400°C Steel-Armoured Fiberglass Thermocouple Profiling Cable (IEC 60584)

Running furnace temperature uniformity surveys (TUS) or turbine exhaust rigs destroys bare fiberglass thermocouple wires as soon as oven doors close or steel charge baskets shift. Dense steel or 304 stainless wire-braid armor delivers door-pinch survival without compromising EMF calibration.

  • Continuous Temp: Up to +400 °C special glass | +250 °C PFA/SSWA tier;
  • Thermocouple Types: IEC 60584 K (NiCr-Ni), J (Fe-CuNi), N, E, T, S/B;
  • EMF Tolerance Grade: Standard Class 2 & tight Class 1 (±1.5 °C @ 400 °C);
  • Core Architecture: 2-core pair & 4-core quad (0.22, 0.50, 1.0, 1.5 mm²);
  • Outer Mechanical Armor: Galvanized steel wire or VA 304 stainless braid;
  • Nominal Outer Dia.: Slim 3.1 mm to 5.6 mm OD (12×d bend radius);
  • Color Coding: IEC 60584-3 (Green/White Type K) or ANSI MC96.1;
  • MOQ & Lead Time: 50 m minimum | 7–45 working days factory calibrated;

Calibrated Alloy Pairs, Special Fiberglass & SWA/VA Steel Armor

  • Category: Instrumentation & Signal Cable
  • Continuous Temp: Up to +400 °C special glass | +250 °C PFA/SSWA tier
  • Thermocouple Types: IEC 60584 K (NiCr-Ni), J (Fe-CuNi), N, E, T, S/B
  • EMF Tolerance Grade: Standard Class 2 & tight Class 1 (±1.5 °C @ 400 °C)

+400°C Continuous Kiln Survey & +250°C PFA+SSWA Hybrid Envelope

  • Core Architecture: 2-core pair & 4-core quad (0.22, 0.50, 1.0, 1.5 mm²)
  • Outer Mechanical Armor: Galvanized steel wire or VA 304 stainless braid
  • Nominal Outer Dia.: Slim 3.1 mm to 5.6 mm OD (12×d bend radius)
  • Color Coding: IEC 60584-3 (Green/White Type K) or ANSI MC96.1
  • MOQ & Lead Time: 50 m minimum | 7–45 working days factory calibrated

Matched IEC 60584 K/J/N/R/S Alloys, Dual Glass & 304 VA / Steel Braid

Zero-halogen ceramic/fiberglass thermal stack engineered around calibrated IEC 60584 / ANSI alloy pairs with full steel wire braid armor.

  • Calibrated IEC 60584 Thermocouple Cores: Fine-stranded 7/0.20, 16/0.20, or 32/0.20 mm (0.22–1.00 mm² & 1.5 mm²) Type K, J, N, T, E, or R/S/B matched thermocouple alloys
  • Special +400°C Glass or +250°C PFA Wrap: Halogen-free special high-temperature impregnated fiberglass insulation (+400 °C) or extruded PFA moisture wall (+250 °C wet option)
  • Color-Coded Tracer Coding: Woven IEC 60584-3 or ANSI MC96.1 negative/positive leg identification threads along both cores and outer braid
  • Overall Fiberglass Thermal Binder: Tight protective fiberglass sleeve uniting twin or quad pairs (0.22–1.0 mm²) evenly prior to armor braiding
  • Galvanized Steel or VA 304 Stainless Armor: High-coverage woven steel wire braid deflecting sharp oven edges, refractory brick grit, and heavy door pinch force

Galvanized Steel vs VA 304 Stainless Armor & Preventing Ground Loops

Galvanized zinc-coated steel armor delivers strong abrasion toughness in dry air up to +250–300 °C before zinc begins scaling; above +300 °C or in corrosive flue gases, specify VA 304 stainless-steel wire braiding, which remains corrosion-free continuously at +400 °C+.

  • Minimum 12×d Dynamic Radius: Observe 12 × cable OD when coiling reusable TUS survey tails between furnace batches to prevent kinking alloy conductors.
  • Dedicated Alloy Plugs Only: Never insert ordinary copper terminal blocks inline—always maintain matching thermocouple alloy pins (Type K / J / N) all the way to cold junction.

