Product Categories
Heavy-duty rubber cables for mining, port cranes, submersible pumps, EV charging, elevators and marine duty. Pick a family to filter the range.
Flexible PVC Control & Low-Frequency Data Cables
Comprehensive European and UL/CSA industrial automation cables including YSLY-JZ/OZ, Ölflex-equivalent CY/SY screened control cables, LiYY / LiYCY DIN 47100 data transmission cables and drag-chain control series across 2 to 61 cores.




Flexible PVC Control & Low-Frequency Data Cables — Engineering Selection & Custom Manufacturing
Comprehensive European and UL/CSA industrial automation cables including YSLY-JZ/OZ, Ölflex-equivalent CY/SY screened control cables, LiYY / LiYCY DIN 47100 data transmission cables and drag-chain control series across 2 to 61 cores.
Showing 17–32 of 115 results
-

600V ICEA S-73-532 Multi-Conductor Control Cable (PVC, XLPE, LSZH & Armored)
600v icea s-73-532 multi-conductor control cable (pvc, xlpe, lszh & armored) icea-s73-532-600v-control-cable-armored pvc data 600 v (nema wc 57) and ul 1277 cables (2 to 48 conductors, 16 awg, 14 12 awg & 10 awg) are engineered with flexible stranded copper s73532 multiconductor pvc, armored iceas73532600vcontrolcablearmored 600viceas73532multiconductorcontrolcablepvcxlpelszharmorediceas73532600vcontrolcablearmored -

600V ICEA S-95-658 Power Cable & CSA C22.2 No. 131 Interlock Armored Cable
600v icea s-95-658 power cable & csa c22.2 no. 131 interlock armored icea-s95-658-600v-power-csa-c22-2-no131-teck-cable pvc control data 600 v / nema wc 70 distribution cables (1 to 4 conductors, 14 awg 1000 kcmil, in 75 °c pvc/pvc, 90 xlpe/pvc bare or tinned copper, and s95658 c222 no iceas95658600vpowercsac222no131teckcable 600viceas95658powercablecsac222no131interlockarmoredcableiceas95658600vpowercsac222no131teckcable -

600V Mini-Split VRF HVAC Cable (TC-ER / Shielded / MC) & CL2 Thermostat Wire
600v mini-split vrf hvac cable (tc-er / shielded mc) & cl2 thermostat wire 600v-mini-split-hvac-tc-er-mc-cl2-thermostat-cable pvc control data purpose-engineered for modern variable-refrigerant-flow (vrf) and ductless heat-pump installations alongside commercial/residential zone controls, this product line unites 600 v power & communication cables (14/4, 14/7, 16/4 awg minisplit tcer mc 600vminisplithvactcermccl2thermostatcable 600vminisplitvrfhvaccabletcershieldedmccl2thermostatwire600vminisplithvactcermccl2thermostatcable -

600V Twisted Submersible Well Pump Cable & Shielded 5G Small-Cell TC-ER Cable
600v twisted submersible well pump cable & shielded 5g small-cell tc-er 600v-twisted-pvc-submersible-well-pump-5g-small-cell-tc-er-cable pvc control data engineered for north american municipal/agricultural groundwater extraction and outdoor / telecom remote radio head (rrh) dc power distribution, this specialized 600 v page covers ul 83 3-core & smallcell tcer 600vtwistedpvcsubmersiblewellpump5gsmallcelltcercable 600vtwistedsubmersiblewellpumpcableshielded5gsmallcelltcercable600vtwistedpvcsubmersiblewellpump5gsmallcelltcercable -

600V UL 1569 Type MC THHN/THWN Aluminum Interlocked Armor & Jacketed MC Cable
600v ul 1569 type mc thhn/thwn aluminum interlocked armor & jacketed cable ul1569-type-mc-thhn-interlocked-armor-pvc-jacketed-cable pvc control data engineered to and nec article 330 for commercial high-rise branch circuits, healthcare/data-center distribution, industrial plant feeders, this 600 v metal-clad (type mc) range encompasses bare lightweight thhnthwn ul1569typemcthhninterlockedarmorpvcjacketedcable 600vul1569typemcthhnthwnaluminuminterlockedarmorjacketedmccableul1569typemcthhninterlockedarmorpvcjacketedcable -

