URC-1 & HYJQF33 Submarine Optical Trunk, 10kVDC Observatory & FERE/FEVE Cable

Engineered for transoceanic and regional island-hopping telecommunication links, 25-year cabled seafloor scientific observatories, and shallow-water platform/archipelago interconnections.

  • Submarine cable standardsITU-T G.976 / IEC 60794-3, URC-1 (LW / LWP / SA / DA), HYJQF33 / HYJQY33, 10 kVDC Observatory, FERE / FEVE / TXRA / HYJQF41
  • Optical fiber capacity4 to 192 fibers ITU-T G.654.E (ultra-low attenuation ≤0.16 dB/km @ 1550 nm) or G.652.D inside hermetic SS/Copper tube
  • Power feeding & voltage10 kV DC (1.0–2.5 A constant-current copper tube for repeaters/observatories); 0.6/1 kV to 35 kV AC (FERE/FEVE/HYJQF41)
  • Pressure vault & armorThree-layer high-tensile steel wire vault around seamless Copper/SS tube + Single (SA), Double (DA), or Rock Armor (RA)
  • Water depth capabilityUp to 8,000 m abyssal ocean floor (URC-1 LW / Observatory); 0 to 1,500 m continental shelf (URC-1 SA/DA, HYJQF33, FERE/FEVE)
  • Nominal tensile strength70–100 kN (Lightweight LW); 180–280 kN (Single-Armored SA / FERE); 380–650 kN (Double-Armored DA / HYJQF33 / Rock Armor)
  • Design service life≥ 25 years continuous submerged operation with zero hydrogen-induced optical attenuation drift
  • Outer serving / sheathHigh-density Polyethylene (HDPE) + bitumen-impregnated polypropylene (PP) yarn roving over galvanized steel armor wires
Category:

URC-1 Shipboard & Offshore Identification

  • Type: Low-Voltage Signal Cable
  • Submarine cable standards: ITU-T G.976 / IEC 60794-3, URC-1 (LW / LWP / SA / DA), HYJQF33 / HYJQY33, 10 kVDC Observatory, FERE / FEVE / TXRA / HYJQF41
  • Optical fiber capacity: 4 to 192 fibers ITU-T G.654.E (ultra-low attenuation ≤0.16 dB/km @ 1550 nm) or G.652.D inside hermetic SS/Copper tube
  • Power feeding & voltage: 10 kV DC (1.0–2.5 A constant-current copper tube for repeaters/observatories); 0.6/1 kV to 35 kV AC (FERE/FEVE/HYJQF41

Marine Electrical, Temperature & Bend Ratings

  • Pressure vault & armor: Three-layer high-tensile steel wire vault around seamless Copper/SS tube + Single (SA), Double (DA), or Rock Armor (RA
  • Water depth capability: Up to 8,000 m abyssal ocean floor (URC-1 LW / Observatory); 0 to 1,500 m continental shelf (URC-1 SA/DA, HYJQF33, FERE/FEVE
  • Nominal tensile strength: 70–100 kN (Lightweight LW); 180–280 kN (Single-Armored SA / FERE); 380–650 kN (Double-Armored DA / HYJQF33 / Rock Armor
  • Design service life: ≥ 25 years continuous submerged operation with zero hydrogen-induced optical attenuation drift
  • Outer serving / sheath: High-density Polyethylene (HDPE) + bitumen-impregnated polypropylene (PP) yarn roving over galvanized steel armor wires

URC-1 Halogen-Free / Armored Architecture

Engineered around a hermetic laser-welded stainless-steel/copper optical core, high-tensile steel pressure vault, HV polyethylene dielectric, and bitumen-flushed galvanized wire armor.

  • Optical Unit: 4 to 192 ITU-T G.654.E or G.652.D fibers in a thixotropic-gel-filled laser-welded 316L stainless steel tube.
  • Pressure Vault & DC Feed: Interlocking high-tensile steel wire vault + seamless swaged oxygen-free copper tube (for 10 kV DC feeding).
  • HV Dielectric & Bedding: Extruded ultra-clean Medium/High-Density Polyethylene (MDPE/HDPE) insulation (or 3C EPR/XLPE in FERE/FEVE/HYJQF41).
  • Submarine Wire Armor: Single (SA) or Double (DA) helical layer of heavy galvanized steel wires flooded with marine bitumen compound.
  • Outer Serving: Cross-wound bitumen-impregnated polypropylene (PP) yarn roving with high-visibility yellow/black tracer stripes or extruded HDPE.

