FHL2G Unscreened 1000V AC / 1500V DC Silicone EV High-Voltage Cable (ISO 6722)

FHL2G is an unscreened, ultra-flexible 1,000 V AC / 1,500 V DC high-voltage electric vehicle (EV) silicone cable engineered in accordance with ISO 6722, LV 216, and ISO 19642. In the VDE/ISO automotive nomenclature, FH denotes a high-voltage road vehicle.

  • Model DesignationFHL2G (Unscreened Fine-Stranded High-Voltage Silicone Road Vehicle Cable)
  • Rated Voltage1,000 V AC / 1,500 V DC (600 V / 900 V Core-to-Earth)
  • Test Voltage10 kV AC Spark Test / 5 kV AC Dielectric Withstand (5 Minutes)
  • Conductor Cross-Section0.50 mm² to 120 mm² Fine-Stranded Bare or Tinned Copper (DIN EN 60228 Class 5)
  • Insulation MaterialTear-Resistant Silicone Rubber (2G) — High-Voltage Orange (RAL 2003), Black, Red, or Blue
  • Operating Temperature-40°C to +180°C (up to +200°C Short-Term Overload, ISO 6722 Class E / F)
  • Minimum Bending Radius3 × to 5 × Overall Cable Diameter (Ultra-Flexible Tight Battery Pack Routing)
  • Supply FormatCustom Cut Lengths, Export Wooden Drums, and OEM Harnessing
Category:

FHL2G Unscreened 1000V AC / 1500V DC E-Mobility & Traction Specification

  • Type: EV High-Voltage & Charging Cables
  • Model Designation: FHL2G (Unscreened Fine-Stranded High-Voltage Silicone Road Vehicle Cable
  • Rated Voltage: 1,000 V AC / 1,500 V DC (600 V / 900 V Core-to-Earth
  • Test Voltage: 10 kV AC Spark Test / 5 kV AC Dielectric Withstand (5 Minutes

DC/AC High-Voltage & Thermal Class Ratings

  • Conductor Cross-Section: 0.50 mm² to 120 mm² Fine-Stranded Bare or Tinned Copper (DIN EN 60228 Class 5
  • Insulation Material: Tear-Resistant Silicone Rubber (2G) — High-Voltage Orange (RAL 2003), Black, Red, or Blue
  • Operating Temperature: -40°C to +180°C (up to +200°C Short-Term Overload, ISO 6722 Class E / F
  • Minimum Bending Radius: 3 × to 5 × Overall Cable Diameter (Ultra-Flexible Tight Battery Pack Routing
  • Supply Format: Custom Cut Lengths, Export Wooden Drums, and OEM Harnessing

FHL2G Unscreened 1000V AC / 1500V DC Fine-Stranded & EMC-Screened Build

FHL2G combines high-purity oxygen-free fine copper stranding with a tear-resistant, single-extrusion or co-extruded high-voltage silicone elastomer wall.

  • Conductor: Fine-stranded bare copper or tinned copper according to DIN EN 60228 Class 5 (optional Class 6 extra-flexible rope lay on 25–120 mm²).
  • Separator Film: Optional polyester release tape on >= 16 mm² sizes for clean high-speed automated stripping and ultrasonic welding.
  • Insulation: High-dielectric-strength, tear-resistant silicone rubber (2G) rated 1,000 V AC / 1,500 V DC (-40°C to +180°C).
  • Color Coding: Standard HV Orange (RAL 2003) for exterior high-voltage identification; Black, Red, or Blue for internal battery pack bus interconnects.

High-Voltage Dielectric & Flex Routing Performance

  • Voltage Rating: 1,000 V AC / 1,500 V DC
  • Size Schedule: 0.50 mm² to 120 mm² (Class 5 Cu
  • Insulation System: 2G Silicone Rubber (-40°C to +180°C
  • Standard Color: HV Orange (RAL 2003) / Red / Black

Battery Fluid, Thermal Shock & Ozone Endurance

  • True 1,000 V AC / 1,500 V DC High-Voltage Rating:: Engineered for 800 V and 1,000 V EV architectures with a 5 kV AC 5-minute dielectric withstand test and 10 kV spark test.
  • Extreme -40°C to +180°C Silicone Thermal Class:: Meets ISO 6722 Class E (+175°C) and Class F (+200°C) thermal aging requirements without halogen plasticizers.
  • Complete 0.50 mm² to 120 mm² Single-Core Range:: Covers both BMS cell-tap / HVIL sense leads (0.5–2.5 mm²), auxiliary PTC heater / e-compressor feeds (4–16 mm²), and main battery-to-inverter links (25–120 mm²).
  • Halogen-Free & Flame-Retardant per ISO 6722:: Self-extinguishing silicone compound passes ISO 6722 45-degree flame propagation testing with low smoke and zero corrosive halogens.