600V UL 854 Type SER / Type SEU Service Entrance & UL 493 Type UF-B Cable
600v ul 854 type ser / seu service entrance & 493 uf-b cable ul854-type-ser-seu-service-entrance-ul493-uf-b-cable pvc control data manufactured to (nec article 338) and 340) for residential, multifamily, light commercial power distribution, this 600 v underground feeder family comprises ufb ul854typeserseuserviceentranceul493ufbcable 600vul854typesertypeseuserviceentranceul493typeufbcableul854typeserseuserviceentranceul493ufbcable -

600V/1000V Type TC-ER XHHW-2 Tray, 600V Aluminum URD (USE-2) & Type NM-B Cable
600v/1000v type tc-er xhhw-2 tray, 600v aluminum urd (use-2) & nm-b cable type-tc-er-xhhw-2-aluminum-urd-use-2-nm-b-cable pvc control data ul 1277 power tray cables with 90 °c copper conductors and green insulated ground (3/c & 4/c, 8 awg to 750 kcmil), ansi/icea s-105-692 854 600v1000v tcer xhhw2 use2 nmb typetcerxhhw2aluminumurduse2nmbcable 600v1000vtypetcerxhhw2tray600valuminumurduse2typenmbcabletypetcerxhhw2aluminumurduse2nmbcable 600v1000vtypetcerxhhw2tray600valuminumurdtypenmbcabletypetcerxhhw2aluminumurduse2nmbcable -

600V/1000V UL 44 XHHW-2 & CSA RW90 Single-Core XLPE Wire (Copper & AA-8000 Al)
600v/1000v ul 44 xhhw-2 & csa rw90 single-core xlpe wire (copper aa-8000 al) ul44-xhhw2-csa-c22-2-no38-rw90-cu-aa8000-al-wire pvc control data cable engineered to both u.s. (type xhhw-2, 600 v / 1000 v) and canadian c22.2 no. 38 rw90, v, -40 °c cold bend impact) 600v1000v xhhw2 singlecore copper aa8000 al ul44xhhw2csac222no38rw90cuaa8000alwire 600v1000vul44xhhw2csarw90singlecorexlpewirecopperaa8000alul44xhhw2csac222no38rw90cuaa8000alwire -

90 °C H07V2-R / H07V2-U Conduit Wire & H05V2V2-F (60227 IEC 53) Cable
90 °c h07v2-r / h07v2-u conduit wire & h05v2v2-f (60227 iec 53) cable h07v2-r-h07v2-u-90c-wire-h05v2v2-f-60227-iec-53-cable tbx-h07v2-r-h07v2-u-90c-wire-h05v2v2-f-6 industrial power control pvc data in 45–55 gulf mechanical rooms, rooftop hvac chiller skids, commercial boiler houses, and enclosed luminaire ceiling voids, standard 70 wires (h07v-r h05vv-f) suffer severe ambient temperature derating (kt h07v2r h07v2u h05v2v2f 60227 53 h07v2rh07v2u90cwireh05v2v2f60227iec53cable tbxh07v2rh07v2u90cwireh05v2v2f6 90ch07v2rh07v2uconduitwireh05v2v2f60227iec53cableh07v2rh07v2u90cwireh05v2v2f60227iec53cabletbxh07v2rh07v2u90cwireh05v2v2f6 90ch07v2rh07v2uconduitwireh05v2v2fcableh07v2rh07v2u90cwireh05v2v2f60227iec53cabletbxh07v2rh07v2u90cwireh05v2v2f6 -

A-DQ(ZN)B2Y, U-DQ(ZN)BH & A-DQ(ZN)(SR)B2Y Loose-Tube Fiber Optic Cable
a-dq(zn)b2y, u-dq(zn)bh & a-dq(zn)(sr)b2y loose-tube fiber optic cable a-dq-zn-b2y-u-dq-zn-bh-loose-tube-fiber-optic-cable pvc control data a-dq2y(zn)b2y and a-dq2y(zn)2y (outdoor pe-sheathed dielectric), u-dq(zn)bh, u-dqh(zn)bh u-dqh(zn)h (universal indoor/outdoor lszh dielectric, cpr cca/dca/eca), corrugated-steel-tape-armored a-dq(zn)(sr)b2y, a-dq(zn)b2y(sr)2y. vde 0888 dielectric codesa-dq(zn)b2y, a-dq2y(zn)b2y, a-dq2y(zn)2y, u-dqh(zn)bh, u-dqh(zn)hvde cst a-dqb2y, u-dqbh a-dqb2y adqznb2y, udqznbh adqznsrb2y loosetube adqznb2yudqznbhloosetubefiberopticcable adqb2y, udqbh adqb2y adqznb2yudqznbhadqznsrb2yloosetubefiberopticcableadqznb2yudqznbhloosetubefiberopticcable adqb2yudqbhadqb2yloosetubefiberopticcableadqznb2yudqznbhloosetubefiberopticcable -