Class 1 ±1.5°C EMF Precision, 3.1–5.6 mm Slim OD & 12×d Flex

  • Class 1 ±1.5°C Profiling: Meets strict aerospace/automotive AMS 2750 furnace uniformity audits
  • 304 Stainless vs Galv Armor: Pick VA 304 for oxidizing/acidic flue gas; galvanized for dry trays
  • Dual Special Fiberglass: Upgrades standard +250°C glass up to true +400°C continuous furnace zone
  • 250°C Sealed PFA+SSWA Opt.: PFA core dielectric + fiberglass + SSWA blocks steam & oil coolant
  • True 3.1–5.6 mm Slim Profile: Fits snugly underneath heavy furnace door seals with zero jam damage

Door-Pinch Immunity, Zero Millivolt Drift & ANSI/IEC Tracer Match

  • Tight Class 1 ±1.5°C EMF Verification: Optional batch-certified Class 1 NiCr-Ni (Type K) and NiCrSi-NiSi (Type N) alloys support aerospace heat-treat surveys.
  • True 400°C Dry vs 250°C Wet Families: Select special glass + VA braid (+400 °C dry heat) or PFA + glass + VA braid (+250 °C oil/condensate sealing).
  • Compact 3.1 mm – 5.6 mm Outside Diameter: Passes through crowded furnace vestibule slots and multi-point TUS jacking collars effortlessly.
  • Halogen-Free Safe Combustion Gases: IEC 60754-1/-2 compliant glass/steel chemistry ensures clean outgassing inside vacuum or atmosphere furnaces.
  • Custom Quad (4-Core) & 50 m Small Coils: Supports dual-sensor (4×0.22–1.00 mm²) armored probes cleanly from 50 m MOQ.

IEC 60584-3 Class 1/2 EMF, IEC 60332-3-24 & IEC 60754 Halogen-Free

  • IEC 60584-3 Class 1 & Class 2 EMF: Thermoelectric EMF calibration and color identification (ANSI MC96.1 option available)
  • IEC 60332-3-24 & IEC 60332-1-2 Fire: No vertical bunched or single-cable flame propagation (Non-combustible outer armor)
  • IEC 60754-1/-2 Halogen-Free Gas: Zero corrosive acid gas generation on +400 °C special fiberglass insulated series

Thermocouple Calibration, High-Heat Alloy & Instrumentation Guides

EMF Batch Calibration, Resistance Symmetry & Armor Continuity

Every coil of TEBAOFLEX® +400°C armoured thermocouple cable passes calibration and mechanical verification prior to dispatch:

  • Lot-Matched EMF Accuracy Check: Verifies thermoelectric output curve (mV @ 100 °C / 400 °C) against IEC 60584 Class 1/2 error bands.
  • Dielectric Core-to-Armor Spark Test: Checks 1,000–1,500 VAC withstand ensuring glass fibers keep thermocouple wires cleanly isolated from steel armor.
  • Alloy Tracer & Color Code Audit: Confirms polarity orientation (Positive / Negative legs) and tracer weave durability along full spool length.
Bright stainless-steel wire-braided +400C armoured thermocouple extension cables routed neatly out of aluminum heat-treatment furnace door ports alongside alloy thermocouple terminal heads
Aluminum heat-treatment soaking furnace vestibule: +400°C 304 stainless-armoured special-fiberglass thermocouple survey leads routed cleanly toward batch uniformity probes.

Heat-Treatment TUS Profiling, Soaking Pits & Turbine Exhaust Rigs

Heat-treatment Temperature Uniformity Surveys (TUS), brick-kiln car drags, and gas-turbine test stands subject thermocouple cables to two brutal hazards simultaneously: +350 °C to +400 °C continuous thermal soaking plus harsh rubbing against furnace jambs, metal charge trays, and door counterweights. Conventional 200 °C–260 °C fluoropolymer probe leads soften under compressed seals, while unarmoured glass braids unravel within a handful of batch cycles.

TEBAOFLEX® 400°C Steel-Armoured Fiberglass Thermocouple Cable suspends true matched IEC 60584 thermocouple conductors (7×0.20 mm = 0.22 mm², 16×0.20 mm = 0.50 mm², 32×0.20 mm = 1.00 mm², or 1.5 mm²) inside dual impregnated special high-temperature glass-fiber braids, locked beneath a tightly woven galvanized steel wire braid or oxidation-resistant VA 304 stainless-steel wire armor (3.1–5.6 mm OD). Where washdown oil, quenching mist, or condensing steam accompanies heavy mechanical abrasion up to +250 °C, our PFA-core + fiberglass + steel/stainless braid builds provide sealed moisture immunity.