ISO 19642 / ISO 6722 / EN 50620 EV Standards

  • ISO 6722-1 Class E / Class F: Road vehicle single-core high-temperature silicone cable standard (-40°C to +180°C/+200°C).
  • ISO 19642-5 / LV 216: High-voltage 1,000 V AC / 1,500 V DC electric vehicle cable dimensions and dielectric testing.
  • DIN EN 60228 / IEC 60228 Class 5: Fine-stranded flexible bare or tinned copper conductors.
  • IEC 60754-1/2: Halogen-free and non-corrosive combustion gas compliance.

EV High-Voltage & Charging Cable Guides

High-voltage DC power distribution and battery inverter interconnection using orange FHL2G 1500V DC silicone EV cables
FHL2G unscreened 1,000 V AC / 1,500 V DC high-voltage silicone cables provide ultra-flexible -40°C to +180°C routing inside EV battery packs, PDU busbars, and enclosed metallic traction conduits. Photo: Arnold Reinhold, CC BY-SA 3.0.

FHL2G Unscreened 1000V AC / 1500V DC Traction Harness & Charging Architecture

FHL2G is an unscreened, ultra-flexible 1,000 V AC / 1,500 V DC high-voltage electric vehicle (EV) silicone cable engineered in accordance with ISO 6722, LV 216, and ISO 19642. In the VDE/ISO automotive nomenclature, FH denotes a high-voltage road vehicle conductor, L indicates fine-wire flexible stranding, and 2G specifies a heat-resistant silicone rubber insulation system rated for continuous service from -40°C to +180°C (+200°C peak).

Inside enclosed metal EV battery packs, battery disconnect units (BDUs), power distribution units (PDUs), and fuel-cell stacks—or when routed through outer corrugated metallic EMC conduits—individual braided cable shielding is unnecessary and adds unwanted stiffness and termination weight. FHL2G unscreened silicone cable allows tight 3×D to 5×D bending radii between lithium-ion cell modules, contactors, pyro-fuses, and HV service disconnects without exerting mechanical stress on bolted busbar terminals. We manufacture the complete FHL2G gauge schedule from 0.50 mm² and 0.75 mm² BMS voltage-sense leads up to 35 mm², 50 mm², 70 mm², 95 mm², and 120 mm² main battery traction interconnects in high-visibility RAL 2003 Orange (as well as Black, Red, and Blue for internal DC+/DC- polarity identification). For UL-recognized EV battery wire, see ourUL 3287 XLPE EV Battery WireandUL 3135 600V 200°C Silicone Hook-Up Wire, or check our1500V DC Energy Storage System (ESS) Battery Cable.

EV Battery Packs, Inverters & Charging Stations

  • As electric passenger cars, commercial e-trucks, and heavy off-highway machinery transition from 400 V to 800 V–1,000 V silicon-carbide (SiC) architectures, internal battery pack wiring must withstand 1,500 V DC continuous working voltage and +180°C thermal spikes during fast DC supercharging.
  • Because silicone rubber (2G) maintains a constant low elastic modulus from -40°C to +180°C, FHL2G installs effortlessly in automated battery module assembly cells and absorbs road vibration between the chassis and e-axle components.

FHL2G Unscreened 1000V AC / 1500V DC Automotive & EV Engineering FAQ

What is the difference between FHL2G and FHLR2GCB2G?

FHL2G is the unscreened single-insulated high-voltage silicone wire used inside shielded metallic battery enclosures, PDUs, or EMC conduits. FHLR2GCB2G adds an aluminum-mylar foil screen, a tinned copper braid shield (CB), and an outer silicone jacket (2G) for exposed under-body EV routing.

Can FHL2G be used in 800 V and 1,000 V electric vehicle battery packs?

Yes. FHL2G is rated for 1,000 V AC and 1,500 V DC continuous working voltage and undergoes a 5 kV AC 5-minute dielectric withstand test and a 10 kV spark test, providing full safety margin for 800 V and 1,000 V EV battery architectures.

Should I specify bare copper or tinned copper for FHL2G?

Both are supported in Datasheet #116. Bare copper offers slightly lower DC resistance and is widely used with ultrasonic welding and standard closed-barrel compression lugs. Tinned copper is preferred in high-humidity marine/bus applications or where silver/tin-plated terminals are specified.

Why is FHL2G preferred over XLPE (FHLR91X) inside battery module interconnects?

Cross-linked polyethylene (XLPE) is relatively stiff in large cross-sections (35 mm2 to 120 mm2), transferring mechanical torque onto battery module M8/M10 busbar studs. Silicone (FHL2G) is ultra-limp down to -40°C, allowing 3×D bends inside compact battery trays without stressing cell terminals.

Complete conductor stranding, resistance, insulation thickness, and outer diameter specifications below are extracted directly from TEBAOFLEX engineering datasheet #116 (FHL2G 1000V AC / 1500V DC).

