Product Categories

Heavy-duty rubber cables for mining, port cranes, submersible pumps, EV charging, elevators and marine duty. Pick a family to filter the range.

TEBAOFLEX Flexible PVC Control & Low-Frequency Data Cables 3D Stepped Cutaway Cable
DIN VDE 0285 · VDE 0812 · UL/CSA AWM · MACHINERY & AUTOMATION

Flexible PVC Control & Low-Frequency Data Cables

Comprehensive European and UL/CSA industrial automation cables including YSLY-JZ/OZ, Ölflex-equivalent CY/SY screened control cables, LiYY / LiYCY DIN 47100 data transmission cables and drag-chain control series across 2 to 61 cores.

VOLTAGE RATING
300/500V – 0.6/1kV
CORE CONFIGS
2 to 61 Cores
CORE STANDARDS
VDE 0285 · UL
MODELS IN STOCK
106 Verified Specs
Spec Filters 106 Models
YSLY-JZ / OZ & H05VV5-F Numbered Control Cable Cross Section
300/500 V · VDE 0285
YSLY-JZ / OZ & H05VV5-F Numbered Control Cable
YSLY-CY / Ölflex-110-CY Screened Control Cross Section
EMC Copper Braid · CY
YSLY-CY / Ölflex-110-CY Screened Control
LiYY, LiYCY & LiYCY-TP Twisted-Pair Data Cable Cross Section
DIN 47100 · Data & Signal
LiYY, LiYCY & LiYCY-TP Twisted-Pair Data Cable
YSLY-SY Mechanical-Protected Machine Cable Cross Section
Galvanized Steel Braid · SY
YSLY-SY Mechanical-Protected Machine Cable

Flexible PVC Control & Low-Frequency Data Cables — Engineering Selection & Custom Manufacturing

Comprehensive European and UL/CSA industrial automation cables including YSLY-JZ/OZ, Ölflex-equivalent CY/SY screened control cables, LiYY / LiYCY DIN 47100 data transmission cables and drag-chain control series across 2 to 61 cores.

VOLTAGE RATING300/500V – 0.6/1kV
CORE CONFIGS2 to 61 Cores
CORE STANDARDSVDE 0285 · UL
MODELS IN STOCK106 Verified Specs
  • LiYY Cable: Unscreened PVC Data and Control Cable, 0.14 to 0.75 mm²

    LiYY Cable: Unscreened PVC Data and Control Cable, 0.14 to 0.75 mm²

  • Micromodule, FTTH MDU, 5G FTTA Hybrid & Subsea/Arctic Optical Cable

    Micromodule, FTTH MDU, 5G FTTA Hybrid & Subsea/Arctic Optical Cable

  • N2XH, N2XCH & (N)HXH FE180/E30–E90 Halogen-Free Fire-Resistant Cable (0.6/1 kV)

    N2XH, N2XCH & (N)HXH FE180/E30–E90 Halogen-Free Fire-Resistant Cable (0.6/1 kV)

  • OPGW, OPPC & ADSS Overhead Transmission Optical Cable

    OPGW, OPPC & ADSS Overhead Transmission Optical Cable

  • Powerlex PVC Flexible Cord & Instrolex Screened Instrumentation Cable (AS/NZS)

    Powerlex PVC Flexible Cord & Instrolex Screened Instrumentation Cable (AS/NZS)

  • PROFIBUS DP & PA Fieldbus Cable: 150 Ω Type A & 100 Ω Process Bus Cable

    PROFIBUS DP & PA Fieldbus Cable: 150 Ω Type A & 100 Ω Process Bus Cable

  • PROFINET Type A / Type B / Type C Cat5e & Cat6A Industrial Ethernet Cable

    PROFINET Type A / Type B / Type C Cat5e & Cat6A Industrial Ethernet Cable

  • Railway Trackside Signalling, Axle Counter & Traction Feeder Cable

    Railway Trackside Signalling, Axle Counter & Traction Feeder Cable

  • RG16H1R12 & RG16H1(O)R12 1.8/3–26/45 kV MV HEPR G16 Power Cable

    RG16H1R12 & RG16H1(O)R12 1.8/3–26/45 kV MV HEPR G16 Power Cable

  • RG26H1M16 18/30 kV 105°C HEPR G26 LSZH Medium-Voltage Cable (CPR Cca)

