Duplex FEP, PFA & Sintered PTFE Thermocouple Sensor Wire
Engineered for direct hot-junction measurement where extension-grade wire drifts out of tolerance, TEBAOFLEX® true thermocouple-grade FEP, PFA, and sintered PTFE duplex sensor wires maintain Class 1 / SLE microvolt fidelity from cryogenic -200°C nitrogen baths to +260°C pressurized autoclaves.
- Calibration Types: True Sensor Grade: Type K, J, T, E & N (Class 1 / SLE);
- Thermal Envelope: -200 °C to +260 °C (PFA & PTFE) | -90 °C to +200 °C (FEP);
- Gauge Span: 40, 36, 30, 24 & 20 AWG Solid | 24S, 22S, 20S (7-Strand);
- EMF Tolerance: IEC 60584-1 Class 1 | ASTM E230 Special Limits (SLE);
- Dielectric Formats: Melt-Extruded PFA, Extruded FEP & Fused Sintered PTFE;
- Profile Geometry: Parallel Oval Rip-Duplex | Twisted Round | TWSH Screened;
- EMI Shielding: Unshielded, Foil + Drain (TWSH) or >=85% Tinned Cu Braid;
- Color Standards: ANSI MC96.1 (Brown/Color) or IEC 60584-3 (Green/Black/etc.);
Sensor-Grade Duplex Thermocouple Wire Scope
- Category: Instrumentation & Signal Cable
- Calibration Types: True Sensor Grade: Type K, J, T, E & N (Class 1 / SLE)
- Thermal Envelope: -200 °C to +260 °C (PFA & PTFE) | -90 °C to +200 °C (FEP)
- Gauge Span: 40, 36, 30, 24 & 20 AWG Solid | 24S, 22S, 20S (7-Strand)
-200°C to +260°C Thermal Window & EMF Accuracy
- EMF Tolerance: IEC 60584-1 Class 1 | ASTM E230 Special Limits (SLE)
- Dielectric Formats: Melt-Extruded PFA, Extruded FEP & Fused Sintered PTFE
- Profile Geometry: Parallel Oval Rip-Duplex | Twisted Round | TWSH Screened
- EMI Shielding: Unshielded, Foil + Drain (TWSH) or >=85% Tinned Cu Braid
- Color Standards: ANSI MC96.1 (Brown/Color) or IEC 60584-3 (Green/Black/etc.)
Matched Thermoelement Alloys, Fluoropolymer & TWSH
Matched single-melt thermocouple alloy pairs insulated in pinhole-free fluoropolymers for zero cold-work drift, vacuum sealability, and chemical immunity.
- Calibrated Alloy Conductors: Matched sensor-grade positive/negative thermoelements (Type K, J, T, E, N) in solid (40, 36, 30, 24, 20 AWG) or flexible 7-strand (24S = 7/32, 22S = 7/30, 20S = 7/28, 0.22 mm² = 7×0.20 mm)
- Primary Core Dielectric: Color-coded virgin melt-extruded PFA (+260 °C), melt-extruded FEP (+200 °C), or wrapped & thermally fused sintered PTFE tape (+260 °C)
- Parallel vs Twisted Layup: Flat oval rip-cord duplex (easy-strip parallel cores) for miniature bead welding, or precision short-lay twisted pair for magnetic hum cancellation
- EMI / RFI Screening (TWSH / C): Optional 100% aluminum-polyimide/PET foil tape + stranded tinned copper drain wire (TWSH), or ≥85% tinned/silver-plated copper wire braid (FEP/C/FEP)
- Outer Fluoropolymer Jacket: Continuous extruded PFA, FEP, or fused sintered PTFE outer sheath coded to ANSI MC96.1 (Brown overall for SLE/Thermocouple Grade) or IEC 60584-3 (Green K, Black J, Brown T, Violet E, Pink N)
Thermocouple Sensor Wire (K, J, T, E, N) vs Extension Wire (KX, JX) & Loop Resistance
Extension-grade KX or JX cables are only calibrated between 0 °C and +200 °C to carry signals through ambient cable trays. Whenever the wire itself enters a -196 °C cryo chamber or +250 °C autoclave, specify sensor-grade (K, J, T, E, N) duplex wire. Review full jacket rules in ourPFA, ETFE & Thermocouple Wire Guideand convert AWG gauges via ourAWG to mm² Converter.
