300 V EPDM/SBR Flexible Equipment Cable, AWM 4097

Indoor light-duty equipment, selected appliance connections and vacuum-cleaner-type equipment routes with the required cord designation and circuit schedule. Rated voltage: 300 V UL temperature: 60°C Operating range: −40 to +60°C Nominal OD: 6.73 mm Minimum stationary / installation radius: 69 mm / 69 mm

  • Rated voltage300 V
  • UL temperature60°C
  • Operating range−40 to +60°C
  • Nominal OD6.73 mm
  • Minimum stationary / installation radius69 mm / 69 mm
  • Dielectric test1500 V AC for 1 minute
  • Maximum pulling tension82 lbf
  • Equipment-wiring designationAWM 4097

300 V EPDM/SBR Flexible Equipment Cable High-Temperature Wire Identification

  • Type: Industrial Cables
  • Rated voltage: 300 V
  • UL temperature: 60°C
  • Operating range: −40 to +60°C

Continuous Thermal, Dielectric & AWG Ratings

  • Nominal OD: 6.73 mm
  • Minimum stationary / installation radius: 69 mm / 69 mm
  • Dielectric test: 1500 V AC for 1 minute
  • Maximum pulling tension: 82 lbf
  • Equipment-wiring designation: AWM 4097

300 V EPDM/SBR Flexible Equipment Cable Plated Conductor & Fluoropolymer/Silicone Build

  • Conductors: 4 × 18 AWG, 41 × 34 tinned copper.
  • Insulation: EPDM; black, white, brown and red.
  • Separator: Paper tape.
  • Outer jacket: Black SBR rubber.
  • Representative core schedule: Four circuit cores; no green/yellow protective core in this build.

Select the complete construction

No foil, braid or armor is included. Where protective earthing is required, order a core identification and construction appropriate to the equipment rather than assigning an unmarked colored core without review.

Define the ordered acceptance conditions

Include the exact construction, applicable designations, dimensions and required inspections in the purchase specification. For motion, define the carrier or route geometry, temperature, speed, acceleration and cycle definition. For optical or RF links, include wavelengths or frequencies, interfaces, connections and the installed link acceptance criteria.

Thermal Endurance, Outgassing & Dielectric Stability

  • Select the complete construction: No foil, braid or armor is included.
  • Define the ordered acceptance conditions: Include the exact construction, applicable designations, dimensions and required inspections in the purchase specification.
  • Route and equipment selection: Outdoor, wet, oil-resistant, SJOW and H07RN-F constructions require their own specifications.
  • Select load and length together: Provide the equipment current, duty cycle, supply voltage and complete outgoing/return circuit length.

Chemical, Solvent, Flame & Cryogenic Resistance

  • Installation & Routing: Indoor light-duty equipment, selected appliance connections and vacuum-cleaner-type equipment routes with the required cord designation and circuit schedule.
  • Termination & Entry Check: Use each value for the stated construction and operating condition. Nominal dimensions refer to the representative configuration; select the full size and installation schedule before ordering.
  • UL AWM 4097: Selected 300 V equipment-wiring construction.
  • UL / CSA equipment wiring: Ordered classification and temperature scope.

UL 758 AWM / CSA / Aerospace & Furnace Standards

  • UL AWM 4097: Selected 300 V equipment-wiring construction.
  • UL / CSA equipment wiring: Ordered classification and temperature scope.
  • RoHS / REACH: Selected environmental compliance references.

High-Temperature & Fluoropolymer Wire Guides

Indoor light-duty equipment cord route beside a workshop appliance
Indoor equipment-cord use beside a workshop appliance. Select the actual core schedule and cord designation for the equipment.

300 V EPDM/SBR Flexible Equipment Cable Thermal Zone & Internal Equipment Wiring

300 V light-duty rubber equipment cord supplies selected indoor appliances and equipment using four finely stranded 18 AWG tinned-copper cores. The representative construction uses EPDM insulation in black, white, brown and red, a paper separator and a black SBR rubber outer jacket, with a nominal diameter of 6.73 mm.

An equipment cord needs the correct core schedule, temperature, voltage and installation designation. Rubber insulation alone does not identify outdoor, oil-resistant, wet-location or heavy-duty service. Choose the ordered cord and terminations from the complete equipment application rather than inferring those properties from a black rubber jacket.

Furnaces, Ovens, Avionics & Cleanroom Assemblies

  • Indoor light-duty equipment, selected appliance connections and vacuum-cleaner-type equipment routes with the required cord designation and circuit schedule.

Route and equipment selection

Outdoor, wet, oil-resistant, SJOW and H07RN-F constructions require their own specifications. Identify the actual environment and cord designation before substituting this light-duty indoor build.

Compare related cable duties

  • SOW & SJOW Portable Rubber Cord: UL 62 600V & 300V EPDM Flexible Power Cable
  • SJEOOW 300V Portable Power Cord: UL 62 -50°C to +105°C TPE Flexible Cord
  • H07RN-F 450/750 V Flexible Rubber Power Cable

300 V EPDM/SBR Flexible Equipment Cable Thermal Rating & Stripping FAQ

How should engineers address 'select the complete construction' for 300 V EPDM/SBR Flexible Equipment Cable, AWM 4097?