    RG26H1M16 18/30 kV 105°C HEPR G26 LSZH Medium-Voltage Cable (CPR Cca)

  • RG7H1M1 6/10–18/30 kV (90°C & 105°C HEPR) LSZH MV Power Cable

    RG7H1M1 6/10–18/30 kV (90°C & 105°C HEPR) LSZH MV Power Cable

  • RHZ1-OL, RHZ1-2OL, RHZ1 (S/AS) & RH5Z1 6/10–18/30 kV MV XLPE Power Cable

    RHZ1-OL, RHZ1-2OL, RHZ1 (S/AS) & RH5Z1 6/10–18/30 kV MV XLPE Power Cable

  • ROZ1-K (AS) EMC (0.6/1 & 1.8/3 kV), RC4Z1-K, Z1C4Z1-K & RC4V-K Screened Cable

    ROZ1-K (AS) EMC (0.6/1 & 1.8/3 kV), RC4Z1-K, Z1C4Z1-K & RC4V-K Screened Cable

  • RZ1-K (AS) 0.6/1 & 1.8/3 kV, SZ-K, Z1Z1-K & TXXI Flexible LSZH Power Cable

    RZ1-K (AS) 0.6/1 & 1.8/3 kV, SZ-K, Z1Z1-K & TXXI Flexible LSZH Power Cable

  • S 200 & S 200 C PUR Robot & Drag Chain Cable: 300/500V Class 6 TPE-E/PP (-30°C)

    S 200 & S 200 C PUR Robot & Drag Chain Cable: 300/500V Class 6 TPE-E/PP (-30°C)

  • S 368 C & S 369 C TP PUR Drag Chain Data Cable: Class 6 DIN 47100 Screened

    S 368 C & S 369 C TP PUR Drag Chain Data Cable: Class 6 DIN 47100 Screened

Product Advantages

What sets TEBAOFLEX PVC Control & Data Cable apart in service.

Six Complete Automation Families

Control, PUR drag-chain & servo, fieldbus & Industrial Ethernet, DIN 47100 / EN 50288-7 instrumentation, panel wire and 0.6/1 kV VFD/fire-safety cables from one manufacturer.

Class 5 & Class 6 Stranding

Class 5 flexible copper for cabinet, machine and fixed/occasional-flex routing; Class 6 extra-fine copper on EFK 300, S 200, S 368/369 C and SL 800/803 C for continuous drag chains.

EMC & PiMF Screening

Tinned copper braids (LiYCY, CY, YSLYCY-JZ, S 200 C, SL 801/803 C), copper-tape VSD screens (Varolex) and individual foil-screened pairs (PiMF on Li2YCY-P, JE-LiYCY, RE-2Y(St)Y).

PUR, Oil-Resistant & Steel-Braided Sheaths

TMPU/PUR sheaths for coolant, cutting oil and drag-chain abrasion; EN 50525-2-51 oil-resistant PVC (H05VV5-F, H05VVC4V5-K); galvanised steel wire braid (SY, YSLYSY) for swarf impact.

Controlled-Impedance Fieldbus & Ethernet

120 Ω RS-485, CAN Bus and DeviceNet, 150 Ω PROFIBUS DP, 100 Ω PROFIBUS PA and FOUNDATION Fieldbus H1, 110 Ω CC-Link, and 100 Ω PROFINET Type A/B/C Cat5e and Cat6A.

LSZH & FE180/E30–E90 Fire Safety

Halogen-free LiHCH/LiHH, H05Z-K/H07Z-K, J-H(St)H, RE-2X(St)H, N2XH/N2XCH and DIN 4102-12 E30–E90 circuit-integrity (N)HXH FE180 plus Digital LHD fire sensing cables.

Control, Fieldbus, Drag-Chain & Instrumentation Range

Sixteen core product series across the 44-product category; click any series to view its full dimensional and electrical tables.