- Loop Resistance per Meter (20 °C, Pair Sum): Type K (0.99 Ω·mm²/m loop): 20 AWG ≈ 1.93 Ω/m, 24 AWG ≈ 4.88 Ω/m, 30 AWG ≈ 19.6 Ω/m | Type T (0.51 Ω·mm²/m loop): 20 AWG ≈ 0.99 Ω/m, 24 AWG ≈ 2.50 Ω/m.
- Never Splice Copper Into a Thermocouple Loop: Terminating Type K or Type T leads onto plain copper terminal blocks creates parasitic cold junctions; always land on alloy-matched isothermal blocks or direct transmitter inputs.
Gauge Span, EMF Limits & Loop Resistance Metrics
- Type K / N SLE Error: ±1.1 °C or ±0.4% (ASTM SLE) | ±1.5 °C or ±0.004·|t| (IEC Cl.1)
- Type T Cryo Precision: ±0.5 °C or ±0.4% (SLE / Class 1) for -200 °C to +260 °C
- Ultrafine Response: 40 AWG (0.08 mm) & 36 AWG (0.127 mm) sub-millimeter beads
- Vacuum Outgassing: Pinhole-free extruded PFA resists autoclave resin & vacuum leak
- Supply Format: MOQ 50 m | Calibrated Lot Spools | 7–45 Working Days
Zero Moisture Wicking, Autoclave Integrity & Micro-OD
- True Sensor-Grade Calibration (-200 °C to +260 °C): Unlike extension-grade KX/JX wires limited to +200 °C, sensor-grade melts are EMF-verified across the entire cryogenic-to-260 °C fluoropolymer span.
- 40 AWG to 20 AWG Micro-Bead & Heavy-Duty Range: Ultrafine 40 AWG (0.079 mm) and 36 AWG (0.127 mm) solid pairs achieve millisecond thermal step response on IC packages, microfluidic cells, and thin-film substrates.
- Vacuum-Bag Sealant Integrity (Extruded PFA): Smooth round or oval extruded PFA seals cleanly through tacky butyl tape without capillary air leaks during aerospace autoclave composite cures.
- Twisted-Shielded (TWSH) SCR & Induction Noise Rejection: Tight pair twist combined with 100% foil + drain or tinned copper braid suppresses 50/60 Hz and kHz thyristor firing spikes on electric furnace zones.
- Total Acid, Solvent & Steam Sterilization Immunity: Fluoropolymer insulation resists concentrated acids, etching baths, hydraulic ester fluids, and repeated 134 °C WFI steam autoclave cycles without embrittlement.
- Dual ANSI MC96.1 & IEC 60584-3 Color Coding: Supplied in North American ANSI (Brown thermocouple-grade jacket with Yellow/Red, White/Red, Blue/Red) or international IEC 60584-3 color schemes.
ASTM E230 / ANSI MC96.1, IEC 60584-1/3 & AMS 2750
- ASTM E230 / ANSI MC96.1: Temperature-Electromotive Force (EMF) Tables & Special/Standard Limits of Error for Thermocouples
- IEC 60584-1 & IEC 60584-3: International Thermocouple EMF Tolerances (Class 1 / Class 2) & Insulation Color Coding
- SAE AMS 2750 (Pyrometry): Aerospace Heat-Treating & Autoclave Load-Thermocouple Accuracy Support (SLE / Class 1)
- UL 1581 VW-1 & IEC 60332-1-2: Inherent Fluoropolymer Non-Flammability (LOI > 95% for PTFE/PFA/FEP)
Thermocouple Calibration & Fluoropolymer Wire Guides
Thermocouple Calibration, Color Code & Tolerance Reference (IEC 60584 vs ANSI MC96.1)
Verify both calibration letter and regional color standard before ordering—note that Red is ALWAYS the negative (-) leg in ANSI MC96.1!
