MGM-101 to MGM-120 Series (MGM-101, MGM-109, MGM-112, MGM-115 & MGM-118) Complete Engineering Selection Guide

Complete colliery cable engineering guide across MGM 101–120 and BS 6708 families: SWA shaft feeders (MGM 109/118), pliable wire armored gate-end cables (MGM 112), and shearer trailing cables (MGM 115).

Engineering Selection Guide

Engineering Reference500 V TO 6.6 KV · BS 6708 / NCB
MGM 101 MGM 109 MGM 110 MGM 111 MGM 112 MGM 115 and MGM 118 colliery cable comparison
Three-panel overview comparing MGM 109 / MGM 118 galvanized steel wire armoured roadway feeders, MGM 111 / MGM 112 pliable wire armoured gate-end cables, and MGM 115 (Types 7, 7M, 7S, 11, 14, 16) screened extraction cables.
Colliery Scope
110 V Signal · 500 V Lamp · 0.6/1–6.6 kV
Armour Progression
Fixed SWA (109/118) vs. Flexible PWA (112)
Face Cutter Types
MGM 115 Types 7, 7M, 7S, 11, 14 & 16
Outer & Earth Barrier
PCP / Heavy-Duty Neoprene | Pilot & Earth

Roadway vs. Gate-End

MGM 109/118 SWA vs. MGM 111/112 PWA

Fixed shaft trunks use SWA (3.3–6.6 kV); advancing gate-end switchboards require Pliable Wire Armour (PWA).

Face Cutter Protection

Decoding MGM 115 Types 7 to 16

Match phase screen geometry (Cu/nylon composite vs. semi-conductive vs. 3.3 kV collective screens) directly to earth-fault relays.

Applied StandardsBS 6708 · NCB Specs (MGM 101–120) · BS 5467 · IEC 60228

Across UK National Coal Board (NCB / British Coal), Commonwealth underground collieries, potash shafts, and hard-rock extraction galleries, electrical engineers specify the MGM 101 to MGM 118 cable series. These constructions are governed by BS 6708, BS 2980, NCB Specification 188 / 295 / 492 / 504 / 505, AS/NZS 1802 / 1972, and SANS 1520 / 1507. Voltage ratings span from 110 V intrinsically safe signalling and 500 V cap-lamp cords to 0.6/1 kV and 660/1100 V low-voltage runs. Higher-power roadway and face circuits operate at 1.9/3.3 kV and 3.8/6.6 kV. This guide builds on our YnOGY, YnOGYek, YnKGY and YKGYfOyn underground gallery cable guide and Type W, Type G-GC and SHD-GC portable power cable guide. Below we compare all twenty specialized product families in our mining and tunnelling cable portfolio.

Related Engineering & Product Scope

For personnel lighting and roadway telephony, engineers specify MGM 101 500 V headcap lamp cables and MGM 110 110 V armoured telephone and signal cables. Roadway transformer feeders deploy MGM 109 Type 1012/1013/1014 0.6/1 kV single wire armoured cables and MGM 109 Type 3013 3.3 kV single armoured cables. Severe rock-fall galleries upgrade to MGM 109 Type 3023 3.3 kV unscreened double armoured cables and MGM 109 Type 3123 3.3 kV screened double armoured cables. Mobile transwitch links use MGM 111 Type 320/321 3.3 kV screened pliable wire armoured cables.

For semi-mobile gate-end box (GEB) interconnections (MGM 112), engineers deploy MGM 112 Type 201/211 660/1100 V screened armoured cables. Medium-voltage face conveyors use MGM 112 Type 331 3.3 kV screened armoured cables and MGM 112 Type 321 3.3 kV unscreened armoured cables. Auxiliary control circuits use MGM 112 Type 62/63/64 660/1100 V screened 4 mm² cables and MGM 112 Type E2/E4/E5 660/1100 V unscreened cables.

