LSZH-Jacket Shielded VFD Motor Cable
Screened industrial drive-to-motor routes where a low-smoke jacket is part of the project specification, including indoor equipment spaces and suitable fixed outdoor routes. Selected TC / WTTC / motor-supply rating: 1000 V Dry / wet rating: 90°C / 90°C Operating temperature: −25 to +90°C Nominal outside diameter: 17.5 mm Minimum stationary / installation radius: 210 mm / 210 mm
- Selected TC / WTTC / motor-supply rating1000 V
- Dry / wet rating90°C / 90°C
- Operating temperature−25 to +90°C
- Nominal outside diameter17.5 mm
- Minimum stationary / installation radius210 mm / 210 mm
- Nominal capacitance85 pF/m core-to-core; 150 pF/m core-to-other.
- Nominal phase DCR3.18 Ω/km
- Nominal weight527 kg/km
LSZH-Jacket Shielded VFD Motor Cable Drive & Motor Cable Identification
- Type: Industrial Cables
- Selected TC / WTTC / motor-supply rating: 1000 V
- Dry / wet rating: 90°C / 90°C
- Operating temperature: −25 to +90°C
PWM Inverter Voltage, Thermal & Bend Ratings
- Nominal outside diameter: 17.5 mm
- Minimum stationary / installation radius: 210 mm / 210 mm
- Nominal capacitance: 85 pF/m core-to-core; 150 pF/m core-to-other.
- Nominal phase DCR: 3.18 Ω/km
- Nominal weight: 527 kg/km
LSZH-Jacket Shielded VFD Motor Cable Low-Capacitance & Dual-Screen Build
- Phase group: 3 × 10 AWG, 105 × 30 tinned copper; black XLPE insulation.
- Protective conductor: 10 AWG tinned copper with green/yellow PVC insulation.
- Ground/drain: Separate bare tinned-copper element.
- Screen: 100% aluminum/polyester/aluminum foil and 85% tinned-copper braid.
- Outer jacket: Black LSZH flame-retardant material; nominal wall 1.9 mm.
Select the complete construction
The LSZH designation here describes the outer jacket. Keep the PVC protective-conductor insulation visible in the material schedule; a black jacket color cannot establish the composition of the inner layers.
Define the ordered acceptance conditions
Include the exact construction, applicable designations, dimensions and required inspections in the purchase specification. For motion, define the carrier or route geometry, temperature, speed, acceleration and cycle definition. For optical or RF links, include wavelengths or frequencies, interfaces, connections and the installed link acceptance criteria.
EMC Transfer Impedance & Bearing Current Control
- Select the complete construction: The LSZH designation here describes the outer jacket.
- Define the ordered acceptance conditions: Include the exact construction, applicable designations, dimensions and required inspections in the purchase specification.
- Route and equipment selection: For public facilities or enclosed equipment areas, specify the required smoke and gas tests alongside the installation classification.
- Separate the four fire-performance questions: Flame spread describes how a cable burns; smoke density describes visibility; acid-gas or halogen measurements describe combustion products; fire survival concerns continued circuit operation.
Industrial Oil, Vibration & Plant Routing Durability
- Installation & Routing: Screened industrial drive-to-motor routes where a low-smoke jacket is part of the project specification, including indoor equipment spaces and suitable fixed outdoor routes.
- Termination & Entry Check: Use each value for the stated construction and operating condition. Nominal dimensions refer to the representative configuration; select the full size and installation schedule before ordering.
- UL 1277 / UL 2277: Selected TC-ER, WTTC and motor-supply classifications.
- UL 1685, FT4 loading: Flame-test reference for this construction.
IEC / VDE / UL Variable-Frequency Drive Standards
- UL 1277 / UL 2277: Selected TC-ER, WTTC and motor-supply classifications.
- UL 1685, FT4 loading: Flame-test reference for this construction.
- ICEA S-95-658: Power/control cable reference.
- LSZH outer jacket: Material description; distinguish it from complete-cable halogen-free requirements.
VFD, Servo & EMC Earthing Guides

LSZH-Jacket Shielded VFD Motor Cable Inverter-Fed Motor & Drive Integration
LSZH-jacket shielded VFD motor cable uses tinned-copper phase conductors, XLPE phase insulation, an overall foil-and-braid screen and a low-smoke zero-halogen outer jacket. The representative 10 AWG build has three phase cores, a green/yellow PVC-insulated protective conductor and a separate tinned-copper ground/drain.
Jacket selection and complete-cable fire requirements are separate procurement decisions. Identify the materials of the phase insulation, protective conductor and outer jacket individually. This keeps a low-smoke jacket requirement distinct from a specification that requires every polymer in the complete cable to be halogen-free.
Typical Variable-Speed Drive Installations
- Screened industrial drive-to-motor routes where a low-smoke jacket is part of the project specification, including indoor equipment spaces and suitable fixed outdoor routes.
Route and equipment selection
For public facilities or enclosed equipment areas, specify the required smoke and gas tests alongside the installation classification. Select a separately defined fire-resistant cable when the circuit must continue operating during a fire.
Compare related cable duties
- 600/1000 V Foil-and-Braid Shielded VFD Motor Cable
- 2000 V TC-ER Shielded VFD Motor Cable
- NEK 606 BFOU VFD 1.8/3 kV Fire-Resistant LSZH Offshore VFD Power Cable
LSZH-Jacket Shielded VFD Motor Cable VFD Screening & Termination FAQ
Why is 'Select the complete construction' critical when specifying LSZH-Jacket Shielded VFD Motor Cable?
