EV ProInstall Cat6A SWA LSZH Cable 0.6/1kV for EV Charging
EV ProInstall Cat6A SWA LSZH cable combining 0.6/1kV power cores with Cat6A data, SWA protection, LSZH sheaths, 6mm² power cores and 14× outer-diameter bend radius.
EV ProInstall Cat6A SWA LSZH cable combines power cores with Cat6A twisted data cable for EV charging unit power and flow monitoring.
View the EV charging cable category for combined power-and-data alternatives.
Application & Features
Selection overview
EV ProInstall Cat6A SWA LSZH cable is positioned for EV charging unit power and flow monitoring where a combined cable and additional mechanical protection are required.
- EV charging unitsEV ProInstall Cat6A SWA LSZH cable for combined charging power and flow-monitoring routes.
- External wall routesEV ProInstall Cat6A SWA LSZH cable where the SWA and LSZH construction fit the protected route.
- Tray and ladderEV ProInstall Cat6A SWA LSZH cable for specified tray or ladder installations.
- Concrete or burialEV ProInstall Cat6A SWA LSZH cable where direct burial or concrete installation has the required mechanical protection.
Specifications
Metric data from supplied technical material
The following EV ProInstall Cat6A SWA LSZH cable values are transcribed from the supplied technical material.
Electrical and environmental data
| Parameter | Value |
|---|---|
| Voltage | Power 0.6/1kV; data 0.6/1kV |
| Test voltage | Core to core 5000V; core to screen 2000V |
| Installation temperature | -5°C to +50°C |
| Fixed installation | -30°C to +80°C |
| Minimum bend radius | 14 × outer diameter |
| Power conductors | Class 2 stranded copper, XLPE |
| Data conductors | Class 1 solid copper, screened Cat6A |
| Armour / sheath | SWA; LSZH inner and UV-resistant LSZH outer sheath |
More technical data
EV ProInstall Cat6A SWA LSZH cable dimensions
| Power cores | CSA | Data | Overall diameter | Weight | Pulling tension |
|---|---|---|---|---|---|
| 3 | 6mm² | AWG23 Cat6A | 21.7mm | 1002kg/km | 568N/mm² |
| 5 | 6mm² | AWG23 Cat6A | 25.8mm | 1479kg/km | 909N/mm² |
Electrical characteristics
| Power DC resistance | Data DC resistance | Mutual capacitance | Inductance | L/R ratio | Current at 30°C |
|---|---|---|---|---|---|
| 3.4Ω/km | 9.38Ω/100m | 1000nF/km | 115mH/km | 1µH/Ω | 60A air / 54A clipped / 44A trunking / 46A |
Selection note: current and data ratings depend on installation method and conductor temperature.
Standards & References
Confirm project scope before ordering
- Listed cable referencesThe supplied material references IEC 60502-1, IEC/EN 60228, IEC/EN 61034-1/2, IEC/EN 60754-1/2, IEC/EN 60332-1-2 and IEC/EN 60332-3-24.
- Data and environmentThe source material lists TIA/EIA 568-B.10, IEC 61158-5, UV resistance to EN 50396 and abrasion resistance to EN 50289-3-7.
- Approval noteThe supplied sheet lists BSI Kitemark verification KM 662609 and Construction Products Regulation EN 50575.
Construction
Material and build-up
The construction combines Class 2 stranded copper power cores and Class 1 solid copper Cat6A data conductors.
- Power cores: Class 2 stranded copper with XLPE insulation.
- Cat6A data: Class 1 solid copper with PE insulation and screened data construction.
- Data screen: Al/PET tape with tinned copper drain wire.
- Sheaths: LSZH orange Cat6A data sheath, LSZH black inner sheath and UV-resistant LSZH outer sheath.
Request this cable.