MGM-101 to MGM-120 Series (MGM-101, MGM-109, MGM-112, MGM-115 & MGM-118) Complete Engineering Selection Guide
Complete colliery cable engineering guide across MGM 101–120 and BS 6708 families: SWA shaft feeders (MGM 109/118), pliable wire armored gate-end cables (MGM 112), and shearer trailing cables (MGM 115).

- Colliery Scope
- 110 V Signal · 500 V Lamp · 0.6/1–6.6 kV
- Armour Progression
- Fixed SWA (109/118) vs. Flexible PWA (112)
- Face Cutter Types
- MGM 115 Types 7, 7M, 7S, 11, 14 & 16
- Outer & Earth Barrier
- PCP / Heavy-Duty Neoprene | Pilot & Earth
Roadway vs. Gate-End
MGM 109/118 SWA vs. MGM 111/112 PWA
Fixed shaft trunks use SWA (3.3–6.6 kV); advancing gate-end switchboards require Pliable Wire Armour (PWA).
Face Cutter Protection
Decoding MGM 115 Types 7 to 16
Match phase screen geometry (Cu/nylon composite vs. semi-conductive vs. 3.3 kV collective screens) directly to earth-fault relays.
Across UK National Coal Board (NCB / British Coal), Commonwealth underground collieries, potash shafts, and hard-rock extraction galleries, electrical engineers specify the MGM 101 to MGM 118 cable series. These constructions are governed by BS 6708, BS 2980, NCB Specification 188 / 295 / 492 / 504 / 505, AS/NZS 1802 / 1972, and SANS 1520 / 1507. Voltage ratings span from 110 V intrinsically safe signalling and 500 V cap-lamp cords to 0.6/1 kV and 660/1100 V low-voltage runs. Higher-power roadway and face circuits operate at 1.9/3.3 kV and 3.8/6.6 kV. This guide builds on our YnOGY, YnOGYek, YnKGY and YKGYfOyn underground gallery cable guide and Type W, Type G-GC and SHD-GC portable power cable guide. Below we compare all twenty specialized product families in our mining and tunnelling cable portfolio.
Related Engineering & Product Scope
For personnel lighting and roadway telephony, engineers specify MGM 101 500 V headcap lamp cables and MGM 110 110 V armoured telephone and signal cables. Roadway transformer feeders deploy MGM 109 Type 1012/1013/1014 0.6/1 kV single wire armoured cables and MGM 109 Type 3013 3.3 kV single armoured cables. Severe rock-fall galleries upgrade to MGM 109 Type 3023 3.3 kV unscreened double armoured cables and MGM 109 Type 3123 3.3 kV screened double armoured cables. Mobile transwitch links use MGM 111 Type 320/321 3.3 kV screened pliable wire armoured cables.
For semi-mobile gate-end box (GEB) interconnections (MGM 112), engineers deploy MGM 112 Type 201/211 660/1100 V screened armoured cables. Medium-voltage face conveyors use MGM 112 Type 331 3.3 kV screened armoured cables and MGM 112 Type 321 3.3 kV unscreened armoured cables. Auxiliary control circuits use MGM 112 Type 62/63/64 660/1100 V screened 4 mm² cables and MGM 112 Type E2/E4/E5 660/1100 V unscreened cables.
For dynamic coal-face shearers (MGM 115, BS 6708), engineers select MGM 115 Type 7 660/1100 V bare-earth cables and MGM 115 Type 7M 660/1100 V fully screened cables. Multi-motor shearers use MGM 115 Type 7S 660/1100 V 3-pilot cables. Loader and drill loops deploy MGM 115 Type 11 screened cables, MGM 115 Type 14 drill cables, and MGM 115 Type 16 two-earth cables. High-voltage 3.8/6.6 kV substations rely on MGM 118 Type 6020 double armoured cables and MGM 118 Type 6110 screened armoured cables.