Available in IEC 60584-3 (Type K Green/White, Type J Black/White, Type N Pink/White) or ANSI MC96.1 (Yellow/Red Type K) color tracers from 50 m calibrated coils. Pair with530°C Shielded RTD Kiln Sensor Cablefor Pt100 probes, or check260°C Unarmoured FEP/PFA Thermocouple WireandControl-Room Multi-Pair KX/JX Extension Cablesfor panel trunk runs.

For adjacent 300 V +450 °C cartridge-heater hook-up leads inside the same heated zone, pair cleanly with compactUL 5360 450°C 300V Mica-Glass Wire.

NADCAP/AMS 2750 Furnace Surveys, Ingot Baskets & Exhaust Skids

  • Aluminum solution-treatment plants, turbine test engineers, and industrial kiln builders use TEBAOFLEX® 400°C Steel-Armoured Thermocouple Cable wherever unarmoured leads fray or short-circuit under mechanical clamping.
  • Always isolate armored metal braids electrically from bare hot-junction ground welds inside differential PLC input cards unless grounded probes are specifically required.
  • AMS 2750 Furnace Temperature Surveys (TUS): Class 1 Type K / N armoured survey tails pinched safely beneath weighted heat-treatment doors.
  • Gas Turbine & Jet Engine Exhaust Rigs: High-flex 304 VA stainless-braided thermocouple jumpers surviving vibration near diffuser casings.
  • Aluminum Billet Soaking & Forging Ovens: Door-mounted load thermocouples shielded against billet tongs and falling oxide scale.
  • Chemical Reactor Jackets (250°C PFA+SSWA): Oil- and vapor-tight PFA + fiberglass + VA 304 armor for splash-heavy distillation columns.

Industrial Thermocouple Extension Cable Matrix (200°C to +400°C)

Match insulation chemistry and mechanical armor cleanly to each point along your measurement chain:

Comparing +400°C Steel-Armoured Glass vs +250°C PFA+SSWA vs Unarmoured Probe & Trunk Cables
Thermocouple Cable Series Temp Limit Armor / Sheath Accuracy Option Field Segment
400°C Special Glass + VA/Galv Armor (This Page) +400 °C (Dry) 304 Stainless / Galv Steel Braid IEC Class 1 / Class 2 Hot oven zones, furnace doors & turbine skids
250°C PFA + Glass + SSWA Variant (This Page) +250 °C (Sealed) PFA + Glass + 304 SS Braid IEC Class 1 / Class 2 Wet/oil-mist process vessels & washdown frames
260°C Duplex FEP/PFA Sensor Wire +200 / +260 °C Unarmoured Extruded FEP/PFA IEC / ANSI Standard & Special Compact dry thermowell tails & probe sleeves
Multi-Pair Foil-Screened Trunk Cable +105 / +200 °C PVC / Silicone / FEP Multi-Pair Extension / Compensating Control-room multi-pair tray runs back to DCS

400°C Steel-Armoured Fiberglass Thermocouple Cable FAQ

Should I specify VA 304 stainless-steel armor or galvanized steel armor for +400°C ovens?

Specify VA 304 stainless-steel wire armor whenever continuous temperatures exceed 300°C, oxidizing furnace exhaust is present, or coils are reused repeatedly for furnace uniformity surveys. Galvanized steel armor works best in dry, clean mechanical tray runs.

Can I get IEC 60584 Class 1 (±1.5°C) calibration certification on these cables?

Yes. Both Class 2 standard and tight Class 1 (±1.5°C) calibrated Type K and Type N coils are manufactured from traceable alloy heats upon request (50 m MOQ).

Why are 4-core (quad) thermocouple cables stocked alongside standard 2-core pairs?

Dual-element probes or simultaneous load + safety over-temp thermocouples feed cleanly through one compact 3.5–5.6 mm armoured jacket instead of threading two vulnerable separate wires.

Is the +400°C special fiberglass thermocouple cable waterproof?

Fiberglass braids are inherently breathable and not immersion waterproof. If oil mist, steam, or quenching splash hits your cable path below +250°C, specify our TBX-TC250-PFA extruded-PFA core variant underneath 304 SSWA armor.

What is the MOQ and lead time?

