Product Categories
Heavy-duty rubber cables for mining, port cranes, submersible pumps, EV charging, elevators and marine duty. Pick a family to filter the range.
Flexible PVC Control & Low-Frequency Data Cables
Comprehensive European and UL/CSA industrial automation cables including YSLY-JZ/OZ, Ölflex-equivalent CY/SY screened control cables, LiYY / LiYCY DIN 47100 data transmission cables and drag-chain control series across 2 to 61 cores.




Flexible PVC Control & Low-Frequency Data Cables — Engineering Selection & Custom Manufacturing
Comprehensive European and UL/CSA industrial automation cables including YSLY-JZ/OZ, Ölflex-equivalent CY/SY screened control cables, LiYY / LiYCY DIN 47100 data transmission cables and drag-chain control series across 2 to 61 cores.
Showing 81–96 of 115 results
-

LiYY Cable: Unscreened PVC Data and Control Cable, 0.14 to 0.75 mm²
liyy cable: unscreened pvc data and control cable, 0.14 to 0.75 mm² liyy-cable & cable is an unscreened, pvc-insulated pvc-sheathed multicore for low-frequency signal wiring in instruments, electronic equipment panels. specify the core count conductor size within 014 075 liyycable liyycableunscreenedpvcdataandcontrolcable014to075mmliyycableliyy -

Micromodule, FTTH MDU, 5G FTTA Hybrid & Subsea/Arctic Optical Cable
micromodule, ftth mdu, 5g ftta hybrid & subsea/arctic optical cable micromodule-ftth-mdu-ftta-hybrid-extreme-cold-optical-cable pvc control data engineered to solve specialized access, wireless, multi-dwelling building, and harsh-environment deployment challenges, this four-in-one infrastructure portfolio encompasses: (1) 12f–2,160f finger-strippable micromodule cables (standard, mini, micro, 200 µm nano modules subseaarctic micromoduleftthmdufttahybridextremecoldopticalcable micromoduleftthmdu5gfttahybridsubseaarcticopticalcablemicromoduleftthmdufttahybridextremecoldopticalcable -

N2XH, N2XCH & (N)HXH FE180/E30–E90 Halogen-Free Fire-Resistant Cable (0.6/1 kV)
n2xh, n2xch & (n)hxh fe180/e30–e90 halogen-free fire-resistant cable (0.6/1 kv) n2xh-n2xch-nhxh-fe180-halogen-free-fire-resistant-cable pvc control data german din vde 0276-604 and 0266 0.6/1 kv safety power cables: n2xh-j/-o (xlpe/lszh), with concentric copper wire screen + counter-helix ('c'), / (n)hxch fe180 e30, e60, hxh nhxh fe180e30–e90 halogenfree fireresistant 061 n2xhn2xchnhxhfe180halogenfreefireresistantcable n2xhn2xchnhxhfe180e30e90halogenfreefireresistantcable061kvn2xhn2xchnhxhfe180halogenfreefireresistantcable n2xhn2xchhxhfe180e30e90halogenfreefireresistantcablen2xhn2xchnhxhfe180halogenfreefireresistantcable -

OPGW, OPPC & ADSS Overhead Transmission Optical Cable
opgw, oppc & adss overhead transmission optical cable opgw-oppc-adss-overhead-transmission-optical-cable pvc control data engineered for high-voltage electric utility towers, sub-transmission distribution poles, and electrified railway corridors, our opgw (optical ground wire), phase conductor) & (all-dielectric self-supporting) systems turn opgwoppcadssoverheadtransmissionopticalcable opgwoppcadssoverheadtransmissionopticalcableopgwoppcadssoverheadtransmissionopticalcable -

Powerlex PVC Flexible Cord & Instrolex Screened Instrumentation Cable (AS/NZS)
powerlex pvc flexible cord & instrolex screened instrumentation cable (as/nzs) powerlex-pvc-cord-instrolex-screened-instrumentation-cable control data cords (light duty 250/250 v, ordinary 250/440 v and heavy 0.6/1 kv per as/nzs 3191) cables (overall os individual & overall asnzs powerlexpvccordinstrolexscreenedinstrumentationcable powerlexpvcflexiblecordinstrolexscreenedinstrumentationcableasnzspowerlexpvccordinstrolexscreenedinstrumentationcable powerlexpvcflexiblecordinstrolexscreenedinstrumentationcablepowerlexpvccordinstrolexscreenedinstrumentationcable -