1. Master Engineering Matrix Across All 20 MGM 101 to MGM 118 Colliery Cable Families
Table 1 summarizes the governing standards, voltage ratings, conductor/insulation architectures, screening/armour systems, and target underground applications across all twenty MGM product families.
| Family & Model Code | Governing Standards | Voltage Rating | Conductor & Insulation | Screen, Armour & Outer Covering | Primary Colliery Application |
|---|---|---|---|---|---|
| MGM 101 500V Cap-Lamp Cord (2×1 mm²) | BS 6708 / NCB Spec | 500 V | Class 5 Tinned Cu (2×1.0 mm²) + EPR | Unscreened + Polychloroprene (PCP / Neoprene) Heavy-Duty Outer Covering | Miner helmet cap lamps, belt battery packs, portable gas detectors |
| MGM 110 110V Armoured Telephone & Signal | NCB Spec 492 / BS 6708 | 110 V | Tinned Cu Pairs/Cores (0.75–1.5 mm²) + PE/PVC | Galvanized Steel Wire Armour (SWA) + Flame-Retardant PVC | Roadway emergency pull-key lockout, intrinsically safe (IS) intercoms & shaft bells |
| MGM 109 Type 1012 / 1013 / 1014 (0.6/1 kV SWA) | NCB Spec 295 / BS 6708 | 600/1000 V | 2C (1012), 3C (1013), or 4C (1014) Cu + PVC/EPR | Unscreened + Single Galvanized Steel Wire Armour (SWA, ≥50% conductance) + FR-PVC | Fixed underground roadway lighting, pump stations, auxiliary switchgear |
| MGM 109 Type 3013 (3.3 kV Single Armoured) | NCB Spec 295 / BS 6708 | 1.9/3.3 kV | 3-Core Stranded Cu (16–300 mm²) + EPR/XLPE | Unscreened + Single Layer Galvanized Steel Wire Armour (SWA, ≥50% earth conductance) + FR-PVC | Main intake roadway 3.3 kV feeders to district sub-stations |
| MGM 109 Type 3023 (3.3 kV Double Armoured) | NCB Spec 295 / BS 6708 | 1.9/3.3 kV | 3-Core Stranded Cu (16–300 mm²) + EPR/XLPE | Unscreened + Double Galvanized Steel Wire Armour (DWA) + Heavy FR-PVC | Vertical mine shafts, steep drift inclines, rock-burst-prone return roadways |
| MGM 109 Type 3123 (3.3 kV Screened Double Armoured) | NCB Spec 295 / BS 6708 | 1.9/3.3 kV | 3-Core Stranded Cu + EPR + Individual Metallic Screen | Individual Cu Tape/Wire Phase Screens + Double Galvanized Steel Wire Armour (DWA) + FR-PVC | High-fault-level 3.3 kV gassy coal seams requiring sensitive earth-leakage tripping |
| MGM 111 Type 320 / Type 321 (3.3 kV Screened PWA) | BS 6708 / NCB 504 | 1.9/3.3 kV | Flexible Tinned Cu (3C Type 320 or 3C+1Pilot Type 321) + EPR | Individual Cu/Nylon Phase Screens + Pliable Wire Armour (PWA) + Heavy PCP | Semi-flexible jumpers between 3.3 kV roadway cables and mobile transwitch units |
| MGM 112 Type 201 / Type 211 (660/1100 V Screened PWA) | BS 6708 / BS 2980 | 660/1100 V | 4-Core (3P+1E Type 201 or 3P+1E+1Pilot Type 211) Tinned Cu + EPR | Individual Cu/Nylon Phase Screens + Pliable Wire Armour (PWA) + PCP | Gate-end box (GEB) inter-coupling, stage loader & armoured face conveyor (AFC) drives |
| MGM 112 Type 331 (3.3 kV Screened Armoured) | BS 6708 | 1.9/3.3 kV | 4-Core (3P+1E or 3P+1Pilot) Flexible Tinned Cu + EPR | Individual Phase Screens + Pliable Galvanized Steel Wire Braid/Armour (PWA) + PCP | 3.3 kV coal-face AFC motors, lump breakers, and high-power pump packs |
| MGM 112 Type 321 (3.3 kV Unscreened Armoured) | BS 6708 | 1.9/3.3 kV | 4-Core (3P+1E) Flexible Tinned Cu + EPR | Collective Pliable Wire Armour (PWA, ≥50% conductance) + Heavy PCP | 3.3 kV semi-portable roadway equipment and feeder extensions |
| MGM 112 Type 62 / 63 / 64 (660/1100 V 4 mm² Screened) | BS 6708 / NCB 188 | 660/1100 V | 2C (Type 62), 3C (Type 63), or 4C (Type 64) 4 mm² Tinned Cu + EPR | Individual Phase Screens + Pliable Wire Armour (PWA) + PCP | Underground coal-face lighting, remote pilot interlocking, methane monitoring |