For dynamic coal-face shearers (MGM 115, BS 6708), engineers select MGM 115 Type 7 660/1100 V bare-earth cables and MGM 115 Type 7M 660/1100 V fully screened cables. Multi-motor shearers use MGM 115 Type 7S 660/1100 V 3-pilot cables. Loader and drill loops deploy MGM 115 Type 11 screened cables, MGM 115 Type 14 drill cables, and MGM 115 Type 16 two-earth cables. High-voltage 3.8/6.6 kV substations rely on MGM 118 Type 6020 double armoured cables and MGM 118 Type 6110 screened armoured cables.


1. Master Engineering Matrix Across All 20 MGM 101 to MGM 118 Colliery Cable Families

Table 1 summarizes the governing standards, voltage ratings, conductor/insulation architectures, screening/armour systems, and target underground applications across all twenty MGM product families.

Table 1. Master Engineering Matrix Across MGM 101 to MGM 120 Mining and Colliery Cable Families
Family & Model Code Governing Standards Voltage Rating Conductor & Insulation Screen, Armour & Outer Covering Primary Colliery Application
MGM 101 500V Cap-Lamp Cord (2×1 mm²) BS 6708 / NCB Spec 500 V Class 5 Tinned Cu (2×1.0 mm²) + EPR Unscreened + Polychloroprene (PCP / Neoprene) Heavy-Duty Outer Covering Miner helmet cap lamps, belt battery packs, portable gas detectors
MGM 110 110V Armoured Telephone & Signal NCB Spec 492 / BS 6708 110 V Tinned Cu Pairs/Cores (0.75–1.5 mm²) + PE/PVC Galvanized Steel Wire Armour (SWA) + Flame-Retardant PVC Roadway emergency pull-key lockout, intrinsically safe (IS) intercoms & shaft bells
MGM 109 Type 1012 / 1013 / 1014 (0.6/1 kV SWA) NCB Spec 295 / BS 6708 600/1000 V 2C (1012), 3C (1013), or 4C (1014) Cu + PVC/EPR Unscreened + Single Galvanized Steel Wire Armour (SWA, ≥50% conductance) + FR-PVC Fixed underground roadway lighting, pump stations, auxiliary switchgear
MGM 109 Type 3013 (3.3 kV Single Armoured) NCB Spec 295 / BS 6708 1.9/3.3 kV 3-Core Stranded Cu (16–300 mm²) + EPR/XLPE Unscreened + Single Layer Galvanized Steel Wire Armour (SWA, ≥50% earth conductance) + FR-PVC Main intake roadway 3.3 kV feeders to district sub-stations
MGM 109 Type 3023 (3.3 kV Double Armoured) NCB Spec 295 / BS 6708 1.9/3.3 kV 3-Core Stranded Cu (16–300 mm²) + EPR/XLPE Unscreened + Double Galvanized Steel Wire Armour (DWA) + Heavy FR-PVC Vertical mine shafts, steep drift inclines, rock-burst-prone return roadways
MGM 109 Type 3123 (3.3 kV Screened Double Armoured) NCB Spec 295 / BS 6708 1.9/3.3 kV 3-Core Stranded Cu + EPR + Individual Metallic Screen Individual Cu Tape/Wire Phase Screens + Double Galvanized Steel Wire Armour (DWA) + FR-PVC High-fault-level 3.3 kV gassy coal seams requiring sensitive earth-leakage tripping
MGM 111 Type 320 / Type 321 (3.3 kV Screened PWA) BS 6708 / NCB 504 1.9/3.3 kV Flexible Tinned Cu (3C Type 320 or 3C+1Pilot Type 321) + EPR Individual Cu/Nylon Phase Screens + Pliable Wire Armour (PWA) + Heavy PCP Semi-flexible jumpers between 3.3 kV roadway cables and mobile transwitch units
MGM 112 Type 201 / Type 211 (660/1100 V Screened PWA) BS 6708 / BS 2980 660/1100 V 4-Core (3P+1E Type 201 or 3P+1E+1Pilot Type 211) Tinned Cu + EPR Individual Cu/Nylon Phase Screens + Pliable Wire Armour (PWA) + PCP Gate-end box (GEB) inter-coupling, stage loader & armoured face conveyor (AFC) drives