No foil, braid or armor is included. Where protective earthing is required, order a core identification and construction appropriate to the equipment rather than assigning an unmarked colored core without review.

What is the engineering rule regarding 'define the ordered acceptance conditions' on 300 V EPDM/SBR Flexible Equipment Cable, AWM 4097?

Include the exact construction, applicable designations, dimensions and required inspections in the purchase specification. For motion, define the carrier or route geometry, temperature, speed, acceleration and cycle definition. For optical or RF links, include wavelengths or frequencies, interfaces, connections and the installed link acceptance criteria.

How does 300 V EPDM/SBR Flexible Equipment Cable, AWM 4097 handle route and equipment selection in field installations?

Outdoor, wet, oil-resistant, SJOW and H07RN-F constructions require their own specifications. Identify the actual environment and cord designation before substituting this light-duty indoor build.

What layer-by-layer materials and screening options define 300 V EPDM/SBR Flexible Equipment Cable, AWM 4097?

Conductors: 4 × 18 AWG, 41 × 34 tinned copper.; Insulation: EPDM; black, white, brown and red.; Separator: Paper tape.; Outer jacket: Black SBR rubber.; Representative core schedule: Four circuit cores; no green/yellow protective core in this build.

Use each value for the stated construction and operating condition. Nominal dimensions refer to the representative configuration; select the full size and installation schedule before ordering.

TEBAOFLEX® — 300 V EPDM/SBR Flexible Equipment Cable, AWM 4097 Construction, Operating & Compliance Matrix

300 V EPDM/SBR Flexible Equipment Cable, AWM 4097 4-Column Engineering Schedule
Cable Element / Layer Selected Construction Operating Parameter / Condition Normative Reference & Test Scope
Conductors 4 × 18 AWG, 41 × 34 tinned copper. Rated voltage: 300 V UL AWM 4097 — Selected 300 V equipment-wiring construction.
Insulation EPDM; black, white, brown and red. UL temperature: 60°C UL / CSA equipment wiring — Ordered classification and temperature scope.
Separator Paper tape. Operating range: −40 to +60°C RoHS / REACH — Selected environmental compliance references.
Outer jacket Black SBR rubber. Nominal OD: 6.73 mm UL AWM 4097 — Selected 300 V equipment-wiring construction.
Representative core schedule Four circuit cores; no green/yellow protective core in this build. Minimum stationary / installation radius: 69 mm / 69 mm UL / CSA equipment wiring — Ordered classification and temperature scope.

TEBAOFLEX® — 300 V EPDM/SBR Flexible Equipment Cable, AWM 4097 technical parameters

300 V EPDM/SBR Flexible Equipment Cable, AWM 4097 technical parameters
Parameter Value / condition
Rated voltage 300 V
UL temperature 60°C
Operating range −40 to +60°C
Nominal OD 6.73 mm
Minimum stationary / installation radius 69 mm / 69 mm
Dielectric test 1500 V AC for 1 minute
Maximum pulling tension 82 lbf
Equipment-wiring designation AWM 4097

TEBAOFLEX® — 300 V EPDM/SBR Flexible Equipment Cable, AWM 4097 configuration comparison

300 V EPDM/SBR Flexible Equipment Cable, AWM 4097 configuration comparison
Configuration Selection scope
Four-core representative 18 AWG EPDM/SBR indoor equipment cord.
Protective-conductor version Specify core identification and exact ordered construction.
Outdoor rubber cord Separate environmental and installation designation.
Heavy-duty equipment supply Separate conductor, jacket and mechanical-duty design.

TEBAOFLEX® — Equipment-cord classifications

Equipment-cord classifications
Designation Material / application boundary
AWM 4097 Selected EPDM/SBR indoor equipment-wiring construction.
SJOW / SJOOW Separate junior-service rubber-cord designation and ordered environmental scope.
SJEOOW Separate thermoplastic-elastomer cord construction and markings.
H07RN-F Separate harmonized rubber power cable; select its complete insulation/sheath and duty.

Select load and length together

Provide the equipment current, duty cycle, supply voltage and complete outgoing/return circuit length. Add ambient conditions and terminal ratings. These inputs support a specific voltage-drop and thermal review; a short-cord current value should not be extended to every length or bundled installation.

Selection guide: Send the circuit schedule, route drawing, connection details and required quantity with your inquiry. Our engineers can coordinate the selected cable construction, finished dimensions, installation conditions and delivery lengths with your equipment specification. Include required reel lengths, installation markings and inspection documents so the delivery schedule matches the project.

Ordering & Quotation Checklist: Send equipment type, voltage, current, length, core assignments, earthing, environment, movement and termination.

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for 300 V EPDM/SBR Flexible Equipment Cable, AWM 4097? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.

  • ISO 9001 Factory Direct
  • MOQ 50 m (Custom Builds)
  • 24h Engineering Reply
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    You may also like…

    300 V EPDM/SBR Flexible Equipment Cable, AWM 4097Get A Quote