Model / SeriesSub-FamilyVoltage / ImpedanceConductor & InsulationScreen / Protection & Sheath
YY / YSLY-JZ & YSLY-OZFlexible PVC Control300/500 VClass 5 Cu, TI2 PVC cores, numbered + G/Y or OZUnscreened, TM2 grey PVC sheath (-40 °C fixed / +70 °C)
CY / YSLYCY-JZEMC Screened PVC Control300/500 VClass 5 Cu, PVC cores, PET tape + tinned Cu braidEMC braid screen, grey or transparent PVC sheath
SY / YSLYSYSteel-Wire-Braided Control300/500 VClass 5 Cu, PVC inner sheath + GSWB armourGalvanised steel wire braid, transparent PVC outer sheath
H05VV5-F & H05VVC4V5-KEN 50525-2-51 Oil-Resistant Control300/500 VClass 5 Cu, PVC cores; unscreened or tinned Cu braid (C4)Oil-resistant TM5 PVC sheath for machine tools
JZ-500 PUR & JZ-600 PUROil- & Abrasion-Resistant PUR Control300/500 V & 0.6/1 kVClass 5 Cu, PVC/TI2 cores, numbered + G/YTMPU polyurethane sheath (-40 °C to +80 °C, UV/oil resistant)
EFK 300 P/CP, S 200 C & JZ-602 RC-PURContinuous-Flex Drag-Chain Control300/500 V & 600 VClass 6 extra-fine Cu, TPE/PP/PVC coresUnscreened or tinned Cu braid, low-adhesion PUR jacket
SL 800/801/803 C & FD 30810 CPComposite PUR Servo & Encoder Drag Chain0.6/1 kV (Power) + 300 VClass 6 Cu, PP/TPE low-capacitance power + brake pairsScreened brake/control pairs + ≥85 % overall tinned Cu braid, PUR
H05BQ-F / H07BQ-F DuosheathEPR/PUR Heavy-Duty Trailing & Worksite300/500 V & 450/750 VClass 5 Cu, EI6 EPR rubber coresTMPU orange/yellow/black PUR sheath (-40 °C to +90 °C)
LiYY, LiYCY & LiHCH / LiHHDIN 47100 Electronic Data & Signal250–500 V peakFine-stranded Cu (0.14–1.5 mm²), PVC or LSZH coresUnscreened or tinned Cu braid; PVC or halogen-free LSZH sheath
Li2YCY / Li2YCY-P (PiMF)Low-Capacitance PE Twisted-Pair Data250 V / 300 VStranded Cu, low-cap PE pairs (0.14–1.0 mm²)Overall tinned Cu braid (+ PiMF pair foil on Li2YCY-P)
120 Ω RS-485, CAN Bus & DeviceNet120 Ω Serial Fieldbus300 VTwisted pairs, foam-skin PE, 120 Ω impedanceAl/PET foil + tinned Cu drain wire + tinned Cu braid; PVC/PUR/LSZH
PROFIBUS DP/PA, FF H1, CC-Link & AS-iProcess & Factory Fieldbus150 Ω / 100 Ω / 110 ΩSolid or stranded Cu (Type A/B/drag-chain), PE/foam-PEFoil + braid screening (DP/PA/FF H1/CC-Link); AS-i flat profile
PROFINET Type A / B / C Cat5e & Cat6A100 Ω Industrial Ethernet100 Ω (Cat5e / Cat6A)1/7/19-wire Cu, Star-Quad (Cat5e) or 4-pair (Cat6A)SF/UTP or S/FTP foil + tinned Cu braid, green PVC/PUR/LSZH
J-Y(St)Y, JE-Y(St)Y & EN 50288-7 RE-2Y(St)YVDE 0815 & EN 50288-7 Instrumentation300 V / 500 VPairs/triads in PVC, PE (2Y) or XLPE (2X), 0.5–2.5 mm²Collective (St) Al/PET foil or PiMF + drain wire, PVC or LSZH
H05V-K / H07V-K, H05Z-K / H07Z-K & KIVHarmonised Panel & Switchboard Wire300/500 V to 0.6/1 kVClass 5 flexible Cu, 0.5–240 mm² single-coreTI1 PVC (70 °C), EI5/LSZH (90 °C H07Z-K) or 125 °C 21X-LS0H
Varolex VSD, FG16(O)R16 & (N)HXH FE1800.6/1 kV VFD, HEPR & Fire-Resistant Power0.6/1 kVXLPE, G16 HEPR or mica-tape + XLPE (FE180 E30–E90)Cu tape screen (Varolex), concentric Cu (N2XCH), LSZH sheath

How to Choose PVC Control & Data Cable

Four decisions specify the right cable the first time; send them with your RFQ and our engineers confirm the type designation.