PROFIBUS DP & PA Fieldbus Cable: 150 Ω Type A & 100 Ω Process Bus Cable
profibus dp & pa fieldbus cable: 150 ω type a 100 process bus cable profibus-dp-pa-industrial-fieldbus-cable pvc control data wind power tebaoflex (150 iec 61158-2 a, 1×2×0.64 mm red/green foamed-pe pair with al-foil plus tinned copper braid under violet sheath) and (100 1×2×18 awg / profibusdppaindustrialfieldbuscable profibusdppafieldbuscable150typea100processbuscableprofibusdppaindustrialfieldbuscable -

PROFINET Type A / Type B / Type C Cat5e & Cat6A Industrial Ethernet Cable
profinet type a / b c cat5e & cat6a industrial ethernet cable profinet-type-a-b-c-cat5e-cat6a-industrial-ethernet-cable pvc control data wind power (solid conductor for fixed installation), (7-wire stranded flexible routing and occasional movement) (extra-fine continuous drag-chain, festoon robotic torsion profinettypeabccat5ecat6aindustrialethernetcable profinettypeatypebtypeccat5ecat6aindustrialethernetcableprofinettypeabccat5ecat6aindustrialethernetcable -

Railway Trackside Signalling, Axle Counter & Traction Feeder Cable
railway trackside signalling, axle counter & traction feeder cable railway-trackside-signalling-axle-counter-traction-feeder-cable pvc control data engineered for mainline high-speed rail corridors, metro tunnels, automated train (ertms/etcs level 2), and substations, our & portfolio covers the complete wayside railwaytracksidesignallingaxlecountertractionfeedercable railwaytracksidesignallingaxlecountertractionfeedercablerailwaytracksidesignallingaxlecountertractionfeedercable -

RG16H1R12 & RG16H1(O)R12 1.8/3–26/45 kV MV HEPR G16 Power Cable
rg16h1r12 & rg16h1(o)r12 1.8/3–26/45 kv mv hepr g16 power cable rg16h1r12-rg16h1or12-mv-hepr-power-cable pvc control data (single-core, also available in visible helical triplex rg16h1r12x) and rg16h1or12 (three-core cabled with inner filler) are medium- high-voltage cables rated from u0/u 1.8/3 through 3.6/6 kv, 6/10 183–2645 rg16h1r12rg16h1or12mvheprpowercable rg16h1r12rg16h1or121832645kvmvheprg16powercablerg16h1r12rg16h1or12mvheprpowercable rg16h1r12rg16h1r121832645kvmvheprg16powercablerg16h1r12rg16h1or12mvheprpowercable -

RG26H1M16 18/30 kV 105°C HEPR G26 LSZH Medium-Voltage Cable (CPR Cca)
rg26h1m16 18/30 kv 105°c hepr g26 lszh medium-voltage cable (cpr cca) rg26h1m16-18-30kv-105c-hepr-lszh-mv-cable pvc control & data is the highest fire-safety class power (en 50575 cpr euroclass cca-s1b,d1,a1) rated for u0/u 12/20 and (um 36 kv, 63 ac test voltage) in accordance 1830 mediumvoltage cca rg26h1m161830kv105cheprlszhmvcable rg26h1m161830kv105cheprg26lszhmediumvoltagecablecprccarg26h1m161830kv105cheprlszhmvcable rg26h1m161830kv105cheprg26lszhmediumvoltagecablerg26h1m161830kv105cheprlszhmvcable -

RG7H1M1 6/10–18/30 kV (90°C & 105°C HEPR) LSZH MV Power Cable
rg7h1m1 6/10–18/30 kv (90°c & 105°c hepr) lszh mv power cable rg7h1m1-mv-hepr-lszh-power-cable pvc control data (single-core, also available in visible triplex rg7h1m1x) is a halogen-free, low-smoke medium-voltage rated for u0/u 6/10 kv, 8.7/15 12/20 (um 24 kv), and 18/30 36 610–1830 90°c hepr rg7h1m1mvheprlszhpowercable rg7h1m16101830kv90c105cheprlszhmvpowercablerg7h1m1mvheprlszhpowercable -