The LSZH designation here describes the outer jacket. Keep the PVC protective-conductor insulation visible in the material schedule; a black jacket color cannot establish the composition of the inner layers.
How should engineers address 'define the ordered acceptance conditions' for LSZH-Jacket Shielded VFD Motor Cable?
Include the exact construction, applicable designations, dimensions and required inspections in the purchase specification. For motion, define the carrier or route geometry, temperature, speed, acceleration and cycle definition. For optical or RF links, include wavelengths or frequencies, interfaces, connections and the installed link acceptance criteria.
What is the engineering rule regarding 'route and equipment selection' on LSZH-Jacket Shielded VFD Motor Cable?
For public facilities or enclosed equipment areas, specify the required smoke and gas tests alongside the installation classification. Select a separately defined fire-resistant cable when the circuit must continue operating during a fire.
Which conductor stranding, core identification, and jacket compounds are used in LSZH-Jacket Shielded VFD Motor Cable?
Phase group: 3 × 10 AWG, 105 × 30 tinned copper; black XLPE insulation.; Protective conductor: 10 AWG tinned copper with green/yellow PVC insulation.; Ground/drain: Separate bare tinned-copper element.; Screen: 100% aluminum/polyester/aluminum foil and 85% tinned-copper braid.; Outer jacket: Black LSZH flame-retardant material; nominal wall 1.9 mm.
Use each value for the stated construction and operating condition. Nominal dimensions refer to the representative configuration; select the full size and installation schedule before ordering.
TEBAOFLEX® — LSZH-Jacket Shielded VFD Motor Cable Construction, Operating & Compliance Matrix
| Cable Element / Layer | Selected Construction | Operating Parameter / Condition | Normative Reference & Test Scope |
|---|---|---|---|
| Phase group | 3 × 10 AWG, 105 × 30 tinned copper; black XLPE insulation. | Selected TC / WTTC / motor-supply rating: 1000 V | UL 1277 / UL 2277 — Selected TC-ER, WTTC and motor-supply classifications. |
| Protective conductor | 10 AWG tinned copper with green/yellow PVC insulation. | Dry / wet rating: 90°C / 90°C | UL 1685, FT4 loading — Flame-test reference for this construction. |
| Ground/drain | Separate bare tinned-copper element. | Operating temperature: −25 to +90°C | ICEA S-95-658 — Power/control cable reference. |
| Screen | 100% aluminum/polyester/aluminum foil and 85% tinned-copper braid. | Nominal outside diameter: 17.5 mm | LSZH outer jacket — Material description; distinguish it from complete-cable halogen-free requirements. |
| Outer jacket | Black LSZH flame-retardant material; nominal wall 1.9 mm. | Minimum stationary / installation radius: 210 mm / 210 mm | UL 1277 / UL 2277 — Selected TC-ER, WTTC and motor-supply classifications. |
TEBAOFLEX® — LSZH-Jacket Shielded VFD Motor Cable technical parameters
| Parameter | Value / condition |
|---|---|
| Selected TC / WTTC / motor-supply rating | 1000 V |
| Dry / wet rating | 90°C / 90°C |
| Operating temperature | −25 to +90°C |
| Nominal outside diameter | 17.5 mm |
| Minimum stationary / installation radius | 210 mm / 210 mm |
| Nominal capacitance | 85 pF/m core-to-core; 150 pF/m core-to-other. |
| Nominal phase DCR | 3.18 Ω/km |
| Nominal weight | 527 kg/km |
TEBAOFLEX® — LSZH-Jacket Shielded VFD Motor Cable configuration comparison
| Configuration | Selection scope |
|---|---|
| Low-smoke outer jacket | The representative construction on this page. |
| Complete halogen-free cable | Specify every polymer and the complete-cable acceptance tests. |
| Thermoset marine jacket | A distinct construction and approval scope. |
| Fire-resistant circuit cable | Select by the required fire-survival test, not smoke terminology. |
TEBAOFLEX® — Separate fire-performance requirements
| Property | Question answered |
|---|---|
| Flame spread | How does the cable propagate a specified flame exposure? |
| Smoke density | What smoke-test criterion is required? |
| Halogen / acid gas | Which combustion-gas test and limit apply? |
| Circuit integrity | Must the circuit remain functional during a specified fire? |
Separate the four fire-performance questions
Flame spread describes how a cable burns; smoke density describes visibility; acid-gas or halogen measurements describe combustion products; fire survival concerns continued circuit operation. Put each required test and its acceptance condition into the purchase specification. These properties are not interchangeable, and selecting a jacket alone does not define all four.
Selection guide: Send the circuit schedule, route drawing, connection details and required quantity with your inquiry. Our engineers can coordinate the selected cable construction, finished dimensions, installation conditions and delivery lengths with your equipment specification. Include required reel lengths, installation markings and inspection documents so the delivery schedule matches the project.
Ordering & Quotation Checklist: Send voltage marking, phase size, complete layer materials, jacket/fire requirements, route length and screen/ground terminations.
Request Quotation & Datasheet for This Cable
Need factory pricing, cross-section drawing or a full PDF datasheet for LSZH-Jacket Shielded VFD Motor Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.
- ISO 9001 Factory Direct
- MOQ 50 m (Custom Builds)
- 24h Engineering Reply