MOQ is 50 m per thermocouple alloy and core configuration, with typical delivery in 7–45 working days.

Standard dimensional schedule covering +400°C Special Fiberglass Steel-Armoured (Th-LRS / VA) and +250°C Waterproof PFA + Stainless-Armoured (PFA/SSWA) IEC 60584 Thermocouple Extension Cables.

TEBAOFLEX® — +400°C Steel/VA-Armoured Special Fiberglass & +250°C PFA/SSWA Thermocouple Schedule

Matched Type K (NiCr-Ni), Type J (Fe-CuNi) & Type N Conductors | 12×d Bend | IEC 60584 Class 1 / Class 2
Part Code Dielectric & Armor Tier Cores × mm² Wire Geometry Temp Range Approx. OD Approx. Weight
TBX-TC400-2X022 +400°C Special Glass + Galv/VA 2 × 0.22 mm² 7 × 0.20 mm +400 °C cont. 3.1 mm 19–20 kg/km
TBX-TC400-2X050 +400°C Special Glass + Galv/VA 2 × 0.50 mm² 16 × 0.20 mm +400 °C cont. 3.7 mm 32–39 kg/km
TBX-TC400-2X100 +400°C Special Glass + Galv/VA 2 × 1.00 mm² 32 × 0.20 mm +400 °C cont. 4.5 mm 43–52 kg/km
TBX-TC400-4X022 +400°C Special Glass (Quad) 4 × 0.22 mm² 7 × 0.20 mm +400 °C cont. 3.5 mm 29 kg/km
TBX-TC400-4X050 +400°C Special Glass (Quad) 4 × 0.50 mm² 16 × 0.20 mm +400 °C cont. 4.2 mm 43–51 kg/km
TBX-TC400-4X100 +400°C Special Glass (Quad) 4 × 1.00 mm² 32 × 0.20 mm +400 °C cont. 5.4 mm 70–75 kg/km
TBX-TC250-PFA-2X022 +250°C Sealed PFA + VA 304 2 × 0.22 mm² 7 × 0.20 mm +250 °C cont. 3.2 mm 19–21 kg/km
TBX-TC250-PFA-2X050 +250°C Sealed PFA + VA 304 2 × 0.50 mm² 16 × 0.20 mm +250 °C cont. 4.1 mm 39 kg/km
TBX-TC250-PFA-2X100 +250°C Sealed PFA + VA 304 2 × 1.00 mm² 32 × 0.20 mm +250 °C cont. 4.9 mm 52 kg/km
TBX-TC250-PFA-4X050 +250°C Sealed PFA + VA (Quad) 4 × 0.50 mm² 16 × 0.20 mm +250 °C cont. 4.7 mm 51 kg/km
TBX-TC250-PFA-4X100 +250°C Sealed PFA + VA (Quad) 4 × 1.00 mm² 32 × 0.20 mm +250 °C cont. 5.6 mm 75 kg/km

Selection guide: Specify Type K or Type N Class 1 (±1.5 °C) with VA 304 stainless wire armor for repeat furnace TUS runs above 300 °C; specify PFA/SSWA where liquid coolants or washdown sprays reach cable sheaths.

Ordering & Quotation Checklist: Specify thermocouple type (K / J / N / T / E / R/S/B), Class 1 vs Class 2 tolerance, 2C vs 4C, steel vs 304 SS braid armor, and color code (IEC vs ANSI, MOQ 50 m).

530°C Nickel-Cu Mica/PTFE/Glass Shielded & SSWA RTD Kiln Sensor Cable

530°C Nickel-Cu Mica/PTFE/Glass Shielded & SSWA RTD Kiln Sensor Cable

Up to +530 °C (986 °F) extreme | +250–400 °C SSWA

VIEW PRODUCT »

Duplex FEP, PFA & Sintered PTFE Thermocouple Sensor Wire

Duplex FEP, PFA & Sintered PTFE Thermocouple Sensor Wire

True Sensor Grade: Type K, J, T, E & N (Class 1 / SLE)

VIEW PRODUCT »

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for 400°C Steel-Armoured Fiberglass Thermocouple Profiling Cable (IEC 60584)? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.

  • ISO 9001 Factory Direct
  • MOQ 50 m (Custom Builds)
  • 24h Engineering Reply
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    400°C Steel-Armoured Fiberglass Thermocouple Profiling Cable (IEC 60584)Get A Quote