MGM 112 Type 331 (3.3 kV Screened Armoured) BS 6708 1.9/3.3 kV 4-Core (3P+1E or 3P+1Pilot) Flexible Tinned Cu + EPR Individual Phase Screens + Pliable Galvanized Steel Wire Braid/Armour (PWA) + PCP 3.3 kV coal-face AFC motors, lump breakers, and high-power pump packs
MGM 112 Type 321 (3.3 kV Unscreened Armoured) BS 6708 1.9/3.3 kV 4-Core (3P+1E) Flexible Tinned Cu + EPR Collective Pliable Wire Armour (PWA, ≥50% conductance) + Heavy PCP 3.3 kV semi-portable roadway equipment and feeder extensions
MGM 112 Type 62 / 63 / 64 (660/1100 V 4 mm² Screened) BS 6708 / NCB 188 660/1100 V 2C (Type 62), 3C (Type 63), or 4C (Type 64) 4 mm² Tinned Cu + EPR Individual Phase Screens + Pliable Wire Armour (PWA) + PCP Underground coal-face lighting, remote pilot interlocking, methane monitoring
MGM 112 Type E2 / E4 / E5 (660/1100 V Unscreened PWA) BS 6708 660/1100 V 2-Core (E2), 4-Core (E4), or 5-Core (E5) Tinned Cu + EPR Unscreened Cores + Pliable Galvanized Steel Wire Armour (PWA) + PCP Auxiliary control loops, remote start/stop pushbuttons, conveyor sequence switches
MGM 115 Type 7 (660/1100 V Bare Earth Core) BS 6708 660/1100 V 3 Phase + 1 Pilot + 1 Bare Central Earth (16–95 mm²) + EPR Tinned Cu/Nylon Composite Screen on Each Power Core + Extra-Heavy PCP Coal shearers, continuous miners, roadheaders, and mobile loader supply
MGM 115 Type 7M (660/1100 V Fully Screened) BS 6708 660/1100 V 3 Phase + 1 Pilot + 1 Bare Earth + EPR + Conductive Cradle Individual Cu/Nylon Phase Screens + Overall Pliable/Conductive Screen + PCP High-risk gassy faces requiring instantaneous crush/penetration earth-fault trip
MGM 115 Type 7S (660/1100 V 3-Core Pilot) BS 6708 660/1100 V 3 Phase + 3 Pilot Cores + Bare Earth + EPR Individual Cu/Nylon Phase Screens + Heavy PCP Multi-motor coal-face machines requiring independent pilot/temperature monitoring
MGM 115 Type 11 (660/1100 V 3×16+16 mm²) BS 6708 660/1100 V 3 Phase + 1 Earth + 1 Central Pilot (16–35 mm²) + EPR Individual Tinned Cu/Nylon Phase Screens + Heavy PCP Medium-duty cutter-loaders, gathering-arm loaders, roof bolting rigs
MGM 115 Type 14 (660/1100 V Drilling Machine) BS 6708 660/1100 V 3 Phase + 1 Earth + 1 Pilot (4–6 mm², 45 mm Short Lay) + EPR Individual Cu/Nylon Phase Screens + Flexible Abrasion-Resistant PCP Hand-held and rig-mounted rotary coal and stone drilling machines
MGM 115 Type 16 (660/1100 V Two Earth Cores) BS 6708 660/1100 V 3 Phase + 2 Interstitial Earths + 1 Central Pilot (16–70 mm²) + EPR Individual Cu/Nylon Phase Screens + Heavy PCP Symmetrical earth-impedance face machinery and mobile haulage units
MGM 118 Type 6020 (3.8/6.6 kV Double Armoured) BS 6708 / NCB 505 3.8/6.6 kV 3-Core Stranded Cu (25–300 mm²) + EPR/XLPE Collective Screen + Double Galvanized Steel Wire Armour (DWA) + Heavy FR-PVC Primary 6.6 kV shaft down-droppers and main trunk roadway feeders
MGM 118 Type 6110 (3.8/6.6 kV Screened Armoured) BS 6708 / NCB 505 3.8/6.6 kV 3-Core Stranded Cu (25–300 mm²) + EPR/XLPE Individual Cu Tape/Wire Phase Screens + Galvanized Steel Wire Armour + FR-PVC 6.6 kV radially screened underground trunk feeders to face transformers

Sources: BS 6708, NCB Specification 188 / 295 / 504 / 505, BS 5467, and IEC 60228.