| MGM 112 Type E2 / E4 / E5 (660/1100 V Unscreened PWA) | BS 6708 | 660/1100 V | 2-Core (E2), 4-Core (E4), or 5-Core (E5) Tinned Cu + EPR | Unscreened Cores + Pliable Galvanized Steel Wire Armour (PWA) + PCP | Auxiliary control loops, remote start/stop pushbuttons, conveyor sequence switches |
| MGM 115 Type 7 (660/1100 V Bare Earth Core) | BS 6708 | 660/1100 V | 3 Phase + 1 Pilot + 1 Bare Central Earth (16–95 mm²) + EPR | Tinned Cu/Nylon Composite Screen on Each Power Core + Extra-Heavy PCP | Coal shearers, continuous miners, roadheaders, and mobile loader supply |
| MGM 115 Type 7M (660/1100 V Fully Screened) | BS 6708 | 660/1100 V | 3 Phase + 1 Pilot + 1 Bare Earth + EPR + Conductive Cradle | Individual Cu/Nylon Phase Screens + Overall Pliable/Conductive Screen + PCP | High-risk gassy faces requiring instantaneous crush/penetration earth-fault trip |
| MGM 115 Type 7S (660/1100 V 3-Core Pilot) | BS 6708 | 660/1100 V | 3 Phase + 3 Pilot Cores + Bare Earth + EPR | Individual Cu/Nylon Phase Screens + Heavy PCP | Multi-motor coal-face machines requiring independent pilot/temperature monitoring |
| MGM 115 Type 11 (660/1100 V 3×16+16 mm²) | BS 6708 | 660/1100 V | 3 Phase + 1 Earth + 1 Central Pilot (16–35 mm²) + EPR | Individual Tinned Cu/Nylon Phase Screens + Heavy PCP | Medium-duty cutter-loaders, gathering-arm loaders, roof bolting rigs |
| MGM 115 Type 14 (660/1100 V Drilling Machine) | BS 6708 | 660/1100 V | 3 Phase + 1 Earth + 1 Pilot (4–6 mm², 45 mm Short Lay) + EPR | Individual Cu/Nylon Phase Screens + Flexible Abrasion-Resistant PCP | Hand-held and rig-mounted rotary coal and stone drilling machines |
| MGM 115 Type 16 (660/1100 V Two Earth Cores) | BS 6708 | 660/1100 V | 3 Phase + 2 Interstitial Earths + 1 Central Pilot (16–70 mm²) + EPR | Individual Cu/Nylon Phase Screens + Heavy PCP | Symmetrical earth-impedance face machinery and mobile haulage units |
| MGM 118 Type 6020 (3.8/6.6 kV Double Armoured) | BS 6708 / NCB 505 | 3.8/6.6 kV | 3-Core Stranded Cu (25–300 mm²) + EPR/XLPE | Collective Screen + Double Galvanized Steel Wire Armour (DWA) + Heavy FR-PVC | Primary 6.6 kV shaft down-droppers and main trunk roadway feeders |
| MGM 118 Type 6110 (3.8/6.6 kV Screened Armoured) | BS 6708 / NCB 505 | 3.8/6.6 kV | 3-Core Stranded Cu (25–300 mm²) + EPR/XLPE | Individual Cu Tape/Wire Phase Screens + Galvanized Steel Wire Armour + FR-PVC | 6.6 kV radially screened underground trunk feeders to face transformers |
Sources: BS 6708, NCB Specification 188 / 295 / 504 / 505, BS 5467, and IEC 60228.
2. Fixed Roadway & Vertical Shaft Distribution: MGM 109 (Types 1012–3123) and MGM 118 (Types 6020 & 6110)
Use galvanized steel wire armoured MGM 109 (up to 3.3 kV) and MGM 118 (6.6 kV) for permanent colliery roadways, vertical shafts, and flameproof switchgear feeders.
2.1 Single vs. Double Galvanized Steel Wire Armour (SWA vs. DWA) and ≥50% Armour Conductance
In underground coal and potash mines governed by UK Mines and Quarries regulations (NCB Spec 295 / 505 and BS 6708), the metallic wire armour is not merely a mechanical shield. It serves as the primary earth-fault return path and must exhibit a DC conductance equal to at least 50% of the largest phase conductor within the cable. On large cross-sections (150–300 mm²), standard galvanized steel wires (GSW) alone cannot reach the 50% conductance threshold. Manufacturers therefore substitute a calculated number of tinned hard-drawn copper wires directly into the armour layer.