1

Circuit Function & Voltage

250–500 V peak for DIN 47100 signal/data (LiYY, LiYCY, Li2YCY) and EN 50288-7 instrumentation; 300/500 V or 450/750 V for control and panel wire; 0.6/1 kV for JZ-600 PUR, servo, VFD and power.

2

Static vs Drag-Chain Motion

Fixed or occasional flexing uses Class 5 PVC/LSZH (YY, YSLY-JZ, LiYCY, H07VV-F). Continuous power chains require Class 6 TPE/PP/EPR cores and a PUR jacket (EFK 300, S 200, SL 800/803 C).

3

EMC Screen, PiMF or Steel Braid

Overall tinned copper braid (LiYCY, CY, YSLYCY-JZ, H05VVC4V5-K) for drive interference; PiMF individual pair screens (Li2YCY-P, RE-2Y(St)Y) for crosstalk; GSWB (SY, YSLYSY) for mechanical protection.

4

Oil, LSZH & Fire Performance

Choose EN 50525-2-51 oil-resistant PVC (H05VV5-F) or PUR (JZ-500 PUR, H07BQ-F) for machine oils; LSZH (LiHCH, H07Z-K, N2XH) for low smoke; (N)HXH FE180 for E30–E90 circuit integrity.

Standards & Certifications

ISO 9001 quality management for cable production; ISO 14001 and ISO 45001 for sales and related management. UL and cUL (flexible cord), VDE (EN 50525-2-21), Korea KC, China MA and US MSHA approvals cover the certified types; CE is a third-party verification of conformity (VoC).

ISO 9001ISO 14001ISO 45001ULcULVDEKC (KTL)MAMSHACE VoC
UL Certificate of Compliance UL-US-2449012-4
UL Certification
VDE Marks Approval 40060056
VDE Certification
Korea KTL KC safety certification SU01346-25005
Korea KTL Certification
ISO 9001:2015 quality management system certificate 244-24-QI-17425-R0-S
ISO 9001 Quality Management

Manufacturing Process

From compound to shipment, the production steps and routine tests behind each cable length.

  1. 1

    Compound preparation

    EPR, CPE, PUR and silicone compounds are mixed and tested for hardness, tensile strength and elongation before use.

  2. 2

    Conductor stranding

    Tinned or bare copper is bunched and rope-stranded to Class 5/6 flexibility for trailing and reeling duty.

  3. 3

    Insulation extrusion

    Cores are extruded and continuously vulcanised; wall thickness and spark tests are recorded on every length.

  4. 4

    Core assembly and screening

    Cores, earth conductors, pilot and fibre-optic elements are laid up with the fillers and screens the type designation requires.

  5. 5

    Inner and outer sheathing

    Reinforced double-sheath constructions are extruded and cured for abrasion, oil and tear resistance.

  6. 6

    Routine electrical tests

    Conductor resistance, voltage withstand and insulation resistance tests at the levels set by the referenced standard.

  7. 7

    Mechanical and ageing tests

    Bending, tensile, hot-set, ozone and flame tests according to the referenced standard.

  8. 8

    Marking, packing and shipment

    Metre marking, drum packing and documentation for worldwide project delivery.

Construction, Layer by Layer

How TEBAOFLEX control, drag-chain, fieldbus and instrumentation cables are built from the conductor outward. For a step-by-step specification check, see how to read PVC insulation and sheath on a control-cable datasheet.

  1. 1

    Conductor & Stranding Class

    IEC 60228 Class 5 flexible copper for cabinet, machine and fixed/occasional-flex cables; Class 6 extra-fine copper on continuous drag-chain series (EFK 300, S 200, S 368/369 C, SL 800/803 C); solid or 7/19-strand copper on VDE 0815, EN 50288-7 and fieldbus cables.

  2. 2

    Core Insulation & Impedance Control

    PVC TI2 on standard control cables; low-capacitance PE, foam-skin PE or PP/TPE-E on RS-485, PROFIBUS, PROFINET, Li2YCY, RE-2Y(St)Y and servo motor cables; EI6 EPR on H05BQ-F/H07BQ-F; XLPE + mica tape on (N)HXH FE180.