2. Fixed Roadway & Vertical Shaft Distribution: MGM 109 (Types 1012–3123) and MGM 118 (Types 6020 & 6110)

Use galvanized steel wire armoured MGM 109 (up to 3.3 kV) and MGM 118 (6.6 kV) for permanent colliery roadways, vertical shafts, and flameproof switchgear feeders.

2.1 Single vs. Double Galvanized Steel Wire Armour (SWA vs. DWA) and ≥50% Armour Conductance

In underground coal and potash mines governed by UK Mines and Quarries regulations (NCB Spec 295 / 505 and BS 6708), the metallic wire armour is not merely a mechanical shield. It serves as the primary earth-fault return path and must exhibit a DC conductance equal to at least 50% of the largest phase conductor within the cable. On large cross-sections (150–300 mm²), standard galvanized steel wires (GSW) alone cannot reach the 50% conductance threshold. Manufacturers therefore substitute a calculated number of tinned hard-drawn copper wires directly into the armour layer.

In horizontal roadways with stable roof support, engineers specify single-wire-armoured MGM 109 Type 1012/1013/1014 (0.6/1 kV) and MGM 109 Type 3013 (1.9/3.3 kV). In vertical mine shafts, steep drift haulages (>15°), and roadways subject to roof convergence or rock falls, double-wire-armoured (DWA) constructions are mandatory. Two counter-helical steel wire layers eliminate torsional twist under vertical suspension. Specify MGM 109 Type 3023 (3.3 kV unscreened DWA) or MGM 118 Type 6020 (3.8/6.6 kV DWA).

2.2 Individually Screened Phase Cores (Type 3123 & Type 6110) for Restricted Earth-Fault Systems

Phase-to-phase short circuits can ignite methane (CH4 Firedamp) in gassy collieries. Every radial fault must therefore become an earth fault first so restricted earth-leakage (REL) protection trips within < 80–100 ms. Both MGM 109 Type 3123 (3.3 kV screened DWA) and MGM 118 Type 6110 (3.8/6.6 kV screened) wrap each phase core in a semi-conductive screen. An individual copper tape or composite metallic screen contacts the earth system directly.

MGM 109 Type 3123 MGM 111 Type 320 MGM 112 Type 201 and MGM 118 Type 6020 cable structures
Four-panel product comparison showing (top-left) MGM 109 Type 3123 3.3kV screened double armoured cable, (top-right) MGM 111 Type 320/321 3.3kV pliable wire armoured cable, (bottom-left) MGM 112 Type 201/211 660/1100V gate-end cable, and (bottom-right) MGM 118 Type 6020/6110 6.6kV trunk feeder.

3. Pliable Wire Armoured (PWA) Gate-End & Conveyor Cables: MGM 111 & MGM 112 Series

Select pliable wire armoured (PWA) MGM 111 and MGM 112 where gate-end boxes, stage loaders, and armored face conveyors advance periodically without continuous drum reeling.

3.1 Why Pliable Wire Armour (PWA) Replaces Rigid SWA Near the Extraction Face

In advancing extraction panels, the district transformer, gate-end boxes (GEB), stage loader, and armoured face conveyor (AFC) drives sit on rail bogies (pantechnicons). These skids move forward every few days. Rigid single-wire armour (SWA) cracks or birdcages when coiled repeatedly around a 10 × OD storage loop.