RHZ1-OL, RHZ1-2OL, RHZ1 (S/AS) & RH5Z1 6/10–18/30 kV MV XLPE Power Cable
rhz1-ol, rhz1-2ol, rhz1 (s/as) & rh5z1 6/10–18/30 kv mv xlpe power cable rhz1-ol-2ol-al-cu-mv-xlpe-power-cable pvc control data (s), (as) and rh5z1-ol/2ol are 3.6/6 kv, 6/10 8.7/15 12/20 18/30 (um up to 36 kv) medium-voltage distribution cables engineered iec 60502-2, rhz1ol, rhz12ol, sas 610–1830 rhz1ol2olalcumvxlpepowercable rhz1olrhz12olrhz1sasrh5z16101830kvmvxlpepowercablerhz1ol2olalcumvxlpepowercable rhz1olrhz12olrhz1rh5z16101830kvmvxlpepowercablerhz1ol2olalcumvxlpepowercable -

ROZ1-K (AS) EMC (0.6/1 & 1.8/3 kV), RC4Z1-K, Z1C4Z1-K & RC4V-K Screened Cable
roz1-k (as) emc (0.6/1 & 1.8/3 kv), rc4z1-k, z1c4z1-k rc4v-k screened cable roz1-k-as-emc-rc4z1-k-z1c4z1-k-rc4v-k-screened-cable pvc control data 0.6/1 kv and (symmetrical 3+3 vfd motor cable), rc4z1-k (as), are european class 5 flexible emc-screened power, roz1k as 061 183 kv, rc4z1k, z1c4z1k rc4vk roz1kasemcrc4z1kz1c4z1krc4vkscreenedcable roz1kasemc061183kvrc4z1kz1c4z1krc4vkscreenedcableroz1kasemcrc4z1kz1c4z1krc4vkscreenedcable roz1kemc061183kvrc4z1kz1c4z1krc4vkscreenedcableroz1kasemcrc4z1kz1c4z1krc4vkscreenedcable -

RZ1-K (AS) 0.6/1 & 1.8/3 kV, SZ-K, Z1Z1-K & TXXI Flexible LSZH Power Cable
rz1-k (as) 0.6/1 & 1.8/3 kv, sz-k, z1z1-k txxi flexible lszh power cable rz1-k-as-06-1kv-18-3kv-flexible-xlpe-lszh-cable pvc control data kv and (une 21123-4 / iec 60502-1), together with extra-flexible sz-k (as), thermoplastic 211034) utility txxi, are european class 5 low-smoke zero-halogen rz1k as 061 183 szk, z1z1k rz1kas061kv183kvflexiblexlpelszhcable rz1kas061183kvszkz1z1ktxxiflexiblelszhpowercablerz1kas061kv183kvflexiblexlpelszhcable rz1k061183kvszkz1z1ktxxiflexiblelszhpowercablerz1kas061kv183kvflexiblexlpelszhcable -

S 200 & S 200 C PUR Robot & Drag Chain Cable: 300/500V Class 6 TPE-E/PP (-30°C)
s 200 & c pur robot drag chain cable: 300/500v class 6 tpe-e/pp (-30°c) s-200-s-200-c-pur-robot-drag-chain-cable pvc control data cable (unscreened) and (tinned-copper-braid emc-screened) are 300/500 v highly flexible halogen-free polyurethane (pur) drag-chain robotics cables built with din en 60228 extra-fine bare copper 300500v tpeepp 30°c s200s200cpurrobotdragchaincable s200s200cpurrobotdragchaincable300500vclass6tpeepp30cs200s200cpurrobotdragchaincable s200s200cpurrobotdragchaincable300500vclass6tpeepps200s200cpurrobotdragchaincable -

