PV1-F, Dual-Rated PV1-F / UL 4703 (Cu & Al) & Twin Parallel Solar PV Cable
2 PfG 1169/08.2007 PV1-F (0.6/1 kV AC / 1.8 kV DC max), Dual-Rated PV1-F & UL 4703 PV Wire (600 V / 1000 V / 2000 V Class 5 tinned copper 1.5–240 mm² / 14 AWG–4/0 AWG), Twin Parallel & Stainless-Steel Rodent-Armored DUO Solar Cable (2×4.0 to 2×10 mm²), UL 4703 49-Strand High-Flex Copper Tracker Wire (10 & 8 AWG).
- Model designationsPV1-F, Dual-Rated PV1-F / UL 4703, Twin DUO PV (+S Rodent Braid), 49-Strand Cu PV & AA-8000 Al PV
- Reference standards2 PfG 1169/08.2007 (PV1-F), UL 4703 (PV Wire), UL 854 (USE-2), UL 44 (RHH/RHW-2), NEC Art. 690
- Rated voltage0.6/1 kV AC / 1.8 kV DC max (PV1-F); 600 V, 1000 V & 2000 V (UL 4703 Cu & AA-8000 Al)
- ConductorsClass 5 tinned Cu (PV1-F); 7/19/37/49/61-str Cu (UL 4703); Compact AA-8000 Al (8 AWG–1000 kcmil)
- Insulation & sheathElectron-beam cross-linked halogen-free elastomer (PV1-F); 90 °C wet/dry sunlight-resistant XLPE (UL 4703)
- Special constructionsTwin figure-8 parallel core (DUO PV) & stainless-steel wire braid rodent/termite armor (DUO PV-S)
- Thermal & cold rating-40 °C to +90 °C ambient (+120 °C max conductor on PV1-F; 90 °C wet/dry & -40 °C cold impact on UL 4703)
- Flame & burial complianceIEC 60332-1-2, EN 60754-1/2 halogen-free (PV1-F); UL 1685 / VW-1 & UL 854 direct burial (UL 4703)
PV1-F High-Temperature Wire Identification
- Type: EV Charging & Solar Cable
- Model designations: PV1-F, Dual-Rated PV1-F / UL 4703, Twin DUO PV (+S Rodent Braid), 49-Strand Cu PV & AA-8000 Al PV
- Reference standards: 2 PfG 1169/08.2007 (PV1-F), UL 4703 (PV Wire), UL 854 (USE-2), UL 44 (RHH/RHW-2), NEC Art. 690
- Rated voltage: 0.6/1 kV AC / 1.8 kV DC max (PV1-F); 600 V, 1000 V & 2000 V (UL 4703 Cu & AA-8000 Al
Continuous Thermal, Dielectric & AWG Ratings
- Conductors: Class 5 tinned Cu (PV1-F); 7/19/37/49/61-str Cu (UL 4703); Compact AA-8000 Al (8 AWG–1000 kcmil
- Insulation & sheath: Electron-beam cross-linked halogen-free elastomer (PV1-F); 90 °C wet/dry sunlight-resistant XLPE (UL 4703
- Special constructions: Twin figure-8 parallel core (DUO PV) & stainless-steel wire braid rodent/termite armor (DUO PV-S
- Thermal & cold rating: -40 °C to +90 °C ambient (+120 °C max conductor on PV1-F; 90 °C wet/dry & -40 °C cold impact on UL 4703
- Flame & burial compliance: IEC 60332-1-2, EN 60754-1/2 halogen-free (PV1-F); UL 1685 / VW-1 & UL 854 direct burial (UL 4703
PV1-F Plated Conductor & Fluoropolymer/Silicone Build
From Class 5 tinned copper electron-beam cross-linked string cables to 1000 kcmil AA-8000 aluminum 2000V direct-burial DC feeders, each construction is engineered for 25–30+ year outdoor UV and moisture survival.
- Conductor: PV1-F & DUO PV: Class 5 flexible tinned copper (IEC 60228). UL 4703 Cu: 7/19/37/49/61-strand bare or tinned copper. UL 4703 Al: compact AA-8000 series aluminum alloy (ASTM B800/B801/B836).