The MGM 111 and MGM 112 families replace rigid single wires with Pliable Wire Armour (PWA). Multi-wire galvanized steel rope strands (7-wire or 19-wire) are laid helically over a polychloroprene inner bedding. They pair with Class 5 flexible tinned copper conductors and oil-resistant polychloroprene (PCP) outer coverings (BS 6708 / BS 2980).
– 3.3 kV Semi-Flexible Interconnections: Use MGM 111 Type 320 / Type 321 (3.3 kV screened PWA) for mobile transwitch jumpers. Specify MGM 112 Type 331 (3.3 kV screened PWA) and MGM 112 Type 321 (3.3 kV unscreened PWA) for 3.3 kV AFC motors and crushers.
– 660/1100 V Gate-End Power & Pilot Control: Specify MGM 112 Type 201 / Type 211 (660/1100 V screened PWA) for main power. Use MGM 112 Type 62 / 63 / 64 (4 mm² screened PWA) for face lighting and MGM 112 Type E2 / E4 / E5 (unscreened PWA) for sequence switches.


4. Dynamic Face-Cutter, Drill & Personnel Cables: MGM 115 (Types 7, 7M, 7S, 11, 14, 16), MGM 101 & MGM 110

Specify cradle-centered, elastomeric-screened MGM 115 trailing cables (Types 7–16) for shearers and roadheaders, paired with MGM 101 cap-lamp and MGM 110 drill cords.

4.1 Copper/Nylon Composite Phase Screens & Conductive Rubber Cradle Architecture (BS 6708)

Coal-face shearers, continuous miners, and rotary rock drills drag unarmoured elastomeric cables directly across abrasive rock floors and steel cable-handler chains (Bretby chains). To prevent open sparking under rock crush, MGM 115 cables (BS 6708) enclose each EPR power core inside a flexible composite screen. Tinned copper strands and nylon yarns are woven at opposing angles. If a sharp object penetrates the polychloroprene (PCP) outer covering, it contacts the grounded copper-nylon phase screen before reaching the live conductor, tripping the gate-end earth-leakage relay instantaneously.

4.2 Selecting Between MGM 115 Type 7, Type 7M, Type 7S, Type 11, Type 14, and Type 16

Table 2 details the exact structural differences across all six MGM 115 660/1100 V designs.

Table 2. BS 6708 / MGM 115 Trailing Cable Type Configurations (Types 7, 7M, 7S, 11, 14, and 16)
BS 6708 / MGM 115 Type Power & Pilot Core Layout Earth Conductor Configuration Phase & Overall Screening Lay Pitch & Target Face Machine
MGM 115 Type 7 3 Power + 1 Pilot (16–95 mm²) 1 Uninsulated (Bare) Tinned Cu Central Earth in Conductive Rubber Cradle Individual Cu/Nylon Composite Screen on 3 Power Cores Standard Lay — Double-ended ranging drum shearers & roadheaders
MGM 115 Type 7M 3 Power + 1 Pilot (16–95 mm²) 1 Bare Central Earth in Conductive Cradle + Overall Screen Individual Cu/Nylon Phase Screens + Overall Pliable/Conductive Screen Standard Lay — Heavy-duty coal-face shearers in high-methane seams
MGM 115 Type 7S 3 Power + 3 Pilot Cores (16–95 mm²) 1 Bare Central Earth in Conductive Rubber Cradle Individual Cu/Nylon Composite Screen on 3 Power Cores Standard Lay — Multi-motor shearers with dual pilot/thermistor interlocks
MGM 115 Type 11 3 Power + 1 Central Pilot (16–35 mm²) 1 Insulated/Screened Earth Core Laid Up with Power Cores Individual Cu/Nylon Composite Screen on Power & Earth Cores Medium Lay — Gathering-arm loaders, shuttle cars, roof bolters
MGM 115 Type 14 3 Power + 1 Pilot (4–6 mm²) 1 Earth Core Laid Around Central Conductive Rubber Cradle Individual Cu/Nylon Phase Screens Ultra-Short Lay (45 mm) — Hand-held & boom-mounted rotary drills
MGM 115 Type 16 3 Power + 1 Central Pilot (16–70 mm²) 2 Split Interstitial Earth Cores in Outer Valleys Individual Cu/Nylon Composite Screen on 3 Power Cores Standard Lay — Balanced earth-impedance haulage & cutter-loaders

Sources: BS 6708:1998 flexible trailing cables for use at mines and quarries.

