EN 50264-3-2 Screened Rolling Stock Power Cable

Railway equipment, power distribution and rolling-stock interconnections with specified fixed or moderately flexible routes and fire-performance requirements. Rated voltage: 600/1000 V Conductor set: 2 × 35 mm², Class 5 tinned copper Operating range: −40 to +120°C Nominal OD / mass: 23.5 mm / 939 kg/km Braid coverage: 80%

  • Rated voltage600/1000 V
  • Conductor set2 × 35 mm², Class 5 tinned copper
  • Operating range−40 to +120°C
  • Nominal OD / mass23.5 mm / 939 kg/km
  • Braid coverage80%
  • Dielectric test3.5 kV AC for 5 minutes
  • Material fire/toxicity scopeR15/R16 HL3 references for insulation/jacket materials.
  • Two-core screened powerRepresentative configuration.

EN 50264-3-2 Screened Rolling Stock Power Core Identification & Ratings

  • Type: Industrial Cables
  • Rated voltage: 600/1000 V
  • Conductor set: 2 × 35 mm², Class 5 tinned copper
  • Operating range: −40 to +120°C

Electrical, Thermal & Mechanical Bend Limits

  • Nominal OD / mass: 23.5 mm / 939 kg/km
  • Braid coverage: 80%
  • Dielectric test: 3.5 kV AC for 5 minutes
  • Material fire/toxicity scope: R15/R16 HL3 references for insulation/jacket materials.
  • Two-core screened power: Representative configuration.

EN 50264-3-2 Screened Rolling Stock Power Conductor, Insulation & Sheath Build

  • Conductors: 2 × 35 mm² Class 5 tinned copper.
  • Insulation: Black XLPO with core identification.
  • Screen: Tinned-copper braid; nominal 80% coverage.
  • Outer jacket: Black XLPO.
  • Representative dimensions: 23.5 mm nominal finished diameter.

Select the complete construction

The representative has two insulated conductors and one overall braid. It is not a three-phase VFD layout and does not include a green/yellow protective core unless a different core schedule is ordered.

Define the ordered acceptance conditions

Include the exact construction, applicable designations, dimensions and required inspections in the purchase specification. For motion, define the carrier or route geometry, temperature, speed, acceleration and cycle definition. For optical or RF links, include wavelengths or frequencies, interfaces, connections and the installed link acceptance criteria.

Primary Electrical & Mechanical Performance

  • Select the complete construction: The representative has two insulated conductors and one overall braid.
  • Define the ordered acceptance conditions: Include the exact construction, applicable designations, dimensions and required inspections in the purchase specification.
  • Route and equipment selection: Specify the whole installation context, including enclosures, routing and fire assessment.
  • State the fire-evidence scope in the cable schedule: Write the required standard, requirement set, material or cable scope and applicable hazard level as separate fields.

Industrial Oil, Flame & Environmental Protection

  • Installation & Routing: Railway equipment, power distribution and rolling-stock interconnections with specified fixed or moderately flexible routes and fire-performance requirements.
  • Termination & Entry Check: Use each value for the stated construction and operating condition. Nominal dimensions refer to the representative configuration; select the full size and installation schedule before ordering.
  • IEC 60228: Conductor class reference.
  • EN 50264-3-2: Railway reduced-dimension multicore cable reference.

IEC / EN / VDE / UL Reference Standards

  • IEC 60228: Conductor class reference.
  • EN 50264-3-2: Railway reduced-dimension multicore cable reference.
  • EN 45545-2: Railway material fire-requirement reference.
  • IEC 60332-1-2 / IEC 60332-3-24: Flame-test references.
  • EN 50266-2-4: Bunched-cable flame-test reference.

Industrial Cable Selection & Routing Guides

Supported power cable route and closed equipment enclosures beneath railway rolling stock
Supported power routing and closed equipment enclosures on railway rolling stock.

EN 50264-3-2 Screened Rolling Stock Power Industrial Installation & Routing Guide

600/1000 V screened XLPO railway power cable connects selected fixed and moderately flexible rail equipment routes using two 35 mm² Class 5 tinned-copper conductors. Black cross-linked polyolefin insulation, a tinned-copper braid and an XLPO outer jacket form the representative low-smoke, halogen-free material construction.

Railway fire requirements, temperature, mechanical routing and circuit protection should be specified together. The material-level fire and toxicity scope must stay distinct from a vehicle-level approval. The illustrated braid is an electrical screen; this construction does not include steel-wire armor or a separate metallic conduit.

Typical Plant, Machine & Infrastructure Circuits

  • Railway equipment, power distribution and rolling-stock interconnections with specified fixed or moderately flexible routes and fire-performance requirements.

Route and equipment selection

Specify the whole installation context, including enclosures, routing and fire assessment. A material test classification does not by itself establish a complete vehicle hazard-level approval.

Compare related cable duties

  • DAA1093 AAR S-501 / RP-585 125°C XLPO DLO Diesel Locomotive Wire 600V/2000V
  • 2000V 4 0 535 DLO Diesel Locomotive Cable 90°C EPR-CPE RHH RHW-2 for Mining
  • 300 V EPDM/SBR Flexible Equipment Cable, AWM 4097

EN 50264-3-2 Screened Rolling Stock Power Specification & Selection FAQ

Why is 'Select the complete construction' critical when specifying EN 50264-3-2 Screened Rolling Stock Power Cable?