- Insulation & Jacket: PV1-F: dual-layer electron-beam cross-linked halogen-free polyolefin elastomer (-40 °C to +120 °C). UL 4703: heavy single-layer sunlight-resistant 90 °C wet/dry XLPE (-40 °C cold impact).
- Twin Parallel & Rodent Armor (DUO PV): Two parallel insulated cores connected by a tear-web (DUO PV), optionally over-braided with corrosion-proof stainless-steel wire armor (DUO PV-S).
- Outer Jacket & Polarity Web: Electron-beam cross-linked halogen-free UV/ozone-resistant polyolefin (PV1-F) or sunlight-resistant XLPE (UL 4703), with tear-apart web on Twin Solar.
Thermal Endurance, Outgassing & Dielectric Stability
- Dual-rated PV1-F & UL 4703 global string wire: Satisfies both European 2 PfG 1169 (0.6/1 kV AC / 1.8 kV DC) and North American UL 4703 (600V/1000V/2000V RHW-2) on a single reel for export OEMs.
- Twin Parallel & Stainless-Steel Rodent Armor: Figure-8 twin parallel cores (2×4.0–2×10 mm²) halve string pulling time; optional stainless-steel wire braid protects against rodent and termite attack.
- 49-Strand 10 AWG & 8 AWG tracker-flex copper: 49-strand copper UL 4703 2kV PV Wire (vs standard 7- or 19-strand) withstands daily torsional flexing across single-axis solar tracker torque tubes.
- 1kV/2kV AA-8000 Aluminum PV / USE-2 / RHW-2: Compacted 8000-series aluminum (8 AWG to 1000 kcmil) with 85–135 mil 90 °C wet/dry XLPE cuts DC feeder conductor cost by 50%+ for direct-buried trenches.
Chemical, Solvent, Flame & Cryogenic Resistance
- Electron-beam cross-linked 120 °C elastomer: PV1-F and Dual-Rated PV1-F/UL 4703 insulation resists thermal softening, solder-iron contact, ozone, UV radiation, and ammonia/acidic soils.
- UL 854 Grade 2 Direct Burial (DIR-BUR GR2): Both Copper and AA-8000 Aluminum UL 4703 1kV/2kV cables pass UL 854 impact and crushing tests for direct trench burial without conduit.
- CT Use (Cable Tray) rated from 1/0 AWG up: Sizes 1/0 AWG through 1000 kcmil pass UL 1685 (70,000 Btu/hr) vertical tray flame testing for open ladder tray installation.
- Color-coded polarity identification: Available in Black, Red, White, Yellow, Green, Brown, Orange, and Gray (or dual Red/Blue tracer rings on Twin DUO PV).
UL 758 AWM / CSA / Aerospace & Furnace Standards
- 2 PfG 1169/08.2007: PV1-F 0.6/1 kV AC / 1.8 kV DC max halogen-free cross-linked photovoltaic cable
- UL 4703: Standard for Photovoltaic Wire — 600 V, 1000 V and 2000 V copper and AA-8000 aluminum
- UL 854: Type USE-2 Direct Burial) & UL 44 (Type RHH / RHW-2 90 °C wet or dry thermoset wire
- NFPA 70 NEC Article 690: Solar Photovoltaic Systems — unenclosed outdoor, raceway, tray and direct burial
High-Temperature & Fluoropolymer Wire Guides
- 1500 V DC BESS Battery Energy Storage Cable Guide: Stranding, LSZH Standards & Busbar Sizing
- PV1-F / Dual-Rated String Leads, 1500 V DC Aluminum PV Al Collector Feeders, NF M 87-202 (EGFA / EIFA / EGPF) Acid-Tank and VDE 6Y / 5Y Bath Engineering Guide
- H1Z2Z2-K, EN 50618, IEC 62930 and UL 4703 Solar PV Cable Guide

PV1-F Thermal Zone & Internal Equipment Wiring
Global photovoltaic EPCs, solar module OEMs, and single-axis tracker manufacturers frequently require solar DC cables that bridge European 2 PfG 1169/08.2007 (PV1-F) and North American UL 4703 (Type PV Wire), UL 854 (USE-2), and UL 44 (RHH / RHW-2) electrical codes. Our PV1-F (1×1.5 mm² to 1×240 mm²) and Dual-Rated PV1-F / UL 4703 Tinned Copper Solar Cable (2.5 mm² / 14 AWG to 120 mm² / 4/0 AWG) combine IEC 60228 Class 5 flexible tinned copper stranding with dual-layer electron-beam cross-linked halogen-free insulation and sheathing (-40 °C to +120 °C max conductor temperature, 1.8 kV DC max). To cut string installation labor by 40% and prevent grassland rodent damage, the Twin Parallel Solar Cable (DUO PV, 2×4.0, 2×6.0, 2×10.0 mm²) bonds positive (red-ringed) and negative (blue-ringed) cores in a zip-separable figure-8 profile—available with a brushed stainless-steel wire braid (DUO PV-S) that stops gopher, rat, and termite chewing on ground-mount arrays. Compare with our EN 50618H1Z2Z2-K 1500V DC Solar PV Cableand1500V DC Floating Solar PV Cable.