Shipboard Fire Integrity & EMC Performance

  • URC-1 (LW / SA / DA) & HYJQF33 (4–192F): ITU-T G.976 submarine optical trunk cables with G.654.E / G.652.D fibers in hermetic SS/Copper tube + steel wire vault up to 8,000 m depth.
  • 10 kV DC Seafloor Observatory EO Trunk: Seamless copper conductor (0.5–1.2 Ω/km) + high-voltage PE insulation + 12–48 SMF powering deep-ocean scientific nodes and tsunami sensors.
  • FERE / FEVE / TXRA / HYJQF41 Composite: 0.6/1 kV to 35 kV AC 3-core subsea power + 24–144F FIMT optical composite cables for island crossings and coastal platforms.
  • Trawl- & Anchor-Resistant SA / DA / RA Armor: Single-armored (180–280 kN) and double/rock-armored (380–650 kN) galvanized steel wire packages with bitumen + PP roving serving.

Salt Fog, Mud, Oil & Low-Smoke Resistance

  • 80 MPa abyssal hydrostatic pressure vault: Interlocking high-tensile steel vault wires around the laser-welded fiber tube withstand 8,000 m ocean floor pressure without micro-bending loss.
  • Hermetic hydrogen-barrier copper & stainless tube: Prevents molecular hydrogen ingress over a 25-year service life while providing a low-resistance 10 kV DC power-feed path.
  • Full shore-end to deep-sea armor transition: Supplied in continuous factory-jointed lengths transitioning from Double Armor (DA) at shore landings to Single Armor (SA) and Lightweight (LW) offshore.
  • End-to-end subsea power & telemetry engineering: Integrate with ourMCIL/MCBH wet-mate sensor whips & PBOF harnessesand4C ocean-bottom seismic (OBC) cables.

IEC 60092 / NEK 606 / BS Marine Standards

  • ITU-T Recommendation G.976 & G.972: Optical fibre submarine cable systems — mechanical, hydrostatic, and hydrogen-aging test methods
  • IEC 60794-3 & ITU-T G.654.E / G.652.D: Submarine telecommunication optical cables and ultra-low-loss single-mode optical fibers
  • CIGRE TB 490 / IEC 60502-2 & IEC 63026: Submarine AC power and composite optical cables from 0.6/1 kV to 35 kV

Marine & Offshore Cable Engineering Guides

Submarine cable-laying vessel deploying URC-1 and HYJQF33 double-armored submarine optical trunk and 10 kVDC seafloor observatory cables
URC-1 (LW/SA/DA) & HYJQF33 submarine optical trunk cables, 10 kVDC seafloor observatory electro-optical cables, and FERE/FEVE/TXRA composite cables. Photo: Wikimedia Commons contributor, CC BY-SA 2.0.

URC-1 Vessel, Platform & FPSO Routing

Subsea telecommunications, island grid/telecom interconnectors, and permanent cabled ocean observatories require armored trunk cables certified to ITU-T G.976 and IEC 60794-3 for a 25-year submerged design life. For unrepeatered regional links (50–450 km) and repeatered deepwater trunks (up to 8,000 m depth), URC-1 (LW Lightweight, LWP Lightweight Protected, SA Single-Armored, DA Double-Armored) and HYJQF33 / HYJQY33 Submarine Optical Cables (4 to 192 fibers, ITU-T G.654.E or G.652.D) enclose thixotropic-gel-buffered fibers inside a laser-welded stainless steel tube surrounded by a pressure-resistant vault of high-tensile steel wires and a seamless swaged copper composite conductor. In shallow continental-shelf zones (<1,500 m) exposed to bottom-trawl fishing gear and ship anchors, SA and DA variants add one or two layers of heavy 3.0–6.0 mm galvanized steel armor wires bedded in bitumen and polypropylene roving.