4.3 Personnel Cap-Lamp (MGM 101) and Roadway Emergency Signalling (MGM 110)

Every underground worker carries a belt-pack battery connected to a helmet lamp via MGM 101 500 V headcap lamp cable (2×1 mm²). It uses extra-fine tinned copper strands, a central strain-relief cord, and sweat-resistant polychloroprene that withstands > 100,000 flex cycles. Along conveyor roadways, MGM 110 110 V armoured telephone and signal cables link pull-wire emergency stop keys, acoustic pre-start warning hooters, and intrinsically safe (Ex ia) mine telephones.

MGM 115 Type 7 Type 7M Type 11 Type 14 MGM 101 and MGM 110 cable applications
Four-panel overview of dynamic face and roadway cables: (top-left) MGM 115 Type 7/7M/7S shearer cable, (top-right) MGM 115 Type 11/16 loader cable, (bottom-left) MGM 115 Type 14 short-lay drill cable, and (bottom-right) MGM 101 cap-lamp & MGM 110 telephone cables.

5. Electrical Parameters, Earth-Fault Conductance & Restrained Plug Selection

Verify phase DC resistance, minimum metallic or elastomeric earth-fault conductance, and restrained BS 5620 plug gland entry diameter before procurement.

5.1 Conductor Cross-Sections, Outer Dimensions & Armour Resistance (MGM 109 / 112 / 115 / 118)

When matching colliery cables to BS 5620 bolted couplers or BS 3905 restrained plugs (100–400 A), verify the nominal outer dimension and maximum DC resistance (IEC 60228).

Table 3. Dimensional, DC Conductor Resistance, Earth Conductance, and Flameproof Coupler Compatibility
Model & Voltage Class Core Configuration Nominal OD Range (mm) Max Phase DC Resistance at 20 °C (Ω/km) Min Armour / Screen Earth Conductance Compatible Flameproof Coupler / Gland
MGM 101 (500 V Cap Lamp) 2 × 1.0 mm² Class 5 Tinned Cu 7.8 – 8.6 mm 19.5 Ω/km N/A (Double Insulated Battery Loop) Cap-Lamp Cord Grip & Helmet Gland
MGM 110 (110 V Signal SWA) 2C to 20Pr × 0.75 / 1.5 mm² 12.5 – 28.0 mm 26.0 / 13.6 Ω/km ≥ 50% of Phase Core via SWA Flameproof Ex d SWA Signal Gland
MGM 109 Type 1013 (0.6/1 kV) 3 × 35 mm² to 3 × 185 mm² 26.5 – 52.0 mm 0.524 – 0.0991 Ω/km ≥ 50% via SWA (+ Cu Wires if req.) BS 542 / Ex d Roadway Cable Box
MGM 109 Type 3123 (3.3 kV) 3 × 50 mm² to 3 × 240 mm² 38.0 – 66.5 mm 0.387 – 0.0754 Ω/km ≥ 50% via Phase Screens + DWA 3.3 kV 300 A / 400 A Bolted FLP Coupler
MGM 112 Type 201 (660/1100 V) 4 × 16 mm² to 4 × 120 mm² 28.5 – 56.0 mm 1.24 – 0.164 Ω/km ≥ 50% via Dedicated Earth + PWA BS 5620 200 A / 300 A GEB Flit-Plug
MGM 115 Type 7 / 7M (1.1 kV) 3 × 35 + 1P + 1E to 3 × 95 mm² 39.5 – 58.0 mm 0.565 – 0.210 Ω/km Central Bare Earth (≥50%) + Cu/Nylon BS 3905 200 A / 300 A Restrained Plug
MGM 115 Type 14 (1.1 kV Drill) 3 × 4.0 + 1E + 1P (45 mm Lay) 21.5 – 24.0 mm 5.09 Ω/km Dedicated Earth Core + Phase Screens 30 A Flameproof Drill Restrained Plug
MGM 118 Type 6110 (3.8/6.6 kV) 3 × 35 mm² to 3 × 240 mm² 46.0 – 76.0 mm 0.524 – 0.0754 Ω/km ≥ 50% via Phase Screens + SWA/DWA 6.6 kV 400 A Flameproof Bolted Coupler

Sources: BS 6708, IEC 60228 Class 5 tinned copper resistance limits, and BS 5620 / BS 3905 coupler practice.