For North American NEC Article 690 utility-scale solar farms, we supply both UL 4703 600V / 1000V / 2000V Copper PV Wire (14 AWG through 1000 kcmil, including ultra-flexible 49-strand 10 AWG & 8 AWG for moving solar trackers) and UL 4703 / USE-2 / RHH / RHW-2 1000V & 2000V Compacted AA-8000 Aluminum Solar Feeder Cable (8 AWG through 1000 kcmil). Insulated with thick single-layer sunlight-resistant 90 °C wet/dry -40 °C XLPE (75 to 135 mils), these cables are rated for unenclosed rooftop/tracker string routing, cable trays (1/0 AWG and larger), underground ducts, and direct burial (DIR-BUR GR2). For European IEC 60502-1 aluminum DC collector cables, comparePV Al 1500 V DC Aluminum Solar Feeder Cable.
Furnaces, Ovens, Avionics & Cleanroom Assemblies
- Module Stringing, Single-Axis Trackers & Rooftop Arrays (PV1-F, Dual-Rated PV1-F / UL 4703, Twin DUO PV & 49-Strand Cu PV Wire): Interconnects photovoltaic strings to combiner boxes or string inverters in fixed-tilt, single-axis tracker, commercial rooftop, and rodent-prone agricultural solar parks.
- Combiner-Box-to-Central-Inverter DC Trunk Trenches (UL 4703 1kV/2kV Copper & AA-8000 Aluminum 1/0 AWG–1000 kcmil): Direct-buried, duct-pulled, or cable-tray-mounted 1,000 V / 1,500 V / 2,000 V DC collector feeders.
PV1-F Thermal Rating & Stripping FAQ
How does Dual-Rated PV1-F / UL 4703 simplify solar module and harness manufacturing?
Solar skid, combiner, and harness manufacturers exporting to both Europe/IEC markets and North America/NEC markets can stock a single dual-marked cable that complies simultaneously with 2 PfG 1169 (PV1-F 1.8 kV DC max) and UL 4703 (Type PV Wire 600V/1000V/2000V RHW-2).
Why use 49-strand 10 AWG or 8 AWG Copper UL 4703 PV Wire instead of standard 7- or 19-strand?
Single-axis solar trackers rotate +/-60 degrees every day. Standard 7-strand or 19-strand XLPE wire is stiffer and can fatigue at tracker pivot points in -40 °C winter winds, whereas 49-strand copper provides rope-lay flexibility for moving tracker harnesses.
Why does UL 4703 Aluminum PV Wire use AA-8000 series aluminum alloy instead of 1350 series?
Under NEC Article 310 and Article 690, AA-8000 series aluminum alloy (ASTM B800) provides superior creep resistance and thermal stability at bolted inverter/combiner lugs compared to EC-1350 aluminum, and is dual-rated as UL 4703 PV Wire, UL 854 USE-2, and UL 44 RHH/RHW-2.
When should Twin Parallel Stainless-Steel Braided (DUO PV-S) solar cable be specified?
In rural, desert, and agricultural ground-mount solar plants, rodents (rats, mice, gophers, marmots) chew exposed polymer string cables under solar panels. The outer stainless-steel wire braid on DUO PV-S prevents rodent teeth from penetrating the 1.5 kV DC insulation.