S 368 C & S 369 C TP PUR Drag Chain Data Cable: Class 6 DIN 47100 Screened
s 368 c & 369 tp pur drag chain data cable: class 6 din 47100 screened s-368-c-s-369-c-tp-pur-drag-chain-data-cable pvc control cable (multi-core) and (twisted-pair) are highly flexible tinned-copper-braid emc-screened polyurethane (pur) drag-chain measurement cables built with en 60228 extra-fine bare copper s368cs369ctppurdragchaindatacable s368cs369ctppurdragchaindatacableclass6din47100screeneds368cs369ctppurdragchaindatacable
Product Advantages
What sets TEBAOFLEX PVC Control & Data Cable apart in service.
Six Complete Automation Families
Control, PUR drag-chain & servo, fieldbus & Industrial Ethernet, DIN 47100 / EN 50288-7 instrumentation, panel wire and 0.6/1 kV VFD/fire-safety cables from one manufacturer.
Class 5 & Class 6 Stranding
Class 5 flexible copper for cabinet, machine and fixed/occasional-flex routing; Class 6 extra-fine copper on EFK 300, S 200, S 368/369 C and SL 800/803 C for continuous drag chains.
EMC & PiMF Screening
Tinned copper braids (LiYCY, CY, YSLYCY-JZ, S 200 C, SL 801/803 C), copper-tape VSD screens (Varolex) and individual foil-screened pairs (PiMF on Li2YCY-P, JE-LiYCY, RE-2Y(St)Y).
PUR, Oil-Resistant & Steel-Braided Sheaths
TMPU/PUR sheaths for coolant, cutting oil and drag-chain abrasion; EN 50525-2-51 oil-resistant PVC (H05VV5-F, H05VVC4V5-K); galvanised steel wire braid (SY, YSLYSY) for swarf impact.
Controlled-Impedance Fieldbus & Ethernet
120 Ω RS-485, CAN Bus and DeviceNet, 150 Ω PROFIBUS DP, 100 Ω PROFIBUS PA and FOUNDATION Fieldbus H1, 110 Ω CC-Link, and 100 Ω PROFINET Type A/B/C Cat5e and Cat6A.
LSZH & FE180/E30–E90 Fire Safety
Halogen-free LiHCH/LiHH, H05Z-K/H07Z-K, J-H(St)H, RE-2X(St)H, N2XH/N2XCH and DIN 4102-12 E30–E90 circuit-integrity (N)HXH FE180 plus Digital LHD fire sensing cables.
Control, Fieldbus, Drag-Chain & Instrumentation Range
Sixteen core product series across the 44-product category; click any series to view its full dimensional and electrical tables.
| Model / Series | Sub-Family | Voltage / Impedance | Conductor & Insulation | Screen / Protection & Sheath |
|---|---|---|---|---|
| YY / YSLY-JZ & YSLY-OZ | Flexible PVC Control | 300/500 V | Class 5 Cu, TI2 PVC cores, numbered + G/Y or OZ | Unscreened, TM2 grey PVC sheath (-40 °C fixed / +70 °C) |
| CY / YSLYCY-JZ | EMC Screened PVC Control | 300/500 V | Class 5 Cu, PVC cores, PET tape + tinned Cu braid | EMC braid screen, grey or transparent PVC sheath |
| SY / YSLYSY | Steel-Wire-Braided Control | 300/500 V | Class 5 Cu, PVC inner sheath + GSWB armour | Galvanised steel wire braid, transparent PVC outer sheath |