  3. 3

    Core & Pair Identification

    DIN 47100 colour code on data cables (LiYY, LiYCY, LiHCH, Li2YCY, S 368/369 C); black numbered cores with or without green/yellow earth (JZ/OZ) on control cables; colour-coded or numbered twisted pairs/triads on fieldbus and instrumentation.

  4. 4

    Lay-Up & Drag-Chain Geometry

    Concentric layer stranding for fixed/flexible control cables; short-pitch bundle stranding around low-friction central fillers on high-speed drag-chain and robot cables (S 200, SL 800/803 C, FD 30810 CP).

  5. 5

    EMC Screening & Mechanical Braid

    Collective Al/PET foil with tinned drain wire (J-Y(St)Y, RE-2Y(St)Y); individual pair foil screens (PiMF on Li2YCY-P, JE-LiYCY, RE-2Y(St)Y PiMF); ≥80–85 % tinned copper braid (LiYCY, CY, YSLYCY-JZ, S 200 C); or galvanised steel wire braid (SY, YSLYSY). Use the LiYY vs LiYCY screening decision checklist when specifying signal shields.

  6. 6

    Outer Sheath Compound

    PVC TM2/TM5 (oil-resistant EN 50525-2-51 on H05VV5-F / H05VVC4V5-K), TMPU polyurethane (JZ-500/600 PUR, H07BQ-F, drag-chain series) for oil, coolant and abrasion, or halogen-free LSZH (LiHCH, H07Z-K, J-H(St)H, N2XH, (N)HXH FE180).

Cable Manufacturing Quality Control

Five-stage quality assurance from incoming copper to the packed drum.

  1. 01

    Raw Material Inspection

    Every batch of copper rod, rubber compound and reinforcing material is checked before it reaches the line.

    • Copper: conductor resistance, elongation and surface condition on incoming rod and drawn wire
    • EPR, CPE, PUR and silicone compounds: hardness, tensile strength, elongation and ageing samples from each mix
    ISO 9001IEC 60228
  2. 02

    Manufacturing Process Control

    Stranding, insulation extrusion, core assembly and sheathing run under recorded process parameters.

    • Class 5/6 stranding with lay length and tension monitored for trailing and reeling flexibility
    • Continuous-vulcanisation extrusion with wall thickness and spark tests logged on every length
    • Operators sign off each stage before the cable moves to the next machine
    ISO 9001Recorded parameters
  3. 03

    Electrical Testing

    Finished lengths go through the routine tests required by the referenced VDE, ICEA, IEC or NEK standard.

    • Conductor resistance and insulation resistance on every length
    • Voltage withstand test at the level set by the referenced standard
    • Screen and pilot-core continuity checks for mining and reeling constructions
    IEC 60502VDE 0250ICEA S-75-381
  4. 04

    Mechanical and Ageing Tests

    Samples from production are tested for the duty a mining, crane or submersible cable will actually see.

    • Tensile strength and elongation of insulation and sheath before and after ageing
    • Hot-set, ozone, oil-immersion and low-temperature bending tests
    • Constant-temperature water bath for insulation resistance of submersible constructions
    Hot-setOzoneOil immersionLow-temperature bending
  5. 05

    Flame Test and Final Inspection

    Before packing, the cable is checked against the order and the flame-performance requirement of its standard.

    • Single-cable vertical flame test to IEC 60332-1-2 where specified
    • Metre marking, printing, drum length and appearance inspection
    • Packing list with every shipment; test documents for the order confirmed at quotation
    IEC 60332-1-2Final inspection

Factory & Workshop Gallery

TEBAOFLEX CABLE, No.77 Wusongbang Road, Taicang, Suzhou.

Frequently Asked Questions

Quick answers about PVC Control & Data Cable from our engineers.

01How do I choose between PVC control cables (YY, YSLY-JZ, CY, SY) and PUR control or drag-chain cables?

Use flexible PVC control cables (YY, YSLY-JZ, CY, YSLYCY-JZ, SY, YSLYSY) for fixed indoor routing and occasional free flexing without tensile stress. When the cable is exposed to cutting fluids, mineral oils, outdoor weather or continuous travel in an energy chain, select oil-resistant PVC (H05VV5-F / H05VVC4V5-K) or polyurethane (JZ-500 PUR, JZ-600 PUR, JZ-602 RC-PUR, EFK 300 P/CP, S 200 / S 200 C).