Dimensional, stranding, insulation wall, weight and ampacity tables for PV1-F & Dual-Rated PV1-F / UL 4703 tinned copper cables (1.5–240 mm²), Twin Parallel DUO PV cables, and UL 4703 1kV/2kV Cu & AA-8000 Al PV / USE-2 / RHW-2 cables (14 AWG–1000 kcmil).
TEBAOFLEX® — PV1-F, Dual-Rated PV1-F / UL 4703 (Cu & Al) & Twin Parallel Solar PV Cable
| Cable Type | Size (mm² / AWG) | Conductor Stranding | Insulation / Sheath (mm) | Nominal OD (mm) | Approx. Weight (kg/km) | Max. DC Res. 20 °C (Ω/km) | Ampacity in Air at 60 °C (A) |
|---|---|---|---|---|---|---|---|
| PV1-F / Dual UL 4703 | 1 × 2.5 mm² (14 AWG) | Class 5 Tinned Cu (50×0.25) | 0.7 / 0.8 XLPO | 5.2 | 48 | 8.21 | 41 |
| PV1-F / Dual UL 4703 | 1 × 4.0 mm² (12 AWG) | Class 5 Tinned Cu (56×0.30) | 0.7 / 0.8 XLPO | 5.6 | 62 | 5.09 | 55 |
| PV1-F / Dual UL 4703 | 1 × 6.0 mm² (10 AWG) | Class 5 Tinned Cu (84×0.30) | 0.7 / 0.8 XLPO | 6.2 | 82 | 3.39 | 70 |
| PV1-F / Dual UL 4703 | 1 × 10 mm² (8 AWG) | Class 5 Tinned Cu (80×0.40) | 0.7 / 0.8 XLPO | 7.4 | 128 | 1.95 | 98 |
| PV1-F / Dual UL 4703 | 1 × 16 mm² (6 AWG) | Class 5 Tinned Cu (126×0.40) | 0.7 / 0.9 XLPO | 9.0 | 195 | 1.24 | 132 |
| PV1-F / Dual UL 4703 | 1 × 35 mm² (2 AWG) | Class 5 Tinned Cu (276×0.40) | 0.9 / 1.1 XLPO | 12.5 | 405 | 0.565 | 218 |
| PV1-F / Dual UL 4703 | 1 × 70 mm² (2/0 AWG) | Class 5 Tinned Cu (356×0.50) | 1.1 / 1.3 XLPO | 16.8 | 765 | 0.277 | 340 |
| PV1-F / Dual UL 4703 | 1 × 120 mm² (4/0 AWG) | Class 5 Tinned Cu (608×0.50) | 1.2 / 1.5 XLPO | 21.2 | 1,260 | 0.164 | 480 |
| Twin Parallel DUO PV | 2 × 4.0 mm² | Class 5 Tinned Cu | 0.7 / 0.8 XLPO | 5.6 × 11.6 | 126 | 5.09 | 52 |
| Twin Parallel DUO PV | 2 × 6.0 mm² | Class 5 Tinned Cu | 0.7 / 0.8 XLPO | 6.2 × 12.8 | 166 | 3.39 | 67 |
| Twin Rodent DUO PV-S | 2 × 6.0 mm² + SS Braid | Class 5 Tinned Cu + SS Braid | 0.7 / 1.0 + Braid | 7.6 × 15.2 | 245 | 3.39 | 65 |
TEBAOFLEX® — PV1-F, Dual-Rated PV1-F / UL 4703 (Cu & Al) & Twin Parallel Solar PV Cable
| Conductor Metal & Rating | Size (AWG / kcmil) | No. of Strands | XLPE Wall (in / mm) | Outside Diameter (in / mm) | Net Weight (lbs/kft / kg/km) | NEC 90 °C Ampacity (A) |
|---|---|---|---|---|---|---|
| UL 4703 1kV/2kV Copper PV | 10 AWG Cu | 19 Strands | 0.075 / 1.91 | 0.263 / 6.68 | 49 / 73 | 40 |
| UL 4703 1kV/2kV Copper PV | 8 AWG Cu (Standard) | 7 Strands | 0.085 / 2.16 | 0.316 / 8.03 | 78 / 116 | 55 |
| UL 4703 2kV Tracker-Flex Cu | 8 AWG Cu (High-Flex) | 49 Strands | 0.087 / 2.20 | 0.317 / 8.05 | 82 / 122 | 55 |