Type K (Ni-Cr / Ni-Al)
-200 °C to +260 °C (wire limit) | IEC: Green (+) / White (-), Green jacket | ANSI: Yellow (+) / Red (-), Brown sensor jacket | SLE: ±1.1 °C or 0.4%.
Type J (Fe / Cu-Ni)
-40 °C to +260 °C | IEC: Black (+) / White (-), Black jacket | ANSI: White (+) / Red (-), Brown sensor jacket | SLE: ±1.1 °C or 0.4%.
Type T (Cu / Cu-Ni)
-200 °C to +260 °C (best cryo/pharma) | IEC: Brown (+) / White (-), Brown jacket | ANSI: Blue (+) / Red (-), Brown sensor jacket | SLE: ±0.5 °C or 0.4%.
Type E (Ni-Cr / Cu-Ni)
-200 °C to +260 °C (highest µV/°C output) | IEC: Violet (+) / White (-) | ANSI: Purple (+) / Red (-) | SLE: ±1.0 °C or 0.4%.
Type N (Ni-Cr-Si / Ni-Si)
-200 °C to +260 °C (low drift) | IEC: Pink (+) / White (-) | ANSI: Orange (+) / Red (-) | SLE: ±1.1 °C or 0.4%.
Batch EMF Calibration, Spark Dielectric & Pinhole Continuity Verification
Every production lot of TEBAOFLEX® fluoropolymer thermocouple sensor wire undergoes traceable metrological and dielectric inspection:
- Multi-Point Thermoelectric EMF Calibration: Positive and negative melt pairs are verified against reference standards per ASTM E220 / IEC 60584-1 to certify Class 1 / SLE deviation values.
- 100% Dry High-Frequency Spark & 1.5–2.0 kV Dielectric Test: Confirms pinhole-free core and jacket wall integrity along the entire spool length.
- Dimensional Ovality & Weldability Check: Verifies concentric wall thickness for clean laser/TIG bead junction welding even on 36 AWG and 40 AWG micro-pairs.

Autoclave Bagging, Wafer Ovens, Cryogenics & Furnaces
Whereas cold-zone marshalling trunks stop at ambient junction heads (≤ +200 °C extension grade), direct thermal profiling inside composite curing autoclaves, pharmaceutical lyophilizers, semiconductor bake plates, cryogenic freezers, and AMS 2750 aerospace furnaces requires true thermocouple-grade alloy conductors whose Seebeck electromotive force (EMF) stays calibrated all the way across -200 °C to +260 °C. TEBAOFLEX® manufactures precision-matched Type K (Ni-Cr / Ni-Al), Type J (Fe / Cu-Ni), Type T (Cu / Cu-Ni), Type E (Ni-Cr / Cu-Ni), and Type N (Ni-Cr-Si / Ni-Si-Mg) duplex sensor wires insulated with virgin melt-extruded PFA, extruded FEP, or fused sintered PTFE tape.
Choosing the right fluoropolymer architecture solves critical field failure modes. Continuous melt-extruded PFA (-200 °C to +260 °C) forms a smooth, non-porous gas-tight skin that will not wick moisture in steam sterilizers or allow air ingress through vacuum bagging sealant tape during 7–10 bar carbon-fiber autoclave cures. Extruded FEP (-90 °C to +200 °C) provides an economical, low-friction parallel oval or round cable (including 2×0.22 mm² copper-braided FEP/C/FEP) for food retorts, environmental chambers, and laboratory probes. Fused sintered PTFE tape (-200 °C to +260 °C) eliminates melt flow under tight clamp pressure while delivering a slim, abrasion-tough 1.3×1.9 mm (24 AWG) flat profile.
Where variable-frequency induction heaters, thyristor SCR furnace packs, or RF plasma generators corrupt microvolt thermocouple loops, our Twisted-Shielded (TWSH) series twists the calibrated pair at a tight lay pitch inside 100% aluminized polyester foil plus a tinned copper drain wire—or an 85% tinned/silver-plated copper braid (FEP/C/FEP & PFA/SPC/PFA). For multi-pair trunk marshalling from the terminal head back to the DCS cabinet, pair these sensor leads withThermocouple Extension & Compensating Cable (KX, JX, TX, EX, NX); for 4-wire platinum resistance sensing, compareIEC 60751 Screened FEP, PFA & PTFE Pt100 / Pt1000 RTD Cable.