02What is the difference between LiYY / LiYCY, Li2YCY-P and EN 50288-7 RE-2Y(St)Y / JE-Y(St)Y?

LiYY (unscreened) and LiYCY (overall tinned copper braid) use PVC insulation and DIN 47100 colour coding for short-to-medium signal and control runs. Li2YCY and Li2YCY-P (PiMF) use low-capacitance polyethylene (PE) insulation on twisted pairs for longer RS-422/RS-485 and analogue links. JE-Y(St)Y / JE-LiYCY (VDE 0815) and RE-2Y(St)Y / RE-2X(St)H (EN 50288-7) are process instrumentation cables built in pairs, triads or quads with collective or individual pair foil screens (PiMF) for 4–20 mA, HART and DCS/PLC cabinets.

03Which fieldbus or Industrial Ethernet cable matches my protocol?

Match the cable's characteristic impedance and geometry to the bus standard: 120 Ω shielded twisted pair for RS-485 Modbus RTU, CAN Bus (ISO 11898-2) and DeviceNet (Thick Trunk & Thin Drop); 150 Ω Type A for PROFIBUS DP and 100 Ω for PROFIBUS PA and FOUNDATION Fieldbus H1 (IEC 61158-2); 110 Ω 3-core shielded cable for CC-Link Ver.1.10/2.00; 2 × 1.5 mm² yellow/black profile cable for AS-Interface (AS-i); and 100 Ω PROFINET Type A (fixed), Type B (flexible) or Type C (drag-chain) Cat5e 4-wire / Cat6A 8-wire for Industrial Ethernet.

04Which cables are built for servo motors and VFD / VSD drives?

For continuous-flex drag chains on servo axes, choose SL 800 / SL 801 C (0.6/1 kV composite power + control pairs), SL 803 C / FD 30810 CP (low-capacitance motor power + brake pairs + feedback/encoder), or UL/CSA Servo 55700 / 60700 CY. For fixed or flexible 0.6/1 kV VSD/VFD motor feeders, Varolex uses a symmetrical 3-core + 3-split-earth XLPE layout with helical copper tape screening for low transfer impedance.

05When should I specify halogen-free (LSZH) or FE180 / E30–E90 fire-resistant cables?

Specify LSZH constructions—H05Z-K / H07Z-K and 21X-LS0H in panels, LiHCH / LiHH for data, J-H(St)H for building bus, RE-2X(St)H for instrumentation, FG16(O)M16 or N2XH / N2XCH for 0.6/1 kV power—in public buildings, tunnels, data centres and rail interiors where low smoke and zero halogen acid gas (IEC 60754 / IEC 61034) are mandatory. Where emergency lighting, smoke extractors or fire alarms must keep operating during a fire, specify (N)HXH FE180 E30–E90.

06What should I send for a quotation?

Send the cable designation or protocol, core or pair count and cross-section (mm² or AWG), voltage rating, screening type (unscreened, collective foil/braid, PiMF, GSWB), installation duty (fixed, occasional flex or drag-chain bend radius and travel speed), sheath compound (PVC, oil-resistant PVC, PUR, EPR/PUR or LSZH) and required cut/drum lengths.

Why Choose Us

A special-cable manufacturer in Taicang, Suzhou, making heavy-duty and special cables since 2014.

Certified Quality

UL and cUL, VDE, Korea KC, China MA and US MSHA approvals for the certified types, CE verification of conformity, and ISO 9001 quality management.

200+ Sets of Equipment

More than 200 sets of advanced production and test equipment at home and abroad, from compounding to final electrical testing.

15 Senior Cable Engineers

Constructions engineered to VDE, ICEA, IEC and NEK 606 standards and checked against the real duty cycle of your equipment.

1,500+ Cable Types

0.6/1 kV to 35 kV heavy-duty rubber cables, reeling and festoon crane cables, submersible, marine, ROV and high-temperature cables.

Custom Cable Design

Special constructions, fibre-optic elements, colours, printing and lengths built to the specification of your project.

Worldwide Project Supply

Cables working in tunnel engineering, marine and offshore equipment, mining, petrochemical, steel and urban construction projects around the world.

Can’t Find What You Need?

Send us the equipment, voltage, cores and operating conditions and our engineers will propose a cable construction and quotation.

Get A Quote