ACSR, ACSR/TW Trapezoidal & ACSR/T-2 Bare Overhead Conductor
acsr, acsr/tw trapezoidal & acsr/t-2 bare overhead conductor acsr-acsr-tw-acsr-t2-bare-overhead-conductor pvc control data cable engineered for electric utility distribution feeders, river crossings, and high-voltage / extra-high-voltage (69 kv to 765 kv) transmission grids, our & anti-galloping family combines acsrtw acsrt2 acsracsrtwacsrt2bareoverheadconductor acsracsrtwtrapezoidalacsrt2bareoverheadconductoracsracsrtwacsrt2bareoverheadconductor -

API 17E Subsea Production Umbilical, API 17G IWOCS, EFL/EOFL & MV Pump Jumper
api 17e subsea production umbilical, 17g iwocs, efl/eofl & mv pump jumper api-17e-subsea-production-umbilical-api-17g-iwocs-efl-eofl-mv-booster-jumper pvc control data cable engineered for deepwater oil & gas trees, manifolds, well intervention vessels, and seafloor multiphase boosting stations, this offshore power umbilical portfolio unites spec / iso efleofl api17esubseaproductionumbilicalapi17giwocsefleoflmvboosterjumper api17esubseaproductionumbilicalapi17giwocsefleoflmvpumpjumperapi17esubseaproductionumbilicalapi17giwocsefleoflmvboosterjumper -

AS-Interface (AS-i) Yellow & Black Flat Profile Bus Cable (2×1.5 mm²)
as-interface (as-i) yellow & black flat profile bus cable (2×1.5 mm²) as-interface-asi-flat-profile-yellow-black-bus-cable pvc control data 2×1.5 mm² and 2×2.5 reverse-polarity-protected trapezoidal cables in (30v dc as-i + power) (24v auxiliary power), engineered self-healing epdm rubber, asinterface asi 2×15 asinterfaceasiflatprofileyellowblackbuscable asinterfaceasiyellowblackflatprofilebuscable215mmasinterfaceasiflatprofileyellowblackbuscable asinterfaceyellowblackflatprofilebuscableasinterfaceasiflatprofileyellowblackbuscable -

BPYJVP, BPYJVP2 & BPYJVPP2 (0.6/1 kV) 3+3 Symmetrical Copper-Screened VFD Cable
bpyjvp, bpyjvp2 & bpyjvpp2 (0.6/1 kv) 3+3 symmetrical copper-screened vfd cable bpyjvp-bpyjvp2-bpyjvpp2-0-6-1kv-3plus3-copper-screened-vfd-cable pvc control data bpyjvp2, and kv, 3.5 kv / 5 min ac impulse test) are industrial xlpe-insulated (90 °c) 3+1 variable frequency drive (vfd) power cables engineered in 061 copperscreened bpyjvpbpyjvp2bpyjvpp2061kv3plus3copperscreenedvfdcable bpyjvpbpyjvp2bpyjvpp2061kv33symmetricalcopperscreenedvfdcablebpyjvpbpyjvp2bpyjvpp2061kv3plus3copperscreenedvfdcable bpyjvpbpyjvp2bpyjvpp233symmetricalcopperscreenedvfdcablebpyjvpbpyjvp2bpyjvpp2061kv3plus3copperscreenedvfdcable -

BS 7870-3.40 LV Waveform, BS 7870-4.10 MV (11–33 kV) & 4-Sector Al Utility Cable
bs 7870-3.40 lv waveform, 7870-4.10 mv (11–33 kv) & 4-sector al utility cable bs-7870-3-40-waveform-bs-7870-4-10-mv-utility-cable pvc control data (0.6/1 kv solid aluminum conductor sac xlpe waveform cne), (6.35/11 kv, 12.7/22 and 19/33 single-core triplex xlpe) iec 60502-1 0.6/1 7870340 7870410 11–33 4sector bs7870340waveformbs7870410mvutilitycable bs7870340lvwaveformbs7870410mv1133kv4sectoralutilitycablebs7870340waveformbs7870410mvutilitycable bs7870340lvwaveformbs7870410mv4sectoralutilitycablebs7870340waveformbs7870410mvutilitycable -