Aerospace Composite Cure, Lyophilizers & Engine Cells
- Precision thermal validation engineers specify TEBAOFLEX® fluoropolymer duplex thermocouple wire wherever standard fiberglass braids shed particulates or wick humidity, and wherever PVC/silicone insulations soften, outgas siloxanes, or contaminate cleanrooms.
- Select solid 30–40 AWG PFA for surface-attached semiconductor chuck and catheter-tip sensors; 7-strand 20S/24S extruded PFA for reusable autoclave load thermocouples; and foil- or braid-screened TWSH / FEP/C/FEP around induction coils, VFD-driven extruders, and battery thermal-runaway chambers.
- Aerospace Composite Autoclaves & AMS 2750 Ovens: 20 AWG & 20S (7/28) extruded PFA Type J and Type K SLE load leads passing through vacuum-bag perimeter tacky tape.
- Pharmaceutical Freeze-Dryers (Lyophilizers) & Steam SIP: Type T (Cu/Cu-Ni) Class 1 PFA and FEP micro-pairs tracking vial temperatures from -85 °C freezing shelves to +135 °C steam sterilization.
- Semiconductor Wafer Chucks, Cleanrooms & Lab Probes: Particulate-free 30, 36, and 40 AWG virgin PFA pairs with zero siloxane outgassing.
- Cryogenic LNG, Liquid Nitrogen & Superconducting Rigs: Sintered PTFE and PFA Type T / Type E pairs maintaining ductility down to -200 °C.
Extruded PFA vs Extruded FEP vs Fused Sintered PTFE Thermocouple Dielectric Matrix
Match the fluoropolymer dielectric process to your operating temperature, vacuum seal, and abrasion environment:
| Dielectric Process | Temp. Range | Moisture / Vacuum Seal | Mechanical & Flex Trait | Best Sensor Application |
|---|---|---|---|---|
| Melt-Extruded PFA | -200 °C to +260 °C | Hermetic pinhole-free skin | High flex life & creep resistance | Autoclaves, cleanrooms, cryo & chemical |
| Melt-Extruded FEP | -90 °C to +200 °C | Excellent non-wetting skin | Smooth low-friction easy strip | Lyophilizers, food retorts & HVAC probes |
| Fused Sintered PTFE | -200 °C to +260 °C | Moisture-proof (wrapped seam) | Zero melt flow under clamp load | Hot platen clamps, cryo & compact harnesses |
| Extension KX/JX (PVC/FEP) | -40 °C to +200 °C | Jacketed 1–24 pair trunk | Multipair marshalling economy | Ambient tray routing to DCS cabinet |
Duplex Fluoropolymer Thermocouple Sensor Wire FAQ
What is the difference between sensor-grade Type K/T/J wire and extension-grade KX/TX/JX wire?
Sensor-grade thermocouple wire (K, J, T, E, N) is drawn from tighter-tolerance melts verified across the full -200 °C to +260 °C insulation window so the hot measuring bead can be welded directly at the wire tip. Extension-grade wire (KX, JX, TX) is only calibrated up to +200 °C for ambient marshalling runs.
Why do aerospace composite autoclaves require melt-extruded PFA rather than wrapped PTFE or fiberglass?
During carbon-fiber autoclave curing under 6–10 bar pressure and vacuum bagging, wrapped tapes or braided fiberglass create micro-channels that leak air through perimeter sealant tape and wick moisture. Continuous melt-extruded PFA provides a smooth, non-porous surface that seals gas-tight.
Which calibration is most accurate for pharmaceutical lyophilizers and cryogenic -196 °C liquid nitrogen?
Type T (Copper / Copper-Nickel) in IEC Class 1 or ASTM Special Limits of Error (SLE) delivers ±0.5 °C (or ±0.4%) tolerance and exceptional homogeneity from -200 °C to +260 °C, making it the benchmark for vial freeze-drying and cryogenic validation.