| H05VV5-F & H05VVC4V5-K | EN 50525-2-51 Oil-Resistant Control | 300/500 V | Class 5 Cu, PVC cores; unscreened or tinned Cu braid (C4) | Oil-resistant TM5 PVC sheath for machine tools |
| JZ-500 PUR & JZ-600 PUR | Oil- & Abrasion-Resistant PUR Control | 300/500 V & 0.6/1 kV | Class 5 Cu, PVC/TI2 cores, numbered + G/Y | TMPU polyurethane sheath (-40 °C to +80 °C, UV/oil resistant) |
| EFK 300 P/CP, S 200 C & JZ-602 RC-PUR | Continuous-Flex Drag-Chain Control | 300/500 V & 600 V | Class 6 extra-fine Cu, TPE/PP/PVC cores | Unscreened or tinned Cu braid, low-adhesion PUR jacket |
| SL 800/801/803 C & FD 30810 CP | Composite PUR Servo & Encoder Drag Chain | 0.6/1 kV (Power) + 300 V | Class 6 Cu, PP/TPE low-capacitance power + brake pairs | Screened brake/control pairs + ≥85 % overall tinned Cu braid, PUR |
| H05BQ-F / H07BQ-F Duosheath | EPR/PUR Heavy-Duty Trailing & Worksite | 300/500 V & 450/750 V | Class 5 Cu, EI6 EPR rubber cores | TMPU orange/yellow/black PUR sheath (-40 °C to +90 °C) |
| LiYY, LiYCY & LiHCH / LiHH | DIN 47100 Electronic Data & Signal | 250–500 V peak | Fine-stranded Cu (0.14–1.5 mm²), PVC or LSZH cores | Unscreened or tinned Cu braid; PVC or halogen-free LSZH sheath |
| Li2YCY / Li2YCY-P (PiMF) | Low-Capacitance PE Twisted-Pair Data | 250 V / 300 V | Stranded Cu, low-cap PE pairs (0.14–1.0 mm²) | Overall tinned Cu braid (+ PiMF pair foil on Li2YCY-P) |
| 120 Ω RS-485, CAN Bus & DeviceNet | 120 Ω Serial Fieldbus | 300 V | Twisted pairs, foam-skin PE, 120 Ω impedance | Al/PET foil + tinned Cu drain wire + tinned Cu braid; PVC/PUR/LSZH |
| PROFIBUS DP/PA, FF H1, CC-Link & AS-i | Process & Factory Fieldbus | 150 Ω / 100 Ω / 110 Ω | Solid or stranded Cu (Type A/B/drag-chain), PE/foam-PE | Foil + braid screening (DP/PA/FF H1/CC-Link); AS-i flat profile |
| PROFINET Type A / B / C Cat5e & Cat6A | 100 Ω Industrial Ethernet | 100 Ω (Cat5e / Cat6A) | 1/7/19-wire Cu, Star-Quad (Cat5e) or 4-pair (Cat6A) | SF/UTP or S/FTP foil + tinned Cu braid, green PVC/PUR/LSZH |
| J-Y(St)Y, JE-Y(St)Y & EN 50288-7 RE-2Y(St)Y | VDE 0815 & EN 50288-7 Instrumentation | 300 V / 500 V | Pairs/triads in PVC, PE (2Y) or XLPE (2X), 0.5–2.5 mm² | Collective (St) Al/PET foil or PiMF + drain wire, PVC or LSZH |
| H05V-K / H07V-K, H05Z-K / H07Z-K & KIV | Harmonised Panel & Switchboard Wire | 300/500 V to 0.6/1 kV | Class 5 flexible Cu, 0.5–240 mm² single-core | TI1 PVC (70 °C), EI5/LSZH (90 °C H07Z-K) or 125 °C 21X-LS0H |
| Varolex VSD, FG16(O)R16 & (N)HXH FE180 | 0.6/1 kV VFD, HEPR & Fire-Resistant Power | 0.6/1 kV | XLPE, G16 HEPR or mica-tape + XLPE (FE180 E30–E90) | Cu tape screen (Varolex), concentric Cu (N2XCH), LSZH sheath |