CAN Bus 120 Ω Cable: ISO 11898-2 Shielded Twisted Pair for CANopen & J1939
can bus 120 ω cable: iso 11898-2 shielded twisted pair for canopen & j1939 can-bus-120-ohm-shielded-twisted-pair-cable pvc control data cable wind power tebaoflex is a low-capacitance twisted-pair engineered to can, canopen, fd and sae networks: foamed polyethylene (o2y) cores, fine-stranded copper 118982 canbus120ohmshieldedtwistedpaircable canbus120cableiso118982shieldedtwistedpairforcanopenj1939canbus120ohmshieldedtwistedpaircable
Product Advantages
What sets TEBAOFLEX PVC Control & Data Cable apart in service.
Six Complete Automation Families
Control, PUR drag-chain & servo, fieldbus & Industrial Ethernet, DIN 47100 / EN 50288-7 instrumentation, panel wire and 0.6/1 kV VFD/fire-safety cables from one manufacturer.
Class 5 & Class 6 Stranding
Class 5 flexible copper for cabinet, machine and fixed/occasional-flex routing; Class 6 extra-fine copper on EFK 300, S 200, S 368/369 C and SL 800/803 C for continuous drag chains.
EMC & PiMF Screening
Tinned copper braids (LiYCY, CY, YSLYCY-JZ, S 200 C, SL 801/803 C), copper-tape VSD screens (Varolex) and individual foil-screened pairs (PiMF on Li2YCY-P, JE-LiYCY, RE-2Y(St)Y).
PUR, Oil-Resistant & Steel-Braided Sheaths
TMPU/PUR sheaths for coolant, cutting oil and drag-chain abrasion; EN 50525-2-51 oil-resistant PVC (H05VV5-F, H05VVC4V5-K); galvanised steel wire braid (SY, YSLYSY) for swarf impact.
Controlled-Impedance Fieldbus & Ethernet
120 Ω RS-485, CAN Bus and DeviceNet, 150 Ω PROFIBUS DP, 100 Ω PROFIBUS PA and FOUNDATION Fieldbus H1, 110 Ω CC-Link, and 100 Ω PROFINET Type A/B/C Cat5e and Cat6A.
LSZH & FE180/E30–E90 Fire Safety
Halogen-free LiHCH/LiHH, H05Z-K/H07Z-K, J-H(St)H, RE-2X(St)H, N2XH/N2XCH and DIN 4102-12 E30–E90 circuit-integrity (N)HXH FE180 plus Digital LHD fire sensing cables.
Control, Fieldbus, Drag-Chain & Instrumentation Range
Sixteen core product series across the 44-product category; click any series to view its full dimensional and electrical tables.
| Model / Series | Sub-Family | Voltage / Impedance | Conductor & Insulation | Screen / Protection & Sheath |
|---|---|---|---|---|
| YY / YSLY-JZ & YSLY-OZ | Flexible PVC Control | 300/500 V | Class 5 Cu, TI2 PVC cores, numbered + G/Y or OZ | Unscreened, TM2 grey PVC sheath (-40 °C fixed / +70 °C) |
| CY / YSLYCY-JZ | EMC Screened PVC Control | 300/500 V | Class 5 Cu, PVC cores, PET tape + tinned Cu braid | EMC braid screen, grey or transparent PVC sheath |
| SY / YSLYSY | Steel-Wire-Braided Control | 300/500 V | Class 5 Cu, PVC inner sheath + GSWB armour | Galvanised steel wire braid, transparent PVC outer sheath |