In horizontal roadways with stable roof support, engineers specify single-wire-armoured MGM 109 Type 1012/1013/1014 (0.6/1 kV) and MGM 109 Type 3013 (1.9/3.3 kV). In vertical mine shafts, steep drift haulages (>15°), and roadways subject to roof convergence or rock falls, double-wire-armoured (DWA) constructions are mandatory. Two counter-helical steel wire layers eliminate torsional twist under vertical suspension. Specify MGM 109 Type 3023 (3.3 kV unscreened DWA) or MGM 118 Type 6020 (3.8/6.6 kV DWA).
2.2 Individually Screened Phase Cores (Type 3123 & Type 6110) for Restricted Earth-Fault Systems
Phase-to-phase short circuits can ignite methane (CH4 Firedamp) in gassy collieries. Every radial fault must therefore become an earth fault first so restricted earth-leakage (REL) protection trips within < 80–100 ms. Both MGM 109 Type 3123 (3.3 kV screened DWA) and MGM 118 Type 6110 (3.8/6.6 kV screened) wrap each phase core in a semi-conductive screen. An individual copper tape or composite metallic screen contacts the earth system directly.

3. Pliable Wire Armoured (PWA) Gate-End & Conveyor Cables: MGM 111 & MGM 112 Series
Select pliable wire armoured (PWA) MGM 111 and MGM 112 where gate-end boxes, stage loaders, and armored face conveyors advance periodically without continuous drum reeling.
3.1 Why Pliable Wire Armour (PWA) Replaces Rigid SWA Near the Extraction Face
In advancing extraction panels, the district transformer, gate-end boxes (GEB), stage loader, and armoured face conveyor (AFC) drives sit on rail bogies (pantechnicons). These skids move forward every few days. Rigid single-wire armour (SWA) cracks or birdcages when coiled repeatedly around a 10 × OD storage loop.
The MGM 111 and MGM 112 families replace rigid single wires with Pliable Wire Armour (PWA). Multi-wire galvanized steel rope strands (7-wire or 19-wire) are laid helically over a polychloroprene inner bedding. They pair with Class 5 flexible tinned copper conductors and oil-resistant polychloroprene (PCP) outer coverings (BS 6708 / BS 2980).
– 3.3 kV Semi-Flexible Interconnections: Use MGM 111 Type 320 / Type 321 (3.3 kV screened PWA) for mobile transwitch jumpers. Specify MGM 112 Type 331 (3.3 kV screened PWA) and MGM 112 Type 321 (3.3 kV unscreened PWA) for 3.3 kV AFC motors and crushers.
– 660/1100 V Gate-End Power & Pilot Control: Specify MGM 112 Type 201 / Type 211 (660/1100 V screened PWA) for main power. Use MGM 112 Type 62 / 63 / 64 (4 mm² screened PWA) for face lighting and MGM 112 Type E2 / E4 / E5 (unscreened PWA) for sequence switches.
4. Dynamic Face-Cutter, Drill & Personnel Cables: MGM 115 (Types 7, 7M, 7S, 11, 14, 16), MGM 101 & MGM 110
Specify cradle-centered, elastomeric-screened MGM 115 trailing cables (Types 7–16) for shearers and roadheaders, paired with MGM 101 cap-lamp and MGM 110 drill cords.
4.1 Copper/Nylon Composite Phase Screens & Conductive Rubber Cradle Architecture (BS 6708)
Coal-face shearers, continuous miners, and rotary rock drills drag unarmoured elastomeric cables directly across abrasive rock floors and steel cable-handler chains (Bretby chains). To prevent open sparking under rock crush, MGM 115 cables (BS 6708) enclose each EPR power core inside a flexible composite screen. Tinned copper strands and nylon yarns are woven at opposing angles. If a sharp object penetrates the polychloroprene (PCP) outer covering, it contacts the grounded copper-nylon phase screen before reaching the live conductor, tripping the gate-end earth-leakage relay instantaneously.
4.2 Selecting Between MGM 115 Type 7, Type 7M, Type 7S, Type 11, Type 14, and Type 16
Table 2 details the exact structural differences across all six MGM 115 660/1100 V designs.