MGM 109 MGM 112 MGM 115 and MGM 118 colliery cable cross-sections
Cross-section and construction detail grid comparing double steel wire armour (DWA), pliable wire armour (PWA), composite copper/nylon phase screens, and conductive rubber cradles across MGM 109, MGM 112, MGM 115, and MGM 118.

6. Frequently Asked Questions (FAQ)

What is the difference between MGM 115 Type 7, Type 7M, Type 7S, Type 11, and Type 16 under BS 6708?

All five are 660/1100 V EPR-insulated, PCP-covered face cables under BS 6708 with composite copper/nylon phase screens, differing in earth and pilot layout. MGM 115 Type 7 places an uninsulated tinned copper earth conductor at the center of a semi-conductive rubber cradle with 3 power cores and 1 pilot core laid around it. MGM 115 Type 7M adds an overall metallic/conductive screen around the core assembly. MGM 115 Type 7S replaces the single pilot with 3 pilot cores for multi-motor shearers. MGM 115 Type 11 uses a central pilot with 3 power cores and 1 earth core. MGM 115 Type 16 pairs a central pilot with 2 split interstitial earth cores.

Why does MGM 115 Type 14 specify a 45 mm short core lay pitch?

Hand-held and rig-mounted rotary coal/stone drills subject the last 3–5 meters of cable to tight kinking and axial twisting right behind the drill entry gland. MGM 115 Type 14 uses an ultra-short 45 mm core lay pitch around a conductive rubber cradle. Tensile and torsional loads distribute evenly without corkscrewing or snapping the 4–6 mm² conductors.

When should engineers specify MGM 109 Type 3123 or MGM 118 Type 6110 over unscreened Type 3013 / Type 6020?

Unscreened MGM 109 Type 3013, MGM 109 Type 3023, and MGM 118 Type 6020 use outer armour for earth-fault return. In gassy coal seams, phase-screened MGM 109 Type 3123 and MGM 118 Type 6110 force any internal fault to earth first. This prevents phase-to-phase arcing and trips sensitive earth-fault relays immediately.

How does Pliable Wire Armour (PWA) in MGM 111 and MGM 112 differ from standard SWA?

Standard SWA uses solid single galvanized steel wires (1.6–3.15 mm diameter) intended for fixed cleats. Pliable Wire Armour (PWA) in MGM 111 Type 320/321 and MGM 112 Type 201/211/331 uses stranded steel wire ropes (7 × 0.4–0.7 mm). This allows semi-mobile gate-end box jumpers and armoured face conveyor feeders to be coiled, dragged on pantechnicon skids, and re-routed as the coal face advances without armour kinking.


7. Request Engineering Support & Factory Quotations

Our team supplies BS 6708 / NCB roadway feeders (MGM 109 & MGM 118), pliable wire armoured gate-end cables (MGM 111 & MGM 112), and composite-screened face cables (MGM 115 Types 7–16). We also manufacture MGM 101 cap-lamp cords and MGM 110 signalling cables with full BS 6708, IEC 60332-1-2, and 50% armour conductance test reports. Before ordering roadway or gate-end lengths, check three-phase feeder drop in our Voltage Drop Calculator, verify conductor resistance in the Wire Resistance Calculator, and check shaft-cage drum clearances with the Cable Drum Length Calculator. Explore our dedicated MGM armored and screened mining cable hub and complete mining and tunnelling cable portfolio, or contact our technical desk for project selection and factory pricing.

Engineering RFQ & Datasheet Review

Confirm BS 6708 / NCB Type Number, Voltage Class, and Coupler Gland Window

Specify your MGM model (MGM 101–120), BS 6708 Type number, voltage class (500 V to 6.6 kV), phase and pilot cross-sections, metallic vs elastomeric earth screen, and restrained coupler gland window.

Request Engineering Quotation

Direct Taicang Factory Engineering

Need a Verified Construction or Datasheet?