| H05VV5-F & H05VVC4V5-K | EN 50525-2-51 Oil-Resistant Control | 300/500 V | Class 5 Cu, PVC cores; unscreened or tinned Cu braid (C4) | Oil-resistant TM5 PVC sheath for machine tools |
| JZ-500 PUR & JZ-600 PUR | Oil- & Abrasion-Resistant PUR Control | 300/500 V & 0.6/1 kV | Class 5 Cu, PVC/TI2 cores, numbered + G/Y | TMPU polyurethane sheath (-40 °C to +80 °C, UV/oil resistant) |
| EFK 300 P/CP, S 200 C & JZ-602 RC-PUR | Continuous-Flex Drag-Chain Control | 300/500 V & 600 V | Class 6 extra-fine Cu, TPE/PP/PVC cores | Unscreened or tinned Cu braid, low-adhesion PUR jacket |
| SL 800/801/803 C & FD 30810 CP | Composite PUR Servo & Encoder Drag Chain | 0.6/1 kV (Power) + 300 V | Class 6 Cu, PP/TPE low-capacitance power + brake pairs | Screened brake/control pairs + ≥85 % overall tinned Cu braid, PUR |
| H05BQ-F / H07BQ-F Duosheath | EPR/PUR Heavy-Duty Trailing & Worksite | 300/500 V & 450/750 V | Class 5 Cu, EI6 EPR rubber cores | TMPU orange/yellow/black PUR sheath (-40 °C to +90 °C) |
| LiYY, LiYCY & LiHCH / LiHH | DIN 47100 Electronic Data & Signal | 250–500 V peak | Fine-stranded Cu (0.14–1.5 mm²), PVC or LSZH cores | Unscreened or tinned Cu braid; PVC or halogen-free LSZH sheath |
| Li2YCY / Li2YCY-P (PiMF) | Low-Capacitance PE Twisted-Pair Data | 250 V / 300 V | Stranded Cu, low-cap PE pairs (0.14–1.0 mm²) | Overall tinned Cu braid (+ PiMF pair foil on Li2YCY-P) |
| 120 Ω RS-485, CAN Bus & DeviceNet | 120 Ω Serial Fieldbus | 300 V | Twisted pairs, foam-skin PE, 120 Ω impedance | Al/PET foil + tinned Cu drain wire + tinned Cu braid; PVC/PUR/LSZH |
| PROFIBUS DP/PA, FF H1, CC-Link & AS-i | Process & Factory Fieldbus | 150 Ω / 100 Ω / 110 Ω | Solid or stranded Cu (Type A/B/drag-chain), PE/foam-PE | Foil + braid screening (DP/PA/FF H1/CC-Link); AS-i flat profile |
| PROFINET Type A / B / C Cat5e & Cat6A | 100 Ω Industrial Ethernet | 100 Ω (Cat5e / Cat6A) | 1/7/19-wire Cu, Star-Quad (Cat5e) or 4-pair (Cat6A) | SF/UTP or S/FTP foil + tinned Cu braid, green PVC/PUR/LSZH |
| J-Y(St)Y, JE-Y(St)Y & EN 50288-7 RE-2Y(St)Y | VDE 0815 & EN 50288-7 Instrumentation | 300 V / 500 V | Pairs/triads in PVC, PE (2Y) or XLPE (2X), 0.5–2.5 mm² | Collective (St) Al/PET foil or PiMF + drain wire, PVC or LSZH |
| H05V-K / H07V-K, H05Z-K / H07Z-K & KIV | Harmonised Panel & Switchboard Wire | 300/500 V to 0.6/1 kV | Class 5 flexible Cu, 0.5–240 mm² single-core | TI1 PVC (70 °C), EI5/LSZH (90 °C H07Z-K) or 125 °C 21X-LS0H |
| Varolex VSD, FG16(O)R16 & (N)HXH FE180 | 0.6/1 kV VFD, HEPR & Fire-Resistant Power | 0.6/1 kV | XLPE, G16 HEPR or mica-tape + XLPE (FE180 E30–E90) | Cu tape screen (Varolex), concentric Cu (N2XCH), LSZH sheath |