For Cabled Seafloor Scientific Observatories (tsunami warning, benthic seismology, and ocean-climate networks), the 10 kV DC Copper-Tube Electro-Optical Trunk Cable uses its seamless copper conductor (0.5–1.2 Ω/km DC resistance) with extruded medium/high-density polyethylene (MDPE/HDPE) insulation to transmit 10 kV DC (10–100 kW constant current or constant voltage) and 12–48 single-mode fibers to deepwater branching units (BU) and seafloor junction boxes. For near-shore crossings, offshore platforms, and coastal islands requiring simultaneous AC power and high-count fiber, FERE (EPR + PE + Wire Armor + PE), FEVE (EPR + PVC + Wire Armor + PVC), TXRA, and HYJQF41 (0.6/1 kV up to 35 kV AC) integrate three power cores with 24–144 optical fibers under heavy submarine wire armor. Compare with ourNEK 400-8-820 & TERE 24 kV floating aquaculture hybrid subsea cablesandAPI 17E subsea production umbilicals & dynamic riser cables.

Shipboard Systems & Offshore Zone Coverage

  • URC-1 (LW/SA/DA), HYJQF33 & 10 kVDC Observatory Trunk Cables connect island telecom landings, offshore oil/gas field fiber backbones, and 4,000–8,000 m cabled seafloor seismic/tsunami observatories.
  • FERE, FEVE, TXRA & HYJQF41 Shallow-Subsea Composite Cables supply simultaneous AC power and optical telemetry across estuaries, rivers, straits, and nearshore wind/monitoring platforms.

URC-1 Marine & Offshore Technical FAQ

What is the difference between URC-1 LW, URC-1 SA, and URC-1 DA submarine optical cables?

All three share the identical central optical core (fibers in a hermetic metal tube + steel wire pressure vault + HDPE insulation). LW (Lightweight) is unarmored for deep abyssal plains (1,500–8,000 m). SA (Single-Armored) adds one layer of heavy galvanized steel wires for continental shelves down to 1,500 m. DA (Double-Armored) adds two armor layers for shore landings and high-risk anchor/trawl zones (<200–500 m).

How does the 10 kV DC seafloor observatory trunk cable power underwater scientific nodes?

A seamless copper tube swaged over the central steel wire vault acts as a 0.5–1.2 Ω/km DC conductor insulated by thick HDPE, delivering up to 10 kV DC (with seawater return via titanium/platinized anodes) to seafloor branching units and medium-voltage DC/DC converters.

Why is ITU-T G.654.E fiber used in long unrepeatered HYJQF33 and URC-1 submarine trunks?

ITU-T G.654.E ultra-low-loss pure-silica-core fiber achieves attenuation ≤0.155–0.165 dB/km at 1550 nm with a large effective area (110–130 µm²), extending unrepeatered island-to-shore spans to 350–450+ km without submerged optical amplifiers.

When should we specify FERE, FEVE, TXRA, or HYJQF41 instead of URC-1?

Specify FERE, FEVE, TXRA, or HYJQF41 when the subsea crossing must deliver 3-phase 50/60 Hz AC utility power (0.6/1 kV up to 35 kV) alongside 24–144 optical fibers to an offshore platform, lighthouse, aquaculture barge, or nearshore island.

Submarine cable code (URC-1 LW/SA/DA, HYJQF33, 10 kVDC Observatory, FERE/FEVE/TXRA), fiber count (4–192F G.654.E/G.652.D), copper power feeding / HV voltage rating, armor class, ocean depth rating, and tensile strength.