The representative has two insulated conductors and one overall braid. It is not a three-phase VFD layout and does not include a green/yellow protective core unless a different core schedule is ordered.

How should engineers address 'define the ordered acceptance conditions' for EN 50264-3-2 Screened Rolling Stock Power Cable?

Include the exact construction, applicable designations, dimensions and required inspections in the purchase specification. For motion, define the carrier or route geometry, temperature, speed, acceleration and cycle definition. For optical or RF links, include wavelengths or frequencies, interfaces, connections and the installed link acceptance criteria.

What is the engineering rule regarding 'route and equipment selection' on EN 50264-3-2 Screened Rolling Stock Power Cable?

Specify the whole installation context, including enclosures, routing and fire assessment. A material test classification does not by itself establish a complete vehicle hazard-level approval.

How are the conductors, insulation, and outer sheath structured in EN 50264-3-2 Screened Rolling Stock Power Cable?

Conductors: 2 × 35 mm² Class 5 tinned copper.; Insulation: Black XLPO with core identification.; Screen: Tinned-copper braid; nominal 80% coverage.; Outer jacket: Black XLPO.; Representative dimensions: 23.5 mm nominal finished diameter.

Use each value for the stated construction and operating condition. Nominal dimensions refer to the representative configuration; select the full size and installation schedule before ordering.

TEBAOFLEX® — EN 50264-3-2 Screened Rolling Stock Power Cable Construction, Operating & Compliance Matrix

EN 50264-3-2 Screened Rolling Stock Power Cable 4-Column Engineering Schedule
Cable Element / Layer Selected Construction Operating Parameter / Condition Normative Reference & Test Scope
Conductors 2 × 35 mm² Class 5 tinned copper. Rated voltage: 600/1000 V IEC 60228 — Conductor class reference.
Insulation Black XLPO with core identification. Conductor set: 2 × 35 mm², Class 5 tinned copper EN 50264-3-2 — Railway reduced-dimension multicore cable reference.
Screen Tinned-copper braid; nominal 80% coverage. Operating range: −40 to +120°C EN 45545-2 — Railway material fire-requirement reference.
Outer jacket Black XLPO. Nominal OD / mass: 23.5 mm / 939 kg/km IEC 60332-1-2 / IEC 60332-3-24 — Flame-test references.
Representative dimensions 23.5 mm nominal finished diameter. Braid coverage: 80% EN 50266-2-4 — Bunched-cable flame-test reference.

TEBAOFLEX® — EN 50264-3-2 Screened Rolling Stock Power Cable technical parameters

EN 50264-3-2 Screened Rolling Stock Power Cable technical parameters
Parameter Value / condition
Rated voltage 600/1000 V
Conductor set 2 × 35 mm², Class 5 tinned copper
Operating range −40 to +120°C
Nominal OD / mass 23.5 mm / 939 kg/km
Braid coverage 80%
Dielectric test 3.5 kV AC for 5 minutes
Material fire/toxicity scope R15/R16 HL3 references for insulation/jacket materials.

TEBAOFLEX® — EN 50264-3-2 Screened Rolling Stock Power Cable configuration comparison

EN 50264-3-2 Screened Rolling Stock Power Cable configuration comparison
Configuration Selection scope
Two-core screened power Representative configuration.
Other conductor areas Order a separate dimension and loading schedule.
Fixed installation Define supports, ambient conditions and terminations.
Moderate flexing Define movement and radius; separate from continuous carrier duty.

TEBAOFLEX® — Railway cable and fire-evidence boundaries

Railway cable and fire-evidence boundaries
Cable duty Construction and installation scope
Single-core DLO lead A separately designated flexible single-core equipment lead.
Screened rolling-stock multicore Two XLPO-insulated cores and an overall braid in this representative.
EN 50264-3-2 Reduced-dimension multicore railway cable reference.
R15/R16 HL3 material scope Keep insulation/jacket material evidence distinct from complete vehicle approval.

State the fire-evidence scope in the cable schedule

Write the required standard, requirement set, material or cable scope and applicable hazard level as separate fields. Attach that scope to the exact ordered construction and installation context. This makes railway procurement clearer than compressing several different material tests into an unrestricted whole-vehicle approval claim.

Add vehicle termination, vibration exposure and movement requirements to the circuit and temperature schedule.

Selection guide: Send the circuit schedule, route drawing, connection details and required quantity with your inquiry. Our engineers can coordinate the selected cable construction, finished dimensions, installation conditions and delivery lengths with your equipment specification. Include required reel lengths, installation markings and inspection documents so the delivery schedule matches the project.

Ordering & Quotation Checklist: Send voltage, area, core count, fire requirement/scope, equipment route, movement, ambient temperature and screen termination.

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for EN 50264-3-2 Screened Rolling Stock Power Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.

  • ISO 9001 Factory Direct
  • MOQ 50 m (Custom Builds)
  • 24h Engineering Reply
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    You may also like…

    EN 50264-3-2 Screened Rolling Stock Power CableGet A Quote