2,890 3,090
1 × 240 (SPYCB/Y) 61 / 2.25 20.25 35.9 ± 1.4 39.3 ± 1.6 0.0762 3,590 3,830
1 × 300 (SPYCB/Y) 61 / 2.52 22.68 38.9 ± 1.6 42.5 ± 1.6 0.0607 4,330 4,610
3 × 16 (TPYC/Y) 7 / 1.70 5.10 36.5 ± 1.5 39.9 ± 1.6 1.160 1,920 2,170
3 × 35 (TPYC/Y) 7 / 2.52 7.56 42.2 ± 1.6 46.0 ± 1.7 0.529 2,800 3,120
3 × 70 (TPYC/Y) 19 / 2.14 10.70 49.6 ± 1.8 53.6 ± 1.9 0.270 4,210 4,610
3 × 120 (TPYC/Y) 37 / 2.03 14.21 57.8 ± 2.0 62.2 ± 2.1 0.154 6,210 6,720
3 × 150 (TPYC/Y) 37 / 2.52 15.75 61.6 ± 2.1 66.2 ± 2.2 0.126 7,250 7,820

TEBAOFLEX® — JIS C 3410 3.6/6 kV & 6/10 kV SPYCB / TPYCY MV Marine Power Cable

JIS C 3410 (2010) 6/10 kV Single-Core (FA-)SPYCB / SPYCBY & 3-Core (FA-)TPYC / TPYCY Marine MV Cable Specifications
Cores × Area (mm²) Strand Config (No./mm) Conductor Ø (mm) (FA-)SPYCB / TPYC Nom. OD ± Tol (mm) (FA-)SPYCBY / TPYCY Nom. OD ± Tol (mm) Max. DC Resistance at 20 °C (Ω/km) Weight SPYCB / TPYC (kg/km) Weight SPYCBY / TPYCY (kg/km)
1 × 16 (6/10kV SPYCB/Y) 7 / 1.70 5.10 20.8 ± 0.8 23.2 ± 0.9 1.160 765 870
1 × 25 (6/10kV SPYCB/Y) 7 / 2.14 6.42 22.1 ± 0.9 24.7 ± 1.0 0.734 910 1,030
1 × 35 (6/10kV SPYCB/Y) 7 / 2.52 7.56 23.5 ± 0.9 26.1 ± 1.0 0.529 1,060 1,190
1 × 50 (6/10kV SPYCB/Y) 19 / 1.78 8.90 24.8 ± 1.0 27.4 ± 1.1 0.391 1,230 1,360
1 × 70 (6/10kV SPYCB/Y) 19 / 2.14 10.70 26.8 ± 1.1 29.6 ± 1.2 0.270 1,510 1,670
1 × 95 (6/10kV SPYCB/Y) 19 / 2.52 12.60 28.9 ± 1.2 31.7 ± 1.3 0.195 1,850 2,020
1 × 120 (6/10kV SPYCB/Y) 37 / 2.03 14.21 30.5 ± 1.2 33.5 ± 1.3 0.154 2,150 2,340
1 × 150 (6/10kV SPYCB/Y) 37 / 2.25 15.75 32.8 ± 1.3 35.8 ± 1.4 0.126 2,610 2,820
1 × 185 (6/10kV SPYCB/Y) 37 / 2.52 17.64 34.8 ± 1.4 38.2 ± 1.5 0.100 3,060 3,290
1 × 240 (6/10kV SPYCB/Y) 61 / 2.25 20.25 37.7 ± 1.5 41.1 ± 1.6 0.0762 3,760 4,010
1 × 300 (6/10kV SPYCB/Y) 61 / 2.52 22.68 40.3 ± 1.6 43.9 ± 1.7 0.0607 4,470 4,760
3 × 16 (6/10kV TPYC/Y) 7 / 1.70 5.10 41.0 ± 1.6 44.6 ± 1.7 1.160 2,290 2,590
3 × 35 (6/10kV TPYC/Y) 7 / 2.52 7.56 46.7 ± 1.7 50.7 ± 1.8 0.529 3,220 3,590
3 × 50 (6/10kV TPYC/Y) 19 / 1.78 8.90 49.8 ± 1.8 53.8 ± 1.9 0.391 3,780 4,180
3 × 70 (6/10kV TPYC/Y) 19 / 2.14 10.70 54.1 ± 1.9 58.5 ± 2.0 0.270 4,690 5,170
3 × 95 (6/10kV TPYC/Y) 19 / 2.52 12.60 58.4 ± 2.0 63.0 ± 2.1 0.195 5,740 6,290
3 × 120 (6/10kV TPYC/Y) 37 / 2.03 14.21 62.3 ± 2.1 67.1 ± 2.2 0.154 6,750 7,360
3 × 150 (6/10kV TPYC/Y) 37 / 2.25 15.75 65.9 ± 2.2 70.7 ± 2.3 0.126 7,790 8,440

Selection guide: Specify JIS C 3410 3.6/6 kV or 6/10 kV, designation (SPYCB, SPYCBY, FA-SPYCB, FA-SPYCBY, TPYC, TPYCY, FA-TPYC, or FA-TPYCY), cross-section (10–300 mm²), and optional Cold Type (C).

Ordering & Quotation Checklist: Request a factory quotation for JIS C 3410 (2010) 3.6/6 kV or 6/10 kV (FA-)SPYCB, (FA-)SPYCBY, (FA-)TPYC, or (FA-)TPYCY medium-voltage marine power cables.

JIS C 3410 DPYC, TPYC, MPYC & TTYC / TTYCS Marine Shipboard Cable

JIS C 3410 DPYC, TPYC, MPYC & TTYC / TTYCS Marine Shipboard Cable

JIS C 3410 (Aligned with IEC 60092-353 & IEC 60092-376)

VIEW PRODUCT »

RFCU 3.6/6–18/30 kV GSWB & RFOU 18/30 kV (P20/P22/P113) Offshore Cable

RFCU 3.6/6–18/30 kV GSWB & RFOU 18/30 kV (P20/P22/P113) Offshore Cable

RFCU (3.6/6–18/30 kV GSWB Armor) & RFOU / RFOU M 18/30(36) kV (P20/P22/P113)

VIEW PRODUCT »

00/12/FO2, RMP200 & 6XM524 Pipe Crawler & C-3400 / 26XM520 Cleaning Robot Cable

00/12/FO2, RMP200 & 6XM524 Pipe Crawler & C-3400 / 26XM520 Cleaning Robot Cable

00/12/FO2, 00/20/FOX2 (Electro-Optical), 524/11 (11-Core Copper), RMP200 / RMP300 / RMP350 / RMP500, 6XM524, 1HRS347

VIEW PRODUCT »

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for JIS C 3410 3.6/6 kV & 6/10 kV SPYCB / TPYCY MV Marine Power Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.

  • ISO 9001 Factory Direct
  • MOQ 50 m (Custom Builds)
  • 24h Engineering Reply
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    JIS C 3410 3.6/6 kV & 6/10 kV SPYCB / TPYCY MV Marine Power CableGet A Quote