Specifying a cable covered in MGM-101 to MGM-120 Series (MGM-101, MGM-109, MGM-112, MGM-115 & MGM-118) Complete Engineering Selection Guide? Leave your email and core/size requirement—even without final meterage—and our Taicang team replies with construction guidance, certificate scope and factory quotation.

  • ISO 9001 Cable Production
  • MOQ 50 m (Standard & Custom)
  • 7–45 Working Days
WhatsApp / Direct Line+86 156 3992 7303

    Leave Us a Message

    Whether you need a quotation, have a technical question or want a cable recommendation, our engineers reply within 24 hours.

    More Guides from the TEBAOFLEX Engineering Team

    Standard-referenced selection, sizing and construction guides from the TEBAOFLEX Cable Group engineering library.

    IEC 60228 Conductor Classes: Class 1, 2, 5 vs. Class 6 Stranding Guide

    IEC 60228 Conductor Classes: Class 1, 2, 5 vs. Class 6 Stranding, Resistance and Termination Guide

    Compare IEC 60228 Class 1, 2, 5 and 6 conductors across wire diameters (0.16–0.51 mm), 20 °C DC resistance tables, aluminum rules and lug hardware.

    Read guide
    3-Phase AC and DC Voltage Drop Calculation Formula Guide

    3-Phase AC and DC Voltage Drop Calculation Formula: 20 °C to 90 °C Scaling & Reactance

    Step-by-step calculation guide covering balanced 3-phase AC, single-phase AC and DC feeder formulas, temperature scaling and reactive impedance.

    Read guide
    DIN 47100 Color Code Chart and LiYY/YY Selection Guide

    DIN 47100 Color Code Chart: Core Sequences, VDE 0293-308 & LiYY/YY Selection

    Engineering reference for DIN 47100 1–44 core identification, IEC 60757 color abbreviations, twisted pairs and LiYY, LiYCY, YY and CY selection.

    Read guide
    1500 V DC BESS Battery Energy Storage Cable Selection Guide

    1500 V DC BESS Battery Energy Storage Cable Guide: Stranding, LSZH & Busbar Sizing

    Separate containerized BESS rack jumpers from solar PV strings across Class 5/6 stranding, LSZH halide safety and 16–400 mm² sizing.

    Read guide
    BS 7629-1 Fire-Resistant Voice Evacuation Cable Guide

    BS 7629-1 Fire-Resistant Voice Evacuation Cable Guide: PH30/PH60 vs. PH120 & 100 V Sizing

    Compare 300/500 V BS 7629-1 Standard PH30/PH60 and Enhanced PH120 fire-survival tiers, foil+CPC screens and 100 V loop voltage drop.

    Read guide
    BS 6883, BS 7917, IEC 60092 and JIS C 3410 Marine Cable Selection Guide

    BS 6883, BS 7917, IEC 60092 & JIS C 3410 Topside and Shipboard Cable Guide

    Compare UKCS offshore topside cables (BS 6883 and mica fire-survival BS 7917), commercial vessel cables (IEC 60092 / JIS C 3410) and Type P.

    Read guide
    Shielded Cable vs Armored Cable: Tinned Copper Braid vs SWA/GSWB Armor

    Shielded Cable vs Armored Cable: EMI Copper Braid vs SWA/GSWB Steel Armor

    Separate electromagnetic interference screening (LiYCY, PUR-C-HF-J) from mechanical crush and rodent protection (YSLYSY, SWA, (N)3GHSSHCH).

    Read guide
    YY vs YSLYSY Steel-Braided Control Cable Comparison

    YY vs YSLYSY Control Cable: Unarmored PVC vs Steel-Wire Braided Mechanical Protection

    Evaluate route abrasion, crush risk and steel-braid grounding requirements before substituting unarmored YY with galvanized-steel-braided YSLYSY.

    Read guide
    Types of Industrial Electrical Cables: Power, Control, Data and EV Cables

    Types of Electrical Cables Explained: Power, Control, Data & Special Duty

    Architecture overview across low/medium-voltage power feeders, screened control cables, fieldbus pairs, EV charging leads and dynamic builds.

    Read guide

    Need Expert Cable Advice?

    Contact our engineering team for technical consultation and a customised quotation.

    Get A Quote