Application Scenarios
Where PVC Control & Data Cable from TEBAOFLEX is installed.
Machine Tools & Production Lines
Numbered-core YY, YSLY-JZ, screened CY / YSLYCY-JZ, steel-braided SY / YSLYSY and oil-resistant H05VV5-F / H05VVC4V5-K interconnect cabinets, valves and machine frames.
02CNC Drag Chains & Robotics
Class 6 PUR drag-chain and servo cables (EFK 300 P/CP, S 200 C, JZ-602 RC-PUR, SL 800/801 C, SL 803 C, FD 30810 CP, Servo 55700/60700 CY) for linear axes and multi-axis robots.
03PLC Fieldbus & Industrial Ethernet
PROFINET Type A/B/C Cat5e & Cat6A, PROFIBUS DP/PA, 120 Ω RS-485 Modbus, CAN Bus, DeviceNet, CC-Link 110 Ω, AS-Interface flat bus and FOUNDATION Fieldbus H1.
04Process Instrumentation & BMS
DIN 47100 data cables (LiYY, LiYCY, LiHCH, Li2YCY-P), VDE 0815 installation cables (J-Y(St)Y, JE-Y(St)Y, JE-LiYCY) and EN 50288-7 process instrumentation (RE-2Y(St)Y, RE-2X(St)H).
05Control Cabinets & Switchgear
Harmonised H05V-K / H07V-K PVC, 90 °C H05Z-K / H07Z-K LSZH, KIV / HKIV and 125 °C 21X-LS0H single-core hook-up wires for dense panel wiring and terminal blocks.
06VFD Drives & Fire-Critical Circuits
Varolex 0.6/1 kV copper-tape screened VSD motor cable, FG16(O)R16 / FG16(O)M16 HEPR power cable, N2XH / (N)HXH FE180 E30–E90 fire-resistant cable and Digital LHD sensing cable.
How to Choose PVC Control & Data Cable
Four decisions specify the right cable the first time; send them with your RFQ and our engineers confirm the type designation.
Circuit Function & Voltage
250–500 V peak for DIN 47100 signal/data (LiYY, LiYCY, Li2YCY) and EN 50288-7 instrumentation; 300/500 V or 450/750 V for control and panel wire; 0.6/1 kV for JZ-600 PUR, servo, VFD and power.
Static vs Drag-Chain Motion
Fixed or occasional flexing uses Class 5 PVC/LSZH (YY, YSLY-JZ, LiYCY, H07VV-F). Continuous power chains require Class 6 TPE/PP/EPR cores and a PUR jacket (EFK 300, S 200, SL 800/803 C).
EMC Screen, PiMF or Steel Braid
Overall tinned copper braid (LiYCY, CY, YSLYCY-JZ, H05VVC4V5-K) for drive interference; PiMF individual pair screens (Li2YCY-P, RE-2Y(St)Y) for crosstalk; GSWB (SY, YSLYSY) for mechanical protection.
Oil, LSZH & Fire Performance
Choose EN 50525-2-51 oil-resistant PVC (H05VV5-F) or PUR (JZ-500 PUR, H07BQ-F) for machine oils; LSZH (LiHCH, H07Z-K, N2XH) for low smoke; (N)HXH FE180 for E30–E90 circuit integrity.
Standards & Certifications
ISO 9001 quality management for cable production; ISO 14001 and ISO 45001 for sales and related management. UL and cUL (flexible cord), VDE (EN 50525-2-21), Korea KC, China MA and US MSHA approvals cover the certified types; CE is a third-party verification of conformity (VoC).