TEBAOFLEX® — FHL2G 1000V AC / 1500V DC Silicone EV Cable — Small & Auxiliary Gauges (0.50 mm² to 10 mm², Datasheet #116)

FHL2G 1000V AC / 1500V DC Silicone EV Cable — Small & Auxiliary Gauges (0.50 mm² to 10 mm², Datasheet #116)
Nominal Cross-Section Max. Strand Dia. (mm) Max. Conductor Dia. (mm) Max. DCR @ 20°C (Bare / Tinned Ω/km) Min. Insulation Wall (mm) Nominal Outer Dia. (mm) Approx. Weight (kg/km)
1 × 0.50 mm² 0.21 mm 1.0 mm 37.1 / 38.2 Ω/km 0.64 mm 2.30 ± 0.10 mm 10 kg/km
1 × 0.75 mm² 0.21 mm 1.2 mm 24.7 / 25.4 Ω/km 0.64 mm 2.50 ± 0.10 mm 13 kg/km
1 × 1.00 mm² 0.21 mm 1.35 mm 18.5 / 19.1 Ω/km 0.64 mm 2.70 ± 0.10 mm 16 kg/km
1 × 1.50 mm² 0.26 mm 1.70 mm 12.7 / 13.0 Ω/km 0.64 mm 3.00 ± 0.10 mm 21 kg/km
1 × 2.50 mm² 0.26 mm 2.20 mm 7.60 / 7.82 Ω/km 0.72 mm 3.60 ± 0.10 mm 33 kg/km
1 × 4.00 mm² 0.31 mm 2.75 mm 4.71 / 4.85 Ω/km 0.72 mm 4.20 ± 0.10 mm 48 kg/km
1 × 6.00 mm² 0.31 mm 3.30 mm 3.14 / 3.23 Ω/km 0.72 mm 5.00 ± 0.20 mm 69 kg/km
1 × 10.0 mm² 0.41 mm 4.50 mm 1.82 / 1.85 Ω/km 0.96 mm 6.50 ± 0.20 mm 117 kg/km

TEBAOFLEX® — FHL2G 1000V AC / 1500V DC Silicone EV Cable — Traction Power Gauges (16 mm² to 120 mm², Datasheet #116)

FHL2G 1000V AC / 1500V DC Silicone EV Cable — Traction Power Gauges (16 mm² to 120 mm², Datasheet #116)
Nominal Cross-Section Max. Strand Dia. (mm) Max. Conductor Dia. (mm) Max. DCR @ 20°C (Bare / Tinned Ω/km) Min. Insulation Wall (mm) Nominal Outer Dia. (mm) Approx. Weight (kg/km)
1 × 16.0 mm² 0.41 mm 5.80 mm 1.16 / 1.18 Ω/km 0.96 mm 8.20 ± 0.20 mm 182 kg/km
1 × 25.0 mm² 0.41 mm 7.20 mm 0.743 / 0.757 Ω/km 1.04 mm 9.60 ± 0.20 mm 270 kg/km
1 × 35.0 mm² 0.41 mm 8.50 mm 0.527 / 0.538 Ω/km 1.04 mm 11.50 ± 0.30 mm 380 kg/km
1 × 50.0 mm² 0.41 mm 10.50 mm 0.368 / 0.375 Ω/km 1.20 mm 13.50 ± 0.30 mm 535 kg/km
1 × 70.0 mm² 0.51 mm 12.50 mm 0.259 / 0.264 Ω/km 1.20 mm 15.50 ± 0.30 mm 735 kg/km
1 × 95.0 mm² 0.51 mm 14.80 mm 0.196 / 0.200 Ω/km 1.44 mm 18.00 ± 0.40 mm 990 kg/km
1 × 120.0 mm² 0.51 mm 16.50 mm 0.153 / 0.156 Ω/km 1.44 mm 20.20 ± 0.40 mm 1,240 kg/km

Selection guide: Both bare copper (blank) and tinned copper (verzinkt/tinned) conductors are available across all 15 sizes from 0.50 mm² to 120 mm². For water-blocked low-voltage sensor harnesses and high-voltage EV traction leads, compare180B ISO Class D / GXL-WB / TXL-WB anti-capillary automotive wire,HLR2GCB2G shielded silicone automotive powertrain cable, and ourAC vs DC EV charging cable guide.

Ordering & Quotation Checklist: Specify your required FHL2G cross-section (0.50 mm2 to 120 mm2), conductor finish (bare or tinned copper), insulation color (RAL 2003 Orange, Red, or Black), and reel length for an immediate EV quotation.

Direct Factory Engineering RFQ

Request Quotation & Datasheet for This Cable

Need factory pricing, cross-section drawing or a full PDF datasheet for FHL2G Unscreened 1000V AC / 1500V DC Silicone EV High-Voltage Cable (ISO 6722)? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.

  • ISO 9001 Factory Direct
  • MOQ 50 m (Custom Builds)
  • 24h Engineering Reply
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    FHL2G Unscreened 1000V AC / 1500V DC Silicone EV High-Voltage Cable (ISO 6722)Get A Quote