| UL 4703 1kV/2kV Copper PV | 6 AWG Cu | 7 Strands | 0.085 / 2.16 | 0.354 / 8.99 | 113 / 168 | 75 |
| UL 4703 1kV/2kV Copper PV | 2 AWG Cu | 7 Strands | 0.085 / 2.16 | 0.462 / 11.73 | 249 / 371 | 130 |
| UL 4703 1kV/2kV Copper PV | 4/0 AWG Cu | 19 Strands | 0.105 / 2.67 | 0.720 / 18.29 | 742 / 1,104 | 260 |
| UL 4703 1kV/2kV Copper PV | 500 kcmil Cu | 37 Strands | 0.120 / 3.05 | 1.006 / 25.55 | 1,694 / 2,521 | 430 |
| UL 4703 1kV/2kV AA-8000 Al | 6 AWG Al | 7 Compact | 0.085 / 2.16 | 0.339 / 8.61 | 54 / 80 | 55 |
| UL 4703 1kV/2kV AA-8000 Al | 2 AWG Al | 7 Compact | 0.085 / 2.16 | 0.438 / 11.13 | 104 / 155 | 100 |
| UL 4703 1kV/2kV AA-8000 Al | 1/0 AWG Al | 7 Compact | 0.105 / 2.67 | 0.546 / 13.87 | 163 / 243 | 135 |
| UL 4703 1kV/2kV AA-8000 Al | 4/0 AWG Al | 19 Compact | 0.105 / 2.67 | 0.685 / 17.40 | 283 / 421 | 205 |
| UL 4703 1kV/2kV AA-8000 Al | 350 kcmil Al | 24 Compact | 0.120 / 3.05 | 0.856 / 21.74 | 451 / 671 | 280 |
| UL 4703 1kV/2kV AA-8000 Al | 500 kcmil Al | 34 Compact | 0.120 / 3.05 | 0.976 / 24.79 | 612 / 911 | 350 |
| UL 4703 1kV/2kV AA-8000 Al | 750 kcmil Al | 47 Compact | 0.135 / 3.43 | 1.178 / 29.92 | 900 / 1,339 | 435 |
| UL 4703 1kV/2kV AA-8000 Al | 1000 kcmil Al | 61 Compact | 0.135 / 3.43 | 1.330 / 33.78 | 1,163 / 1,731 | 500 |
Selection guide: Specify PV1-F, Dual-Rated PV1-F / UL 4703 (tinned copper), Twin Parallel DUO PV (with or without stainless-steel rodent braid), 49-Strand Tracker Copper PV Wire, or 1kV/2kV AA-8000 Aluminum UL 4703 / USE-2 / RHW-2.
Ordering & Quotation Checklist: Request a factory quotation for PV1-F, Dual-Rated PV1-F / UL 4703, Twin Parallel Rodent-Protected DUO PV, 49-Strand Copper PV Wire, or 1kV/2kV AA-8000 Aluminum UL 4703 solar cables.
1500 V DC Floating Solar PV Cable
Floating photovoltaic string and collection connections on waters and reservoirs, with a defined wet-route ins
1500 V DC Aluminum Solar PV Feeder Cable: PV Al, LSZH, Heavy-Duty & AWA/SWA
PV Al 1500 V, PV LSZH Al 1500 V, PV Al Heavy Duty & PV AWA/SWA Al 1500 V
1500 V DC Battery Energy Storage System (ESS) Flexible Single-Core Power Cable
1500 V DC (1800 V DC max)
Request Quotation & Datasheet for This Cable
Need factory pricing, cross-section drawing or a full PDF datasheet for PV1-F, Dual-Rated PV1-F / UL 4703 (Cu & Al) & Twin Parallel Solar PV Cable? Share your core count, conductor size, length and destination country—our Taicang cable engineers reply within 24 hours.
- ISO 9001 Factory Direct
- MOQ 50 m (Custom Builds)
- 24h Engineering Reply