When should I choose 7-strand (20S, 24S) over solid thermocouple sensor wire?
Specify 7-strand constructions (such as 20S = 7/28 or 24S = 7/32) whenever sensor leads are repeatedly coiled, routed across hinged oven doors, or reused across multiple autoclave load cycles where solid conductors could work-harden.
How should the foil/drain or copper braid shield on TWSH thermocouple wire be grounded?
Ground the shield drain wire or tinned copper braid at one end only—typically at the instrumentation cabinet or recorder analog-input ground bar—while insulating the shield at the hot-junction tip to prevent ground-loop currents.
What are the minimum order quantity and delivery lead times?
Standard MOQ is 50 m per calibration and gauge supplied on continuous calibrated spools, with production lead times of 7–45 working days.
Complete dimensional, stranding, insulation wall, and nominal weight schedules across Tier 1 Extruded PFA (-200/+260°C), Tier 2 Extruded FEP (-90/+200°C), Tier 3 Fused Sintered PTFE (-200/+260°C), and Tier 4 Twisted-Shielded (TWSH / Braided) sensor wires.
TEBAOFLEX® — Duplex FEP, PFA & Sintered PTFE Thermocouple Sensor Wire Dimensional Schedule
| Series Code | AWG / Metric Gauge | Stranding (mm) | Core / Jacket Wall (mm) | Nominal OD (mm) | Approx. Weight (kg/km) |
|---|---|---|---|---|---|
| Tier 1 — Melt-Extruded PFA Duplex Sensor Wire (-200 °C to +260 °C, Parallel Oval Profile) | |||||
| TBX-TC-PFA-20 | 20 AWG (0.52 mm²) | Solid (1 × 0.81) | 0.25 / 0.25 PFA | 1.7 × 3.0 | 16.7 |
| TBX-TC-PFA-20S | 20S AWG (0.56 mm²) | 7 × 0.32 (7/28) | 0.25 / 0.25 PFA | 1.9 × 3.2 | 16.7 |
| TBX-TC-PFA-22S | 22S AWG (0.35 mm²) | 7 × 0.254 (7/30) | 0.25 / 0.25 PFA | 1.7 × 3.4 | 13.3 |
| TBX-TC-PFA-24 | 24 AWG (0.205 mm²) | Solid (1 × 0.51) | 0.20 / 0.20 PFA | 1.4 × 2.4 | 10.0 |
| TBX-TC-PFA-24S | 24S AWG (0.22 mm²) | 7 × 0.20 (7/32) | 0.20 / 0.20 PFA | 1.6 × 2.6 | 10.0 |
| TBX-TC-PFA-30 | 30 AWG (0.051 mm²) | Solid (1 × 0.254) | 0.10 / 0.13 PFA | 0.6 × 1.0 | 3.3 |
| TBX-TC-PFA-36 | 36 AWG (0.013 mm²) | Solid (1 × 0.127) | 0.09 / 0.10 PFA | 0.5 × 0.8 | 1.8 |
| TBX-TC-PFA-40 | 40 AWG (0.005 mm²) | Solid (1 × 0.079) | 0.08 / 0.09 PFA | 0.4 × 0.7 | 1.2 |
| Tier 2 — Melt-Extruded FEP Duplex Sensor Wire (-90 °C to +200 °C, Oval & Round Profiles) | |||||
| TBX-TC-FEP-20 | 20 AWG (0.52 mm²) | Solid (1 × 0.81) | 0.25 / 0.25 FEP | 1.7 × 3.0 | 16.5 |
| TBX-TC-FEP-20S | 20S AWG (0.56 mm²) | 7 × 0.32 (7/28) | 0.25 / 0.25 FEP | 1.9 × 3.2 | 16.5 |
| TBX-TC-FEP-24 | 24 AWG (0.205 mm²) | Solid (1 × 0.51) | 0.20 / 0.20 FEP | 1.4 × 2.3 | 9.8 |
| TBX-TC-FEP-022-OV | 2 × 0.22 mm² (~24S) | 7 × 0.20 Stranded | 0.20 / 0.25 FEP | 1.5 × 2.5 | 10.5 |