Application Scenarios
Where PVC Control & Data Cable from TEBAOFLEX is installed.
Machine Tools & Production Lines
Numbered-core YY, YSLY-JZ, screened CY / YSLYCY-JZ, steel-braided SY / YSLYSY and oil-resistant H05VV5-F / H05VVC4V5-K interconnect cabinets, valves and machine frames.
02CNC Drag Chains & Robotics
Class 6 PUR drag-chain and servo cables (EFK 300 P/CP, S 200 C, JZ-602 RC-PUR, SL 800/801 C, SL 803 C, FD 30810 CP, Servo 55700/60700 CY) for linear axes and multi-axis robots.
03PLC Fieldbus & Industrial Ethernet
PROFINET Type A/B/C Cat5e & Cat6A, PROFIBUS DP/PA, 120 Ω RS-485 Modbus, CAN Bus, DeviceNet, CC-Link 110 Ω, AS-Interface flat bus and FOUNDATION Fieldbus H1.
04Process Instrumentation & BMS
DIN 47100 data cables (LiYY, LiYCY, LiHCH, Li2YCY-P), VDE 0815 installation cables (J-Y(St)Y, JE-Y(St)Y, JE-LiYCY) and EN 50288-7 process instrumentation (RE-2Y(St)Y, RE-2X(St)H).
05Control Cabinets & Switchgear
Harmonised H05V-K / H07V-K PVC, 90 °C H05Z-K / H07Z-K LSZH, KIV / HKIV and 125 °C 21X-LS0H single-core hook-up wires for dense panel wiring and terminal blocks.
06VFD Drives & Fire-Critical Circuits
Varolex 0.6/1 kV copper-tape screened VSD motor cable, FG16(O)R16 / FG16(O)M16 HEPR power cable, N2XH / (N)HXH FE180 E30–E90 fire-resistant cable and Digital LHD sensing cable.
How to Choose PVC Control & Data Cable
Four decisions specify the right cable the first time; send them with your RFQ and our engineers confirm the type designation.
Circuit Function & Voltage
250–500 V peak for DIN 47100 signal/data (LiYY, LiYCY, Li2YCY) and EN 50288-7 instrumentation; 300/500 V or 450/750 V for control and panel wire; 0.6/1 kV for JZ-600 PUR, servo, VFD and power.
Static vs Drag-Chain Motion
Fixed or occasional flexing uses Class 5 PVC/LSZH (YY, YSLY-JZ, LiYCY, H07VV-F). Continuous power chains require Class 6 TPE/PP/EPR cores and a PUR jacket (EFK 300, S 200, SL 800/803 C).
EMC Screen, PiMF or Steel Braid
Overall tinned copper braid (LiYCY, CY, YSLYCY-JZ, H05VVC4V5-K) for drive interference; PiMF individual pair screens (Li2YCY-P, RE-2Y(St)Y) for crosstalk; GSWB (SY, YSLYSY) for mechanical protection.
Oil, LSZH & Fire Performance
Choose EN 50525-2-51 oil-resistant PVC (H05VV5-F) or PUR (JZ-500 PUR, H07BQ-F) for machine oils; LSZH (LiHCH, H07Z-K, N2XH) for low smoke; (N)HXH FE180 for E30–E90 circuit integrity.
Standards & Certifications
ISO 9001 quality management for cable production; ISO 14001 and ISO 45001 for sales and related management. UL and cUL (flexible cord), VDE (EN 50525-2-21), Korea KC, China MA and US MSHA approvals cover the certified types; CE is a third-party verification of conformity (VoC).