Manufacturing Process
From compound to shipment, the production steps and routine tests behind each cable length.
- 1
Compound preparation
EPR, CPE, PUR and silicone compounds are mixed and tested for hardness, tensile strength and elongation before use.
- 2
Conductor stranding
Tinned or bare copper is bunched and rope-stranded to Class 5/6 flexibility for trailing and reeling duty.
- 3
Insulation extrusion
Cores are extruded and continuously vulcanised; wall thickness and spark tests are recorded on every length.
- 4
Core assembly and screening
Cores, earth conductors, pilot and fibre-optic elements are laid up with the fillers and screens the type designation requires.
- 5
Inner and outer sheathing
Reinforced double-sheath constructions are extruded and cured for abrasion, oil and tear resistance.
- 6
Routine electrical tests
Conductor resistance, voltage withstand and insulation resistance tests at the levels set by the referenced standard.
- 7
Mechanical and ageing tests
Bending, tensile, hot-set, ozone and flame tests according to the referenced standard.
- 8
Marking, packing and shipment
Metre marking, drum packing and documentation for worldwide project delivery.
Construction, Layer by Layer
How TEBAOFLEX control, drag-chain, fieldbus and instrumentation cables are built from the conductor outward. For a step-by-step specification check, see how to read PVC insulation and sheath on a control-cable datasheet.
- 1
Conductor & Stranding Class
IEC 60228 Class 5 flexible copper for cabinet, machine and fixed/occasional-flex cables; Class 6 extra-fine copper on continuous drag-chain series (EFK 300, S 200, S 368/369 C, SL 800/803 C); solid or 7/19-strand copper on VDE 0815, EN 50288-7 and fieldbus cables.
- 2
Core Insulation & Impedance Control
PVC TI2 on standard control cables; low-capacitance PE, foam-skin PE or PP/TPE-E on RS-485, PROFIBUS, PROFINET, Li2YCY, RE-2Y(St)Y and servo motor cables; EI6 EPR on H05BQ-F/H07BQ-F; XLPE + mica tape on (N)HXH FE180.
- 3
Core & Pair Identification
DIN 47100 colour code on data cables (LiYY, LiYCY, LiHCH, Li2YCY, S 368/369 C); black numbered cores with or without green/yellow earth (JZ/OZ) on control cables; colour-coded or numbered twisted pairs/triads on fieldbus and instrumentation.
- 4
Lay-Up & Drag-Chain Geometry
Concentric layer stranding for fixed/flexible control cables; short-pitch bundle stranding around low-friction central fillers on high-speed drag-chain and robot cables (S 200, SL 800/803 C, FD 30810 CP).
- 5
EMC Screening & Mechanical Braid
Collective Al/PET foil with tinned drain wire (J-Y(St)Y, RE-2Y(St)Y); individual pair foil screens (PiMF on Li2YCY-P, JE-LiYCY, RE-2Y(St)Y PiMF); ≥80–85 % tinned copper braid (LiYCY, CY, YSLYCY-JZ, S 200 C); or galvanised steel wire braid (SY, YSLYSY). Use the LiYY vs LiYCY screening decision checklist when specifying signal shields.
- 6
Outer Sheath Compound
PVC TM2/TM5 (oil-resistant EN 50525-2-51 on H05VV5-F / H05VVC4V5-K), TMPU polyurethane (JZ-500/600 PUR, H07BQ-F, drag-chain series) for oil, coolant and abrasion, or halogen-free LSZH (LiHCH, H07Z-K, J-H(St)H, N2XH, (N)HXH FE180).
Cable Manufacturing Quality Control
Five-stage quality assurance from incoming copper to the packed drum.
- 01
Raw Material Inspection
Every batch of copper rod, rubber compound and reinforcing material is checked before it reaches the line.
- Copper: conductor resistance, elongation and surface condition on incoming rod and drawn wire
- EPR, CPE, PUR and silicone compounds: hardness, tensile strength, elongation and ageing samples from each mix
- 02
Manufacturing Process Control
Stranding, insulation extrusion, core assembly and sheathing run under recorded process parameters.
- Class 5/6 stranding with lay length and tension monitored for trailing and reeling flexibility
- Continuous-vulcanisation extrusion with wall thickness and spark tests logged on every length
- Operators sign off each stage before the cable moves to the next machine
- 03
Electrical Testing
Finished lengths go through the routine tests required by the referenced VDE, ICEA, IEC or NEK standard.
- Conductor resistance and insulation resistance on every length
- Voltage withstand test at the level set by the referenced standard
- Screen and pilot-core continuity checks for mining and reeling constructions
- 04
Mechanical and Ageing Tests
Samples from production are tested for the duty a mining, crane or submersible cable will actually see.
- Tensile strength and elongation of insulation and sheath before and after ageing
- Hot-set, ozone, oil-immersion and low-temperature bending tests
- Constant-temperature water bath for insulation resistance of submersible constructions
- 05
Flame Test and Final Inspection
Before packing, the cable is checked against the order and the flame-performance requirement of its standard.
- Single-cable vertical flame test to IEC 60332-1-2 where specified
- Metre marking, printing, drum length and appearance inspection
- Packing list with every shipment; test documents for the order confirmed at quotation
Factory & Workshop Gallery
TEBAOFLEX CABLE, No.77 Wusongbang Road, Taicang, Suzhou.