| TBX-TC-FEP-022-RD | 2 × 0.22 mm² (~24S) | 7 × 0.20 Twisted | 0.20 / 0.25 FEP | 2.0 (Round) | 11.2 |
| Tier 3 — Fused Sintered PTFE Tape Duplex Sensor Wire (-200 °C to +260 °C, Slim Oval Profile) | |||||
| TBX-TC-PTFE-20 | 20 AWG (0.52 mm²) | Solid (1 × 0.81) | 0.18 / 0.18 PTFE | 1.5 × 2.5 | 13.8 |
| TBX-TC-PTFE-20S | 20S AWG (0.56 mm²) | 7 × 0.32 (7/28) | 0.18 / 0.18 PTFE | 1.5 × 2.7 | 14.2 |
| TBX-TC-PTFE-24 | 24 AWG (0.205 mm²) | Solid (1 × 0.51) | 0.15 / 0.15 PTFE | 1.3 × 1.9 | 8.4 |
| TBX-TC-PTFE-24S | 24S AWG (0.22 mm²) | 7 × 0.20 (7/32) | 0.15 / 0.15 PTFE | 1.3 × 2.2 | 8.9 |
| Tier 4 — Twisted-Shielded (TWSH Foil+Drain & Copper-Braided) Fluoropolymer Sensor Cables | |||||
| TBX-TWSH-PFA-20 | 20 AWG Twisted Pair | Solid (1 × 0.81) | PFA + Foil/Drain + PFA | 3.7 (Round) | 24.5 |
| TBX-TWSH-PFA-20S | 20S AWG Twisted Pair | 7 × 0.32 (7/28) | PFA + Foil/Drain + PFA | 3.8 (Round) | 25.2 |
| TBX-TWSH-PFA-24 | 24 AWG Twisted Pair | Solid (1 × 0.51) | PFA + Foil/Drain + PFA | 2.7 (Round) | 14.8 |
| TBX-TWSH-PFA-24S | 24S AWG Twisted Pair | 7 × 0.20 (7/32) | PFA + Foil/Drain + PFA | 2.9 (Round) | 15.6 |
| TBX-TWSH-FEP-24S | 24S AWG Twisted Pair | 7 × 0.20 (7/32) | FEP + Foil/Drain + FEP | 2.9 (Round) | 15.2 |
| TBX-TC-FEPC-022 | 2 × 0.22 mm² (~24S) | 7 × 0.20 Twisted | FEP + TC Braid + FEP | 2.6 (Round) | 18.5 |
Selection guide: Choose extruded PFA (-200/+260°C) for pressurized autoclaves, vacuum bagging, and semiconductor cleanrooms; extruded FEP (-90/+200°C) for lyophilizers and steam retorts; sintered PTFE for high clamp loads; and TWSH or braided builds near VFDs and SCR furnaces.
Ordering & Quotation Checklist: Specify calibration type (K, J, T, E, or N), tolerance class (IEC Class 1 / ASTM SLE or Standard), color code (IEC 60584-3 or ANSI MC96.1), AWG/stranding (40 AWG to 20 AWG), fluoropolymer (PFA, FEP, PTFE, or TWSH), and total length (MOQ 50 m; 7–45 working days).
Thermocouple Extension & Compensating Cable (Type KX, JX, TX, EX, NX)
KX, JX, TX, EX, NX (Extension) & KCA, KCB, VX, BX (Compensating)
IEC 60751 Screened FEP, PFA & PTFE Pt100 / Pt1000 RTD Cable
IEC 60751 / EN 60751 Pt100, Pt500 & Pt1000 (Cl. AA, A, B)
DEF STAN 61-12 Part 4, Part 5 & Part 6 Control & Equipment Cable
Part 4 (7/0.2 mm) | Part 5 (16/0.2 mm) | Part 6 (BS 4808 Wire)
Request Quotation & Datasheet for This Cable
Need factory pricing, cross-section drawing or a full PDF datasheet for Duplex FEP, PFA & Sintered PTFE Thermocouple Sensor Wire? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.
- ISO 9001 Factory Direct
- MOQ 50 m (Custom Builds)
- 24h Engineering Reply