| BS 6708 / MGM 115 Type | Power & Pilot Core Layout | Earth Conductor Configuration | Phase & Overall Screening | Lay Pitch & Target Face Machine |
|---|---|---|---|---|
| MGM 115 Type 7 | 3 Power + 1 Pilot (16–95 mm²) | 1 Uninsulated (Bare) Tinned Cu Central Earth in Conductive Rubber Cradle | Individual Cu/Nylon Composite Screen on 3 Power Cores | Standard Lay — Double-ended ranging drum shearers & roadheaders |
| MGM 115 Type 7M | 3 Power + 1 Pilot (16–95 mm²) | 1 Bare Central Earth in Conductive Cradle + Overall Screen | Individual Cu/Nylon Phase Screens + Overall Pliable/Conductive Screen | Standard Lay — Heavy-duty coal-face shearers in high-methane seams |
| MGM 115 Type 7S | 3 Power + 3 Pilot Cores (16–95 mm²) | 1 Bare Central Earth in Conductive Rubber Cradle | Individual Cu/Nylon Composite Screen on 3 Power Cores | Standard Lay — Multi-motor shearers with dual pilot/thermistor interlocks |
| MGM 115 Type 11 | 3 Power + 1 Central Pilot (16–35 mm²) | 1 Insulated/Screened Earth Core Laid Up with Power Cores | Individual Cu/Nylon Composite Screen on Power & Earth Cores | Medium Lay — Gathering-arm loaders, shuttle cars, roof bolters |
| MGM 115 Type 14 | 3 Power + 1 Pilot (4–6 mm²) | 1 Earth Core Laid Around Central Conductive Rubber Cradle | Individual Cu/Nylon Phase Screens | Ultra-Short Lay (45 mm) — Hand-held & boom-mounted rotary drills |
| MGM 115 Type 16 | 3 Power + 1 Central Pilot (16–70 mm²) | 2 Split Interstitial Earth Cores in Outer Valleys | Individual Cu/Nylon Composite Screen on 3 Power Cores | Standard Lay — Balanced earth-impedance haulage & cutter-loaders |
Sources: BS 6708:1998 flexible trailing cables for use at mines and quarries.
4.3 Personnel Cap-Lamp (MGM 101) and Roadway Emergency Signalling (MGM 110)
Every underground worker carries a belt-pack battery connected to a helmet lamp via MGM 101 500 V headcap lamp cable (2×1 mm²). It uses extra-fine tinned copper strands, a central strain-relief cord, and sweat-resistant polychloroprene that withstands > 100,000 flex cycles. Along conveyor roadways, MGM 110 110 V armoured telephone and signal cables link pull-wire emergency stop keys, acoustic pre-start warning hooters, and intrinsically safe (Ex ia) mine telephones.

5. Electrical Parameters, Earth-Fault Conductance & Restrained Plug Selection
Verify phase DC resistance, minimum metallic or elastomeric earth-fault conductance, and restrained BS 5620 plug gland entry diameter before procurement.
5.1 Conductor Cross-Sections, Outer Dimensions & Armour Resistance (MGM 109 / 112 / 115 / 118)
When matching colliery cables to BS 5620 bolted couplers or BS 3905 restrained plugs (100–400 A), verify the nominal outer dimension and maximum DC resistance (IEC 60228).
| Model & Voltage Class | Core Configuration | Nominal OD Range (mm) | Max Phase DC Resistance at 20 °C (Ω/km) | Min Armour / Screen Earth Conductance | Compatible Flameproof Coupler / Gland |
|---|---|---|---|---|---|
| MGM 101 (500 V Cap Lamp) | 2 × 1.0 mm² Class 5 Tinned Cu | 7.8 – 8.6 mm | 19.5 Ω/km | N/A (Double Insulated Battery Loop) | Cap-Lamp Cord Grip & Helmet Gland |
| MGM 110 (110 V Signal SWA) | 2C to 20Pr × 0.75 / 1.5 mm² | 12.5 – 28.0 mm | 26.0 / 13.6 Ω/km | ≥ 50% of Phase Core via SWA | Flameproof Ex d SWA Signal Gland |
| MGM 109 Type 1013 (0.6/1 kV) | 3 × 35 mm² to 3 × 185 mm² | 26.5 – 52.0 mm | 0.524 – 0.0991 Ω/km | ≥ 50% via SWA (+ Cu Wires if req.) | BS 542 / Ex d Roadway Cable Box |
| MGM 109 Type 3123 (3.3 kV) | 3 × 50 mm² to 3 × 240 mm² | 38.0 – 66.5 mm | 0.387 – 0.0754 Ω/km | ≥ 50% via Phase Screens + DWA | 3.3 kV 300 A / 400 A Bolted FLP Coupler |
| MGM 112 Type 201 (660/1100 V) | 4 × 16 mm² to 4 × 120 mm² | 28.5 – 56.0 mm | 1.24 – 0.164 Ω/km | ≥ 50% via Dedicated Earth + PWA | BS 5620 200 A / 300 A GEB Flit-Plug |
| MGM 115 Type 7 / 7M (1.1 kV) | 3 × 35 + 1P + 1E to 3 × 95 mm² | 39.5 – 58.0 mm | 0.565 – 0.210 Ω/km | Central Bare Earth (≥50%) + Cu/Nylon | BS 3905 200 A / 300 A Restrained Plug |
| MGM 115 Type 14 (1.1 kV Drill) | 3 × 4.0 + 1E + 1P (45 mm Lay) | 21.5 – 24.0 mm | 5.09 Ω/km | Dedicated Earth Core + Phase Screens | 30 A Flameproof Drill Restrained Plug |
| MGM 118 Type 6110 (3.8/6.6 kV) | 3 × 35 mm² to 3 × 240 mm² | 46.0 – 76.0 mm | 0.524 – 0.0754 Ω/km | ≥ 50% via Phase Screens + SWA/DWA | 6.6 kV 400 A Flameproof Bolted Coupler |
Sources: BS 6708, IEC 60228 Class 5 tinned copper resistance limits, and BS 5620 / BS 3905 coupler practice.