Related Articles
Selection and application guides from the TEBAOFLEX engineering team.

YY vs SY vs CY Control Cable & YSLY vs LiYCY Guide
Compare unbraided YY (YSLY), steel-braided SY (YSLYSY) and copper-screened CY (YSLYCY / LiYCY) 300/500 V control cables, JZ/OZ core coding and EMC routing.
Read more
HSLH, HSLCH (HSLHCH) & HSLHSH LSZH Control Cable Guide
Match zero-halogen HSLH (YY LSZH), bedded vs non-bedded HSLCH / HSLHCH (CY LSZH) and steel-braided HSLHSH (SY LSZH) to public-building and cleanroom specs.
Read more
RS-485 Cable Guide: 120 Ω, Capacitance, AWG
RS-485 cable selection: 120 Ω impedance, low capacitance, twisted pairs and shielding, distance vs baud rate, and what to order.
Read moreFrequently Asked Questions
Quick answers about PVC Control & Data Cable from our engineers.
01How do I choose between PVC control cables (YY, YSLY-JZ, CY, SY) and PUR control or drag-chain cables?
Use flexible PVC control cables (YY, YSLY-JZ, CY, YSLYCY-JZ, SY, YSLYSY) for fixed indoor routing and occasional free flexing without tensile stress. When the cable is exposed to cutting fluids, mineral oils, outdoor weather or continuous travel in an energy chain, select oil-resistant PVC (H05VV5-F / H05VVC4V5-K) or polyurethane (JZ-500 PUR, JZ-600 PUR, JZ-602 RC-PUR, EFK 300 P/CP, S 200 / S 200 C).
02What is the difference between LiYY / LiYCY, Li2YCY-P and EN 50288-7 RE-2Y(St)Y / JE-Y(St)Y?
LiYY (unscreened) and LiYCY (overall tinned copper braid) use PVC insulation and DIN 47100 colour coding for short-to-medium signal and control runs. Li2YCY and Li2YCY-P (PiMF) use low-capacitance polyethylene (PE) insulation on twisted pairs for longer RS-422/RS-485 and analogue links. JE-Y(St)Y / JE-LiYCY (VDE 0815) and RE-2Y(St)Y / RE-2X(St)H (EN 50288-7) are process instrumentation cables built in pairs, triads or quads with collective or individual pair foil screens (PiMF) for 4–20 mA, HART and DCS/PLC cabinets.
03Which fieldbus or Industrial Ethernet cable matches my protocol?
Match the cable's characteristic impedance and geometry to the bus standard: 120 Ω shielded twisted pair for RS-485 Modbus RTU, CAN Bus (ISO 11898-2) and DeviceNet (Thick Trunk & Thin Drop); 150 Ω Type A for PROFIBUS DP and 100 Ω for PROFIBUS PA and FOUNDATION Fieldbus H1 (IEC 61158-2); 110 Ω 3-core shielded cable for CC-Link Ver.1.10/2.00; 2 × 1.5 mm² yellow/black profile cable for AS-Interface (AS-i); and 100 Ω PROFINET Type A (fixed), Type B (flexible) or Type C (drag-chain) Cat5e 4-wire / Cat6A 8-wire for Industrial Ethernet.
04Which cables are built for servo motors and VFD / VSD drives?
For continuous-flex drag chains on servo axes, choose SL 800 / SL 801 C (0.6/1 kV composite power + control pairs), SL 803 C / FD 30810 CP (low-capacitance motor power + brake pairs + feedback/encoder), or UL/CSA Servo 55700 / 60700 CY. For fixed or flexible 0.6/1 kV VSD/VFD motor feeders, Varolex uses a symmetrical 3-core + 3-split-earth XLPE layout with helical copper tape screening for low transfer impedance.
05When should I specify halogen-free (LSZH) or FE180 / E30–E90 fire-resistant cables?
Specify LSZH constructions—H05Z-K / H07Z-K and 21X-LS0H in panels, LiHCH / LiHH for data, J-H(St)H for building bus, RE-2X(St)H for instrumentation, FG16(O)M16 or N2XH / N2XCH for 0.6/1 kV power—in public buildings, tunnels, data centres and rail interiors where low smoke and zero halogen acid gas (IEC 60754 / IEC 61034) are mandatory. Where emergency lighting, smoke extractors or fire alarms must keep operating during a fire, specify (N)HXH FE180 E30–E90.
06What should I send for a quotation?
Send the cable designation or protocol, core or pair count and cross-section (mm² or AWG), voltage rating, screening type (unscreened, collective foil/braid, PiMF, GSWB), installation duty (fixed, occasional flex or drag-chain bend radius and travel speed), sheath compound (PVC, oil-resistant PVC, PUR, EPR/PUR or LSZH) and required cut/drum lengths.
Why Choose Us
A special-cable manufacturer in Taicang, Suzhou, making heavy-duty and special cables since 2014.
Certified Quality
UL and cUL, VDE, Korea KC, China MA and US MSHA approvals for the certified types, CE verification of conformity, and ISO 9001 quality management.
200+ Sets of Equipment
More than 200 sets of advanced production and test equipment at home and abroad, from compounding to final electrical testing.
15 Senior Cable Engineers
Constructions engineered to VDE, ICEA, IEC and NEK 606 standards and checked against the real duty cycle of your equipment.
1,500+ Cable Types
0.6/1 kV to 35 kV heavy-duty rubber cables, reeling and festoon crane cables, submersible, marine, ROV and high-temperature cables.
Custom Cable Design
Special constructions, fibre-optic elements, colours, printing and lengths built to the specification of your project.
Worldwide Project Supply
Cables working in tunnel engineering, marine and offshore equipment, mining, petrochemical, steel and urban construction projects around the world.
Can’t Find What You Need?