Manufacturing Process
From compound to shipment, the production steps and routine tests behind each cable length.
- 1
Compound preparation
EPR, CPE, PUR and silicone compounds are mixed and tested for hardness, tensile strength and elongation before use.
- 2
Conductor stranding
Tinned or bare copper is bunched and rope-stranded to Class 5/6 flexibility for trailing and reeling duty.
- 3
Insulation extrusion
Cores are extruded and continuously vulcanised; wall thickness and spark tests are recorded on every length.
- 4
Core assembly and screening
Cores, earth conductors, pilot and fibre-optic elements are laid up with the fillers and screens the type designation requires.
- 5
Inner and outer sheathing
Reinforced double-sheath constructions are extruded and cured for abrasion, oil and tear resistance.
- 6
Routine electrical tests
Conductor resistance, voltage withstand and insulation resistance tests at the levels set by the referenced standard.
- 7
Mechanical and ageing tests
Bending, tensile, hot-set, ozone and flame tests according to the referenced standard.
- 8
Marking, packing and shipment
Metre marking, drum packing and documentation for worldwide project delivery.
Construction, Layer by Layer
How TEBAOFLEX control, drag-chain, fieldbus and instrumentation cables are built from the conductor outward. For a step-by-step specification check, see how to read PVC insulation and sheath on a control-cable datasheet.
- 1
Conductor & Stranding Class
IEC 60228 Class 5 flexible copper for cabinet, machine and fixed/occasional-flex cables; Class 6 extra-fine copper on continuous drag-chain series (EFK 300, S 200, S 368/369 C, SL 800/803 C); solid or 7/19-strand copper on VDE 0815, EN 50288-7 and fieldbus cables.
- 2
Core Insulation & Impedance Control
PVC TI2 on standard control cables; low-capacitance PE, foam-skin PE or PP/TPE-E on RS-485, PROFIBUS, PROFINET, Li2YCY, RE-2Y(St)Y and servo motor cables; EI6 EPR on H05BQ-F/H07BQ-F; XLPE + mica tape on (N)HXH FE180.
- 3
Core & Pair Identification
DIN 47100 colour code on data cables (LiYY, LiYCY, LiHCH, Li2YCY, S 368/369 C); black numbered cores with or without green/yellow earth (JZ/OZ) on control cables; colour-coded or numbered twisted pairs/triads on fieldbus and instrumentation.
- 4
Lay-Up & Drag-Chain Geometry
Concentric layer stranding for fixed/flexible control cables; short-pitch bundle stranding around low-friction central fillers on high-speed drag-chain and robot cables (S 200, SL 800/803 C, FD 30810 CP).
- 5
EMC Screening & Mechanical Braid
Collective Al/PET foil with tinned drain wire (J-Y(St)Y, RE-2Y(St)Y); individual pair foil screens (PiMF on Li2YCY-P, JE-LiYCY, RE-2Y(St)Y PiMF); ≥80–85 % tinned copper braid (LiYCY, CY, YSLYCY-JZ, S 200 C); or galvanised steel wire braid (SY, YSLYSY). Use the LiYY vs LiYCY screening decision checklist when specifying signal shields.
- 6
Outer Sheath Compound
PVC TM2/TM5 (oil-resistant EN 50525-2-51 on H05VV5-F / H05VVC4V5-K), TMPU polyurethane (JZ-500/600 PUR, H07BQ-F, drag-chain series) for oil, coolant and abrasion, or halogen-free LSZH (LiHCH, H07Z-K, J-H(St)H, N2XH, (N)HXH FE180).
Cable Manufacturing Quality Control
Five-stage quality assurance from incoming copper to the packed drum.
- 01
Raw Material Inspection
Every batch of copper rod, rubber compound and reinforcing material is checked before it reaches the line.
- Copper: conductor resistance, elongation and surface condition on incoming rod and drawn wire
- EPR, CPE, PUR and silicone compounds: hardness, tensile strength, elongation and ageing samples from each mix
- 02
Manufacturing Process Control
Stranding, insulation extrusion, core assembly and sheathing run under recorded process parameters.
- Class 5/6 stranding with lay length and tension monitored for trailing and reeling flexibility
- Continuous-vulcanisation extrusion with wall thickness and spark tests logged on every length
- Operators sign off each stage before the cable moves to the next machine
- 03
Electrical Testing
Finished lengths go through the routine tests required by the referenced VDE, ICEA, IEC or NEK standard.
- Conductor resistance and insulation resistance on every length
- Voltage withstand test at the level set by the referenced standard
- Screen and pilot-core continuity checks for mining and reeling constructions
- 04
Mechanical and Ageing Tests
Samples from production are tested for the duty a mining, crane or submersible cable will actually see.
- Tensile strength and elongation of insulation and sheath before and after ageing
- Hot-set, ozone, oil-immersion and low-temperature bending tests
- Constant-temperature water bath for insulation resistance of submersible constructions
- 05
Flame Test and Final Inspection
Before packing, the cable is checked against the order and the flame-performance requirement of its standard.
- Single-cable vertical flame test to IEC 60332-1-2 where specified
- Metre marking, printing, drum length and appearance inspection
- Packing list with every shipment; test documents for the order confirmed at quotation
Factory & Workshop Gallery
TEBAOFLEX CABLE, No.77 Wusongbang Road, Taicang, Suzhou.