6. Frequently Asked Questions (FAQ)
What is the difference between MGM 115 Type 7, Type 7M, Type 7S, Type 11, and Type 16 under BS 6708?
All five are 660/1100 V EPR-insulated, PCP-covered face cables under BS 6708 with composite copper/nylon phase screens, differing in earth and pilot layout. MGM 115 Type 7 places an uninsulated tinned copper earth conductor at the center of a semi-conductive rubber cradle with 3 power cores and 1 pilot core laid around it. MGM 115 Type 7M adds an overall metallic/conductive screen around the core assembly. MGM 115 Type 7S replaces the single pilot with 3 pilot cores for multi-motor shearers. MGM 115 Type 11 uses a central pilot with 3 power cores and 1 earth core. MGM 115 Type 16 pairs a central pilot with 2 split interstitial earth cores.
Why does MGM 115 Type 14 specify a 45 mm short core lay pitch?
Hand-held and rig-mounted rotary coal/stone drills subject the last 3–5 meters of cable to tight kinking and axial twisting right behind the drill entry gland. MGM 115 Type 14 uses an ultra-short 45 mm core lay pitch around a conductive rubber cradle. Tensile and torsional loads distribute evenly without corkscrewing or snapping the 4–6 mm² conductors.
When should engineers specify MGM 109 Type 3123 or MGM 118 Type 6110 over unscreened Type 3013 / Type 6020?
Unscreened MGM 109 Type 3013, MGM 109 Type 3023, and MGM 118 Type 6020 use outer armour for earth-fault return. In gassy coal seams, phase-screened MGM 109 Type 3123 and MGM 118 Type 6110 force any internal fault to earth first. This prevents phase-to-phase arcing and trips sensitive earth-fault relays immediately.
How does Pliable Wire Armour (PWA) in MGM 111 and MGM 112 differ from standard SWA?
Standard SWA uses solid single galvanized steel wires (1.6–3.15 mm diameter) intended for fixed cleats. Pliable Wire Armour (PWA) in MGM 111 Type 320/321 and MGM 112 Type 201/211/331 uses stranded steel wire ropes (7 × 0.4–0.7 mm). This allows semi-mobile gate-end box jumpers and armoured face conveyor feeders to be coiled, dragged on pantechnicon skids, and re-routed as the coal face advances without armour kinking.
7. Request Engineering Support & Factory Quotations
Our team supplies BS 6708 / NCB roadway feeders (MGM 109 & MGM 118), pliable wire armoured gate-end cables (MGM 111 & MGM 112), and composite-screened face cables (MGM 115 Types 7–16). We also manufacture MGM 101 cap-lamp cords and MGM 110 signalling cables with full BS 6708, IEC 60332-1-2, and 50% armour conductance test reports. Before ordering roadway or gate-end lengths, check three-phase feeder drop in our Voltage Drop Calculator, verify conductor resistance in the Wire Resistance Calculator, and check shaft-cage drum clearances with the Cable Drum Length Calculator. Explore our dedicated MGM armored and screened mining cable hub and complete mining and tunnelling cable portfolio, or contact our technical desk for project selection and factory pricing.
Engineering RFQ & Datasheet Review
Confirm BS 6708 / NCB Type Number, Voltage Class, and Coupler Gland Window
Specify your MGM model (MGM 101–120), BS 6708 Type number, voltage class (500 V to 6.6 kV), phase and pilot cross-sections, metallic vs elastomeric earth screen, and restrained coupler gland window.