TEBAOFLEX® — URC-1 & HYJQF33 Submarine Optical Trunk, 10kVDC Observatory & FERE/FEVE Cable

URC-1, HYJQF33 Submarine Optical Trunk, 10 kVDC Observatory & FERE/FEVE Composite Cable Specifications
Cable Type & Code Fiber Count & Grade Power Conductor / Voltage Armor Construction Nominal OD (mm) Max Depth (m) Nominal Break Load
URC-1 LW (Lightweight) 4–96F G.654.E / G.652.D Swaged Cu Tube (1.0 Ω/km, 10 kVDC) Steel Wire Vault + HDPE Sheath 17.0–21.0 8,000 m 85–110 kN
URC-1 LWP (Protected) 4–96F G.654.E / G.652.D Swaged Cu Tube (10 kVDC) Steel Vault + Steel Tape + HDPE 21.5–24.5 6,000 m 105–130 kN
URC-1 SA / HYJQY33 12–144F G.654.E / G.652.D Cu Tube (0.7–1.0 Ω/km) or Dielectric Single Layer 4.0–5.0mm GSW + PP Yarn 28.0–36.0 1,500 m 220–310 kN
URC-1 DA / HYJQF33 12–192F G.654.E / G.652.D Cu Tube (0.7–1.0 Ω/km) or Dielectric Double Layer GSW + Bitumen + PP Yarn 38.0–48.0 500 m 420–620 kN
10 kVDC Observatory Trunk 12–48F G.652.D / G.654.E Seamless Cu Tube (0.6 Ω/km, 10 kVDC) Steel Vault + SA/DA GSW + HDPE 26.0–42.0 6,000 m 120–480 kN
FERE / FEVELV Subsea 12–48F in SS FIMT 3×16–120 mm² Cu (0.6/1 kV AC) EPR Insul + Galv. Wire Armor + PE/PVC 32.0–62.0 300 m 150–350 kN
TXRA / HYJQF41 MV Subsea 24–96F in Dual SS FIMT 3×50–300 mm² Cu (6/10–26/35 kV AC) XLPE/EPR + Lead/PE + GSW Armor + PP 68.0–125.0 300 m 280–650 kN

Selection guide: Specify URC-1 LW for deep-ocean basins (1,500–8,000 m), URC-1 SA/DA or HYJQF33 for trawled continental shelves (<1,500 m), 10 kVDC Copper-Tube Trunk for seafloor scientific observatories, or FERE/FEVE/TXRA/HYJQF41 for shallow AC power + fiber crossings.

Ordering & Quotation Checklist: Request a technical quotation for URC-1 (LW/SA/DA) & HYJQF33 submarine optical trunk cables, 10 kVDC seafloor observatory cables, or FERE/FEVE/TXRA/HYJQF41 subsea power-optical composite cables.

NEK 400-8-820 & TERE 24kV Aquaculture Hybrid & CB 1900/7000 Trawl Sonar Cable

NEK 400-8-820 & TERE 24kV Aquaculture Hybrid & CB 1900/7000 Trawl Sonar Cable

Norwegian NEK 400-8-820 / NS 9415, TERE 24 kV Subsea Feeder, CB 1900 / CB 6000 / CB 7000 Netsonde, Type 4622CC–6013CC

VIEW PRODUCT »

API 17E Subsea Production Umbilical, API 17G IWOCS, EFL/EOFL & MV Pump Jumper

API 17E Subsea Production Umbilical, API 17G IWOCS, EFL/EOFL & MV Pump Jumper

API Spec 17E / ISO 13628-5, API RP 17G / ISO 13628-7 (IWOCS), API Spec 16D (BOP MUX), API 17F, and CIGRE TB 722 / IEC 63026

VIEW PRODUCT »

MCIL/MCBH & LPIL Wet-Mate Whip, DBH13C AUV Docking & 10,000 PSI PBOF Cable

MCIL/MCBH & LPIL Wet-Mate Whip, DBH13C AUV Docking & 10,000 PSI PBOF Cable

Micro Circular (MCIL/MCBH), Standard Circular (IL/BH), Low-Profile (LPIL/LPBH), DBH13C AUV Docking, 10,000 PSI PBOF

VIEW PRODUCT »

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for URC-1 & HYJQF33 Submarine Optical Trunk, 10kVDC Observatory & FERE/FEVE Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.

  • ISO 9001 Factory Direct
  • MOQ 50 m (Custom Builds)
  • 24h Engineering Reply
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    URC-1 & HYJQF33 Submarine Optical Trunk, 10kVDC Observatory & FERE/FEVE CableGet A Quote