Related Articles
Selection and application guides from the TEBAOFLEX engineering team.

YY vs SY vs CY Control Cable & YSLY vs LiYCY Guide
Compare unbraided YY (YSLY), steel-braided SY (YSLYSY) and copper-screened CY (YSLYCY / LiYCY) 300/500 V control cables, JZ/OZ core coding and EMC routing.
Read more
HSLH, HSLCH (HSLHCH) & HSLHSH LSZH Control Cable Guide
Match zero-halogen HSLH (YY LSZH), bedded vs non-bedded HSLCH / HSLHCH (CY LSZH) and steel-braided HSLHSH (SY LSZH) to public-building and cleanroom specs.
Read more
RS-485 Cable Guide: 120 Ω, Capacitance, AWG
RS-485 cable selection: 120 Ω impedance, low capacitance, twisted pairs and shielding, distance vs baud rate, and what to order.
Read moreFrequently Asked Questions
Quick answers about PVC Control & Data Cable from our engineers.
01How do I choose between PVC control cables (YY, YSLY-JZ, CY, SY) and PUR control or drag-chain cables?
Use flexible PVC control cables (YY, YSLY-JZ, CY, YSLYCY-JZ, SY, YSLYSY) for fixed indoor routing and occasional free flexing without tensile stress. When the cable is exposed to cutting fluids, mineral oils, outdoor weather or continuous travel in an energy chain, select oil-resistant PVC (H05VV5-F / H05VVC4V5-K) or polyurethane (JZ-500 PUR, JZ-600 PUR, JZ-602 RC-PUR, EFK 300 P/CP, S 200 / S 200 C).
02What is the difference between LiYY / LiYCY, Li2YCY-P and EN 50288-7 RE-2Y(St)Y / JE-Y(St)Y?
LiYY (unscreened) and LiYCY (overall tinned copper braid) use PVC insulation and DIN 47100 colour coding for short-to-medium signal and control runs. Li2YCY and Li2YCY-P (PiMF) use low-capacitance polyethylene (PE) insulation on twisted pairs for longer RS-422/RS-485 and analogue links. JE-Y(St)Y / JE-LiYCY (VDE 0815) and RE-2Y(St)Y / RE-2X(St)H (EN 50288-7) are process instrumentation cables built in pairs, triads or quads with collective or individual pair foil screens (PiMF) for 4–20 mA, HART and DCS/PLC cabinets.
03Which fieldbus or Industrial Ethernet cable matches my protocol?
Match the cable's characteristic impedance and geometry to the bus standard: 120 Ω shielded twisted pair for RS-485 Modbus RTU, CAN Bus (ISO 11898-2) and DeviceNet (Thick Trunk & Thin Drop); 150 Ω Type A for PROFIBUS DP and 100 Ω for PROFIBUS PA and FOUNDATION Fieldbus H1 (IEC 61158-2); 110 Ω 3-core shielded cable for CC-Link Ver.1.10/2.00; 2 × 1.5 mm² yellow/black profile cable for AS-Interface (AS-i); and 100 Ω PROFINET Type A (fixed), Type B (flexible) or Type C (drag-chain) Cat5e 4-wire / Cat6A 8-wire for Industrial Ethernet.
04Which cables are built for servo motors and VFD / VSD drives?
For continuous-flex drag chains on servo axes, choose SL 800 / SL 801 C (0.6/1 kV composite power + control pairs), SL 803 C / FD 30810 CP (low-capacitance motor power + brake pairs + feedback/encoder), or UL/CSA Servo 55700 / 60700 CY. For fixed or flexible 0.6/1 kV VSD/VFD motor feeders, Varolex uses a symmetrical 3-core + 3-split-earth XLPE layout with helical copper tape screening for low transfer impedance.
05When should I specify halogen-free (LSZH) or FE180 / E30–E90 fire-resistant cables?
Specify LSZH constructions—H05Z-K / H07Z-K and 21X-LS0H in panels, LiHCH / LiHH for data, J-H(St)H for building bus, RE-2X(St)H for instrumentation, FG16(O)M16 or N2XH / N2XCH for 0.6/1 kV power—in public buildings, tunnels, data centres and rail interiors where low smoke and zero halogen acid gas (IEC 60754 / IEC 61034) are mandatory. Where emergency lighting, smoke extractors or fire alarms must keep operating during a fire, specify (N)HXH FE180 E30–E90.
06What should I send for a quotation?
Send the cable designation or protocol, core or pair count and cross-section (mm² or AWG), voltage rating, screening type (unscreened, collective foil/braid, PiMF, GSWB), installation duty (fixed, occasional flex or drag-chain bend radius and travel speed), sheath compound (PVC, oil-resistant PVC, PUR, EPR/PUR or LSZH) and required cut/drum lengths.
Why Choose Us
A special-cable manufacturer in Taicang, Suzhou, making heavy-duty and special cables since 2014.
Certified Quality
UL and cUL, VDE, Korea KC, China MA and US MSHA approvals for the certified types, CE verification of conformity, and ISO 9001 quality management.
200+ Sets of Equipment
More than 200 sets of advanced production and test equipment at home and abroad, from compounding to final electrical testing.
15 Senior Cable Engineers
Constructions engineered to VDE, ICEA, IEC and NEK 606 standards and checked against the real duty cycle of your equipment.
1,500+ Cable Types
0.6/1 kV to 35 kV heavy-duty rubber cables, reeling and festoon crane cables, submersible, marine, ROV and high-temperature cables.
Custom Cable Design
Special constructions, fibre-optic elements, colours, printing and lengths built to the specification of your project.
Worldwide Project Supply
Cables working in tunnel engineering, marine and offshore equipment, mining, petrochemical, steel and urban construction projects around the world.
Can’t Find What You Need?
Send us the equipment, voltage, cores and operating conditions and our engineers will propose a cable construction and quotation.